Authors: Hector Andrade-Loarca, Ines Butz, Chiara Gianoli, Prof. Gitta Kutyniok, Jianfei Li, Katia Parodi, Prof. Vincenzo Patera, Angelo Schiavi, Prof. Ozan Öktem
Affiliation: Sapienza University of Rome, Department of Mathematics, Royal Institute of Technology, School of Computation, Information and Technology, Technische Universitaet Muenchen, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Mathematics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München
Abstract Preview: Purpose: To explore and demonstrate the feasibility of accurate and fast prediction of the water equivalent thickness (WET) distribution of tissue traversed by a proton imaging pencil beam, aiming at ...
Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...
Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie
Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU) München
Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...
Authors: Niels Bassler, Jonathan Bortfeldt, Francesco Evangelista, Giulio Lovatti, Jasper Nijkamp, Rasmus Nilsson, Munetaka Nitta, Katia Parodi, Marco Pinto, Per R. Poulsen, Brita Singers Sørensen, Peter Thirolf, Erik Traneus, Taiga Yamaya
Affiliation: RaySearch Laboratories AB, National Institutes for Quantum Science and Technology, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: Within the SIRMIO project (Small Animal Proton Irradiator for Research in Molecular Image-Guided Radiation Oncology), we aimed to perform the first in vivo proton beam treatment with a dedica...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl
Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam
Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.
Methods:...
Authors: Katia Parodi
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: N/A...
Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...