Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...
Authors: Bas W. Raaymakers, Mario Ries, Paris Tzitzimpasis, Cornel Zachiu
Affiliation: Department of Radiotherapy, University Medical Center Utrecht, University Medical Center Utrecht, UMC Utrecht
Abstract Preview: Purpose: Radiation pneumonitis affects approximately 10-30% of lung cancer patients treated with radiation therapy (RT), posing a significant dose-limiting factor. Recently developed CT-ventilation me...
Authors: Phillip Cuculich, Geoffrey D. Hugo, Xiwen Li, Michael T. Prusator, Clifford Robinson, Pamela Samson, Xue Wu
Affiliation: Washington University School of Medicine in St Louis, Washington University School of Medicine in St. Louis, University of Utah, WashU Medicine
Abstract Preview: Purpose:
For development of novel motion management methods it is useful to have a digital phantom capable of realistic simulation of respiratory 4DCT acquisition of the thorax, including cycle-to-...
Authors: Phillip Cuculich, Geoffrey D. Hugo, Xiwen Li, Michael T. Prusator, Clifford Robinson, Pamela Samson, Xue Wu
Affiliation: Washington University School of Medicine in St Louis, Washington University School of Medicine in St. Louis, University of Utah, WashU Medicine
Abstract Preview: Purpose: Stereotactic arrhythmia radiotherapy (STAR) requires compensation for both respiratory and cardiac motions of the heart. Respiratory 4DCT scans implicitly include cardiac motion and cycle-to-...
Authors: Jee Suk Chang, Hojin Kim, Jin Sung Kim, Jaehyun Seok
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Integrative Medicine
Abstract Preview: Purpose: This study aims to leverage 3D dose distribution data to develop a machine learning model capable of accurately predicting lymphedema occurrence in patients undergoing 3D conformal radiation ...
Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor
Affiliation: Oregon Health & Science University, Northwest Medical Physics Center
Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...
Authors: Edward Robert Criscuolo, Chenlu Qin, Deshan Yang, Zhendong Zhang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose:
Low-dose CT (LDCT) imaging minimizes radiation exposure but introduces significant noise, compromising image quality. While deep learning-based denoising models such as HFormer achieve sta...
Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng
Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center
Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...
Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin
Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center
Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...
Authors: Sarah Aubert, Leigh Conroy, Tony Tadic
Affiliation: Princess Margaret Cancer Centre
Abstract Preview: Purpose: Cardiac radioablation is an emerging non-invasive treatment option for patients with refractory or life-threatening ventricular tachycardia (VT), however it is difficult to deliver highly con...
Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda
Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xiβan Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xiβan Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...
Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai
Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...
Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni
Affiliation: Mercy Hospital Springfield
Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...