Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Cross-Calibration and Comparison of CT Number to Electron Density Using Two Calibration Phantoms

Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...

Determine Noise Weighting Factor in Photon-Counting CT Via Deep Learning for Personalized Noise Reduction

Authors: Xinhui Duan, Roderick W. McColl, Mi-Ae Park, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: UT Southwestern Medical Center, Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Image-based deep-learning noise-reduction techniques have been developed for photon-counting CT (PCCT) to improve image quality with reduced radiation dose. The denoising strength is typic...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Evaluation of Noise and Dose Efficiency in Clinical Photon-Counting CT Colonography with Tin Prefiltration

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Vasantha Vasan, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: Minimizing radiation dose is crucial in CT colonography (CTC) screening and diagnosis. Tin (Sn) prefiltration is readily incorporated into clinical photon-counting CT (PCCT) scanners, yet its...

Impact of Patient Size on the Choices of Dual and Single Energy CT for Accurate Liver Fat Volume Fraction Quantification

Authors: Xinhua Li, Jie Zhang, Yifang (Jimmy) Zhou

Affiliation: University of Kentucky, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. CT can be a good modality for FVF assessment if the accuracy is adequate. We aimed to study the impa...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Tin-Filtered Spectral Shaping Technique in Clinical Photon-Counting CT: Impact on Noise Magnitude By Object Size, Radiation Dose, and Spectral Reconstruction Type

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate how tin-filtered spectral shaping in clinical photon-counting computed tomography (PCCT) affects noise magnitude across varying object sizes, radiation doses, and spectral reconst...