Search Submissions 🔎

Results for "accelerator output": 16 found

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

A Risk Assessment Approach to Photon Reference Dosimetry Using TG-100 Methodology

Authors: Ila Farhang, Ryan D. Foster, Devin Heitz, Jordan B Lunsford, Ashkan Shafiee

Affiliation: Atrium Health Wake Forest Baptist, Atrium Health/LCI Cabarrus

Abstract Preview: Purpose: American Association of Physicists in Medicine (AAPM) Task Group (TG) -51 is a widely utilized protocol for the absolute calibration of linear accelerators. The purpose of this project was fo...

Applicability of Online Dose Measurement in Trilogy Linear Accelerators: Using Target Current Pulse Counting Method

Authors: Daming LI, Jinsen Xie, Zhe Zhang

Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China

Abstract Preview: Purpose:
This study aims to investigate the feasibility of online dose measurement of the Trilogy linear accelerator output based on target current pulse signals.
Methods:
A data acquisition ...

Application of a Flashdiamond Detector Coupled to a Beam Current Transformer to Commission a Monte Carlo Model of a Ultra-High Dose Rate Electron Beam

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal

Abstract Preview: Purpose:
To validate a Monte Carlo (MC) model of a Ultra-High dose rate (UHDR) electron beam using a prototype flashdiamond (fD) detector coupled to an electrostatically shielded beam current trans...

Cherenkov Image Denoising with Diffusion-Based Deep-Learning for High-Fidelity Video Display of EBRT

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue, Yucheng Tang, Shiru Wang

Affiliation: NVIDIA Corp, Dartmouth College, Thayer School of Engineering, Dartmouth College, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: Cherenkov imaging allows for real-time visualization of megavoltage X-ray or electron beam delivery during radiation therapy. By using a time-gated intensified CMOS camera synchronized with a...

Cycle-Consistent Multi-Task Automated Segmentation and Synthetic CT Generation Model for Adaptive Proton Therapy

Authors: Derek Tang, Susu Yan

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To evaluate the performance of a multi-task automated-segmentation and synthetic CT generation model (sCT) and investigate its application in an adaptive proton therapy workflow.
Methods: ...

Design and Testing of an External Control System for Beam Control and Pre-Delivery Optimization for Conventional- and Ultra-High-Dose-per-Pulse Flash Irradiations

Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler

Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...

Evaluating Pulse Normalization for Enhanced Ion Chamber Signal Correction in Relative Dosimetry during Beam Scanning

Authors: Alejandro Cuadra, Paulina E. Galavis, Juan Leal, Enrique Lozano, Franklin Reggio, Gabriel Zelada

Affiliation: Clínica Iram, Clinica Alemana, Hospital Clínico de Magallanes, E&G Medical Systems Ltda, NYU Langone Health

Abstract Preview: Purpose: To investigate and compare the new method “Pulse Normalization” proposed by Sun Nuclear to correct ion chamber signal for fluctuations in the accelerator output while performing relative dosi...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Experience in Commissioning and Quality Assurance of Halcyon Linear Accelerator Ver3.0 at a Community Hospital and an Academic Institution

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose:
The Varian Halcyon Linear Accelerator has become increasingly popular in both community hospitals and academic institutions due to its user-friendly design and operational efficiency. This...

Feasibility of Producing GRID Therapy Dosimetry Using a Compact Linac Treatment Head with Pencil Beam Scanning

Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin

Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

Impact of Beamline Mis-Adjustment Following Central Beamline Replacement for Halcyon Linear Accelerator

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose: Introduced in 2018, the Varian Halcyon platform has increased in popularity due to its reduced cost, user-friendly design, and operational efficiency. As this platform ages, major repairs, in...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

Mobetron Quality Assurance Tools

Authors: Robert A. Dahl

Affiliation: Mayo Foundation

Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.

Methods: The Mobet...

Research on the Target Current Pulse Counting Method for Measuring the Output Dose of Medical Standing Wave Electronic Linear Accelerator

Authors: Shixiong Huang, Daming Li

Affiliation: The Affiliated Nanhua Hospital, University of South China, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital

Abstract Preview: Purpose: To assess the feasibility of using target current pulse signals to evaluate the output dose of medical standing wave electronic linear accelerators.
Methods: The Target I signal of the acc...