Search Submissions 🔎

Results for "breast vmat": 18 found

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Automatic Breast VMAT Planning Using Script and Rapidplan on Eclipse

Authors: Maria Jose Almada, Bruno Forti, Patricia Murina, Carlos Daniel Venencia

Affiliation: Instituto Zunino - Fundacion Marie Curie, Dra.

Abstract Preview: Purpose: The use of VMAT for the breast requires duplication of the patient's CT, several planning structures, and patient-specific dose-volume constraints depending on the patient's anatomy, fraction...

Contingency Planning for Left-Sided Breast Radiation Treatment Using Breath-Hold Technique with Different Delivery Methods

Authors: Nrusingh C. Biswal, Sally Cheston, Sung-Woo Lee, Weiguang Yao, Baoshe Zhang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: The deep inspiration breath-hold (DIBH) technique in left breast radiation reduces doses to critical organs such as the heart, left lung, and left anterior descending artery (LAD). With the a...

Dosimetric Comparison of Lattice and 3D Grid VMAT Planning for Spatially Fractionated Radiotherapy

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...

Dosimetric Effect of Patient Positioning Errors in Dual-Isocenter VMAT for Bilateral Breast Cancer Treatment: A Quantitative Assessment

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the dosimetric effects of patient positioning errors, including setup inaccuracies and yaw deviations, on dual-isocenter volumetric modulated arc therapy (VMAT) plans for...

Efficient FAST-Forward Planning Strategy for X-Ray Based Online Adaptive Radiotherapy

Authors: Prasanna Alluri, Mona Arbab, Xingzhe Li, Chang-Shiun Lin, Mu-han Lin, David D.M. Parsons, Asal Rahimi, Justin D. Visak, Narine Wandrey

Affiliation: UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: Intelligence-Optimization-Engine (IOE) v1.0 relied heavily on planner expertise and patient-specific IMRT beam arrangements, requiring frequent revisions. While VMAT workflows offered potenti...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Arc Number Variation on VMAT Lattice Radiotherapy Plans

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to evaluate the effects of varying the number of arcs on treatment plans created using Volumetric Modulated Arc Therapy (VMAT) for Lattice radiotherapy (LRT).
Methods: Thre...

Impact of Mlc and Collimator Errors in Psqa Techniques for VMAT Breast Treatment Plans

Authors: Maria Jose Almada, Oscar Apaza, Carlos Bohorquez, Ezequiel Cabrera, Rogelio Diaz Moreno, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, FaMAF, UNC, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA employs gamma analysis to verify the planned versus delivered dose. Evaluating the effectiveness of PSQA techniques in identifying errors is crucial. This study aims to incorporate ML...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

Optimizing PTV Coverage in VMAT Breast Plans: A Robust Evaluation of Motion and Flash Margins

Authors: William N. Duggar, John C. White

Affiliation: UMMC, University of Mississippi Medical Center

Abstract Preview: Purpose:
To evaluate the impact of patient motion on PTV coverage for 95% and 90% target volumes in VMAT breast treatment plans and to determine the appropriate flash margins required to maintain r...

Patient-Specific Bio-Morphological Features in Cherenkov Imaging for Positioning Verification: A Retrospective Analysis in Accelerated Partial Breast Irradiation (aPBI) VMAT Radiotherapy

Authors: Yao Chen, Lesley A Jarvis, Allison Matous, Rongxiao Zhang

Affiliation: Dartmouth College, University of Missouri, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: Precise patient positioning is critical in accelerated partial breast irradiation (aPBI) to ensure accurate dose delivery to the tumor bed while minimizing exposure to surrounding healthy tis...

Quantification of Wet Towel As Bolus on Skin Dose for VMAT Partial Breast Irradiation

Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang

Affiliation: Cleveland Clinic

Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.

Methods: Two VMAT partial breast plans (3000 cGy in 5...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Volumetric-Modulated Arc Therapy (VMAT) Is Associated with Improved Dose Homogeneity, but More Normal Tissue Irradiation Compared to Three-Dimensional Conformal Radiation Therapy (3DCRT) for Breast Cancer

Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center

Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...