Search Submissions ๐Ÿ”Ž

Results for "asc settings": 22 found

3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A Hybrid 4ฯ€-Proton Arc Robust Optimization

Authors: Wenhua Cao, Xianjin Dai, PhD, Hadis Moazami Goudarzi, Gino Lim, Miaolan Xie, Lei Xing, Lewei Zhao

Affiliation: University of Chicago Booth School of Business, Department of Radiation Oncology, Stanford University, Department of Industrial Engineering, University of Houston, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Proton Arc Therapy (PAT) delivers a continuous dose of radiation during gantry rotation. 4ฯ€ is a non-coplanar technique used for advanced proton therapy delivery. This work proposes a hybrid ...

A Modular Approach to Reversible and Stackable Medical Imaging Translation Models: CBCT-Based Synthetic MRI with Multiple U-Nets in Series (MUNETs)

Authors: Eric Chang, Nguyen Phuong Dang, Andrew Lim, Lauren Lukas, Lijun Ma, Yutaka Natsuaki, Zhengzheng Xu, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: Harnessed the power of AI and Deep Learning (DL), Generalized Neural Network models for medical image transformation are trained to predict target images from reference images, often requirin...

A New Way to Assess Dynamic Response of Centrally Located Lung Cancer (CLLC) to SBRT and Conventional Radiation Therapy (CRT)

Authors: Nina Burbure, Tawfik Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital, Dept. of Radiation Oncology, Fox Chase Cancer Center at Temple University Hospital

Abstract Preview: Purpose: Higher rates of local failures and toxicities challenged radiation therapy of centrally located lung cancer (CLLC). We assessed the treatment response by measuring the early changes of PET+ n...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

A Novel Groupwise Shape Deformable Registration Algorithm to Quantify the Respiratory Motion of the Heart in Respiratory 4DCTs While Accounting for Random Cardiac Motion Artifacts in the Respiratory 4DCTs

Authors: Anna E. Rodrigues, Yuhao Wang, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose: Accurate motion margin definition in StereoTactic Arrhythmia Radiotherapy (STAR) requires accurate cardiorespiratory motion assessment. However, respiratory 4DCT (r4DCT) images are affected b...

Artificial Intelligence (AI)-Driven Automatic Contour Quality Assurance (QA) with Uncertainty Quantification

Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Accurate delineation of treatment targets and organs-at-risk is crucial for radiotherapy. Despite significant progress in artificial intelligence (AI)-based automatic segmentation tools, effi...

BEST IN PHYSICS THERAPY: Overcoming Challenges in Developing Machine Learning-Driven Acute Kidney Injury Predictive Models Using Non-Standard Emrs in Resource-Limited Settings

Authors: Yuanhan Chen, Ziqiang Chen, Qi Cheng, Feng Ding, Rui Fang, Shengwen Guo, Li Hao, Qiang He, Haiquan Huang, Yu Kuang, Xinling Liang, Yuanjiang Liao, Guohui Liu, Chen Lu, Qingquan Luo, Jing Sun, Yanhua Wu, Zhen Xie, Qin Zhang, Lang Zhou

Affiliation: South China University of Technology, Dongguan people's hospital, Sichuan Provincial People's Hospital, Peopleโ€™s Hospital of Xinjiang Uygur Autonomous Region, Second Hospital of Anhui Medical University, Guangdong Provincial Peopleโ€™s Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangdong Easy Life Information Technology Co., Ltd, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, The First Affiliated Hospital of Zhejiang Chinese Medical University (Zhejiang Provincial Hospital of Traditional Chinese Medicine), Medical Physics Program, University of Nevada, Second Hospital of Jilin University, Chongqing Ninth People's Hospital

Abstract Preview: Purpose: Acute kidney injury (AKI) is a global healthcare issue with a rapid onset and severe consequences. Repeated measurement of serum creatinine (SCr) levels, a clinical standard of care, is cruci...

Box-Prompt Zero-Shot Smart Segmentation in Radiation Oncology Using a SAM-Based Model: Smartsam

Authors: Kristen A. Duke, Samer Jabor, Neil A. Kirby, Parker New, Niko Papanikolaou, Arkajyoti Roy, Yuqing Xia

Affiliation: St. Mary's University, The University of Texas San Antonio, UT Health San Antonio

Abstract Preview: Purpose:
The Segment Anything Model (SAM) is a foundational box-prompt-based model for natural image segmentation. However, its applicability to zero-shot 3D medical image segmentation, particularl...

Checking of Sensitivity of Volumetric Modulated Arc Therapy Quality Assurance System with a Cavity Generation Method

Authors: Kaile Li, Esmail Parsai

Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...

Commission and Clinical Implementation of the 1st Step-and-Shoot Proton Arc Therapy for Head and Neck Cancer Patient Treatment

Authors: Xiaoda Cong, Rohan Deraniyagala, Xuanfeng Ding, Xiaoqiang Li, Jian Liang, Peilin Liu, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose:
Commission a step-and-shoot arc therapy(SPArc-step&shoot) for treating head-neck cancer patients as a desired interim milestone toward full dynamic treatment.
Methods:
An in-house de...

Development and Clinical Validation of a Tissue Maximum Ratio (TMR)-Based Monitor Units Second Check Script for Dynamic Conformal-Based Hyperarc Brain Radiosurgery Plans Via Scatter Correction Factors

Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...

Development of an Orthogonal X-Ray Projections-Guided Cascading Volumetric Reconstruction and Tumor-Tracking Model for Adaptive Radiotherapy

Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu

Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Graph-Based Feature Selection to Improve Stability and Reproducibility of CT-Based Radiomics in Head and Neck Squamous Cell Carcinoma: A Cross-Institutional Study

Authors: Daria Gaykalova, Ranee Mehra, Jason K Molitoris, Hajar Moradmand, Lei Ren, Amit Sawant, Phuoc Tran

Affiliation: University of Maryland School of Medicine, Maryland University Baltimore, University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: Radiomics extracts quantitative imaging biomarkers from medical images. However, maintaining the reproducibility and stability of selected features across institutions and parameter settings ...

Integrating Radiomics and ADC Ratio for Multicenter Prostate Cancer Diagnosis: A Harmonized Machine Learning Approach

Authors: George Agrotis, Marios Myronakis, Dimitrios Samaras, Kyriaki Theodorou, Ioannis Tsougos, Vassilios Tzortzis, Maria Vakalopoulou, Alexandros Vamvakas, Aikaterini Vassiou, Marianna Vlychou

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Department of Radiology, University of Thessaly, Netherland Cancer Institute, Department of Urology, University of Thessaly, CentraleSupelec, University Paris-Saclay

Abstract Preview: Purpose: Prostate cancer (PCa) diagnosis remains challenging due to discrepancies in Gleason Scoring (GS) and risks of overdiagnosis and underdiagnosis. Multiparametric MRI (mpMRI), including Apparent...

Investigating Factors Impacting the Consistency of Signal-to-Noise Ratio in Mammographic Automatic Exposure Control

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the impact of tissue-equivalent attenuator materials, the region of interest (ROI) size, and the orientation of the attenuator positioning on the measured signal-to-no...

Noise Sensitivity of Benchmark Whole-Body CT Segmentation Models: Totalsegmentator and Vista3D Performance on an Independent Dataset

Authors: Samuel L. Brady, Shruti Hegde, Alexander Knapp, Usman Mahmood, Joseph G. Meier, Elanchezhian Somasundaram, Zachary Taylor

Affiliation: Cincinnati Children's Hospital Medical Ctr, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Cincinnati Children's Hospital Medical Center, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To assess how two benchmark multi-organ CT segmentation models respond to varying image noise levels.
Methods:
This study utilized the pediatric CT dataset from The Cancer Imaging Ar...

One Year Experience of Biology-Guided Radiotherapy (BgRT) on PET-Linac in an Academic Center

Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...

Quality Monitoring of Temporal Performance Degradation in Clinical Use of AI Auto-Segmentation

Authors: Ali Ammar, Quan Chen, Jingwei Duan, Yi Rong, Nathan Y. Yu, Libing Zhu

Affiliation: Mayo Clinic Arizona, University of Alabama at Birmingham

Abstract Preview: Purpose: Clinical performance of deep learning-based auto-segmentation (DLAS) can degrade over time due to AI โ€œagingโ€ from unseen data input compared to the initial model training data. This study aim...

Quantitative Assessment of Iodine Detectability As a Function of Tissue Density, Thickness and Dose in Contrast-Enhanced Mammography

Authors: Jeffrey S. Nelson, Raj Kumar Panta, Megan K. Russ, Ehsan Samei

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Contrast-enhanced mammography (CEM) enhances tumor detection by utilizing energy-dependent information from iodinated contrast agents. However, there is a lack of quantitative techniques to a...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...