Search Submissions 🔎

Results for "anthropomorphic phantoms": 43 found

A Fast Low-Dose Method for Beam Blocker-Based CBCT Scatter Correction

Authors: Yidong Yang, Haolin Zhan

Affiliation: Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a fast low-dose method for beam blocker-based CBCT scatter correction and evaluate image quality in phantom study.
Methods: The full number of scatter projections were collected...

A Novel Design of Photon-Counting Static Cone-Beam CT System for Dedicated Breast Imaging

Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...

A Two-Marker Method for Calculating the Radiological Magnification of the Hip in Standing Pelvic Radiography

Authors: Walaa Abdelfadeel, Reagan Thomas Dugan, Tiffany Kinsey, Cameron Kofler, Zheng Feng Lu, Ingrid S. Reiser, Gregory Stacy, Sara Wallace

Affiliation: University of Chicago Medicine, University of Chicago

Abstract Preview: Purpose: To develop an accurate, vendor-neutral method for estimating geometric magnification at the plane of the hip joint on standing anterior-posterior (AP) radiographs for digital templating of to...

Assessing Low Iodine Concentrations in Liver Lesions with Dual Energy CT: Impact of Beam Choices

Authors: Xinhua Li, Vu Nguyen, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Assessing iodine concentration in liver lesions is essential for evaluating contrast enhancement in multi-phase liver CT and for accurate disease diagnosis. This study aims to evaluate the as...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Breathing New Life into Pulmonary Imaging: Development and Clinical Validation of an X-Ray Interferometry System

Authors: Rachael Blair, Les Butler, Lillian Dickson, Kyungmin Ham, Charles Hartman, Kenneth (Kip) Matthews, Corinne Vanya

Affiliation: Louisiana State University, University of Minnesota, Refined Imaging LLC, Center for Advanced Microstructures and Devices

Abstract Preview: Purpose:
To develop and evaluate an x-ray interferometry system (XIS) for low-dose, high-sensitivity diagnostic imaging of lung diseases such as chronic obstructive pulmonary disease (COPD), asthma...

Comparison of Optimized Magnetic Resonance Sequences in the Treatment Planning of Surface Brachytherapy

Authors: Ivan M. Buzurovic, Phillip M. Devlin, Evangelia Kaza, Michael John Lavelle

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent work in surface brachytherapy (SBT) has demonstrated the feasibility of using magnetic resonance (MR)-guidance in place of Computer Tomography (CT) in SBT planning. The purpose of this...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Contrast-Dependent Loss of Edge Sharpness in Low-Contrast Targets with Increasing Iterative Reconstruction Strength

Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...

Deep-Learning Convolutional Neural Network-Based Breast Cancer Localization for Mammographic Images: A Study on Simulated and Clinical Images

Authors: Xiaoyu Duan, Xiang Li, Wenbo Wan, Lei Zhang, Yiwen Zhang

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: Breast screening has been proved to reduce breast cancer mortality by early detection and treatment for patients. Mammography is the most common and widely used technique for breast cancer sc...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Design and Construction of a Geometrical and Head Phantom with Internal Carotid Inserts for Flow Simulation in Image-Derived Input Function with 3T and 7T MR-Brainpet Insert Studies.

Authors: Dirk Grunwald, Hans Herzog, Hidehiro Iida, N. Jon Shah, Usman Khalid, Manfred Lennartz, Philipp Lohmann, Ceren Memis, Tobias Meurer, Claudia Regio Brambilla, Jürgen Scheins, Lutz Tellmann, Christoph W. Lerche, Martin Wiesmann, Karl Ziemons

Affiliation: FH Aachen University of Applied Sciences, Department of Chemistry and Biotechnology, Clinic for Diagnostic and Interventional Neuroradiology, Uniklinik Aachen,, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH,, Central Institute for Engineering, Electronics and Analytics (ZEA-1), Forschungszentrum, Turku PET Center, Institute of Biomedicine, Faculty of Medicine, University of Turku,

Abstract Preview: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development and Validation of an MR-Compatible Anthropomorphic Motion Phantom for Liver Motion Assessment and MR-Linac Gating System Optimization

Authors: Tsuicheng D. Chiu, Weiguo Lu, Aaron Thomlinson, You Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose: To develop and validate an MR-compatible anthropomorphic motion phantom to assess liver motion, real-time dosimetry, and gating system performance under controlled and reproducible respirator...

Developments of a Low-Cost Multi-Target Winston-Lutz Phantom and Software for SRS Linac Machines

Authors: Nellie Brovold, Wenbo Gu, Huan Amanda Liu, Lin Ma

Affiliation: University of Pennsylvania, Mayo Clinic

Abstract Preview: Purpose: To develop a low-cost comprehensive QA phantom and software for single-iso multi-target SRS Linac machines. This phantom can perform 1) Winston-Lutz QA test for on-axis and off-axis targets, ...

Does the Method Matter? How in Hominum, In Vivo, in silico, and in Phantasma Measures Compare and Contrast Is Assessing the Utility of Photon Counting CT?

Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Dual Energy Cone Beam Computed Tomography for Artifact Reduction and Enhanced Image Quality Using Existing Hardware in Radiation Therapy

Authors: Michael J. Choi, Vindu Wathsala Kathriarachchi, Christopher L. Nelson, Andrew P. Soderstrom, Yawei Zhang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, UF Health Proton Therapy Institute

Abstract Preview: Purpose: Cone Beam Computed Tomography (CBCT) is widely used in image-guided radiation therapy for patient positioning. While kV photons offer high image contrast, they are prone to artifacts caused b...

Dynamic 2.5D Surface Dosimetry Using Deformable Scintillator Array Imaging

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang

Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri

Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...

Establishing Comprehensive QA for Single-Isocenter Multiple Targets Stereotactic Radiosurgery

Authors: Angel Gomez, Titania Juang, Grace Gwe-Ya Kim, Boyu Meng

Affiliation: UC San Diego, UCSD, University of California San Diego

Abstract Preview: Purpose: Single-Isocenter Multiple Targets (SIMT) Stereotactic Radiosurgery (SRS) is widely used for its precision and effectiveness. However, standardized quality assurance (QA) protocols for SIMT SR...

Evaluating Phantom Usability for Thermal Imaging Localization in Radiation Therapy

Authors: Nema Bassiri, Kristen A. Duke, Neil A. Kirby, Thomas Wilson Klender, Christien Kluwe, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz, Michelle de Oliveira

Affiliation: Miami Cancer Institute, University of Texas HSC San Antonio, UT Health San Antonio

Abstract Preview: Purpose: Determine the practical usability for three phantoms to be used with the ExacTrac Dynamic thermal imaging system. Thermal-guided imaging can be used for inter and intra motion management, pat...

Evaluating the Impact of Reconstruction Algorithm on Wide-Angle Digital Breast Tomosynthesis System Optimization for Microcalcification Detection

Authors: Xiaoyu Duan, Xinyu Hu, Runqiu Li, Xiang Li

Affiliation: Dukekunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Accurate detection of small-sized microcalcifications (μCalcs) (< 500 µm) is critical for early breast cancer diagnosis, requiring optimal imaging systems and reconstruction algorithms. Ho...

Evaluation of Lead Glasses Efficiency in Reducing Eye Radiation Exposure during Angiography Using Optically Stimulated Luminescence Dosimeters

Authors: Yu-Ying Lin, Yu Chen Shen

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: This study evaluates the protective efficiency of lead glasses against radiation exposure to the eyes during angiography using optically stimulated luminescence dosimeters (OSLDs).
Methods...

Evaluation of Plan Quality and Optimal Isocenter Arrangement for Total Marrow and Lymphoid Irradiation on a Ring-Gantry Linac with Dual-Layer Mlc Using the Knowledge-Based Planning Technique

Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa

Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...

Extremity Imaging with Cone-Beam CT (CBCT) Scanner Dedicated for Hip Imaging – What Are the Effective Doses?

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...

Feasibility of 3D Printing for Fabricating Anthropomorphic Kidney Phantoms

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira

Affiliation: University of São Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...

Glandular Dose Map in Voxelized Phantoms across Advanced Breast Imaging Modalities Obtained from Monte Carlo Simulations

Authors: Rodrigo T Massera, Sofia Giaccone Thomaz, Alessandra Tomal, Giovanna Tramontin

Affiliation: Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Department of Imaging & Pathology, unit of Medical Physics & Quality Assessment, KU Leuven

Abstract Preview: Purpose: Monte Carlo simulations are increasingly used in breast dosimetry for their precision in estimating difficult-to-measure quantities, such as glandular dose. With ionizing radiation in breast ...

Impact of Tracking By Jaws or Mlc on Treatment Accuracy in Synchrony Modality for Tomohelical Technique

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...

Impact on image quality from reduced dose conebeam CT for pediatric fluoroscopy-guided interventional (FGI) imaging

Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier

Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-µm tungsten wire was imaged at ...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Material Modulated 3D Printed Human-Tissue Simulant Phantoms for Radiation Therapy Modeling and Safety

Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar

Affiliation: University of Minnesota

Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

Phantom-Based Dosimetric Comparison of Multiple CT Metal Artifact Reduction Algorithms for Head-and-Neck Radiotherapy

Authors: Loren Bell, Charles S Cathcart, Brett William Eckroate, Harold Y Hu, Joshua Kilian-Meneghin, Ke Nie, Fredrick Warburton, Zhenyu Xiong, Keying (Karen) Xu, Ning J. Yue, Yin Zhang, Lili Zhou

Affiliation: RWJBarnabas Health, Basis Scottsdale, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: This study compares the dosimetric impact of multiple metal artifact reduction (MAR) algorithms from different CT simulator vendors using an anthropomorphic head phantom for head-and-neck (H/...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Single Plane Positioning Tracking Proton and Helium Pencil Beam Radiographs: Phantom Study

Authors: Anahita Bakhtiari Moghaddam, Don F. DeJongh, Ethan DeJongh, Jennifer Hardt, Oliver Jäkel, Lukas Martin, Alexander Pryanichnikov, Joao Seco, Christina Stengl, Niklas Wahl

Affiliation: Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), ProtonVDA LLC, Department of Physics and Astronomy, Heidelberg University, Division of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT)

Abstract Preview: Purpose:
To evaluate the feasibility and performance of single-plane position tracking for proton and helium pencil beam radiography using a prototype imaging system, with the goal of providing a c...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Three-Dimensional Reconstruction of Triggered Images with Dehazing Algorithm for Precise Intrafraction Motion Detection in Spine SBRT

Authors: Hyosung Cho, Dae Yup Han, Duhee Jeon, Jiwon Park, Hyesun Yang

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose: To precisely detect intrafraction patient motion during spine stereotactic body radiotherapy (SBRT) treatment delivery, we propose an optimized technique for three-dimensional reconstruction ...

Towards Penile Small Vessel Imaging with Ferumoxytol-Enhanced MRI

Authors: Darren Fang, Amar Kishan, Justin McWilliams, Dan Ruan, Xiaodong Zhong

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiology, University of California, Los Angeles, Department of Radiological Sciences, University of California, Los Angeles

Abstract Preview: Purpose: Prostate radiotherapy can malform penile vasculature, contributing to erectile dysfunction and compromising quality of life. To detect, quantify, and preferably avoid such occurrences, this p...

Transforming CT Technologist Training: Real-Time Feedback, Gamification, and Phantom-Based Education for Accurate Patient Positioning

Authors: Rebecca Lamoureux, Zahra (Zara) Razi, Zachary Whipps

Affiliation: University of New Mexico Hospital

Abstract Preview: Purpose: Patient mispositioning in CT imaging contributes to inconsistent radiation dose delivery and suboptimal image quality, impacting patient safety and diagnostic outcomes. This study evaluates a...

Validating a Pre-Existing CT HU-to-Mass Density Curve for Direct Dose Calculation on High Quality Cbcts

Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray

Affiliation: University of California San Diego

Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...

Validation of Synthetic CT-Based Online Monitoring for Adaptive Proton Therapy

Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant

Affiliation: St. Jude Children's Research Hospital

Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...

X-Ray Motion Tomography: Creating 3D Lung Motion from Sparse 2D X-Ray Projections

Authors: Hilary Louisa Byrne, Owen Thomas Dillon, Paul J. Keall, Hunor Kertesz, Ricky O'Brien, Tess Reynolds

Affiliation: University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Medical Radiations, School of Health and Biomedical Sciences, RMIT University

Abstract Preview: Purpose: Imaging of lung motion and function has typically required multiple volumetric CT images to create deformation vector fields (DVF) for motion and ventilation images (function). However, CT sc...