Search Submissions 🔎

Results for "average maximum": 95 found

A Dosimetric Analysis of Lu-177-Based Radiopharmaceutical Therapy for Optimizing Therapeutic Ratio

Authors: Travis James McCaw, Ravi Patel, Abdelhamid Saoudi, Joseph Shields

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, University of Pittsburgh Medical Center, UPMC

Abstract Preview: Purpose: The current treatment approach for Lu-177-based radiopharmaceutical therapy involves multiple administrations, each delivering a constant activity of 200 mCi. This study evaluates whether the...

A Motion Analysis of Cardiac Substructures for Guiding Stereotactic Arrhythmia Radiotherapy Motion Management

Authors: Hongyu An, Phillip Cuculich, H Michael Gach, Yao Hao, Trevor McKeown, Clifford Robinson, Yuhao Wang, Deshan Yang

Affiliation: Washington University School of Medicine in St. Louis, Washington University School of Medicine, Duke University, Department of Radiation Oncology, Duke University, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis

Abstract Preview: Purpose: This study investigated cardiac motion characteristics of ventricular tachycardia patients to support patient-specific motion management for stereotactic arrhythmia radiotherapy (STAR) treatm...

A Patient-Specific Approach to Surface Guided-DIBH SBRT Candidacy Using Surface Deformation Maps

Authors: Savannah Decker, Grace Gwe-Ya Kim, Laura Padilla

Affiliation: UC San Diego, University of California San Diego

Abstract Preview: Purpose: The success of surface-guided deep-inspiration breath-hold (SG-DIBH) treatments depends on accurate identification of suitable candidates. Sub-optimal patient selection can result in prolonge...

A Robust Quantitative Metric for Optimal Beam Selection in Radiotherapy of the Peripheral Lung Lesions: A Crucial Step in Standardization of Lung SBRT

Authors: Leslie Bell, Kai Ding, Reza Farjam, Russell K Hales, Sarah Han-Oh, Hamed Hooshangnejad, Jina Lee, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Optimal beam arrangement is crucial in automation and standardization of thorax radiotherapy where substantial tissue heterogeneity and several critical organs at risks (OARs) exist. Here, we...

An Agglomerative Clustering-Based Program for Optimizing Multiple-Target SRS Treatment Planning

Authors: Josephine Chen, CheukKai Becket Hui, Yildirim D. Mutaf

Affiliation: Kaiser Permanente

Abstract Preview: Purpose:
To demonstrate the effectiveness of a target clustering program in generating cluster configurations and isocenter placements for multiple brain lesions in SRS treatment planning, with the...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

Automated Quantitative Method for Source Position Calculation in Annual Quality Assurance of High Dose Rate Brachytherapy Gynecological Applicators

Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...

Automated Treatment Planning for Stereotactic Recurrent Head and Neck Cancers Using Knowledge-Based Planning, Multicriteria Optimization, and Dosimetric Scorecards

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...

BEST IN PHYSICS ULTRASOUND: A Calibration Framework for Quantifying Element Misalignment in 2D Matrix Array Transducers Used in 3D Quantitative Ultrasound

Authors: Cristel Baiu, Laura Castaneda Martinez, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Department of Medical Physics, University of Wisconsin-Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: 2D matrix array transducers (2DMAT) are advancing volumetric ultrasound due to their ability to provide more isotropic 3D resolution, fast volumetric imaging, and highly customizable focusing...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Best- and Worst-Case Scenario: Uncertainty Bounds Informed By Daily Scanning in Weekly CBCT-Based Accumulated Dose for Head and Neck Cancer

Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson

Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...

Big Data in-Vivo Epid Image Prediction for VMAT Radiotherapy

Authors: Casey E. Bojechko, Lance C Moore

Affiliation: University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: EPID images collected during treatment can serve as an in-vivo error detection mechanism. Previous works have shown that comparing in-vivo EPID images to AI-predicted EPID images for IMRT pla...

CNN-Based Reconstruction for 3D Scintillation Dosimetry of Proton Pencil Beams

Authors: Sam Beddar, Jason Michael Holmes, Daniel G. Robertson, James J. Sohn, Ethan D. Stolen

Affiliation: Department of Radiation Oncology, Mayo Clinic, MD Anderson Cancer Center, Department of Radiation & Cellular Oncology, University of Chicago, Department of Radiation and Cellular Oncology, University of Chicago

Abstract Preview: Purpose: Camera-based scintillation dosimetry incorporating large volumes have shown promise for fast and comprehensive evaluation of external beam treatment fields. While some efforts have been made ...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Clinical Outcomes of Gamma Knife Stereotactic Radiosurgery Treatments for Intracranial Arteriovenous Malformations & Fistulas: A Single Institutional Retrospective Study

Authors: Madeleine Arbogast, David Dorndos, Denise E Foltz, Justin Fraser, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Department of Neurosurgery, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: For stereotactic radiosurgery (SRS) treatments of intracranial arteriovenous malformations (AVM) and fistulas (AVF), same-day Leksell Gamma Knife (GK) is the preferred modality. Long-term cli...

Clinical Validation of a Deep-Learning Segmentation Tool for Head and Neck Cancer Patients and Thoracic and Abdominal Cancer Patients

Authors: Haijian Chen, Katja M. Langen, William Andrew LePain, Claire Tran, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University, Georgia Institute of Technology

Abstract Preview: Purpose: To validate the performance of a commercial deep-learning segmentation (DLS) tool for head and neck cancer (HNC) and thoracic and abdominal cancer (TAC) by comparing it to manual segmentation...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Comparative Analysis of Four Measurement Methods for Multileaf Collimator Backlash

Authors: Niko Ahjoniemi, Antti Kulmala, Katja Peltola

Affiliation: Clinical Research Institute HUS, Helsinki University Hospital

Abstract Preview: Purpose: To determine the backlash of a multileaf collimator (MLC) using four measurement methods: motor encoder (primary readout), linear potentiometer (secondary readout), amorphous silicon panel (p...

Comparison Study of Shift Frequency and Magnitude By Prostate Fiducial Tracking System: Triggered Image and Calypso

Authors: David J. Carlson, Yiu-Hsin Chang, Zhe (Jay) Chen, Hyosung Cho, Dae Yup Han, MinYoung Lee, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine, Yonsei University

Abstract Preview: Purpose:
To compare the intra-fractional motion tracking sensitivity of prostate fiducial markers using triggered imaging and calypso tracking for prostate cancer cases.
Methods:
This study w...

Comparison of Linear Energy Transfer Volume Histograms from Two Beam Geometries in a Pediatric Chordoma Patient Treated with Intensity Modulated Proton Therapy

Authors: Michael Confer, Mark A. Newpower

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: A pediatric patient recently presented to our clinic for treatment for chordoma, which was near the brainstem. The clinician elected to treat this patient using intensity modulated proton the...

Comparison of Respiratory Motion between 4D-MR and 4D-CT in Compression Belt Patients

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...

Confidence in a Tattoo-Less Transition

Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak

Affiliation: Christiana Care

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...

Consecutive Daily Fractions with Itv Boost Are Safe for Treating Central Non-Small Cell Lung Cancer Using Stereotactic Body Radiation.

Authors: Baher Elgohari, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Jeonghoon Park, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, UPMC, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To compare toxicity between consecutive-daily (QD) with every-other-day (QoD) delivery of lung stereotactic-body-radiation (SBRT) for central non-small-cell lung cancer (NSCLC).
Methods...

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Correcting for Lung Ventilation in Model-Based CT

Authors: Ryan Andosca, Igor Barjaktarevic, Peter Boyle, Jie Deng, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Jack Neylon, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Pulmonology, University of California Los Angeles, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, UCLA, UCLA Radiation Oncology

Abstract Preview: Purpose: To develop a Hounsfield Unit ventilation-based correction method for use with model-based CT when used as a replacement for 4DCT.
Methods: The model-based CT we employ is termed 5DCT, whic...

Deep Learning-Based Ventricular Auto-Segmentation for Dosimetric Analysis in Intraventricular Tumor SRS

Authors: John Byun, Juan J Cardona, Steven D Chang, Cynthia Fu-Yu Chuang, Xuejun Gu, Yusuke Hori, Hao Jiang, Fred Lam, Lianli Liu, Weiguo Lu, David Park, Erqi Pollom, Elham Rahimy, Deyaaldeen Abu Reesh, Scott Soltys, Gregory Szalkowski, Lei Wang

Affiliation: Department of Radiation Oncology, Stanford University, Department of Neurosurgery, Stanford School of Medicine, Department of Neurosurgery, Stanford University, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
Intraventricular tumors pose significant challenges in neurosurgery due to their complex location. Therefore, brain SRS could be a better treatment option. At our institution, some patient...

Deep Learning–Based Dose Prediction for Automated Proton Radiation Therapy Planning of Breast Cancer

Authors: Ahssan Balawi, Peter Jermain, Timothy Kearney, Sonali Rudra, Michael H. Shang, Markus Wells, Mohammad Zarenia

Affiliation: Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose: To investigate the applicability and accuracy of a deep learning (DL) model in predicting radiation dose distribution for breast cancer patients treated with pencil-beam-scanning proton radio...

Design of Filtimator (Filter + Collimator) for CBCT of Pediatric Cancer Patients Receiving Proton Therapy

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...

Development and Clinical Validation of Hyperarc Stereotactic Radiosurgery Method for Intraocular Tumors

Authors: Chase Cochran, Damodar Pokhrel, William St Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Currently, intraocular disease is primarily treated via COMS-plaques brachytherapy. Various stereotactic approaches via photons/proton beam have also been implemented (CyberKnife/GammaKnife/p...

Development and Clinical Validation of a Tissue Maximum Ratio (TMR)-Based Monitor Units Second Check Script for Dynamic Conformal-Based Hyperarc Brain Radiosurgery Plans Via Scatter Correction Factors

Authors: Jacob Gooslin, Ellis Lee Johnson, Damodar Pokhrel

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: HyperArc radiosurgery permits treatment of multiple brain lesions using a single-isocenter improving treatment planning efficiency and workflow. A key stereotactic planning aspect is an indep...

Development of a Beam Profile Variation Observation Model for Intensity Modulated Radiotherapy

Authors: Kaile Li

Affiliation: Alexander T. Augusta Miliary Medical Center

Abstract Preview: Purpose: To develop a experimental method in observation of beam profile transfer model in intensity modulated radiotherapy (IMRT).
Methods: A picket fence plan was generated in Eclipse treatment p...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Dosimetric Assessment of Spatially Fractionated Radiation Therapy on Prostate Cancer Cases: Our Experience in Nsia-Luth Cancer Center, Lagos

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo

Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre

Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...

Dosimetric Comparative Analysis of Modulated and Non Modulated Electron Bolus in Nasal Electron Therapy

Authors: Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Michael Leyva, Alejandro Rene Llanes Lopez, William Romaguera, Ranjini P. Tolakanahalli, Deborah Wang

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health

Abstract Preview: Purpose: To evaluate whether a modulated electron bolus (MEB) technique improves both nominal and shifted dose distributions in nasal electron therapy as compared to a non‑modulated, uniform‑thickness...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dosimetric Impact on Patient Roll/Yaw Change for Whole Breast 3D Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...

EBT4 Film Dosimetry and the Significance of the ¼ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Effects of Plan Optimization Techniques on Relative Biological Effective Dose in a Thin Intracranial Target Volume

Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch

Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center

Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...

Efficient FAST-Forward Planning Strategy for X-Ray Based Online Adaptive Radiotherapy

Authors: Prasanna Alluri, Mona Arbab, Xingzhe Li, Chang-Shiun Lin, Mu-han Lin, David D.M. Parsons, Asal Rahimi, Justin D. Visak, Narine Wandrey

Affiliation: UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Intelligence-Optimization-Engine (IOE) v1.0 relied heavily on planner expertise and patient-specific IMRT beam arrangements, requiring frequent revisions. While VMAT workflows offered potenti...

Enhanced Prediction of Iroc Stereotactic Radiosurgery Phantom Audit Results with Treatment Parameters, Complexity Metrics, DVH, and Dosiomics Using Machine Learning

Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...

Enhancing Robustness in Proton Therapy through Online Adaptive Workflow: An in-Silico Study

Authors: Robbie Beckert, Weiren Liu, Thomas R. Mazur, Allen Mo, Stephanie Perkins, Hailei Zhang, Tianyu Zhao

Affiliation: Washington University in St. Louis School of Medicine, University of South Florida, WashU Medicine

Abstract Preview: Purpose: Online adaptation may mitigate uncertainties in proton therapy arising from interfractional anatomical changes. While robust optimization accounts for setup and range uncertainties during pla...

Evaluating Stent-Induced Dose Perturbations in Intravascular Brachytherapy with EBT4 Films

Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...

Evaluating Variability in Luminance Measurements Among Calibrated Light Meters for Mammography Review Workstation Surveys

Authors: Weiyuan Wang

Affiliation: University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
This study investigates the variability between popular light meters by measuring mammography review workstation monitors using three calibrated light meters.
Methods:
Three calibrat...

Evaluating the Efficacy and Efficiency of Spine Treatment Using Diagnostic CT

Authors: Sunil Mani, Ilakiya Raghavendiran, Vasanthan Sakthivel, Skanda Kabilan Swamy

Affiliation: Edmond Santa Fe High School, Edmnd Deer Creek High, Cancer Specialists of North Florida, Advanced Medical Physics

Abstract Preview: Purpose: Purpose/Objective(s): To evaluate and validate the dose calculation and delivery accuracy for patients planned using diagnostic CT
Methods: A total of forty-two patients with palliative sp...

Evaluating the Impact of an Average Versus Machine-Specific Dosimetric Leaf Gap on Dose Calculation

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

Evaluation of Fractional Variability in High-Risk Clinical Target Volume (HR-CTV) during High-Dose-Rate Brachytherapy for Cervical Cancer: A Retrospective Analysis for Adaptive Treatment Planning.

Authors: Olubunmi Odunola Aregbe, Clara Ferreira, Margaret Reynolds, David A. Sterling, Jianling Yuan

Affiliation: University of Minnesota, University of Minnesota Physicians, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: To analyze volume changes in the high-risk clinical target volume (HR-CTV) during high-dose rate (HDR) brachytherapy for cervical cancer patients. The study aims to evaluate the trend and cor...

Evaluation of MRI Distortion across a Multi-Site Health System and the Importance of MRI Distortion QA in Stereotactic Radiosurgery (SRS)

Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng

Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program

Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Evaluation of Synaptive MRI Geometric Distortion with Sun Nuclear MR Distortion and Image Fusion Head Phantom

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Jing Feng, Wenzheng Feng, Joseph Hanley, Jeff Stainsby, Tingyu Wang

Affiliation: Synaptive Medical, Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose:
The Synaptive MRI is a 0.5T superconducting head only system (first US install 2023). This is the first study that evaluates the geometric accuracy using a Sun Nuclear MR Distortion and Im...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexion™ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXion® X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Evaluation on the Newest Automatic Isocenter Placement Function in ZAP-X Advanced TPS

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: In August 2024, ZAP-X introduced automatic placement for isocenters in a DP-1010 upgrade for treatment planning. In this study, plans made by automatic placed isocenters are compared to those...

Feasibility of X-Ray Based Online Adaptive Dynamic Optimization with Integrated Knowledge-Based Planning for Head and Neck Cancer

Authors: Jacob S. Buatti, Mu-Han Lin, Dominic Moon, David D.M. Parsons, David Sher, Justin D. Visak, Hui Ju Wang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Most current adaptive treatment planning systems (TPS) natively utilize static planning goals from the reference plan for online adaptive re-optimization. In complex head-and-neck cancer (HNC...

Feasibility of Zap-X Beam Quality Assurance Using Cherenkov Radiation

Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao

Affiliation: University of Miami

Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...

Fetal Radiation Exposure Monitoring of Pregnant Employees across Multiple Departments and Areas in a Hospital

Authors: Janet Ching-Mei Feng, Janet Gutierrez, Aylin Ozus, Patricia Svolos

Affiliation: Bellaire High, McGovern Medical School, University of Texas Health Science Center at Houston, Environmental Health & Safety, University of Texas Health Science Center at Houston, UTHealth McGovern Medical School

Abstract Preview: Purpose: Exposure to radiation may become harmful to the fetus depending on the gestational age and absorbed dose. The Nuclear Regulatory Commission states the radiation exposure to the embryo/fetus o...

Foundation Model Guidance for CBCT-CT Image Registration in Radiotherapy

Authors: Hacene Azizi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Mohamed Lamine Seghier

Affiliation: Khalifa University Biomedical Engineering & Biotechnology, Laboratory of dosing, analysis and characterization in high resolution, Ferhat Abbas Setif 1 University, Khalifa University Physics Department, Khalifa University

Abstract Preview: Purpose:
To ensure accurate alignment of cone-beam computed tomography (CBCT) and computed tomography (CT) images for image-guided radiotherapy, this study evaluates a foundation model guidance fra...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Glandular Dose Map in Voxelized Phantoms across Advanced Breast Imaging Modalities Obtained from Monte Carlo Simulations

Authors: Rodrigo T Massera, Sofia Giaccone Thomaz, Alessandra Tomal, Giovanna Tramontin

Affiliation: Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Department of Imaging & Pathology, unit of Medical Physics & Quality Assessment, KU Leuven

Abstract Preview: Purpose: Monte Carlo simulations are increasingly used in breast dosimetry for their precision in estimating difficult-to-measure quantities, such as glandular dose. With ionizing radiation in breast ...

Head and Neck Treatment Evaluation with Cone Beam Computed Tomotherapy

Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...

Improved Setup Accuracy for Dibh Whole Breast Radiotherapy with Surface-Guided Radiation Therapy

Authors: CheukKai Becket Hui, Goldie M. Klein, Yildirim D. Mutaf, Amir Pourmoghaddas

Affiliation: UC Health, Kaiser Permanente

Abstract Preview: Purpose:
In this study, we investigated the effect of SGRT (Align-RT) implementation on patient setup accuracy for DIBH breast radiotherapy treatments.
Methods:
We extracted vertical post-ima...

Improving 4D-MRI Parameters for Abdominal Tumor Motion Management: A Phantom Study

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...

Initial Phantom Studies Towards Implementation of Sequential Dual Energy CBCT on an Adaptive Radiotherapy Linac Platform

Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam

Affiliation: University of Michigan

Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...

Introduce a Novel Spot-Scanning Proton Arc(SPArc) Optimization Algorithm for Single Energy Extraction(SEE) Synchrotron-Accelerator-Based Proton Therapy System (PTS)

Authors: Xiaoda Cong, Xuanfeng Ding, Gang Liu, Peilin Liu, Jiajian Shen

Affiliation: Department of Radiation Oncology, Mayo Clinic, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Corewellhealth William Beaumont University Hospital

Abstract Preview: Purpose: This study aims to develop the first SPArc optimization algorithm based on the Dynamic Programming (SPArc-DP), to improve the treatment delivery efficiency for synchrotron-accelerator-based P...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Investigation of the Correlation between Proton Linear Energy Transfer and Treatment Field Hinge Angles in Brain Tumor Patients Treated with Intensity Modulated Proton Therapy

Authors: Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Minesh P. Mehta, Andrew J. Wroe, Jen Yu

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: Linear energy transfer (LET) is directly related to relative-biological-effectiveness dose in proton therapy. This study aims to investigate how the treatment field hinge angles affect LET of...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Machine Learning Knowledge Based Planning Model for Hypo Fractionated Prostate/Prostate Lymph Nodes Treatments

Authors: Nina Burbure, Tawfik G. Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital

Abstract Preview: Purpose: To evaluate the performance of KBP models for hypo-fractionated prostate and pelvic lymph nodes (LN) VMAT plans.
Methods: A KBP model (TUH KBP) was developed in Eclipse treatment planning ...

Material Decomposition with Propagation-Based X-Ray Phase Contrast: A Comparison of Multi-Energy and Multi-Distance Imaging

Authors: Giavanna Luisa Jadick, Patrick J La Riviere

Affiliation: University of Chicago

Abstract Preview: Purpose: We assess two multi-measurement acquisition schemes for material decomposition with x-ray phase-contrast imaging (XPCI); demonstrating for the first time that multi-distance imaging can match...

Non-Planar Narrow-Beam CT: Near Scatter-Free, High-Resolution Breast Imaging at Screening Mammography Doses.

Authors: Peymon Ghazi

Affiliation: MALCOVA Inc.

Abstract Preview: Purpose: To develop a near scatter‐free breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...

Parameterized 4D Deformable Registration (p4Dreg) in Abdominal 4DCT Scans

Authors: Edward Robert Criscuolo, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose:
Deformable registration of 4DCT images has many clinical applications, but current methods are unreliable and can produce dangerous errors. Iterative, parametrized image registration does ...

Patient-Specific Bio-Morphological Features in Cherenkov Imaging for Positioning Verification: A Retrospective Analysis in Accelerated Partial Breast Irradiation (aPBI) VMAT Radiotherapy

Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang

Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...

Patient-Specific Imaging Modality Agnostic Virtual Digital Twins Modeling Temporally Varying Digestive Motion

Authors: James M. Balter, Lando S. Bosma, Jorge Tapias Gomez, Nishant Nadkarni, Mert R Sanbuncu, William Paul Segars, Ergys D. Subashi, Neelam Tyagi, Harini Veeraraghavan

Affiliation: University of Michigan, The University of Texas MD Anderson Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Cornell University, University Medical Center Utrecht, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Develop patient-specific virtual digital twin (VDT) cohorts modeling physically realistic spatio-temporal gastrointestinal (GI) organs (stomach and duodenum) digestive motion.
Methods: Pat...

Post-Implant Dosimetry (PID) between 1D and 2D Cs-131 Seed Models for Post-Op Cavities in Recurrent GBM Patients

Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health

Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Prostate SBRT Motion Study and PTV Margin Evaluation with Exactrac Fiducial Tracking

Authors: Ahmad K. Al-Basheer, Andrew Clarke Grice, Kelly E. Hosier, Mark Logsdon, Evan A. Silverstein, Chris Tunnicliff, Chuan Wu

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: For Prostate SBRT Boost treatments, determine whether a uniform 2mm CTV to PTV margin is sufficient to give 95% dose coverage to the CTV in 90% of patients via a modified Van Herk Margin Form...

Qualitative Assessment of Low-Dose 4D Cone-Beam CT Protocols for Daily Lung SBRT Patient Alignment

Authors: Yussuf A. Abdelal, Junguo Bian, Michael Delafuente, Sebastien A. Gros, Hyejoo Kang, Luke Layman, M Mahesh, John C. Roeske

Affiliation: Department of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Johns Hopkins Univ

Abstract Preview: Purpose: This study evaluates the feasibility of optimizing 4DCBCT imaging protocols for gated lung SBRT, by reducing dose while maintaining the image quality required for accurate patient alignment.<...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Quantifying Respiratory Motion Effects in Lung Cancer Radiotherapy Using 4DCT Voxel Analysis

Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda

Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...

Reinforcement Learning Based Machine Parameter Optimization for Two-Arc Prostate VMAT Planning

Authors: William T. Hrinivich, Junghoon Lee, Lina Mekki

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins University, Johns Hopkins University

Abstract Preview: Purpose: Volumetric modulated arc therapy (VMAT) planning is a computationally expensive process. In this work, we propose a reinforcement learning (RL) framework to automatically optimize dose rate a...

Research on the Target Current Pulse Counting Method for Measuring the Output Dose of Medical Standing Wave Electronic Linear Accelerator

Authors: Shixiong Huang, Daming Li

Affiliation: The Affiliated Nanhua Hospital, University of South China, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital

Abstract Preview: Purpose: To assess the feasibility of using target current pulse signals to evaluate the output dose of medical standing wave electronic linear accelerators.
Methods: The Target I signal of the acc...

Robust Evaluation of the Pronumbra Immobilization System for Proton Therapy HN Treatment

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: The CQ Medical kVue Pronumbra Head & Neck (HN) System is a new immobilization device for proton therapy. The mask includes 4 large knobs that attach to the board with built-in shims. These kn...

Robust and Radiobiologically Accurate Dose Summation Strategy for Multiple Courses of Stereotactic Re-Irradiation of Metastatic Brain Cancer Patients with Previous WBRT

Authors: Garrett Russell Hamilton, Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Recurrent brain metastasis is very common, and patients who previously received whole-brain radiotherapy (WBRT) may receive an additional course(s) of stereotactic radiosurgery (SRS) to selec...

SRS Treatment Planning for Brain Metastases on Varian Truebeam and Elekta Gamma Knife Icon

Authors: Carl D. Elliston, Lawrence Koutcher, Michael J. Price, Adam C. Riegel, Michael B Sisti, Tony J.C. Wang, Andy (Yuanguang) Xu

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: An inverse treatment planning software was recently introduced to Gamma Knife radiosurgery. The purpose of this study is to compare the plan quality of the Gamma Knife ”Lightning” with that o...

Sources of Variability in Evaluating Ultrasound Imaging Performance Using Randomly-Distributed Hypoechoic Sphere Phantom

Authors: Cristel Baiu, Zheng Feng Lu, Dufan Wu, Baihui Yu

Affiliation: University of Wisconsin, Massachusetts General Hospital, University of Chicago

Abstract Preview: Purpose: IEC TS 62791:2022 specified a clinically meaningful and quantitative framework for evaluating diagnostic ultrasound performance by measuring the lesion signal-to-noise ratio (LSNR) using rand...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Tumor Dose Escalation for Recurrent Head and Neck SRT Via a Hyperarc-Based Rapidplan Model

Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Demonstrating the feasibility of dose escalation for stereotactic recurrent head and neck (RHN) cancers through the deployment of a Hyper-Arc Based RapidPlan (HARP) model through an Eclipse S...

Using Machine Learning to Predict Esophagitis Risk in Lung Cancer Radiotherapy Based on Clinical and Dosimetric Factors

Authors: Ibtisam Almajnooni, Siyong Kim, Nathaniel Miller, Elisabeth Weiss, Lulin Yuan

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: Radiation-induced esophagitis (RE) is a common concern in lung cancer IMRT. Recent studies have indicated that the risk of radiation side effects varies greatly with patients’ baseline clinic...

Using Radiotherapy Dose Accumulation Routine (RADAR) for Deformable Offline Adaptive Head and Neck Dose Accumulation

Authors: Shira Abraham, Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Phillip G. Lichtenwalner, Chuan Zeng, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
We have developed a tool that uses deformable image registrations to perform deformable dose accumulation. In this work we evaluate use of this tool for adaptive head and neck dose accumul...

Water-Equivalent Thickness Mapping (WET-MAP) – a Potential Alternative to 4D Robust Optimization for Motion Management in Proton Treatment Planning

Authors: Duncan Henry Bohannon, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
4D robust optimization, incorporating additional images (e.g., maximum inhale/exhale phases), is commonly used to account for target motion in proton treatment planning. However, the incre...