Search Submissions 🔎

Results for "back projection": 25 found

A Novel 2D Scintillation Dosimeter Using Long Scintillating Fibers.

Authors: Louis Archambault, Luc Beaulieu, Alexis Horik, Sajjad Ahmad Khan

Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de physique, de génie physique et d'optique, Université Laval

Abstract Preview: Purpose: This study presents a novel 2D scintillation dosimeter leveraging long scintillating fibers for quality assurance (QA) in radiotherapy. The primary goal is to optimize critical parameters suc...

A Quantitative Analysis of Hypersight CBCT Image Quality Using a Phantom-Based Approach Under Different Scatter Conditions

Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...

A Realistic Computer Simulation Study Assessing How Beam Hardening Affects the Accuracy of CT Lung Attenuation Values

Authors: Zijia Guo, Michael F. McNitt-Gray, Frederic Noo, Karl Stierstorfer

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurately assessing lung parenchyma health is critically important in the management of patients with chronic obstructive pulmonary disease. CT attenuation values are valuable for this purpo...

Assessment of Radiation Protection Knowledge Among Operation Professional Nurses

Authors: Yu-Ying Lin

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: This study aimed to evaluate the level of radiation protection knowledge among operating room professional nurses.

Methods: A questionnaire was distributed to operating room profession...

Automatic 4D Lung PET-CT Segmentation Using Hybrid Deep Neural Network

Authors: Hongyi Jiang, Fang-Fang Yin

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...

BEST IN PHYSICS THERAPY: Impact of Local Tissue Oxygenation Level on the Flash Effect in Murine Skin

Authors: David J. Gladstone, P. Jack Hoopes, David I Hunter, Brian W Pogue, Jacob Pierce Sunnerberg, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Geisel School of Medicine, Dartmouth College

Abstract Preview: Purpose: The FLASH effect, characterized by normal tissue sparing under ultra-high dose rate (UHDR) radiation delivery, remains mechanistically unclear. This study investigated the relationship betwee...

Clinically Ready Simulation Package for Monitoring Gamma Hotspot Emission, and Detection in Patient Anatomy

Authors: Ananta Raj Chalise, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: Prompt gamma (PG) imaging is a promising modality for proton dose verification. Currently, there is a lack of effective tool to investigate the PG emission during proton therapy and optimize ...

Deep Learning Based Filter with Back-Projection Operator for CT Reconstruction

Authors: Justus Adamson, Mu Chen, Ke Lu, Zhenyu Yang, Fang-Fang Yin, Rihui Zhang, Yaogong Zhang, Haipeng Zhao, Haiming Zhu, Yuchun Zhu

Affiliation: Shanghai Dacheng Medical Technology, Duke University, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: In filtered back-projection (FBP) reconstruction, conventional filters often reduce noise at the expense of high-frequency details, leading to structural details loss. To address this limitat...

Deep Learning-Based Prompt Gamma Imaging for Proton Range Verification Using Patient Data Simulation

Authors: Mostafa Cham, Matthias K Gobbert, Zhuoran Jiang, Sina Mossahebi, Ruth Obe, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma

Affiliation: University of Maryland School of Medicine, UMBC, University of Maryland Baltimore County, University of Maryland, Baltimore County, Stanford University, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc, Department of Infomation Systems, UMBC

Abstract Preview: Purpose: Compton camera (CC)-based prompt gamma imaging (PGI) offers real-time proton range verification. However, its limited-angle measurements cause severe distortions in PGI, affecting its clinica...

Determine Noise Weighting Factor in Photon-Counting CT Via Deep Learning for Personalized Noise Reduction

Authors: Xinhui Duan, Roderick W. McColl, Mi-Ae Park, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: UT Southwestern Medical Center, Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Image-based deep-learning noise-reduction techniques have been developed for photon-counting CT (PCCT) to improve image quality with reduced radiation dose. The denoising strength is typic...

Development of a Computational Immunohistochemical Stained Tissue Analysis of Intracellular Flash Induced Radiochemical Oxygen Depletion

Authors: Najah Curtis, Michele M. Kim, Cameron Koch, Ioannis I Verginadis, Rodney D. Wiersma, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: FLASH has been shown to have increased normal tissue sparing compared to standard dose rate radiation and, separately, has been shown to rapidly consume oxygen intercellularly in vivo through...

Development of a Proton CT System Based on 2D Scintillation Detection

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...

Development of an Orthogonal X-Ray Projections-Guided Cascading Volumetric Reconstruction and Tumor-Tracking Model for Adaptive Radiotherapy

Authors: Penghao Gao, Zejun Jiang, Huazhong Shu, Linlin Wang, Gongsen Zhang, Jian Zhu

Affiliation: Laboratory of Image Science and Technology, Key Laboratory of Computer Network and Information Integration, Southeast University, Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Artificial Intelligence Laboratory, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: We propose a cascading framework for time-varying anatomical volumetric reconstruction and tumor-tracking, guided by onboard orthogonal-view X-ray projections.
Methods: We employe multiple...

Dynamic X-Ray Acoustic Computed Tomography (XACT)

Authors: Leshan Sun, Liangzhong Xiang, Yifei Xu, Yuchen Yan

Affiliation: University of California, Irvine

Abstract Preview: Purpose: X-ray Acoustic Computed Tomography (XACT) is a transformative innovation in medical imaging, overcoming the limitations of conventional X-ray techniques. It introduces new possibilities in cl...

Emulating Human Perception of Low-Dose CT Image Quality Via Deep Generative Models

Authors: Jongduk Baek, Jooho Lee, Adam S. Wang

Affiliation: Stanford University, Yonsei University

Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...

Evaluating the Impact of Reconstruction Algorithm on Wide-Angle Digital Breast Tomosynthesis System Optimization for Microcalcification Detection

Authors: Xiaoyu Duan, Xinyu Hu, Runqiu Li, Xiang Li

Affiliation: Dukekunshan University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Accurate detection of small-sized microcalcifications (μCalcs) (< 500 µm) is critical for early breast cancer diagnosis, requiring optimal imaging systems and reconstruction algorithms. Ho...

Evaluation of AI-Generated Synthetic 4DCT from 3DCT for Radiotherapy Planning

Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin

Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center

Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...

Four-Dimensional on-Beam Computed Tomography Reconstruction from Projection Image Differences Representing Motion Change

Authors: Kwang-Ho Cheong, Seungryong Cho, Joonil Hwang, Jae Won Jung, Hoyeon Lee, Raymond Hyunwoo Moon, Inhwan Yeo, Jihyung Yoon

Affiliation: East Carolina University, INOVA Schar Cancer Institute, University of Hong Kong, Hanllym University, KAIST, University of Rochester

Abstract Preview: Purpose: Monitoring a target and neighboring organs during beam delivery is crucial for successful radiotherapy (RT). Conventional transit imaging methods lack volumetric reconstruction capabilities, ...

Investigating Microcalcification Detectability in a Static Breast Cone Beam CT Via Monte Carlo Simulation

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Gantry motion and patient breathing during a breast cone beam CT (bCBCT) scan is one of the major challenges for microcalcification (μCalcs) detection. By deploying a large number of individu...

Investigation of Prompt Gamma Imaging Using a Three Axis Rotating Compton Camera

Authors: Molokotima Kekana, Dennis S. Mackin, Stephen W. Peterson, Jerimy C. Polf

Affiliation: Department of Physics, University of Cape Town, M3D, Inc, The University of Texas MD Anderson Cancer Center, Houston

Abstract Preview: Purpose: To study the imaging characteristics of a prototype prompt gamma (PG) imaging system consisting of multiple rotating Compton cameras (CC).

Methods: The prototype CC imaging system is c...

Investigation of a Novel Snout-Mounted Compton Camera System for Monitoring Dose Depth

Authors: Ananta Raj Chalise, Matthias K Gobbert, Hajar Moradmand, Sina Mossahebi, Stephen W. Peterson, Jerimy C. Polf, Lei Ren, Ehsan Shakeri, Vijay Raj Sharma, Jie Zhang

Affiliation: University of Maryland School of Medicine, University of Maryland Baltimore County, University of Maryland, University of Maryland, Baltimore County, University of Maryland, School of Medine, Department of Physics, University of Cape Town, M3D, Inc

Abstract Preview: Purpose: We are developing a novel Compton Camera (CC) system mounted orthogonally on the treatment nozzle for prompt gamma (PG) imaging-based proton range verification during treatment. This study in...

Mesh-Based Multiregion Model of Adult Human Kidneys for Dosimetric Evaluation of Radiopharmaceutical Therapy

Authors: John P. Aris, Wesley E. Bolch, Chansoo Choi, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Abdul-Vehab Dozic, Amy M. Geyer, Harald Paganetti, Shreya P. Pathak, Julia D. Withrow

Affiliation: St. Luke's Health System, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: The goal of this study was to enhance the accuracy of renal dosimetry in radiopharmaceutical therapy (RPT) by developing a more detailed and precise kidney model. In RPT, accurate dose estima...

Quantitative 3D Surface Mapping of Cherenkov Images for Real-Time Beam Deviation Detection in Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone

Affiliation: Thayer School of Engineering, Dartmouth College

Abstract Preview: Purpose: Cherenkov images are two-dimensional projections of the surface light emissions, and lack spatial information about the radiotherapy beam delivery. We implement the first fusion of Cherenkov ...

Quantitative Fluorescence Molecular Tomography Guide Radiation Therapy

Authors: Jiahao Chen, Yunwen Huang, Yidong Yang, Shanshan Zhang, Ning Zhao, Cheng Zheng

Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop a molecular image-guided radiotherapy technique for accurate and effective radiation treatment using quantitative fluorescence molecular tomography (FMT).
Methods: X-ray cone be...

Real-Time 3D Visualization of Electric Field with Electroacoustic Tomography

Authors: Jadon O Buller, Yankun Lang, Liangzhong Xiang, Andrea Paulina Yanez

Affiliation: University of Maryland School of Medicine, University of California, Irvine

Abstract Preview: Purpose: With the widespread adoption of electroporation, there is growing interest in deep-tissue electric field monitoring. Electroporation therapy ablates target regions by generating electric fiel...