Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White
Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ
Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...
Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...
Authors: Jie Deng, Xiaoxue Qian, Hua-Chieh Shao, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Based on a 3D pre-treatment MRI scan, we developed DREME-MR to jointly reconstruct the reference patient anatomy and a data-driven, patient-specific cardiorespiratory motion model. Via a moti...
Authors: B. Gino Fallone, Keith D. Wachowicz, Mark G. Wright, Jihyun Yun
Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com
Abstract Preview: Purpose: This work focusses on a hybrid Principal Component Analysis (PCA) based MR acceleration method for prospectively acquired undersampled data on a hybrid MR-Linac system for real-time target-tr...
Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...
Authors: Zachary Buchwald, Chih-Wei Chang, Zach Eidex, Richard L.J. Qiu, Mojtaba Safari, Shansong Wang, Xiaofeng Yang, David Yu
Affiliation: Emory University and Winship Cancer Institute, Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: MRI offers excellent soft tissue contrast for diagnosis and treatment but suffers from long acquisition times, causing patient discomfort and motion artifacts. To accelerate MRI, supervised d...
Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei
Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington
Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...
Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang
Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center
Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...
Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...
Authors: Ivan M. Buzurovic, Phillip M. Devlin, Evangelia Kaza, Michael John Lavelle
Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Recent work in surface brachytherapy (SBT) has demonstrated the feasibility of using magnetic resonance (MR)-guidance in place of Computer Tomography (CT) in SBT planning. The purpose of this...
Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...
Authors: Morgan A. Daly, David J. Goodenough, Andrew M. Hernandez, John M. Hoffman, Joshua Levy, Michael F. McNitt-Gray, Ali Uneri, Bino Varghese
Affiliation: University of California, George Washington University, David Geffen School of Medicine at UCLA, Johns Hopkins Univ, University of Southern California, The Phantom Laboratory
Abstract Preview: Purpose: Quantitative imaging is affected by CT acquisition and reconstruction conditions, limiting robustness in multi-site or -scanner studies. This work aimed to develop a dataset that will enable ...
Authors: Hyo-Min Cho, Changwoo Lee
Affiliation: Korea Research Institute of Standards and Science
Abstract Preview: Purpose: We develop sphere phantoms to assess spatial resolution of computed tomography (CT) systems and validate its usability using table-top X-ray experiment systems.
Methods: We manufactured sp...
Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China
Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...
Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang
Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute
Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yabo Fu, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Boris Mueller, Huiqiao Xie, Mitchell Yu, Hao Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Gating ablative radiotherapy for pancreatic cancer accounts for tumor movement due to respiration and typically requires 5, 15, or 25 fractions. Pretreatment imaging verification is essential...
Authors: Mengqi Shen, Meghna Trivedi, Tony J.C. Wang, Andy (Yuanguang) Xu, Yading Yuan
Affiliation: Columbia University Medical Center, Dept of Med Hematology & Oncology, Data Science Institute at Columbia University, Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: T2-weighted (T2w) images are critical for identifying pathological changes due to their superior contrast in differentiating tissue types. However, they often lack detailed anatomical resolut...
Authors: Yi-Fang Wang, Yading Yuan
Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...
Authors: Xiaoyu Duan, Xinyu Hu, Runqiu Li, Xiang Li
Affiliation: Dukekunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Accurate detection of small-sized microcalcifications (μCalcs) (< 500 µm) is critical for early breast cancer diagnosis, requiring optimal imaging systems and reconstruction algorithms. Ho...
Authors: Fan Liu, Adam C. Riegel, Yi-Fang Wang
Affiliation: Columbia University Irving Medical Center
Abstract Preview: Purpose: HyperSight, Varian Medical Systems' latest CBCT technology, integrates rapid 6-second data acquisition with advanced iterative reconstruction, enabling precise real-time contouring and dose c...
Authors: Laura Bennett, Matthew Charles, Greg Cooley, John M. Floberg, Ryan Hutten, Elissa Khoudary, Nicholas Lynch, Kaili Ranta, Jordan M. Slagowski, Trevor Wilson
Affiliation: University of Pennsylvania, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, University of Wisconsin-Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: To evaluate the impact of an iterative cone beam CT with metal artifact reduction (iCBCT+MAR) reconstruction algorithm (HyperSight TrueBeam 4.1, Varian Medical Systems) on image quality and s...
Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl
Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam
Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.
Methods:...
Authors: Ming Chao, Karyn A Goodman, Yang Lei, Tian Liu, Jing Wang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose: Real-time volumetric MRI is essential for motion management in MRI-guided radiotherapy (MRIgRT), yet acquiring high-quality 3D images remains challenging due to time constraints and motion ar...
Authors: Njood Alsaihati, Ehsan Samei, Justin B. Solomon
Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Inconsistent imaging procedure naming across and within institutions challenges clinical decision-making, quality assessment, and data analysis in radiology. For example, The American College...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: This study introduces a novel spatiotemporal Gaussian neural representation framework to reconstruct high-temporal dynamic CBCT images from 1-minute acquisition, preserving motion dynamics an...
Authors: Cheryl Anderson, Lara Best, Amanda Cherpak, Jennifer DeGiobbi, Marc C. LeBlanc, R. Lee MacDonald, Peter R. Martin, Natasha McMaster, Murali Rajaraman, James L. Robar, Lucy Ward, Derek Wilke, Kenny Zhan
Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health
Abstract Preview: Purpose: This work investigates the potential benefit of adaptive planning using the Ethos radiotherapy system (Varian Medical Systems) with direct-dose calculation on HyperSight cone beam CT (CBCT) f...
Authors: Wendy Siman, Wei Zhou
Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine
Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-µm tungsten wire was imaged at ...
Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds
Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University
Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...
Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez
Affiliation: University of Houston, UT MD Anderson Cancer Center
Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...
Authors: Gregory J Bootsma, Tunok Mondol
Affiliation: University Health Network, Princess Margaret Cancer Center
Abstract Preview: Purpose:
To evaluate the impact of prototype fluence field modulation (FFM) cone-beam CT (CBCT) on dose reduction and image quality using Monte Carlo simulations. This study particularly looks at t...
Authors: Daniel O Connor, Mary Feng, Hui Lin, Hengjie Liu, Xin Miao, Michael Ohliger, Jess E. Scholey, Ke Sheng, DI Xu, Wensha Yang, Yang Yang
Affiliation: UCSF, University of California, Los Angeles, Department of Radiation Oncology, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, University of California at San Francisco, University of San Francisco, Department of Radiology, University of California, San Francisco, University of California San Francisco, Siemens Medical Solutions USA Inc.
Abstract Preview: Purpose: The scanning time for a fully sampled MRI is lengthy. Compressed sensing (CS) has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is...
Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu
Affiliation: University of California, Irvine, University of California Irvine
Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...
Authors: Hao Chen, Kai Ding, Xiaoyu Hu, Xun Jia, Heng Li, Devin Miles
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Accurately delivering radiation dose is critical in intensity-modulated proton therapy (IMPT), where intrafraction motion management plays a pivotal role. Our proton therapy system equipped x...
Authors: Karyn A Goodman, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Qian Wang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Beth Israel Deaconess Medical Center
Abstract Preview: Purpose: Accurate motion management in MRI-guided radiotherapy (MRIgRT) relies on real-time volumetric MRI to track intra-fractional anatomical changes. Dense k-space sampling, while capable of produc...
Authors: Teh Lin, Anna Oneil
Affiliation: Fox Chase Cancer Center
Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...
Authors: Yong Du
Affiliation: Department of Radiology, Johns Hopkins University
Abstract Preview: N/A...
Authors: Mary Feng, Yi Lao, Hui Lin, Hengjie Liu, Xin Miao, Michael Ohliger
Affiliation: University of California, Los Angeles, Department of Radiation Oncology, University of California San Francisco, Department of Radiation Oncology, City of Hope National Medical Center, University of California San Francisco, Siemens Medical Solutions USA Inc.
Abstract Preview: Purpose: 4D MRI with high spatiotemporal resolution is vital to characterize the tumor/tumor motion for liver radiotherapy. However, high-quality 4D MRI requires an impractically long scanning time fo...
Authors: David P. Adam, Xun Jia, Youfang Lai, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University
Abstract Preview: Purpose: Radiopharmaceutical therapy is experiencing a resurgence in interest due to its potential of treating widespread metastatic disease in a patient-specific manner. Accurately measuring and desc...
Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang
Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill
Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...
Authors: Geoffrey D. Hugo, Eric Laugeman, Thomas R. Mazur, Pamela Samson, Kim A. Selting, Zhehao Zhang
Affiliation: University of Illinois, Washington University in St. Louis School of Medicine, WashU Medicine
Abstract Preview: Purpose: To investigate the robustness of a deep learning (DL)-based 4D-CBCT motion-compensated (MoCo) reconstruction method to out-of-distribution data.
Methods: Our developed 4D-CBCT reconstructi...
Authors: Hilary Louisa Byrne, Paul J. Keall, John Kipritidis, Jeremy Lim
Affiliation: Northern Sydney Cancer Centre, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose:
Non-contrast CT ventilation imaging (CTVI) has been developed as a cost-effective and accessible alternative to PET/SPECT V/Q imaging for visualizing lung function. However, the sensitivit...
Authors: Hua-Chieh Shao, Shanshan Tang, Jing Wang, Kai Wang, You Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: Artifacts caused by gas bubble movement in the gastrointestinal tract can severely degrade the image quality of on-board abdominal cone-beam computed tomography (CBCT), impacting its utility ...
Authors: Trevor McKeown, Deshan Yang, Zhendong Zhang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: Accurate delineation of liver blood vascular structures is crucial for planning and executing therapeutic interventions in liver-related medical procedures. However, current auto-segmentation...
Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu
Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center
Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...
Authors: Owen Thomas Dillon, Andrew Kanawati, Tess Reynolds
Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose: Metal artefacts from implanted hardware and surgical tools remain a limitation for widespread adoption of intraoperative CBCT imaging. Gantry-based non-circular imaging trajectories have emer...
Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija
Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging
Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...