4D CBCT Dynamic Images Recovery Using a 4D Neural Network

Authors: Ziheng Deng, Yao Hao, Runping Hou, Deshan Yang, Jun Zhao, Yufu Zhou

Affiliation: Department of Radiation Oncology, Duke University, School of Biomedical Engineering, Shanghai Jiao Tong University, Washington University School of Medicine, Department of Radiation Oncology, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: 4D CBCT has been developed to provide dynamic images for image-guided radiation therapy. However, as projection data are sorted into sparse and clustered phase-specific bins, 4D CBCT images a...

4DCT Vs 5DCT: How to Generate an Accurate Target Volume

Authors: Ryan Andosca, Rojine T. Ariani, Peter Boyle, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Dylan P. O'Connell, Ricky R Savjani

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology

Abstract Preview: Purpose: To demonstrate that 5DCT can provide an accurate internal tumor volume (ITV) while 4DCT cannot.
Methods: The 5DCT imaging protocol uses a motion model and 25 deformably registered free-bre...

A Diffusion-Based AI Framework for Continuous Deformable Image Registration and Time-Resolved Dynamic CT Generation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Gregory Szalkowski, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Respiratory motion management is crucial for accurate radiation delivery to moving targets while protecting healthy tissue, relying on time-resolved volumetric imaging and continuous deformab...

A Novel Metric for Predicting Heart Dose Assessment in Left-Sided Breast Cancer Radiotherapy

Authors: Yufeng Cao, Arun Gopal, Kai Huang, Kai Wang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center, University of Maryland, Baltimore

Abstract Preview: Purpose: The treatment of left-sided breast tumors poses significant concerns regarding the risk of radiation-induced damage to nearby organs, particularly the heart. In clinical practice, breath-hold...

A Virtual 4DCT Generator Based on a Digital Phantom with Joint Cardiac and Respiratory Motions

Authors: Phillip Cuculich, Geoffrey D. Hugo, Xiwen Li, Michael T. Prusator, Clifford Robinson, Pamela Samson, Xue Wu

Affiliation: Washington University School of Medicine in St Louis, Washington University School of Medicine in St. Louis, University of Utah, WashU Medicine

Abstract Preview: Purpose:
For development of novel motion management methods it is useful to have a digital phantom capable of realistic simulation of respiratory 4DCT acquisition of the thorax, including cycle-to-...

AI-Powered Real-Time x-Ray Guided Tracking to Improve Stereotactic Arrythmia Radioablation: Proof of Principle

Authors: Vicky Chin, Mark Gardner, Nicholas Hindley, Paul J. Keall, Adam Mylonas

Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose: Stereotactic Arrhythmia Radioablation (STAR) is a non-invasive method to treat cardiac arrhythmias by targeting aberrant electrical conduction regions in the heart. Targeting is challenging g...

An Image Registration-Based Motion Correction Procedure to Recover Joint Cardiac and Respiratory Motion from Respiratory 4DCT

Authors: Phillip Cuculich, Geoffrey D. Hugo, Xiwen Li, Michael T. Prusator, Clifford Robinson, Pamela Samson, Xue Wu

Affiliation: Washington University School of Medicine in St Louis, Washington University School of Medicine in St. Louis, University of Utah, WashU Medicine

Abstract Preview: Purpose: Stereotactic arrhythmia radiotherapy (STAR) requires compensation for both respiratory and cardiac motions of the heart. Respiratory 4DCT scans implicitly include cardiac motion and cycle-to-...

Auto-Beam Hold Validation for Varian Sgrt Identify 3.0 on Truebeam Linear Accelerators

Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...

Benefits on Respiratory Gating Delivery of Lung SBRT

Authors: Andrew Huang, Jonathan Huang, Andrew S Kennedy, Ellie Grace Kong, Ajay Zheng

Affiliation: New York Proton Center, Centennial Medical Center, Executive Medical Physics Associates, Sarah Cannon Cancer Institute, Belmont University

Abstract Preview: Purpose:
Lung stereotactic body radiotherapy (SBRT) is the standard of care for early-stage lung cancer. Respiratory phase gating can be applied to mitigate motion-induced effects. The purpose of t...

Can We Use Smaller Margin for the Planned Target Volume with Adaptive Radiotherapy?

Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center

Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...

Characterisation of Breathing Volumes and Surface Motion for Upright and Supine Treatment Positions

Authors: Sophie Boisbouvier, David Cobben, Anthony L Criscuolo, Michael W. Kissick, Mark Ramtohul, Gordon Sands, Tracy Underwood

Affiliation: University of Surrey, Department of Medical Physics, Queen Elizabeth Hospital, Lung Cancer and Sarcoma Radiotherapy, The Clatterbridge Cancer Centre, Leo Cancer Care, Radiotherapy department, Centre Léon Bérard

Abstract Preview: Purpose:
Pulmonary function tests (PFTs) help assess treatment options for lung cancer patients. Conventionally, these are undertaken upright, whereas radiotherapy is administered supine. This stud...

Comparison of Dose Metrics to Critical Heart Substructures for Different Planning Techniques, and Scan Techniques for Right Sided Breast Irradiation

Authors: Wesley A. Belcher, Aidan Burke, Matthew Green, Taylor Stamey

Affiliation: ECU Health, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: The purpose of this study was to determine the effect of using deep inhalation breath hold (DIBH) vs. free breathing (FB) and intensity-modulated radiation therapy (IMRT) vs. 3D for right-sid...

Determination of Optimal Surface Rois for Sgrt-Guided Dibh Treatment of Abdominal Cancer

Authors: Megan E. Daly, Ajay Fernandez, Ryan D. Hernandez, Soo Kyoung Kim, Arta Monjazeb, Minahal Naveed, Peter C. Park, Jotsna Singh, Payton H. Stone

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To identify optimal deep-inspiration breath-hold (DIBH) surface-guided radiotherapy (SGRT) regions of interest (ROIs) for abdominal stereotactic body radiation therapy (SBRT) treatments.
M...

EPR Oximetry for Hypoxia Assessment in Deep Tissues Using Oxytrack

Authors: Maciej M. Kmiec, Periannan Kuppusamy, Ryan C. O'Connell, Sergey V. Petryakov, Conner Ubert

Affiliation: Dartmouth College

Abstract Preview: Purpose: The rigid needle-like EPR sensor, OxyTrack, was developed to provide minimally invasive, reliable, and quantitative measurements of oxygen distribution (pO2) in deep tissues. EPR oximetry's c...

Enhanced Lung Function Assessment through Machine Learning Analysis of 4DCT Subregional Respiratory Dynamics

Authors: Jing Cai, Zhi Chen, Hong Ge, Yu-Hua Huang, Bing Li, Zihan Li, Ge Ren

Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University and Henan Cancer Hospital

Abstract Preview: Purpose: Algorithms based on subregional respiratory dynamics (SRD) capture spatiotemporal heterogeneity in the ventilation process, though rely on empirical modelings to map surrogate ventilation. Gi...

Evaluation of Daily Respiratory Pattern from a Single Free-Breathing Cone Beam CT Scan

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...

Evaluation of Target Localization Accuracy As a Function of CBCT Acquisition Speed

Authors: Kuan Ling Chen, Jiajin Fan, Maduka M. Kaluarachchi, Wei Nie

Affiliation: Inova Schar Cancer Institute

Abstract Preview: Purpose: This study evaluates the impact of CBCT acquisition speed on the accuracy of moving target alignment during image-guided radiotherapy. Additionally, the influence of target motion speed and r...

Free-Breathing VMAT and IMRT Versus Deep Inspiration Breath- Hold 3D-CRT Techniques for Left-Breast Cancer: A Practical Solution for Developing Countries

Authors: Md. Yousuf Ali, Parvin Akhter Banu, Ehteshamul Hoque, Qazi Mushtaq Hussain, Md Jobairul Islam, Md. Abdul Mannan, Sadia Afrin Sarah, Mostafa Aziz Sumon, Ahammad Al Mamun Sweet, AFM Kamal Uddin

Affiliation: Labaid Cancer Hospital & Superspeciality Centre

Abstract Preview: Purpose: Radiotherapy for left-sided breast cancer can induce cardiac injury. Deep Inspiration Breath Hold (DIBH) is a technique that minimizes cardiac exposure during treatment. This study compares d...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Optimizing Lung SBRT Delivery: Role of Multiple Cbcts in Managing Intra-Fraction Motion

Authors: Anthony J. Doemer, Ian Gallagher, Yimei Huang, Jeff A. Riess, Kundan S Thind, Bo Zhao

Affiliation: Henry Ford Health

Abstract Preview: Purpose: Stereotactic body radiation therapy (SBRT) is commonly used for early-stage lung cancer. While pre-treatment CT captures some tumor motion, it may not fully represent intra-fraction motion du...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

The Role of 3D Vane MRI in Accurate Phase Matching with 4D-CT for Motion Representation in Liver Cancer Radiotherapy

Authors: Jiayun Chen, Shengqi Chen, Junchao Li, Fei Liu, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, Tongji Medical College, Huazhong University of Science & Technology, School of Electronic Engineering, Beijing University of Posts and Telecommunications, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To assess if 3D Vane MRI can accurately depict the motion of the target volume and OARs.
Methods: This retrospective study included 54 liver cancer patients who underwent both 3D Vane MRI ...

Ultrafast Proton Delivery with Pin Ridge Filters (pRFs): A Novel Approach for Motion Management in Proton Therapy

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Active breath-hold techniques effectively mitigate respiratory motion but poses challenges for patients who are unable to tolerate the procedure. Conventional planning relies on multiple ener...

Using the Liver Dome for Real-Time Respiratory Motion Adaptive Tracking in Cyberknife Stereotactic Body Radiotherapy (SBRT) for Lung Tumors

Authors: Hulya Ozdemir Buss, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The CyberKnife (CK) Synchrony system provides sub-millimeter motion-tracking accuracy during stereotactic body radiotherapy (SBRT). For lung tumors near the diaphragm, we evaluated the feasib...