3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A Retrospective Analysis of Automatic Exposure Control (AEC) Tracking Failure Rates in Radiographic Systems

Authors: Benjamin W. Maloney, Ashley E. Rubinstein, Colin Schaeffer, Justin Yu

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Radiography AEC systems ensure correctly exposed images for varied kVp and patient thicknesses. The specific kVp and PMMA thicknesses selected for testing AEC tracking may affect passing rate...

Development of Hybrid Shielding Collimator to Reduce Radiation Exposure in Fluoroscopy

Authors: Yona Choi, Kyo-tai Kim, Seungwoo Park, Dung Thi Tran

Affiliation: Gemss Health Care Inc,, Korea Institute of Radiological & Medical Sciences

Abstract Preview: Purpose: We developed shielding materials and a hybrid concept collimator for fluoroscopy to reduce the dose to normal tissues outside the treatment field, which are capable of quantifying dose rate a...

Fully Automatic Pipelines for Anatomical ROI Detection and Exposure Index Calculation in X-Ray Imaging : Foundation Model-Based Frameworks for Dose Standardization

Authors: Yoonha Eo

Affiliation: Yonsei University

Abstract Preview: Purpose: To develop a fully automatic and unsupervised algorithm for estimating the Exposure Index (EI) of various Regions of Interest in X-ray imaging using advanced foundation models. Traditional EI...

Investigating Factors Impacting the Consistency of Signal-to-Noise Ratio in Mammographic Automatic Exposure Control

Authors: James Ward, Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the impact of tissue-equivalent attenuator materials, the region of interest (ROI) size, and the orientation of the attenuator positioning on the measured signal-to-no...

Multi-Institutional Evaluation of Radiographic Automatic Exposure Control Performance Testing: Methodology, Outcomes, and Failure Rates

Authors: Caroline Cheney, Nicole M. Lafata, Zaiyang Long, Dustin W. Lynch, Erin B. Macdonald, Andy Madore, Douglas E. Pfeiffer, Colin Schaeffer, Alexander W. Scott

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, UVA Health, Duke University Health System, Mayo Clinic, Henry Ford Health, Boulder Community Health, Varian, Cedars-Sinai Medical Center

Abstract Preview: Purpose: This work evaluates the significance of performing established radiography automatic exposure control (AEC) tests by comparing testing methodology, outcomes, and failure rates across multiple...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...