Search Submissions 🔎

Results for "breathing amplitudes": 9 found

4DCT Vs 5DCT: How to Generate an Accurate Target Volume

Authors: Ryan Andosca, Rojine T. Ariani, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: To demonstrate that 5DCT can provide an accurate internal tumor volume (ITV) while 4DCT cannot.
Methods: The 5DCT imaging protocol uses a motion model and 25 deformably registered free-bre...

Commissioning and Evaluation of Deviceless 4DCT

Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor

Affiliation: Oregon Health & Science University, Northwest Medical Physics Center

Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...

Correcting for Lung Ventilation in Model-Based CT

Authors: Ryan Andosca, Igor Barjaktarevic, Peter Boyle, Jie Deng, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Jack Neylon, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Pulmonology, University of California Los Angeles, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, UCLA, UCLA Radiation Oncology

Abstract Preview: Purpose: To develop a Hounsfield Unit ventilation-based correction method for use with model-based CT when used as a replacement for 4DCT.
Methods: The model-based CT we employ is termed 5DCT, whic...

Deep Dive of Clinical 5DCT Patient Results

Authors: Ryan Andosca, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, UCLA, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: To demonstrate the performance of the model-based CT scanning protocol, 5DCT, as an alternative to 4DCT.
Methods: 5DCT imaging results for 242 patients were analyzed. Implementation of the...

Free-Breathing Spirometer-Gated Proton Pencil Beam Scanning Delivery Maintains Tumor Coverage with Improved Organ-at-Risk Sparing: A Motion Phantom Validation

Authors: Uriel Aura, Qing Chen, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Meng Wei Ho, Sheng Huang, Minglei Kang, Stanislav Lazarev, Nancy Y Lee, Yang Lei, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Anna Zhai, Ajay Zheng

Affiliation: DYN'R Medical System, New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Tianjin Medical University Cancer Institute&Hospital, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Managing tumor motion during pencil beam scanning proton therapy remains challenging. This study investigated the feasibility and dosimetric benefits of Free-Breathing Respiratory-Gated Deliv...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Improving 4D-MRI Parameters for Abdominal Tumor Motion Management: A Phantom Study

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...

Is Simplicity Even Better: Deep Learning Algorithms for Breath Motion Phase Prediction in Motion Management

Authors: Amanda J. Deisher, Andrew YK Foong, Witold Matysiak, Jing Qian, Xueyan Tang, Erik J. Tryggestad, Mi Zhou

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Phase gating is commonly employed to mitigate the impact of tumor motion in radiotherapy. Due to the machine-specific time delay between triggering and radiation delivery, the triggering sign...

Margins to Account for Cardiac and Respiratory Motion in Cardiac Radioablation

Authors: Alanah M. Bergman, Marc W Deyell, Tania Karan, Jakob Marshall, Justin Poon, Devin Schellenberg, Steven Thomas, Richard Thompson

Affiliation: University of British Columbia, University of Alberta, BC Cancer

Abstract Preview: Purpose: A conservative approach to account for random errors due to intra-fraction cardiac and respiratory motion during cardiac radioablation (CR) is to define a margin equal to the amplitude of car...