Search Submissions 🔎

Results for "240 mev": 159 found

3D Bioprinted Brain Cancer Constructs for Experimental Synchrotron Radiotherapy

Authors: John Paul Ortiz Bustillo, Elette Engels, Elrick T. Inocencio, Michael Lerch, Julia Rebecca D Posadas, Anatoly Rosenfeld, Kiarn Roughley, Moeava Tehei, Gordon Wallace, Danielle Warren, Vincent de Rover

Affiliation: Centre for Medical Radiation Physics, University of Wollongong Australia, Department of Radiology, University of the Philippines- Philippine General Hospital, Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, University of Wollongong Australia, Centre for Medical Radiation Physics, University of Wollongong, Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, University of Wollongong, University of the Philippines Manila; Centre for Medical Radiation Physics, University of Wollongong Australia

Abstract Preview: Purpose: To compare the biological response through cell viability assay and fluorescence imaging of 3D bioprinted brain cancer (glioma) constructs relative to 2D monolayer and 3D spheroid culture for...

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Deep Learning Method for Direct Vmi Inference Using a Dual-Layer Radiotherapy Kv-CBCT Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: A challenge for dual energy CBCT is that noise and residual errors in material decomposition steps can become amplified when forming low energy, high contrast virtual mono-energetic images (V...

A Deep Learning-Based Method for Rapid Generation of Spot Weights in Single Field Optimization for Proton Therapy in Prostate Cancer

Authors: Yu Chang, Mei Chen

Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine

Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...

A Dosimetric Study of Small-Field Apertured Spot-Scanning Proton Stereotactic Radiosurgery for Pediatric Brain Tumors

Authors: Chin-Cheng Chen, Chia-Ho Hua, Christopher J. Kutyreff, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: A dosimetric study was conducted to determine the optimal field parameters for a commercially available small-field applicator (SFA) used in spot-scanning proton stereotactic radiosurgery, pa...

A Knowledge-Based Approach for High-Quality Accelerated Partial Breast Irradiation Using Stereotactic Body Radiotherapy

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Allison Dalton, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: External-beam Accelerated Partial Breast Irradiation (APBI) using stereotactic-body radiotherapy (SBRT) is increasingly adopted as an alternative to whole-breast radiation, offering targeted ...

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

A Predictive Tool for Optimizing Treatment System Allocation in Hypofractionated Whole-Breast Radiotherapy

Authors: Zhenzhen Dai, Anthony J. Doemer, Ryan Hall, Kenneth Levin, Bing Luo, Benjamin Movsas, Karen C. Snyder, Kundan S Thind, Eleanor Walker

Affiliation: Henry Ford Health, HFHS

Abstract Preview: Purpose: To investigate the feasibility of a predictive tool for efficient allocation of hypofractionated whole-breast irradiation patients between Varian Truebeam and Ethos systems.
Methods: A ful...

A Preliminary Study of Light-Weighted and Flexible Bismuth Nanoparticle-Based Polymer Matrix for Efficient Radiation Shielding

Authors: Ming Su, Yuenan Nancy Wang

Affiliation: Northeastern University, Hartford Healthcare

Abstract Preview: Purpose: High Z elements such as lead are often used to protect critical structures in clinical radiotherapy. Nanoparticles have different properties than bulk materials. We proposed a polymer matrix ...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

A Robust Quantitative Metric for Optimal Beam Selection in Radiotherapy of the Peripheral Lung Lesions: A Crucial Step in Standardization of Lung SBRT

Authors: Leslie Bell, Kai Ding, Reza Farjam, Russell K Hales, Sarah Han-Oh, Hamed Hooshangnejad, Jina Lee, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Optimal beam arrangement is crucial in automation and standardization of thorax radiotherapy where substantial tissue heterogeneity and several critical organs at risks (OARs) exist. Here, we...

A Single-View-Based Electroacoustic Tomography Imaging Using Deep Learning for Electroporation Monitoring

Authors: Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of California, Irvine

Abstract Preview: Purpose: To achieve the full-view image from a single-view sinogram using a two-stage deep learning model for electroacoustic-tomography (EAT), which is an emerging imaging technique with significant ...

A Surface-Conforming Flexible Collimator for Improving Electron Radiotherapy

Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz

Affiliation: UT Health San Antonio

Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...

AI-Driven Early Detection of Digital Radiography Performance Degradation: A Predictive Quality Control Approach

Authors: Giovanni Iacca, Gloria Miori, Laura Orsingher, Daniele Ravanelli, Annalisa Trianni

Affiliation: Department of Information Engineering and Computer Science, University of Trento, Medical Physics Department, S.Chiara Hospital, APSS

Abstract Preview: Purpose: This study aims to leverage artificial intelligence (AI) to predict and identify performance degradation in Digital Radiography (DR) systems, enabling proactive maintenance and minimizing cli...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

Adaptive Proton Flash Therapy through Iterative Modular Pin Recycling

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...

An Alpha Irradiation System for Radiobiological Studies with Versatile Dose Rate Control

Authors: Harsh Arya, Yan Chang, Yujie Chi, Varghese Anto Chirayath, Joshua Rajan, Pan Zui

Affiliation: University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: In targeted alpha therapy (TAT), absorbed dose rates can vary significantly spatially and temporally, impacting therapeutic efficacy as well as carcinogenic potential. This study reports the ...

An Analytical Approach to Monitor Unit Calculation in Extended Distance Total Body Irradiation (TBI)

Authors: Cheewai Cheng, Indra J. Das, Jeffrey Yui Hei Wong, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Radiation treatment machine replacement brings chaos and urgency of timely completion of machine commissioning for every procedure used including TBI that are time consuming. Based on past ex...

Assessment of Deep Learning Models for 3D Dose Prediction in Prostate Cancer SIB-IMRT Using MR-Linac

Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan

Affiliation: University of Florida

Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...

Assessment of Material Discrimination Slopes in Dual Energy CT Imaging

Authors: Izabella L. Barreto, Aroon Pressram

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...

Assessment of Plan Quality Metrics for Iroc Houston SRS Phantom Performance Evaluation

Authors: Derek Matthew Garcia, Mallory Glenn, Stephen F. Kry, Ruitao Lin, Dennis S. Mackin, Tucker J. Netherton

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas’ MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: This study aims to investigate the feasibility of implementing clinically relevant quality metrics for evaluating IROC SRS phantom plans, including conformity index (CI) and homogeneity index...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Automated IMPT Treatment Planning for CSI: Enhancing Efficiency with Auto-Segmentation and Scripting

Authors: Katja M. Langen, William Andrew LePain, Robert Muiruri, Vivi Nguyen, Mosa Pasha, Roelf L. Slopsema, Alexander Stanforth, Yinan Wang, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) treatment planning for craniospinal irradiation (CSI) is complex and requires extensive effort from the planner. This study aims to enhance planning ...

BEST IN PHYSICS RADIOPHARMACEUTICALS, THERANOSTICS AND NUCLEAR MEDICINE: Characterization and Dose Rate Calibration of a Semiconductor-Based Radiation Imaging Survey Meter

Authors: Steven Brown, Mike Hopkins, Jerimy C. Polf, Scott Sawyer, Benjamin L. Viglianti

Affiliation: H3D, inc, University of Michigan, M3D, Inc, M3D Imaging

Abstract Preview: Purpose: We characterized the sensitivity, energy dependence, and calibrated dose rate for a radiation imaging survey meter (RAVIN Cam; M3d inc., Ann Arbor MI) based on cadmium zinc telluride (CZT) cr...

BEST IN PHYSICS RADIOPHARMACEUTICALS, THERANOSTICS AND NUCLEAR MEDICINE: The Development and Validation of an in-Vitro Alpha Irradiation Platform with Versatile Radiation Control

Authors: Md Mainul Abrar, Harsh Arya, Yujie Chi, Yijing Liu, Joshua Rajan, Pan Zui

Affiliation: University of Texas at Arlington, The University of Texas at Arlington, Department of Physics, University of Texas at Arlington

Abstract Preview: Purpose: Understanding the biological effects of alpha radiation at varying dose rates and energies is essential for advancing therapeutic strategies. This study demonstrates the capabilities of an in...

Beam Characteristics of a Proposed Dielectric Wall Proton Accelerator Design

Authors: Julien Bancheri, Chau Giang Bui, Christopher M Lund, Morgan J Maher, Jamiel Nasser, Amy Parent, Monica Serban, Jan P. Seuntjens, Jason Z Yuan

Affiliation: University of Toronto, Medical Physics Unit, McGill University, Princess Margaret Cancer Centre, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: Proton therapy (PT) has demonstrated greater precision and superior healthy tissue sparing compared to photon radiotherapy for various sites; however, PT systems are expensive, which limits g...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Breathing New Life into Pulmonary Imaging: Development and Clinical Validation of an X-Ray Interferometry System

Authors: Rachael Blair, Les Butler, Lillian Dickson, Kyungmin Ham, Charles Hartman, Kenneth (Kip) Matthews, Corinne Vanya

Affiliation: Louisiana State University, University of Minnesota, Refined Imaging LLC, Center for Advanced Microstructures and Devices

Abstract Preview: Purpose:
To develop and evaluate an x-ray interferometry system (XIS) for low-dose, high-sensitivity diagnostic imaging of lung diseases such as chronic obstructive pulmonary disease (COPD), asthma...

Centralizing Resources with a Microsoft-Based Wiki Platform: Enhancing Collaboration and Efficiency in Radiation Oncology

Authors: Simon Brundage, Jiajin Fan, Ulrich Langner, Qiongge Li, Jian Liu, Wei Nie, Edwin Quashie, Xiaofeng Zhu

Affiliation: Brown University Health, Hofstra University Medical Physics Program, Inova Hospital, Inova Schar Cancer Institute, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Managing departmental policies, clinical protocols, QA procedures, workflows, and troubleshooting documentation is critical in radiation oncology. A Microsoft-based wiki platform was devel...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization of a Prototype Flashdiamond Detector for Conventional and Uhdr Beams

Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Clinical Factors Associated with Urinary Morbidity in Men Undergoing Combination Prostate Radiation Therapy

Authors: James Benton, Andrew Dewar, Benjamin C Lee, Ryan Y Lee

Affiliation: Radiotherapy Clinics of Georgia, Urology of Greater Atlanta

Abstract Preview: Purpose:
The purpose of our investigation was to determine if pre-treatment factors could predict urinary morbidity after combination radiation treatment for localized prostate cancer.
Methods:<...

Combining Proton Flash and Spatially Fractionated Radiotherapy – Experimental and Simulation Based Dosimetric Characterization

Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore

Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comparative Analysis of Soft Tissues and 3D Printing Materials Using Euclidean Distance for Linear Attenuation Coefficient

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Elsa Bifano Pimenta

Affiliation: University of SĂŁo Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study evaluates the similarity between the linear attenuation coefficients of soft tissues and 3D printing materials in diagnostic imaging range using the Euclidean distance approach.

Comparison of Ultra-High Resolution and Standard CT Imaging Modes for Small Vessel Visualization in Coronary CTA Using Photon Counting CT

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: This study evaluates the impact of ultra-high resolution (UHR) mode on the visualization of small vessels in coronary computed tomography angiography (CTA) using a photon-counting CT scanner....

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Conformal Flash for Large Treatment Fields

Authors: Julien Forthomme, Carolina Llina Fuentes, Valentin Hamaide, Lucian Hotoiu, Rudi Labarbe, Rasmus Nilsson, Arnaud Pin, Francois Vander Stappen, Erik Traneus

Affiliation: RaySearch Laboratories AB, Ion Beam Applications SA

Abstract Preview: Purpose: Conformal FLASH achieves ultra-high-dose-rate (UHDR) proton therapy (>40 Gy/sec) by scanning a mono-energetic pencil beam through accessories (range shifter, Conformal Energy Modulator, apert...

Correction Factors for Estimating Skin Dose from Overresponse of Two Commercial Optically Stimulated Luminescence Dosimeters

Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine

Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...

Creation of Pass-through Proton Minibeams Using a Single Quadrupole Magnet

Authors: Abdullah A. Alshreef, Grant A. McAuley, Jerry D Slater

Affiliation: Loma Linda University Medical Center, Loma Linda University

Abstract Preview: Purpose: In this project we investigate the use of a single permanent magnet quadrupole to create pass-through proton minibeams suitable for potential clinical use and preclinical radiobiology experim...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Deep Learning-Based Multileaf Collimator Sequence Prediction for Automated VMAT Treatment Planning in Pancreatic Cancer

Authors: Zixu Guan, Takahiro Iwai, Takashi Mizowaki, Mitsuhiro Nakamura, Michio Yoshimura

Affiliation: Kyoto University, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose:
The goal of this study is to develop a fully automated treatment planning approach for VMAT in pancreatic cancer that can convert patient anatomy into LINAC machine parameters. In this wor...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Detection of the Linac Jaw Face Angle Misalignment: Case Studies

Authors: Peter Balter, Andres V Cibrian, Song Gao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to demonstrate a means of detecting misaligned jaw face angles on the Varian TrueBeam based on a beam symmetry metric for electron beam profiles.
Methods: Duri...

Determine Noise Weighting Factor in Photon-Counting CT Via Deep Learning for Personalized Noise Reduction

Authors: Xinhui Duan, Roderick W. McColl, Mi-Ae Park, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: UT Southwestern Medical Center, Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Image-based deep-learning noise-reduction techniques have been developed for photon-counting CT (PCCT) to improve image quality with reduced radiation dose. The denoising strength is typic...

Developing Metrics for Evaluating Machine Matching across Elekta Linear Accelerators in a Multicenter Clinic

Authors: Ashley Elizabeth Bonner, Michael G. Snyder

Affiliation: Corewell Health William Beaumont University Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: Develop and evaluate metrics for assessing beam matching of profiles across Elekta linacs in a multisite clinical setting.
Methods: Four Elekta linear accelerators (three VersaHD and one A...

Development of Hi-C Based DNA Geometry and Early DNA Damage Evaluation: A Topas-Nbio Study

Authors: Alejandro Bertolet, Isaac Meyer, Harald Paganetti, Jan PO Schuemann, Wook-Geun Shin

Affiliation: Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a methodology for Monte Carlo modeling of cell-specific DNA geometries based on Hi-C data using TOPAS-nBio, and to evaluate early DNA damage distributions.
Methods: Hi-C data of...

Development of an Eclipse Scripting API-Based Toolbox for Automated Planning in Non-Small Cell Lung Cancer: Feasibility and Validation Study

Authors: Ming Chao, Hao Guo, Tenzin Kunkyab, Yang Lei, Tian Liu, Kenneth Rosenzweig, Robert Samstein, Junyi Xia, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose:
This study aims to develop and validate an Eclipse Scripting Application Programming Interface (ESAPI)-based planning toolbox that incorporates preset human expertise to improve planning e...

Differential Gastrointestinal Responses to Synchrotron-Produced Proton and Electron Irradiation Under Flash and Conventional Conditions

Authors: Luke Connell, Nolan M. Esplen, Elise Konradsson, Albert C. Koong, Ziyi Li, Steven Hsesheng Lin, Kevin Liu, Billy W Loo, Devarati Mitra, Radhe Mohan, Emil Schueler, Takeshi Takaoka, Uwe Titt, Xiaochun Wang, Ming Yang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study aimed to assess radiation-induced gastrointestinal (GI) toxicity in mice subjected to abdominal irradiation using protons at ultra-high-dose-rate (UHDR) and conventional dose-rates...

Direct Measurement of DNA Damage to Determine Dose and Biological Effectiveness

Authors: Michael Lamontagne, Ileana Pazos, Jerimy C. Polf, Joseph W. Robertson, Teniola Tobun, Ronald E. Tosh, Michael Zwolak

Affiliation: Biophysics and Biomedical Research Group, Microsystems and Nanotechnology Division, National Institute of Standards and Technology, M3D, Inc, National Institute of Standards and Technology, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To study how damage to DNA molecules increases and changes as a function of the type and dose of radiation.

Methods: DNA molecules of a known length (number of base pairs (BP)) within ...

Dose Rate Measurements of Scanning Carbon Ion Beams Using a Plastic Scintillator Detector

Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava

Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center

Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...

Dosimetric Characteristics of a Commercially Available Platinum Cured Silicone Rubber Material As a Custom Bolus Option

Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon

Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center

Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectorsℱ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko SalomĂłn Alva SĂĄnchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Dosimetry Calibration for Low-Energy Protons (2-4 MeV) Using Gafchromic Film Dosimeters

Authors: Michael Dingfelder, Homeira Faridnejad

Affiliation: East Carolina University, Department of Physics, East Carolina University

Abstract Preview: Purpose: To use Gafchromic film for measurement of the dose delivered by low-energy (2-4 MeV) protons to living cells.
Methods: Five different types of Gafchromic films were tested for dosimetry un...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Energy Dependency of Biological Effects from Radiation Scattering Around Medical Implants in Particle Therapy

Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum

Affiliation: Osaka University, Texas A&M University

Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Enhancing Robustness in Proton Therapy through Online Adaptive Workflow: An in-Silico Study

Authors: Robbie Beckert, Weiren Liu, Thomas R. Mazur, Allen Mo, Stephanie Perkins, Hailei Zhang, Tianyu Zhao

Affiliation: Washington University in St. Louis School of Medicine, University of South Florida, WashU Medicine

Abstract Preview: Purpose: Online adaptation may mitigate uncertainties in proton therapy arising from interfractional anatomical changes. While robust optimization accounts for setup and range uncertainties during pla...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Establishing Energy Thresholds for Targeted Cherenkov Light Photoactivation

Authors: David Alcorta, Lindsay Bolino, Olivia Canter, Seifallah Emam, Joseph Farina, Timothy Haystead, Philip Hughes, Keshav Jha, David Loiselle, Mark Oldham, Victoria J. P. Radosova

Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Duke Univerity, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: To simulate how Cherenkov light (CL) produced during radiation therapy can activate targeted photodynamic molecules. To experimentally determine dose and concentration thresholds for biologic...

Establishing Radiotherapy in Malawi through an International Medical Physics Collaboration

Authors: Ruth Afanador, Daniela Branco, John M Bryant, John Campbell, Clement Chaphuka, Samuel A. Einstein, David B. Flint, Jeffrey R. Kemp, Mussa Kumwembe, Daniel J Mollura, Joseph Weygand

Affiliation: RAD-AID International, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Applied Science, Dartmouth Health, UNC Health, Malawi National Cancer Center, Kamuzu Central Hospital, Penn State College of Medicine, Sutter Health, New York University, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose: Malawi, a landlocked country in southeastern Africa with a population of over 20 million, ranks among the world’s least-developed nations and has the fourth-lowest gross domestic product per ...

Evaluating DNA Damage Efficacy for 90y and 225ac Based Radiotherapy

Authors: Ramin Abolfath, Alejandro Bertolet, Kofi M. Deh, Rao Khan, Vanessa Sanders, Daniel Suarez-Garcia

Affiliation: Massachusetts General Hospital and Harvard Medical School, University of Sevilla, Brookhaven National Laboratory, Howard University

Abstract Preview: Purpose: To compare the efficacy of 225Ac to 90Y for local cancer therapy by quantifying DNA damage using Monte Carlo simulations.
Methods: The TOPAS n-Bio toolkit was used to simulate the irradiat...

Evaluating the Theranostic Potential of a Novel Shark Derived Anti-MET Vnar Antibody in NSCLC

Authors: Andrew M Baschnagel, Jonathan W. Engle, Jessica E. Griffin, Gihan Gunaratne, Reinier Hernandez, Randall J Kimple, Aaron M. LeBeau, Natalie Y. Luo, Rachel Minne, Caroline M. Mork, Kwangok P Nickel, Jayden West, Madalynn R. Wopat

Affiliation: University of Wisconsin, University of Wisconsin, Department of Pathology and Laboratory Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin–Madison, University of Wisconsin - Department of Human Oncology, UW Madison, University of Wisconsin, Department of Medical Physics

Abstract Preview: Purpose: The Mesenchymal-Epithelial Transition gene (MET), a targetable cell surface receptor responsible for stimulating cell growth and proliferation, is altered in approximately 10% of non-small ce...

Evaluation of Charge Collection Performance in the A30 Prototype Parallel Plate Ion Chamber in Ultra-High Dose Rate Beam

Authors: Mervat A. Alharbi, Wesley S. Culberson

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison

Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexionℱ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXionÂź X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of the Hyperscint RP-200 Plastic Scintillation Dosimetry System for Reference Dosimetry in Ultra-High Dose Rate Electron Beam Therapy: A Comparative Study

Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx

Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...

Evaluation of the Imaging Performance of PET-Linac As Compared to a Diagnostic PET/CT System for Small Tumors

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Extending Chronorepair: A Computational Model of the Effects of Radiotherapy in Cells

Authors: Alejandro Bertolet, Jose Antonio Lopez-Valverde, Victor V. Onecha, Daniel Puerta

Affiliation: Dana Farber Cancer Institute/Brigham and Women's Hospital, Departamento de FĂ­sica AtĂłmica, Molecular y Nuclear, Universidad de Granada, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Besides its superior dose conformity, proton therapy induces greater damage to tissue than conventional radiotherapies. This increased damage is usually quantified through the concept of rela...

Eye-Tracking Analysis of Radiologist Preferences in PET Imaging: Comparing 5-Ring and 6-Ring Detector Configurations

Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout

Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Feasibility of Zap-X Beam Quality Assurance Using Cherenkov Radiation

Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao

Affiliation: University of Miami

Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

First Beam Characterization of the Radiabeam FLEX-9 Electron Flash Linac

Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron

Affiliation: RadiaBeam Technologies, University of Iowa

Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers SÞrensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich), Ludwig-Maximilians UniversitĂ€t, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Flash Radiation Spares Reproductive Capability in Adult C. Elegans

Authors: Barry Andricks, Stratton Black, Scott R. Floyd, Ashutosh Kotwal, Eric L. Martin, Stepan Mikhailov, Mark Oldham, Niccolo Terrando, Andrew Thompson, Ying Wu

Affiliation: Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University, Department of Radiation Oncology, Duke University Medical Center, Triangle Universities Nuclear Laboratory

Abstract Preview: Purpose: To evaluate and quantify the effects of high energy electron radiation delivered at FLASH and conventional dose rates on the reproductive capability of adult C. elegans nematodes.
Methods:...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

Hyperbaric Oxygen Therapy Prior to SRS Does Not Enhance Radiosensitivity in the Murine Glioblastoma Model

Authors: Beverly Allen, Jay C. Buckey, David J. Gladstone, P. Jack Hoopes, David I Hunter, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, Geisel School of Medicine, Dartmouth College, Geisel School of Medicine, Thayer School of Engineering

Abstract Preview: Purpose: Hyperbaric oxygen (HBO) therapy immediately prior to radiation therapy has been proposed as treatment to enhance radiosensitivity of hypoxic tumors. A murine glioblastoma model was utilized t...

Imaging Performance of Direct-Indirect Dual-Layer Flat-Panel-Detector Prototypes for Contrast-Enhanced Digital Mammography

Authors: Salman M. Arnab, Yves Chevalier, Samuel Gagné, Adrian F. Howansky, Luc LaperriÚre, Xiangyi Wu, Wei Zhao

Affiliation: Stony Brook Medicine, Analogic Canada

Abstract Preview: Purpose: A direct-indirect dual-layer flat-panel-detector (DI-DLFPD) is under development for patient motion artifact-free contrast-enhanced digital mammography (CEDM). DI-DLFPD comprises a direct fro...

Imaging Preclinical Proton Flash Radiation Using a Small Animal PET System

Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...

Immune Response on Ultra-High Dose Rate (FLASH) and Conventional Proton Radiation in a Mouse Xenograft Model

Authors: Ning Cao, Sunan Cui, Danielle P. Johnson Erickson, Juergen Meyer, Ramesh Rengan, Ben A Shaver, Jing Zeng

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington and Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: To investigate the immune response in primary irradiated tumors and non-irradiated tumors in a mouse melanoma xenograft model, comparing 18Gy of conventional (CONV) and ultra-high dose rate (...

Impact of Computed Tomography Noise Reference Levels in a Pediatric Hospital

Authors: Samuel L. Brady, Joseph G. Meier

Affiliation: Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To establish noise reference levels for our pediatric hospital.
Methods:
Water equivalent diameter (Dw) and image noise was automatically measured by using a global noise algorithm i...

Impact of IMRT Beam Scatter and Electronic Noise on Real-Time Kv and Fluoroscopy Image Quality

Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky

Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...

Impact of Lung Density on Plan Quality and Delivery Parameters in Lung Stereotactic Body Radiation Therapy (SBRT) Plans

Authors: David Chighvinadze, Indra J. Das, Jeremy D. Donaghue, Kevin Stephans, Gregory Videtic, Sugandima Weragoda, Ping Xia

Affiliation: Cleveland Clinic, Cleveland Clinic Sandusky, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Cleveland Clinic Fairview

Abstract Preview: Purpose:: Evaluate the impact of lung density variations on plan quality and delivery parameters in lung SBRT Plans.
Methods: For a hypothetical case with a real patient anatomy, three GTVs with vo...

Impact of Nanoscale TEM-Based and Simplified 3D Modeling Approaches on Monte Carlo Studies of Radiosensitization Effects in Gnp-Laden Cells

Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Amrit Kaphle

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To assess the effectiveness of various nanoscale models of gold nanoparticle (GNP)-laden cells for Monte Carlo (MC) studies of GNP-mediated radiation dose enhancement/DNA damage.

Metho...

Impact of Patient Size on the Choices of Dual and Single Energy CT for Accurate Liver Fat Volume Fraction Quantification

Authors: Xinhua Li, Jie Zhang, Yifang (Jimmy) Zhou

Affiliation: University of Kentucky, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. CT can be a good modality for FVF assessment if the accuracy is adequate. We aimed to study the impa...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Impact on image quality from reduced dose conebeam CT for pediatric fluoroscopy-guided interventional (FGI) imaging

Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier

Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...

Initial Phantom Studies Towards Implementation of Sequential Dual Energy CBCT on an Adaptive Radiotherapy Linac Platform

Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam

Affiliation: University of Michigan

Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...

Innovative Design and Simulation of a Pediatric-Dedicated SPECT: Enhancing Imaging Performance for a Healthier Scans in Children

Authors: Mohammadreza Ay, Nahal Daneshgar, Nima Kasraie, Abbas Monsef, Zeinab Peymani, Hadi Rezaei, Peyman Sheikhzadeh

Affiliation: University of Minnesota Medical School, Radiation Oncology, Department of Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Shiraz University of Medical Sciences, Department of Medical Physics, Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, UT Southwestern Medical Center, Imam Khomeini Hospital Complex,Tehran University of Medical Sciences

Abstract Preview: Purpose:
This study aims to design and simulate an innovative pediatric-dedicated SPECT scanner optimized for children’s unique anatomical and safety needs by enhancing sensitivity in data acquisit...

Integrating SPECT and Compton Imaging for Multi-Energy Photon Reconstruction

Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu

Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Interplay of Relative Biological Effectiveness and Dose Rate in Eye Plaque Brachytherapy with Low Energy Photons

Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart

Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington

Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...

Investigating Racial Differences in 68ga-PSMA-11 PET/CT Imaging for Patients with Biochemical Recurrence after Radical Prostatectomy: Preliminary Findings

Authors: Maya Ataya, Clint Bahler, Ramotallah Dami Jubril, Michael Koch, Oluwaseyi Oderinde, Mark Tann

Affiliation: Purdue University, epartment of Urology, Indiana University School of Medicine, Department of Urology, Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indiana University School of Medicine

Abstract Preview: Purpose:
To investigate racial differences in the detection of biochemical recurrence (BCR) using 68Ga-PSMA-11 PET/CT, known for its improved sensitivity and specificity in patients after radical p...

Investigating X-Ray Flash Effect on Plasmid DNA with Combined Microscopic Monte Carlo and Analytical Simulations

Authors: Xun Jia, Youfang Lai

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Ultrahigh dose rate FLASH (>40 Gy/s) radiotherapy (RT) has attracted significant attention. The mechanism remains unclear, hindering clinical translation. This study investigated the behavior...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Investigation of Low Iodine Concentration Detectability of Dual-Energy CT Imaging Using a Customized 3D Printed Phantom

Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Leveraging Photon Counting Detector CT and Advance Reconstructions to Improve the Accuracy of Vessel Tracing in Prostate Artery Embolization

Authors: Christopher P. Favazza, Andrea Ferrero, Taylor Froelich, Forrest Linch, Scott Thompson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Photon counting detector (PCD) CT is a promising tool to enhance pre-procedural planning and intra-procedural guidance for prostate artery embolization due to its unsurpassed ultra-high spati...

Lu-177 Recovery Coefficients Using Tc-99m Surrogate Method: Intra- & Inter-Scanner Comparison

Authors: Ben Piacitelli, Celeste Winters

Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Modernization of the NIST Air-Kerma Strength Standard for LDR Brachytherapy Seeds

Authors: Michael G. Mitch, Csilla I. Szabo-Foster

Affiliation: National Institute of Standards and Technology

Abstract Preview: Purpose: The U.S. air-kerma strength standard for low-dose-rate (LDR) low-energy photon-emitting brachytherapy sources provides measurement traceability for calibrations at the AAPM Accredited Dosimet...

Monte Carlo Evaluation of Water-Equivalent Materials for Nanowire-Based Oslds in Flash Radiotherapy

Authors: James Chun Lam Chow, Harry E Ruda

Affiliation: University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: FLASH radiotherapy (FLASH-RT) with dose rate greater than 40 Gy/s, has demonstrated potential in reducing normal tissue toxicity while maintaining tumor control. However, accurate and reliabl...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

On the Development and Commissioning of an in-Vivo Dosimetry Program Using Small Pieces of Gafchromic Film

Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Optimizing Design to Enhance the Energy Separation in a Kv Dual-Layer Imager (DLI)

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Multi-layer flat-panel imagers can improve for clinical image-guided radiotherapy applications, including the enhanced visualization of soft tissue and a reduction in image artifacts. Each im...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Optimizing Prostate Cancer Radiotherapy: Comprehensive Analysis of Automated Planning with Neural Network-Based Dose Prediction

Authors: Seungtaek Choi, Laurence Edward Court, Eun Young Han, Yusung Kim, Hunter S. Mehrens, Tucker J. Netherton, Shiqin Su

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Automated treatment planning is gaining traction for its enhanced consistency and efficiency. A key challenge, however, lies in the inability of neural network dose predictions directly trans...

PET Guided Radiation Therapy for Large Planning Target Volume Expansions of Small PET-Active Gross Tumor Volumes

Authors: Sarah Dumont, Trevor Ketcherside, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose:
The RefleXion X1 SCINTIX algorithm convolves beam fluence with real-time PET distributions for tracking and plan adaptation, but radiotherapy Planning Target Volumes (PTVs) are often signi...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-ChacĂłn, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Plastic Scintillating Detector Assisted Spot Mapping for Patient Specific Quality Assurance in Proton Beam Therapy

Authors: Saad Bin Saeed Ahmed, Marcos Feijoo, Wazir Muhammad, Charles Shang, Naseem Ud Din

Affiliation: South Florida Proton Therapy Institute, Miami Cancer Institute, Blue Physics LLC, Florida Atlantic University

Abstract Preview: Purpose: This study introduces a novel approach for patient-specific quality assurance in proton beam therapy, utilizing new plastic scintillator detectors with high temporal resolutions to create det...

Presurgical Treatment Planning for Gammatile Implants

Authors: Timothy J Allen, Clara Ferreira

Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: Presurgical treatment planning for GammaTile cranial implants is limited to estimates of required tiles and provides no positioning information. Existing tools are intended for tile estimatio...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Proton Therapy Treatment Planning for Thoracic Cancer: A Comparative Analysis of Single and Multi-Field Plans

Authors: Gueorgui Gueorguiev, Kavya Thaniyarasu

Affiliation: University of Bologna, National Centre of Radiobiology and Radiation Protection

Abstract Preview: Purpose: This study investigates the clinical viability of double scattering proton therapy treatment planning for thoracic malignancies using single or multiple treatment fields. The aim of this stud...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Quantitative Forward Modeling of Propagation-Based X-Ray Phase-Contrast Imaging at Clinical Scale

Authors: Giavanna Luisa Jadick, Patrick J La Riviere, Cailey Riggs

Affiliation: University of Chicago

Abstract Preview: Purpose: We explore the accuracy of physics models for propagation-based x-ray phase-contrast imaging (XPCI) with an eye to future clinical implementation, providing a practical assessment of detectio...

Radiation Shielding Considerations for Ultra-High Dose Rate Electron Flash Radiation Therapy

Authors: Alexandru Badalan, Peter Petric, I. Antoniu Popescu, Andrew Kyle Henderson Robertson

Affiliation: Bc Cancer, BC Cancer - Vancouver, BC Cancer

Abstract Preview: Purpose: Ultra-high dose rate (>40 Gy/s) or “FLASH” radiation therapy (RT) has the potential to improve cancer treatment through reduced radiation side effects. While electron FLASH beams can be produ...

Raman Spectroscopy Identifies Biomolecular Differences between Caucasian and African American Prostate Cancer Patients

Authors: Nrusingh C. Biswal, Manas R. Gartia, Maria Iftesum, Sanjit K. Roy, Gyana Ranjan Sahoo, Elnaz Sheikh, Hem D. Shukla, Madhur Srivastava

Affiliation: Department of Chemistry and Chemical Biology, Cornell University, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Mechanical and Industrial Engineering, Louisiana State University

Abstract Preview: Purpose: Prostate cancer incidence and mortality levels in African-American men are the highest among all ethnic groups. This points to the role of biological factors in driving disparate outcomes. He...

Remote Evaluation of Flash Beamlines for Electron, Proton, and MV Photons

Authors: Alexander Baikalov, Luke Connell, Nolan M. Esplen, Michele M. Kim, Stephen F. Kry, Emil Schueler, Hayden Scott, Ryan Sun, Paige A. Taylor, Uwe Titt

Affiliation: The University of Texas MD Anderson Cancer Center, University of Pennsylvania, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: to develop an affordable, portable device for accurately measuring FLASH dose rates from protons, electrons, and photons. 4 detectors were utilized to measure the temporal structure of proton...

Safety of Off-Axis Treatment for Selection of Optimal Beam Angles in SBRT of the Posteriorly Located Lung Lesions

Authors: Reza Farjam, Russell K Hales, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Optimal beam angles and off-axis isocenter selection are important to achieve high quality plan and collision-free delivery in stereotactic body radiotherapy (SBRT) of the posteriorly located...

Spatial Variation and Dosimetry of X-Ray Contamination in Total Skin Electron Beam Therapy

Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...

Standardized MRI-CT Hybrid Workflow for High-Dose-Rate Image-Guided Adaptive Brachytherapy in Cervical Cancer: Aapm TG-303 Implementation

Authors: Kim Creach, Kim Howard, Julius G. Ojwang, Richard A. Shaw, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: To present a standardized MRI-CT hybrid workflow for High-Dose-Rate (HDR) Image-Guided Adaptive Brachytherapy (IGBT) in cervical cancer, aligned with AAPM TG-303, as a model to assist with im...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Streamlining Quality Control for Radiographic and Fluoroscopic Systems

Authors: Caroline Cheney, Patricia G Collins, Allen R. Goode, Preston Le, Andrew M. Polemi, Angela Snyder

Affiliation: UVA Health, Atirix Medical Systems

Abstract Preview: Purpose: Optimize ongoing quality control (QC) for radiographic (DR) and fluoroscopic (FL) systems by identifying metrics most sensitive to hardware disruptions among regional noise, pooled noise, sig...

Target Region-Specific Dose-Volume Parameters for Estimate of Brain Toxicity in Single-Isocenter Multiple-Metastases Linac-Based Stereotactic Radiosurgery

Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue

Affiliation: NYU Langone Health

Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...

Task Specific Image Quality Assessment Using Spectral Photon-Counting CT.

Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...

Testing the Performance of Rbe Models Using a Comprehensive Panel of Pancreatic Cancer Cell Lines

Authors: Joana Antunes, Scott James Bright, David B. Flint, Mojtaba Hoseini-Ghahfarokhi, Mandira Manandhar, Poliana Marinello, Gabriel O. Sawakuchi, Tingshi Su

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Laboratory of Instrumentation and Experimental Particle Physics; Faculty of Science of University of Lisbon, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, MD Anderson Cancer Center

Abstract Preview: Purpose: To study the accuracy of relative biological effectiveness (RBE) models to predict the RBE of a comprehensive panel of pancreatic cancer cell lines.

Methods: Clonogenic cell survival w...

The Comparison of Radiation Uses in Common Procedures Amongst Didactic Pediatric Fluoroscopic Units

Authors: Janet Ching-Mei Feng, Jimmy Huynh

Affiliation: UTHealth McGovern Medical School

Abstract Preview: Purpose: The Image Gently Alliance had provided helpful information to optimize image protocols in pediatric patients since 2007, and our assumption was that newer units could use near-to-optimal prot...

The Dosimetric and Dose RATE Characteristics for Bragg Peak Proton MINI-Ridge Filter Flash in Comparison to Conventional Proton and Filter Free Flash for Breast and Prostate

Authors: Jenghwa Chang, Chingyun Cheng, J Isabelle Choi, Muhammad Hamza, Minglei Kang, Tyler Kaulfers, Grant Lattery, Haibo Lin, Charles B. Simone, Xingyi Zhao

Affiliation: Peking University, Hofstra University Medical Physics Program, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Physics and Astronomy, Hofstra University, Physics Resident at Montefiore Einstein, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: In terms of high dose rate FLASH, the question remains on how to properly deliver treatment and what clinical sites are feasible to deliver such treatment. The novel Bragg peak (BP-FLASH) and...

Through in-House Software and Customized Phantom to Perform and Analyze Daily Quality Assurance of Proton Treatment System More Efficiently and Monitor the Stability of Its Performance

Authors: Liang-Hsin Chen, Li-Chien Wei

Affiliation: National Taiwan University Cancer Center

Abstract Preview: Purpose: For proton therapy treatment, it is essential to ensure that the treatments are delivered safely and accurately. Quality assurance (QA) programs of proton treatment system is needed and proto...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Treatment Plan Evaluation of the Patient-Tailored Architect Applicator for Cervical Cancer Brachytherapy

Authors: Jenny Dankelman, Ben J. M. Heijmen, Inger-Karine K. Kolkman-Deurloo, Remi A. Nout, Linda Rossi, Robin Straathof, Linda Wauben, Henrike Westerveld, Nick J. van De Berg, Sharline M. van Vliet - Perez

Affiliation: Department of BioMechanical Engineering, Delft University of Technology, Department of Gynecological Oncology, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam

Abstract Preview: Purpose:
To quantify the dosimetric advantages of the 3D-printed patient-tailored ARCHITECT applicator with optimized needle channel configurations compared to clinically used intracavitary/interst...

Ultrasonic Detection of Flash-Level Dose Pulses from a Medical Linac

Authors: Fred B. Bateman, Ilaria M. Luna, Ronald E. Tosh

Affiliation: Sidwell Friends School, NIST, Dosimetry Group, Radiation Physics Division, National Institute of Standards and Technology

Abstract Preview: Purpose: To exploit the rapid response time and dose sensitivity of ultrasonic detection methods for resolving pulse structure in FLASH-level beams.

Methods: Two ultrasonic transducers position...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Using Multi-Peak Reconstructions for Dosimetry of Fast and Quantitative Lutetium-177 SPECT/CT

Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija

Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging

Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...

Utilizing Bladder Ultrasound to Estimate on-Table Bladder Volume in Prostate Cancer SBRT: Impact on Treatment Setup Consistency and Dosimetric Outcomes

Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...

Validation of a Novel Dielectric Layer-Based Detector for Linear Accelerator Quality Assurance

Authors: Dong Wook Kim, Jin Sung Kim, Dongho Lee, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Korea, Republic of (South)

Abstract Preview: Purpose:
This study aims to analyze the characteristics of a novel detector based on a dielectric layer (Vieworks Co., Korea), which demonstrates high tolerance to high radiation doses and light tr...