Search Submissions ๐Ÿ”Ž

Results for "177 psma": 17 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

Biokinetic Modeling and Dosimetry of Radiopharmaceutical Extravasation in Lu-177-PSMA Therapy for Metastatic Castration-Resistant Prostate Cancer

Authors: Shaheen Dewji, Emmanuel Mate-Kole, Sergio F Ruiz, Chris C. Wang

Affiliation: Georgia Institute of Technology, Nuclear and Radiological Engineering and Medical Physics Programs, Georgiaย Institute of Technology

Abstract Preview: Purpose: Extravasations are clinical events when a substance is administered intravenously and the fluid starts to leak into surrounding tissue instead of the target vessel. In the case of radiopharma...

Clinical Factors Associated with Urinary Morbidity in Men Undergoing Combination Prostate Radiation Therapy

Authors: James Benton, Andrew Dewar, Benjamin C Lee, Ryan Y Lee

Affiliation: Radiotherapy Clinics of Georgia, Urology of Greater Atlanta

Abstract Preview: Purpose:
The purpose of our investigation was to determine if pre-treatment factors could predict urinary morbidity after combination radiation treatment for localized prostate cancer.
Methods:<...

Evaluating 177Lu-PSMA-I&t Reconstruction Parameter Influences on Image Quality and Quantification

Authors: Martin Auerbach, Jeremie Calais, Johannes Czernin, Magnus Dahlbom, Zachary Ells, Adrien Holzgreve, Koichiro Kimura, Karam Masri, Catherine (Caffi) Meyer, David Sennung

Affiliation: Department of Nuclear Medicine, UCLA, UCLA, University of California, Los Angeles

Abstract Preview: Purpose: Lutetium-177 PSMA SPECT/CT imaging offers the possibility of qualitative image analysis for tumor response assessment and quantitative image analysis for individualized dosimetry. However, th...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Integrated Catheter Position and Dwell Time Optimization for Focal Dose Escalation in Prostate HDR Brachytherapy

Authors: Bryan Bednarz, John M. Floberg, Joseph B. Schulz, Jordan M. Slagowski

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Catheter placement for high-dose-rate brachytherapy (HDR BT) is clinician dependent and potentially suboptimal for delivering simultaneous integrated boosts to intraprostatic gross tumor volu...

Interpretable Deep Learning Predicts Metastasis-Free Survival (MFS) from Conventional Imaging for Oligometastatic Castration-Sensitive Prostate Cancer (omCSPC) Using Multi-Modality PSMA PET and CT Imaging.

Authors: Yufeng Cao, Luigi Marchionni, William Silva Mendes, Cem Onal, Lei Ren, Amit Sawant, Nicole L Simone, Philip Sutera, Phuoc Tran

Affiliation: University of Maryland School of Medicine, 9Department of Radiation Oncology, Thomas Jefferson University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, University of Maryland, Baltimore, Baskent University Faculty of Medicine, Department of Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, 8Department of Pathology and Laboratory Medicine, Weill Cornell Medicine

Abstract Preview: Purpose: This study aims to predict 2-yr Metastasis-free survival (MFS) for oligometastatic castration-sensitive prostate cancer (omCSPC) patients treated by metastasis-directed therapy (MDT) by devel...

Investigating the Multimodal Fusion Techniques to Improve Prediction Accuracy of Biochemical Recurrence of Prostate Cancer

Authors: Clint Bahler, Ruchika Reddy Chimmula, Harrison Louis Love, Oluwaseyi Oderinde, Courtney Yong

Affiliation: Purdue University, Department of Urology, Indiana University School of Medicine, Advanced Molecular Imaging in Radiotherapy (AdMIRe) Research Laboratory, School of Health Sciences, Purdue University

Abstract Preview: Purpose: Prostate cancer (PCa) is a common malignancy in men, and predicting biochemical recurrence (BCR) is crucial for guiding treatment decisions. Integrating multimodal data, including clinical, i...

Learning from Failures โ€“ Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Log File-Based Patient-Specific QA As a Viable Alternative to Measurement-Based QA in IMPT

Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider

Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...

Maximum Conformity IMPT Planning with the Dynamic Collimation System

Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care

Abstract Preview: Purpose:
To perform end-to-end treatment planning and delivery verification of energy-specific collimated treatments optimized to achieve the maximum obtainable high-dose conformity using the dynam...

Monte Carlo Modeling of an Experimental X-Ray Fluorescence Computed Tomography (XFCT) System with a Pixelated CdTe Detector

Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To develop/validate a Monte Carlo (MC) model of an experimental benchtop x-ray fluorescence computed tomography (XFCT) system with a pixelated CdTe detector that can be used for MC simulation...

Ratoguide: Evaluation of AI-Driven Fully Automated Treatment Planning Support System for Lung SBRT

Authors: Keiichi Jingu, Noriyuki Kadoya, Takafumi Komiyama, Takeru Nakajima, Hikaru Nemoto, Hiroshi Onishi, Masahide Saito, Ryota Tozuka

Affiliation: Department of Radiology, University of Yamanashi, Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Department of Advanced Biomedical Imaging, University of Yamanashi

Abstract Preview: Purpose: We evaluated the accuracy of a new AI-based fully automated planning software in stereotactic body radiotherapy (SBRT) for early-stage lung cancer.
Methods: We collected data from 125 pati...

Using Multi-Peak Reconstructions for Dosimetry of Fast and Quantitative Lutetium-177 SPECT/CT

Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija

Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging

Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...