Search Submissions 🔎

Results for "calculation directly": 15 found

A Framework for the Standardization of Radiomics Classes in the Presence of Blur and Noise

Authors: Huay Din, Grace Jianan Gang, Grace Hyun Kim, Michael F. McNitt-Gray, Joseph W. Stayman, Yijie Yuan

Affiliation: Johns Hopkins University, John Hopkins University, University of Pennsylvania, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose:
Radiomics rely on quantitative features to discern underlying biological signatures. However, feature dependence on the imaging systems themselves hampers the creation of reproducible and ...

An Integrated Robust Inverse Planning Based on AI-Built Dose Kernel Library for Preclinical Radio-Neuromodulation Using Focused Kv X-Rays

Authors: Wenbo Gu, Chenhui Qiu, Ke Sheng, Liyan Sun, Weiyuan Sun, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiology, Stanford University, University of Pennsylvania, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, Stanford University,

Abstract Preview: Purpose:
The small animal radio-neuromodulation platform developed in our previous work utilized focused kV x-ray beams rotating and translating in predefined trajectories to irradiate small, mm si...

Assessing Dose Enhancement and Shadowing Effects in Head and Neck Cases with Titanium Mandibular Implants

Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC

Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...

Assessing Long-Term Stability of Parylene-Coated, 3D-Printed Plastic Vessels for Water Calorimetry-Based Radiation Dosimetry

Authors: Philip Cutter, Mark D'Souza, Arman Sarfehnia

Affiliation: Toronto Metropolitan University, Sunnybrook Health Sciences Centre, Sunnybrook Health Science Center

Abstract Preview: Purpose: Water calorimetry (WC) serves as an important standard for measuring absorbed dose to water, an essential metric in radiation therapy. WC directly and absolutely quantifies energy deposition ...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Comparison of CBCT Dose Calculation Accuracy between Truebeam Hypersight Image Reconstruction Algorithms

Authors: Sarah Aubert, Harald Keller, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Support for treatment planning directly on CBCT imaging on C-arm linacs will enable adaptive radiation therapy (ART) capacity with increased treatment technique flexibility. The HyperSight im...

Development and Implementation of MRI-Only Simulation, Planning and Treatment Workflow for Pelvic Radiotherapy Using Synthetic CT on MR-Linac

Authors: Peter Balter, Elaine Eunnae Cha, Seungtaek Choi, Yao Ding, Eun Young Han, Yusung Kim, Rajat J. Kudchadker, Belinda Lee, Surendra Prajapati, Reza Reiazi, Ergys D. Subashi, Sarath Vijayan, Jinzhong Yang, Yao Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: This study evaluates the feasibility of an MR-only simulation, planning, and treatment (MROSPT) workflow for pelvic cancer patients using synthetic CT generated from MRI data. By validating s...

Development of a Proton CT System Based on 2D Scintillation Detection

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...

Direct Dose Verification in Liver SBRT Utilizing an Accumulative Daily CBCT Algorithm

Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai

Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...

Fast Synthetic-CT-Free Dose Calculation in MR Guided RT

Authors: Claus Belka, Stefanie Corradini, George Dedes, Nikolaos Delopoulos, Christopher Kurz, Guillaume Landry, Ahmad Neishabouri, Domagoj Radonic, Adrian Thummerer, Niklas Wahl, Fan Xiao

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, LMU Munich, Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO)

Abstract Preview: Purpose: In MR-guided online adaptive radiotherapy, MRI lacks tissue attenuation information necessary for accurate dose calculations. Instead of using deep learning methods to generate synthetic CT i...

Getting in Focus: Review of Current Focal Spot Size Testing Methods with Flat Panel Digital Radiography Detectors

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...

Inter-Patient Adaptive Radiotherapy (IPART): A CT Simulation and Planning Free Approach Enabling Immediate Treatment Access for Patients.

Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...

Intra-Organ Blood Vessel Mapping in Mice for Improved Pre-Clinical Radiation Dosimetry

Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow

Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...

Real-Time Automatic Treatment Planning System (RT-AutoTPS) for Volumetric Modulated Arc Radiotherapy (VMAT)

Authors: Steve B. Jiang, Austen Matthew Maniscalco, Dan Nguyen, Chenyang Shen, Jiacheng Xie, Shunyu Yan, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Although treatment planning systems (TPSs) can handle dose calculation and plan optimization automatically, planning for radiotherapy still requires extensive efforts and expertise from a mul...

Using a Generative Adversarial Network (GAN) for Source Particle Generation in Monte Carlo Radiation Therapy Simulations

Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions

Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...