Search Submissions 🔎

Results for "attenuation values": 18 found

A Realistic Computer Simulation Study Assessing How Beam Hardening Affects the Accuracy of CT Lung Attenuation Values

Authors: Zijia Guo, Michael F. McNitt-Gray, Frederic Noo, Karl Stierstorfer

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurately assessing lung parenchyma health is critically important in the management of patients with chronic obstructive pulmonary disease. CT attenuation values are valuable for this purpo...

Analyzer-Less X-Ray Interferometry with Super-Resolution Methods

Authors: Joyoni Dey, Hunter Cole Meyer, Murtuza Taqi

Affiliation: Louisiana State University

Abstract Preview: Purpose: We propose using super-resolution methods for X-ray grating interferometry without an analyzer with detectors that fail to meet the Nyquist sampling rate needed for traditional image recovery...

Assessment of the Impact of CT Respiratory Motion on PET SUV Quantification through Virtual Imaging

Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei

Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington

Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...

CT-Free PET Imaging: Synthetic CT Generation for Efficient and Accurate PET-Based Planning

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
PET is used in radiotherapy workflows for accurate target delineation. However, a separate CT scan is typically required for attenuation correction in PET imaging and for registering PET-d...

Clinical Application of Biology-Guided Radiotherapy (BgRT) to Patient Having a Cardiac Implantable Electronic Device (CIED)

Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical

Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...

Determining the Optimal CT Tube Voltage for Imaging Bone Structures in Radiotherapy.

Authors: Mohamed Bahaaeldin Mohamed Afifi, Nahla Nagy Ahmad Ataalla, Ahmed A. Eldib

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Optimizing CT imaging parameters is crucial for balancing radiation dose, contrast resolution, and accurate Hounsfield unit representation, particularly in radiotherapy treatment planning. Th...

Development of Patient-Specific Lead Ball Compensator for Total Body Irradiation

Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park

Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...

Dosimeteric Parameter Evaluation of Digital Polycrystalline Semiconductor Dosimeters for Quality Assurance of High-Dose-Rate Brachytherapy

Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee

Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital

Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Feasibility of 3D Printing for Fabricating Anthropomorphic Kidney Phantoms

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira

Affiliation: University of São Paulo (USP), Institute of Physics

Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...

GPU-Accelerated Beamlet and Full Dose Calculations for Efficient Radiation Therapy Planning

Authors: Girish Bal, Jan Kralj, Ayan Mitra, PhD, Ling Shao, Matjaz Subic, Yevgen Voronenko

Affiliation: RefleXion Medical, Cosylab

Abstract Preview: Purpose: This work enhances the efficiency of radiation therapy treatment planning by optimizing the beamlet dose matrix and full patient dose computations using GPU acceleration. The Collapsed-Cone C...

Material Modulated 3D Printed Human-Tissue Simulant Phantoms for Radiation Therapy Modeling and Safety

Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar

Affiliation: University of Minnesota

Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Toward Harmonized AI-Based Quantitative CT: A Voxel-Printed, Patient Specific Phantom for Cross-Platform Harmonization

Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...

Towards Achieving Quantitative Attenuation Values in CT with Energy-Integrated and Photon-Counting Detectors

Authors: Zijia Guo, Viktor Haase, Michael F. McNitt-Gray, Frederic Noo

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: The attenuation values in CT hold strong potential for disease diagnosis. However, they lack reliability, which has limited their use to clinical trials where variability can be controlled. S...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR Equilibrium®) is r...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...