Search Submissions 🔎

Results for "90y radioembolization": 15 found

A Novel Method for Virtual Extension of Image-Derived Vasculature Segmentations

Authors: Raneem Atta, Alejandro Bertolet, Mislav Bobić, Wesley E. Bolch, Robert Joseph Dawson, Carlos Huesa-Berral, Harald Paganetti, Eric Wehrenberg-Klee

Affiliation: Massachusetts General Hospital, University of Florida, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Representations of intra-organ vasculature have a variety of uses in the field of computational dosimetry but generally rely on models derived from population-averaged reference individuals. ...

Assessment of Alpha-Fetoprotein As a Prognostic Factor of Overall Survival for HCC Patients Undergoing 90Y-Glass Trans-Arterial Radioembolization

Authors: Srinivas Cheenu Kappadath, James Long, Armeen Mahvash, Anna Marks, Ajalaya Teyateeti

Affiliation: Mahidol University, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Alpha-fetoprotein (AFP) has been implicated as prognostic factor of overall survival (OS) for hepatocellular carcinoma (HCC). We present a statistical approach to determine optimal AFP-cut...

Backward Photon Monte Carlo Propagator (BPMCP): Proof of Concept of a Fully Physics-Driven SPECT Reconstruction

Authors: Alejandro Bertolet, Carlos Huesa-Berral, Victor V. Onecha

Affiliation: Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Radioembolization for liver tumors using 90Y microspheres uses SPECT as confirmatory dosimetry, although 90Y is a pure β-emitter, and SPECT-imaging is only available through subsequent bremss...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Clinically Tenable Lung Dose Estimates in Y-90 Radioembolization from Truncated Maa-SPECT/CT with Unknown Lung Mass

Authors: Dan Giardina, John Karageorgiou, Chris Malone, Naganathan Mani, Allan Thomas

Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Relative to planar imaging, MAA-SPECT/CT offers more reliable lung shunt fraction (LSF) and lung mean dose (LMD) estimates in 90Y radioembolization. But lung truncation in SPECT/CT can limit ...

Comparitive Case Analysis of Maa Mapping and Angiographic Iodinated Contrast for Y-90 SIRT Treatment Planning

Authors: Shengwen Deng, Sven L. Gallo, Robert S. Jones, David W. Jordan, Arashdeep Kaur, Aishwarya M. Kulkarni, Quibai Li, William R.M. Pedersen

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center, Department of Radiology, Radiation Safety, University Hospitals Cleveland Medical Center; School of Medicine, Case Western Reserve University; Department of Radiology, Louis Stokes Cleveland VA Medical Center

Abstract Preview: Purpose:
Y-90 (Yttrium) SIRT radioembolization takes advantage of delivering localized radiation to the liver. Pre-treatment dosimetry is highly dependent on accurate MAA mapping, which may have an...

Evaluate a Deep-Learning Auto-Segmentation Software for Liver SIRT

Authors: Wookjin Choi, Jun Li

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Resin Yttrium-90 (Y-90) selective internal radiation therapy (SIRT) is a radioembolization procedure which uses Y-90 microspheres to treat metastatic liver cancer. In the procedure, liver vol...

Impact of Time-of-Flight Reconstruction and Motion Correction on PET-Based Dosimetry in 90y Radioembolization for Hepatocellular Carcinoma

Authors: Spencer Behr, Joseph Grudzinski, Youngho Seo, Jaehoon Shin, Yiran Wang, Frederick J. Wilson

Affiliation: University of California San Francisco, University of California, San Francisco, Voximetry, Inc., Voximetry, Inc

Abstract Preview: Purpose: Voxel-level imaging-based dosimetry enables a significant improvement in accurate and personalized treatment planning in radiopharmaceutical therapy, potentially leading to optimized disease ...

Impact of Tumor-to-Normal Ratio and Glass Microsphere Particle Density on Local Progression-Free Survival Following Lobar Yttrium-90 Radioembolization

Authors: Jason Chiang, Magnus Dahlbom, Veronica Hankil, Xinyi Li, Catherine (Caffi) Meyer, Kyung Hyun Sung

Affiliation: UCLA, University of California, Los Angeles

Abstract Preview: Purpose:
Yttrium-90 (90Y) radioembolization is a well-established therapy for large or multifocal liver tumors. Accurate dosimetry is critical but remains challenging, as low particle density risks...

Influence of Treatment Site on Lung Shunt Fraction Estimation in 90y-Radioembolization Planning: Comparison of Planar and SPECT Imaging-Based Quantification

Authors: Lukas M. Carter, Jazmin Schwartz

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Accurate lung shunt fraction (LSF) estimation is essential for the safety and efficacy of 90Y-radioembolization therapy. This study compares planar gamma camera imaging and tomographic SPECT-...

Just-in-Time Quality Assurance Check for Yttrium-90 Radioembolization Therapy

Authors: Stewart J. Becker, Andrew Genuit, Mariana Guerrero, Yannick P. Poirier

Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: To introduce an additional quality assurance step to prevent human error in vial mix-ups during Yttrium-90 (Y90) radioembolization by verifying the local assay at the time of delivery. We pro...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Radiation Sub-Segmentectomy in 90y Radioembolization: Post-Therapy Dosimetry, Treatment Response, and Pathological Necrosis

Authors: Guilherme Rosa Ferreira, Dan Giardina, John Karageorgiou, Chris Malone, Allan Thomas

Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Radiation segmentectomy has become a primary strategy in 90Y radioembolization, with localized treated volumes that can include up to two liver segments. The goal is complete pathological nec...

Using Contrast-Enhanced Computed Tomography for Non-Invasive Lung Shunt Fraction Prediction in Yttrium-90 Radioembolization

Authors: Roger Eric Goldman, Adrianna Imani Johnson Carter, Talia Marx, Brahim Mehadji, Emilie Roncali, Catherine T. Vu

Affiliation: UC Davis, Department of Radiology, UC Davis Health

Abstract Preview: Purpose:
Accurate estimation of the Lung Shunt Fraction (LSF) is critical for yttrium-90 (90Y) radioembolization treatment planning to minimize risks of excessive lung irradiation due to arterio-ve...

Voxel-Dose Implications of Single-Compartment Dosimetry for Ablative 90Y-Radioembolization Segmentectomy

Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...