Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun
Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...
Authors: Christina Brunnquell, Daniel Vergara, Joseph Everett Wishart
Affiliation: University of Minnesota, University of Washington
Abstract Preview: Purpose: To propose and validate a correction to the bandwidth difference method presented in Task Group Report No. 325 for quantifying static magnetic field homogeneity (ΔB0).
Methods: A clarifica...
Authors: Tina Ehtiati, Grace Jianan Gang, Limei Ma, Oleg Shekhtman, Visish M. Srinivasan
Affiliation: Siemens Medical Solutions USA, Inc., University of Pennsylvania
Abstract Preview: Purpose: Saccular aneurysms are the most common type of intracranial aneurysm and are typically treated by endovascular embolization. The procedure requires approximately orthogonal fluoroscopy images...
Authors: Jie Liu
Affiliation: Inova Health System
Abstract Preview: Purpose:
The respiratory signal commonly acquired by using external surrogates or detecting the diaphragm position only represents the phase information and has poor correlation with the tumor moti...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose: The objective of this study is to systematically evaluate and validate the performance of a commercially available 3D Linear stage device as a quality assurance (QA) tool to validate position...
Authors: Fangfen Dong, Jiaming Li, Xiaobo Li, Weipei Wang, Zhixin Wang, Bing Wu, Benhua Xu, Yong Yang, Yifa Zhao
Affiliation: Department of Radiation Oncology, Fujian Medical University Union Hospital/Fujian Key Laboratory of Intelligent Imaging and Precision Radiotherapy for Tumors/Clinical Research Center for Radiology and Radiotherapy of Fujian Province (Digestive, Hematologi, Zhangpu County Hospital, School of Medical Imaging, Fujian Medical University
Abstract Preview: Purpose: To explore the construction and clinical application value of a deep learning-based positioning error prediction model, providing a reference for optimizing iSCOUT system-guided precision rad...
Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma
Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC
Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...
Authors: Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Michael Leyva, Alejandro Rene Llanes Lopez, William Romaguera, Ranjini P. Tolakanahalli, Deborah Wang
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health
Abstract Preview: Purpose: To evaluate whether a modulated electron bolus (MEB) technique improves both nominal and shifted dose distributions in nasal electron therapy as compared to a non‑modulated, uniform‑thickness...
Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard
Affiliation: Warren Alpert Medical School of Brown University
Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...
Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...
Authors: Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura, Yukine Shimizu
Affiliation: Kyoto University, Kyoto Univercity, Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To predict tumor positions in markerless dynamic tumor tracking (ML-DTT)-VMAT by compensating for the asynchrony between the tumor and the diaphragm.
Methods: Rotational fluoroscopic X-ray...
Authors: Ling Chen, Alexei V. Trofimov, Yi Wang, Dufan Wu
Affiliation: Massachusetts General Hospital, MGH
Abstract Preview: Purpose:
Selecting gaze angles of the eye is an important part of set-up of proton therapy for ocular tumors, ensuring that the treatment beam could irradiate the tumor while maximally sparing impo...
Authors: John Ginn, Chenlu Qin, Deshan Yang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: Clinical implementation of auto-segmentation tools has been hindered by poor interpretability and generalizability of AI models, necessitating the development of automated contour quality ass...
Authors: Peter Jermain, Ying Niu, Abdul Rashid, Yuan Yuan, Mohammad Zarenia
Affiliation: Medstar Georgetown University Hospital, MedStar Georgetown University Hospital, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose: ZAP-X is a self-shielded radiosurgery system that utilizes a linac-based isocentric technique and a compact gyroscopic gantry design. While it provides a large solid angle for beam orientatio...
Authors: Matthew R. Hoerner, Allison Shields
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose: To investigate the quality and clinical utility of chest x-rays synthesized from CT scans (sCXR).
Methods: Five helical chest CT exams were chosen for evaluation: this cohort represented a...
Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...
Authors: Yunfei Dong, Dongyang Guo, Jiongli Pan, Tao Peng, Caiyin Tang, Zhenyu Yang, Fang-Fang Yin, Lei Zhang, Tianyi Zhang, Yaogong Zhang
Affiliation: Duke Kunshan University, Department of Radiology, Taizhou People’s Hospital Affiliated to Nanjing Medical University, School of Future Science and Engineering, Soochow University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: This study aims to improve the accuracy of CT-based diagnosis of thyroid cancer by developing a hybrid model that integrates Convolutional Neural Networks (CNNs) with Long Short-Term Memory (...
Authors: Weiliang Du
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Winston-Lutz (WL) tests are often used to localize the radiation isocenter of a linac. The selection of gantry and collimator angles can affect the accuracy of the resulting isocenter. The ef...
Authors: Jian Chen, Qiufen Guo, Aihua Li, Jing Liu, Junjie MA, Qian WU, Haonan Xiao, Peng Xie, Xiaohui Yan, Yong Yin, Zhe Zhang
Affiliation: Department of Radiation Oncology, Peking University Shenzhen Hospital, Department of Radiation Oncology and Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Obstetrics and Gynaecology, Liao Cheng People’s Hospital
Abstract Preview: Purpose: Online Adaptive radiation therapy (ART) has been an effective technique to manage patient’s inter-fractional anatomical changes and therefore reduces planning target volume (PTV). However, on...
Authors: Tianliang Gu
Affiliation: UT Health Science Center at Houston
Abstract Preview: Purpose:
In Nuclear Regulatory Commission guide 8.39 on releasing patients administered radioactive material, the dose is calculated assuming both the source and receiver are points. This point mod...
Authors: Chris Beasley, Ngara Linda Bird, Flora Ivanova, Erin B. Macdonald, Lauren M. Neldner, Beth Reed, Scott H. Robertson
Affiliation: School of Medicine, Duke University, Duke University, Duke University Health System
Abstract Preview: Purpose: To develop a hands-on, data-driven educational program to improve MRI technologists' understanding and effective use of ferromagnetic detecting (FMD) wands.
Methods: A 30-minute interactiv...
Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi
Affiliation: Komazawa University Graduate School, St. Luke's International Hospital
Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...
Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, Humberto Monsivais, John Rong
Affiliation: Purdue University, UT MD Anderson Cancer Center
Abstract Preview: Purpose: To investigate the noise characteristics of a clinical photon counting detector CT (PCD-CT) system along axial and through-plane (Z) dimensions using 3D NPS measurements.
Methods: This stu...
Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: Conventional computed tomography (CT) measures the collective attenuation of primary photon fluence and then reconstructs the 3D images without using the timing information of individual phot...
Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...
Authors: Yi An, David J. Carlson, Zhe (Jay) Chen, Jun Deng, Dae Yup Han, Sameer Taneja
Affiliation: Yale School of Medicine, Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: Spine Stereotactic radiosurgery (SSR) delivers a large radiation dose and utilizes narrow PTV margins, on the order of 1 mm, to avoid excess dose to the spinal cord. Because of this, intrafra...
Authors: Michael B. Altman, Sharbacha Edward, Jose L. Garcia Ramirez, Anamaria Guta, Elizabeth Gaines Jeong, Justin K. Mikell, Phillip D. H. Wall, Jacqueline Esthappan Zoberi
Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, WashU Medicine
Abstract Preview: Purpose: Modern HDR remote afterloaders (RAL) are equipped with enhanced safety features for accurate source positioning. However, little guidance is provided on the use of these features. We have cli...