Search Submissions 🔎

Results for "angle precision": 19 found

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Novel Device for Radiation Therapy Machine Quality Assurance

Authors: Jonathan Dowell, Grace Francis, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Iridesce Solutions, Inc.

Abstract Preview: Purpose: A novel radiation therapy quality assurance (RT QA) device has been designed, constructed and tested. The nüFilmTM machine QA system provides a method for collecting light, mechanical and rad...

BEST IN PHYSICS MULTI-DISCIPLINARY: Evaluation of Spot-Level N-12 PET Imaging for Online Range Verification in Multi-Field Intensity Modulated Proton Therapy

Authors: Zahra Ahmadi Ganjeh, Stefan Both, Peter Dendooven, Jeffrey Free, Brian Zapien Campos

Affiliation: Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Particle Therapy Research Center (PARTREC), Department of Radiation Oncology, University Medical Center Groningen, University of Groningen

Abstract Preview: Purpose: Positron emission tomography (PET) has been investigated for range monitoring in intensity-modulated proton therapy (IMPT), but real-time feedback been limited due to the focus on long-lived ...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Efficient Monte Carlo Proton Dose Calculation Using Denoising Diffusion Probabilistic Models

Authors: Chieh-Ya Chiu, Shen-Hao Li, Hsin-Hon Lin, Shu-Wei Wu

Affiliation: Department of Medical Imaging and Radiological Sciences, Chang Gung University, Proton and Radiation Therapy Center, Chang Gung Memorial Hospital Linkou

Abstract Preview: Purpose: Monte Carlo simulation enables precise calculation of dose distribution in proton therapy through tracing the radiation particles with patient tissues. However, achieving clinical-level preci...

Enhancement of Adaptive Collimation Precision on Pencil Beam Scanning Proton System

Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang

Affiliation: Levine Cancer Institute, Atrium Health

Abstract Preview: Purpose: To evaluate aperture collimation on a C-shape gantry-mounted proton accelerator. Mevion S250i Hyper scanning machine implemented aperture collimation utilizing adaptive aperture (AA). The AA ...

Enhancing Image Quality in Acoustic Imaging Using the Segment Anything Model (SAM)

Authors: Jadon Buller, Zhuoran Jiang, Yankun Lang, Lei Ren, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of Maryland School of Medicine, University of California, Irvine, University of California, Stanford University

Abstract Preview: Purpose: Electroacoustic tomography (EAT) and Protoacoustic (PA) imaging are novel modalities for treatment verification of electroporation and proton therapy. However, the limited acquisition angle i...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Gaze Angle Selection in Proton Therapy for Ocular Tumors with Machine Learning

Authors: Ling Chen, Alexei V. Trofimov, Yi Wang, Dufan Wu

Affiliation: Massachusetts General Hospital, MGH

Abstract Preview: Purpose:
Selecting gaze angles of the eye is an important part of set-up of proton therapy for ocular tumors, ensuring that the treatment beam could irradiate the tumor while maximally sparing impo...

Improving Stroke Treatment Using Magnetic Nanoparticle Sensors to Monitor Mechanical Thrombectomy

Authors: Clifford Eskey, Scott Gordon-Wylie, Scott Gordon-Wylie, Dhrubo Jyoti, Daniel Reeves, John B. Weaver

Affiliation: Flow Aluminum, Dartmouth College, Fred Hutch Cancer Center, University of Washington, Dartmouth-Health

Abstract Preview: Purpose: Mechanical thrombectomy (MT) is the preferred treatment for ischemic stroke from large vessel occlusion. The thrombus or clot is extracted from the vessel via a catheter using a stent retriev...

Modified Dehazenet for Scatter Correction in Triggered Imaging: Enhancing Visibility and Alignment Precision for Radiation Therapy

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: Scatter in X-ray imaging degrades image quality, hindering the visibility of critical anatomical features and complicating patient alignment in radiation therapy. This study aims to improve s...

Multi-Vendor Linac Isocenter Evaluation: Implications for SRS in Radiotherapy

Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...

Optically Guided Speculum for Needle or Other Probe-Based Interventions in Small Animals

Authors: Michael B. Altman, Marlene Campos Guerrero, Stephanie Markovina, Aaron Silvus

Affiliation: Washington University School of Medicine

Abstract Preview: Purpose: Currently, fluid injections or needle biopsies in small animals are conducted with limited optical guidance introducing an inherent risk of infecting or injuring the animal and limits precisi...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...

The Effect of Radiotherapy Structure Shape Features on the Accuracy of Their Digital Representation and Manipulation

Authors: Annie Cooney, Kenneth L. Homann, Somayeh Taghizadehghahremanloo, Adam D. Yock, Hong Zhang

Affiliation: Assistant Professor, Vanderbilt University Medical Center

Abstract Preview: Purpose:
Digital radiotherapy data has been standardized using the DICOM format. However, different radiotherapy software environments interpret identical data differently due to inherent software ...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...