Search Submissions 🔎

Results for "animal tissues": 20 found

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

Comparing the Rsp Accuracy of a Fast Switching Dual-Energy CT to Single-Energy CT Using Proton CT in Animal Tissue.

Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang

Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine

Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...

Developing and Using Barcode-Reading Type Portable OCT Imaging System to Detect Surgical Margin

Authors: Dukagjin Blakaj, Zhilin Hu, Stephen Kang, Abberly Lott Limbach, Lanchun Lu, Henry Xiang, Jie Zhang

Affiliation: Pharostek, Department of Pediatrics, The Ohio State University, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiology, University of Kentucky, Department of Pathology, The Ohio State University, Department of Radiation Oncology, The Ohio State University, Department of Otolaryngology, The Ohio State University

Abstract Preview: Purpose: Detect surgical margin in vivo using an original barcode-reading type portable OCT imaging system.
Methods: We developed a barcode-reading type portable optical coherence tomography (OCT) ...

Development of an MRI Guided Precision Small Animal Radiotherapy System

Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...

Dosimetric Characterization of Spatial Fractionation Collimator for Ultra-High Dose Rate Electron Beam

Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan

Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center

Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...

EPR Oximetry for Hypoxia Assessment in Deep Tissues Using Oxytrack

Authors: Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: The rigid needle-like EPR sensor, OxyTrack, was developed to provide minimally invasive, reliable, and quantitative measurements of oxygen distribution (pO2) in deep tissues. EPR oximetry's c...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

First In Vivo Proton Beam Irradiation of Mice with Quasi-Real-Time Range Verification with the Sirmio PET Scanner

Authors: Niels Bassler, Jonathan Bortfeldt, Francesco Evangelista, Giulio Lovatti, Jasper Nijkamp, Rasmus Nilsson, Munetaka Nitta, Katia Parodi, Marco Pinto, Per R. Poulsen, Brita Singers Sørensen, Peter Thirolf, Erik Traneus, Taiga Yamaya

Affiliation: RaySearch Laboratories AB, National Institutes for Quantum Science and Technology, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: Within the SIRMIO project (Small Animal Proton Irradiator for Research in Molecular Image-Guided Radiation Oncology), we aimed to perform the first in vivo proton beam treatment with a dedica...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

First in-Vivo Proton Radiography Experiments for an Image-Guided Small Animal Irradiation Platform with a TimePix3-Based Detector Setup

Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl

Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam

Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.

Methods:...

Hyperbaric Oxygen Therapy Prior to SRS Does Not Enhance Radiosensitivity in the Murine Glioblastoma Model

Authors: Beverly Allen, Jay C. Buckey, David J. Gladstone, P. Jack Hoopes, David I Hunter, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, Geisel School of Medicine, Dartmouth College, Geisel School of Medicine, Thayer School of Engineering

Abstract Preview: Purpose: Hyperbaric oxygen (HBO) therapy immediately prior to radiation therapy has been proposed as treatment to enhance radiosensitivity of hypoxic tumors. A murine glioblastoma model was utilized t...

Imaging Preclinical Proton Flash Radiation Using a Small Animal PET System

Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...

Optically Guided Speculum for Needle or Other Probe-Based Interventions in Small Animals

Authors: Michael B. Altman, Marlene Campos Guerrero, Stephanie Markovina, Aaron Silvus

Affiliation: Washington University School of Medicine

Abstract Preview: Purpose: Currently, fluid injections or needle biopsies in small animals are conducted with limited optical guidance introducing an inherent risk of infecting or injuring the animal and limits precisi...

Phase One Randomized Two-Arm Dose Escalation of Flash RT in Veterinary Canine Osteosarcoma: Trial Design & Initial Results

Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...

Preclinical Assessment of Novel Targeted Chelate-Based Radiopharmaceuticals for Aggressive Cancer Detection

Authors: David Alcorta, Joseph Farina, Timothy Haystead, Yiping He, Philip Hughes, David Loiselle, Marybeth Nedrud, Victoria J. P. Radosova, Jianpeng Yu

Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Duke University School of Medicine, Duke Cancer Institute

Abstract Preview: Purpose: Targeted radiopharmaceuticals have become of widespread interest in the scientific community given their ability to detect and treat metastatic disease. We aim to validate the use of novel ch...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Quantitative Fluorescence Molecular Tomography Guide Radiation Therapy

Authors: Jiahao Chen, Yunwen Huang, Yidong Yang, Shanshan Zhang, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a molecular image-guided radiotherapy technique for accurate and effective radiation treatment using quantitative fluorescence molecular tomography (FMT).
Methods: X-ray cone be...

Radiopharmaceutical-Free Assessment of Tumor Vasculature Condition in Particle Therapy By Means of Range-Verification PET: A Feasibility Rat Study

Authors: Go Akamatsu, Han Gyu Kang, Chie Seki, Hitomi Sudo, Hideaki Tashima, Chie Toramatsu, Hidekatsu Wakizaka, Iwao Yamaya, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose:
Tumor oxygen status, which provides important information to optimize particle therapy, may constantly change during a treatment period of several weeks. However, it is impractical to perf...

Recovery Factor Comparisons for Reirradiation Overlapping the Spinal Cord

Authors: Xinxin Deng, Issam M. El Naqa, Jimm Grimm, Lijun Ma, Vitali Moiseenko, Timothy E. Schultheiss, Gopal Subedi, Wolfgang A. Tomé, Ellen D. Yorke, Albert van der Kogel

Affiliation: Montefiore Medical Center, Wellstar Kennestone Hospital Cancer Center, H. Lee Moffitt Cancer Center, Department of Human Oncology, University of Wisconsin–Madison, Department of Radiation Oncology, Wellstar Health System, Radiation Oncology, Keck School of Medicine of USC, Georgia Institute of Technology, University of California San Diego, City Of Hope National Medical Centre, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Reirradiation is increasingly utilized in clinical practice but dose-time recovery factors for human subjects remain uncertain. We constructed a reirradiation recovery model for spinal cord e...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...