Authors: Brett Lewis, Roland Teboh
Affiliation: HUMC, Hackensack University Medical Center
Abstract Preview: Purpose: The novel RefleXion SCINTIX BgRT system relies on the FDG uptake distribution from a PET study to plan and deliver dose. One of the patient eligibility criteria is that any uptake outside the...
Authors: Shahed Badiyan, Bin Cai, Tu Dan, Michael Dohopolski, Steve B. Jiang, Deepkumar Mistry, Arnold Pompos, Robert Timmerman, Jing Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Biology-guided radiotherapy (BGRT) offers significant potential for personalized and adaptive cancer treatment, with clinically available systems such as SCINTIX from Reflexion now being intr...
Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh
Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center
Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...
Authors: Resat Aydin, Brett Lewis, Jayesh Mistry, Roland Teboh
Affiliation: HUMC, Hackensack University Medical Center
Abstract Preview: Purpose:
We developed a Python-based solution to systematically quantify and detect fluorodeoxyglucose (FDG) uptake beyond a predefined Biologically Tracking Zone (BTZ) in PET images. This method i...
Authors: Evan Calabrese, Hangjie Ji, Kyle J. Lafata, Casey Y. Lee, Eugene Vaios, Chunhao Wang, Lana Wang, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke Kunshan University, North Carolina State University
Abstract Preview: Purpose: To develop a biologically guided deep learning (DL) model for predicting brain metastasis(BM) local control outcomes following stereotactic radiosurgery (SRS). By integrating pre-SRS MR image...
Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical
Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...
Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong
Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...
Authors: David J. Carlson, Huixiao Chen, Tianqi Chen, Jun Hou, Chi Liu, Qiong Liu, Henry S. Park, Huidong Xie
Affiliation: Yale University, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The RefleXionยฎ X1 Biology-guided radiotherapy (BgRT) system consists of dual PET detectors, a 6MV linear accelerator (linac), a 64-leaf collimator, an MVD detector, and a CT scanner mounte...
Authors: Jessica Fagerstrom, Juliana Ama Kplorfia, Abigail N.M. Quaye, Mercy T Schandorf, Bishwambhar Sengupta, Peniel T Twum, Afua A. Yorke
Affiliation: University of Ghana Medical Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Medical Equipment and Ancillary Services, Girls Excellence Movement, Global Communities
Abstract Preview: Purpose: To empower and promote diversity in Science, Technology, Engineering, and Mathematics (STEM), an educational presentation and hands-on session were organized to raise awareness of STEM career...
Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu
Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To determine minimum target size and FDG contrast thresholds for reliable Biology-guided Radiation Therapy (BgRT) delivery using a systematic phantom study.
Methods: A custom 3D-printed ph...
Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue
Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...
Authors: Emily Hansen, Jay Mistry, Alois M. Ndlovu, Niara Rowe, Roland Teboh
Affiliation: Hackensack University Medical Center
Abstract Preview: Purpose: SCINTIX Biology-guided radiotherapy (BgRT) on the RefleXion X1 relies on a new planning system and advanced planning techniques. The first patient SCINTIX BgRT plans are compared to similar c...
Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu
Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...
Authors: Girish Bal, Thomas I. Banks, Bin Cai, Neil Desai, Aurelie Garant, Orhan Oz, Elizeva Phillips, Rameshwar Prasad, Chenyang Shen, Robert Timmerman
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical
Abstract Preview: Purpose: This study reports findings from the first-in-human imaging-only trial evaluating the feasibility of using the novel PET tracer 68Ga-PSMA-11 (Illuccix) to guide external beam radiotherapy on ...
Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park
Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...
Authors: Angela J Da Silva, Andrew Groll, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung
Affiliation: Reflexion Medical Inc,, RefleXion Medical
Abstract Preview: Purpose: PET-based biology-guided radiotherapy (BgRT) is a radiation therapy technique that uses PET imaging to deliver tracked dose to the tumor in real-time. We characterized the delivery accuracy o...
Authors: Emily Hansen, Alois M. Ndlovu, Niara Rowe, Roland Teboh
Affiliation: Hackensack University Medical Center
Abstract Preview: Purpose: The accuracy of SCINTIX biology-guided radiotherapy (BgRT) on the RefleXion X1 is dependent on the correct alignment of the isocenter between all subsystems, including setup lasers, kV imagin...
Authors: Shahed Badiyan, Girish Bal, Thomas I. Banks, Bin Cai, Tu Dan, Aurelie Garant, Andrew R. Godley, Steve Jiang, Orhan Oz, Arnold Pompos, Rameshwar Prasad, Chenyang Shen, David Sher, Robert Timmerman, Kenneth Westover
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical
Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) is a novel FDA-cleared technology for treating lung and bone tumors based on 18F-FDG PET uptake. This study summarizes the first-year experience treating 29...
Authors: Jon Burns, Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung
Affiliation: Reflexion Medical Inc,, RefleXion Medical
Abstract Preview: Purpose: Biology-guided radiotherapy uses positron emissions from FDG-avid tumor volumes to provide a of the planned prescribed dose with high accuracy. The purpose of this work is to characterize BgR...
Authors: Rico Castillo, Katherine Gonzalez, Casey C. Heirman, Kyle J. Lafata, Xiang Li, Yvonne M Mowery, Yvonne M Mowery, Allison Pittman, Ashlyn G. Rickard, Breylon Riley
Affiliation: Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh
Abstract Preview: Purpose: To evaluate the relationships between quantitative imaging biomarkers and chemoradiation resistance in head and neck squamous cell carcinoma (HNSCC) using preclinical mouse models.
Met...
Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma
Affiliation: RefleXion Medical
Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...
Authors: Grant Gibbard, Chunhui Han, An Liu
Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...