Search Submissions 🔎

Results for "center voxel": 53 found

4D CBCT Reconstruction Using Denoising Diffusion Implicit Models

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...

A Topological Technique to Unify Image Texture and Morphology to Enhance Radiomic Feature Representations

Authors: David Brizel, Kyle J. Lafata, Jian-Guo Liu, Yvonne M Mowery, Yvonne M Mowery, William Paul Segars, Jack B Stevens

Affiliation: Department of Physics, Duke University, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh

Abstract Preview: Purpose: To develop a technique to quantify tumor topology using a unifying mathematical framework that integrates texture and morphology and to evaluate its feasibility as a prognostic biomarker for ...

An Optimal-Mass-Transport-Based Mathematical Model Applied to Brain DCE-MRI to Differentiate Brain Metastases Recurrence from Radiation Necrosis

Authors: Aditya P. Apte, Xinan Chen, Joseph O. Deasy, Ramesh Paudyal, Kyung Peck, Amita Shukla-Dave, Nathaniel Swinburne, Robert J. Young

Affiliation: Department of Radiology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: We apply our novel formulation of unbalanced-regularized-optimal-mass-transport (urOMT) theory to brain DCE-MRI data to quantify and visualize the behaviors of fluid flows in post-treatment f...

Assessment of Off-Target Dose for Curative Treatment of Pregnant Head and Neck Cancer Case: A Monte-Carlo Study

Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park

Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital

Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...

Automated Determination of Deteriorations in Proton Therapy Plan Quality Using Daily Cone Beam CT As a Predictor of Need for Adaptive Replans for Head and Neck Cases

Authors: Matthew J Ferris, Jason K Molitoris

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland

Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...

BEST IN PHYSICS THERAPY: Population-Based Automated Organs-at-Risk Contouring Outlier Detection and Visualization without Requiring Patient-Specific Reference Contour

Authors: Rex A. Cardan, Carlos E. Cardenas, Quan Chen, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Yi Rong, Dennis N. Stanley, Natalie N. Viscariello, Libing Zhu

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, Mayo Clinic Arizona, University of Alabama at Birmingham

Abstract Preview: Purpose: Manual verification of organs-at-risk(OARs) delineations is a critical yet time-intensive process, often susceptible to unintentional oversights. To assist the reviewing process, a population...

Bgrt Patient Eligibility Check Via Comparing User Defined Ring Around the Biologically Tracking Zone (BTZ) in PET Images

Authors: Resat Aydin, Brett Lewis, Jayesh Mistry, Roland Teboh

Affiliation: HUMC, Hackensack University Medical Center

Abstract Preview: Purpose:
We developed a Python-based solution to systematically quantify and detect fluorodeoxyglucose (FDG) uptake beyond a predefined Biologically Tracking Zone (BTZ) in PET images. This method i...

CT-Free PET Imaging: Synthetic CT Generation for Efficient and Accurate PET-Based Planning

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
PET is used in radiotherapy workflows for accurate target delineation. However, a separate CT scan is typically required for attenuation correction in PET imaging and for registering PET-d...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Commissioning a Fixed Beamline Ultra-High Dose Rate Proton Therapy System

Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...

Comparative Analysis of Nine Deep Learning Architectures for Variable Density Grappa 1H Magnetic Resonance Spectroscopy Imaging (MRSI) Reconstruction

Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang

Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center

Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...

Comparing SPECT Dose Reconstruction Algorithm Accuracy As a Function of Imaging Parameters

Authors: Srinivas Cheenu Kappadath, Brian Michael Kelley, Benjamin P. Lopez

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Imaging systems are subject to errors from finite spatial resolution and voxel size. This work demonstrates their effect on dose algorithm {Monte Carlo (MC), dose-volume kernel (DVK), and ...

Compressed Radiotherapy Treatment Planning (CompressRTP): A New Paradigm for Rapid and High-Quality Treatment Planning Optimization

Authors: Gourav Jhanwar, Mojtaba Tefagh, Masoud Zarepisheh

Affiliation: The University of Edinburgh, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
Radiotherapy treatment planning involves solving computationally-intensive and time-consuming optimization problems. Central to these problems is a large matrix known as the dose-influence...

Development and Validation of a Deep Learning-Based Auto-Segmentation Module for Vestibular Schwannoma

Authors: John Byun, Steven D Chang, Cynthia Fu-Yu Chuang, Xuejun Gu, Melanie Hayden Gephart, Yusuke Hori, Fred Lam, Gordon Li, Lianli Liu, Weiguo Lu, David Park, Erqi Pollom, Elham Rahimy, Deyaaldeen Abu Reesh, Scott Soltys, Gregory Szalkowski, Lei Wang, Xianghua Ye, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Neurosurgery, Stanford University, Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Accurate and automated delineation of vestibular schwannoma (VS) volume is crucial for disease management, as both treatment approaches (stereotactic radiosurgery and invasive surgery) and mo...

Development of a GPU-Based Dose Calculation Engine for MRI-Guided Proton Therapy

Authors: Yaowen Cao, Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Xiaogang Yuan

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: Magnetic resonance imaging (MRI)-guided proton therapy is an innovative technology that combines superior soft tissue imaging capabilities of MRI with the high dose conformity of proton thera...

Development of a Visualization Tool for LET and Proton Spot Mapping for PB Treatment Planning

Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway

Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...

Dose Evaluation of Multiple Gammatiles in Heterogeneous Brain Models Using Egs_Brachy

Authors: Fatemeh Akbari, Artemis Dalby, Nelson A. Miksys, Prarthana Pasricha, Rowan M. Thomson

Affiliation: Ackerman Cancer Center, Carleton University

Abstract Preview: Purpose: To investigate dose evaluations for GammaTile brachytherapy, a novel treatment for brain malignancies. The analysis focuses on the impact of tissue heterogeneities, including the presence of ...

Dosimetric Changes of Magnetic Control System to Improve Anatomy in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Chang-Sei Kim, Yeongoh Ko, Anna E. Rodrigues

Affiliation: Duke University, Chonnam National University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced toxicities in bowel remains a challenge for SBRT. Due to sharp dose falloffs, small displacements of the bowel can lead to meaningful dose reduction. Remote magnetic navigat...

Enhancing Adaptive Radiotherapy Segmentation with a 3D Unet Framework and Prior Fraction Information

Authors: Jennifer L. Dolan, Chengyin Li, Parag Parikh, Doris N. Rusu, Kundan S Thind

Affiliation: Henry Ford Health, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The time and resource demands of online Adaptive Radiation Therapy (ART) can limit its widespread clinical adoption and potentially impact patient throughput. To address this, we developed a ...

Enhancing T2-Weighted Brain MRI Resolution across Orientations Using AI-Based Volumetric Reconstruction

Authors: Mengqi Shen, Meghna Trivedi, Tony J.C. Wang, Andy (Yuanguang) Xu, Yading Yuan

Affiliation: Columbia University Medical Center, Dept of Med Hematology & Oncology, Data Science Institute at Columbia University, Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center

Abstract Preview: Purpose: T2-weighted (T2w) images are critical for identifying pathological changes due to their superior contrast in differentiating tissue types. However, they often lack detailed anatomical resolut...

Evaluating the Impact of Beam Spot Spacing on Dose Rates and Field Uniformity for Small Animal Proton Ultra-High Dose Rate Irradiation

Authors: Jack Biondo, Audrey Magness, Anthony E. Mascia, Zhiyan Xiao, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center

Abstract Preview: Purpose: Proton FLASH-RT has shown promise reducing normal tissue toxicity while maintaining tumor control. However, in vivo experiments critically depend on achieving ultra-high dose rate (UHDR) and ...

Fast Synthetic-CT-Free Dose Calculation in MR Guided RT

Authors: Claus Belka, Stefanie Corradini, George Dedes, Nikolaos Delopoulos, Christopher Kurz, Guillaume Landry, Ahmad Neishabouri, Domagoj Radonic, Adrian Thummerer, Niklas Wahl, Fan Xiao

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, LMU Munich, Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), National Center for Radiation Oncology (NCRO), Heidelberg Institute for Radiation Oncology (HIRO)

Abstract Preview: Purpose: In MR-guided online adaptive radiotherapy, MRI lacks tissue attenuation information necessary for accurate dose calculations. Instead of using deep learning methods to generate synthetic CT i...

Functional Liver Image Guided Radiation Planning Using MRI with a Contrast Agent

Authors: Kenneth L. Homann, Natalie A Lockney, Hong Zhang

Affiliation: Department of Radiation Oncology, Vanderbilt University Medical Center, Vanderbilt University Medical Center

Abstract Preview: Purpose: The aim of this study is to develop a treatment planning methodology utilizing liver functional imaging via contrast-enhanced Magnetic Resonance Imaging (MRI) in patients undergoing stereotac...

High-Quality Patchnet (HQ-PatchNet) for Synthetic CT Generation in Head & Neck Imaging

Authors: So Hyun Ahn, Chris Beltran, Byongsu Choi, Jeong Heon Kim, Jin Sung Kim, Bo Lu, Justin Chunjoo Park, Bongyong Song, Jun Tan

Affiliation: Mayo Clinic, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Ewha Medical Research Institute, Ewha Womans University College of Medicine, UC San Diego, Yonsei University College of Medicine

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) is widely used in IGRT for patient positioning but suffers from low resolution and poor soft tissue contrast. Synthetic CT (sCT) generated from CBCT ad...

Identifying Candidates for Endobronchial Valve (EBV) Treatment for Patients with Moderate to Severe Emphysema: Exploring the Use of Estimated Lung Elasticity Using a Biomechanically Based Model Derived from CT Image Data

Authors: Ryan Andosca, Peter Boyle, Grace Hyun Kim, Minji Victoria Kim, Michael Vincent Lauria, Michael F. McNitt-Gray, Gabriel Melendez-Corres, Jack Neylon, Brad Stiehl, Pang Yu Teng

Affiliation: David Geffen School of Medicine at UCLA, University of California, Los Angeles, UCLA Department of Radiology, Department of Radiation Oncology, University of California, Los Angeles, UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Endobronchial Valves (EBV) are one of the few treatment options for patients with moderate to severe emphysema. Eligibility is typically assessed from CT image data analysis including Emphyse...

Image Quality-Based Clinical CT Cohort Selection from Midrc Using a Multi-Institutional Phantom Dataset

Authors: John M. Boone, Andrew M. Hernandez, Paul E. Kinahan, Michael F. McNitt-Gray, Jeffrey H. Siewerdsen, Ali Uneri

Affiliation: University of California, Johns Hopkins Univ, UT MD Anderson Cancer Center, David Geffen School of Medicine at UCLA, University of Washington, UC Davis Health

Abstract Preview: Purpose: Measuring image quality (IQ) in large clinical databases, such as the Medical Imaging and Data Resource Center (MIDRC), is challenging due to the inherent complexity of image content and the ...

Image Similarity Measurement Based on Handcrafted and Deep Learning Radiomics

Authors: John Ginn, Chenlu Qin, Deshan Yang

Affiliation: Duke University, Department of Radiation Oncology, Duke University

Abstract Preview: Purpose: Clinical implementation of auto-segmentation tools has been hindered by poor interpretability and generalizability of AI models, necessitating the development of automated contour quality ass...

Inter-Fraction Monitoring of Brain Metastases Resection Cavities during Fractionated Stereotactic Radiosurgery on the 0.35 T MRI-Linac

Authors: Eyub Y. Akdemir, Gregory A Azzam, Rupesh Kotecha, Gregory J. Kubicek, Natalia Lutsik, Eric Mellon, Siamak P. Nejad-Davarani, Parag Parikh, Karen C. Snyder

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Department of Radiation Oncology, University of Miami, Henry Ford Health

Abstract Preview: Purpose: Resection cavity volumes shrink gradually over time after surgical resection of brain metastases. Fractionated stereotactic radiosurgery (fSRS) is often delivered to the cavity to prevent rec...

Inter-Patient Registration Methods for Voxel-Based Analysis in Lung Cancer

Authors: Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Sudharsan Madhavan, Nikhil Mankuzhy, Nishant Nadkarni, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Voxel-based analysis (VBA) requires accurate topology-preserving inter-patient deformable image registration (DIR). This study assessed whether guiding a DIR method with geometric priors of t...

Investigating CT-Based Lung Ventilation Heterogeneity As a Biomarker for COPD Severity

Authors: Shiho Amster, Ryan Andosca, Igor Barjaktarevic, Michael Vincent Lauria, Daniel A. Low, Dylan P. O'Connell, Ann Raldow, Brad Stiehl

Affiliation: Department of Pulmonology, University of California Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Image-based biomarkers could be useful for disease diagnosis and prognosis, especially in heterogeneous lung diseases like COPD. The purpose of this study is to assess the feasibility of usin...

Investigating Interstitial Fluid Pressure and Hydraulic Conductivity By Examining the Biophysical Properties of Drug Transport Using Cross Voxel Exchange Model and Dynamic Contrast Enhanced MRI

Authors: Catherine Coolens, Janny Yeyoung Kim, Michael Milosevic, Noha Sinno

Affiliation: Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: In solid tumors, Interstitial fluid pressure (IFP) acts as a barrier to molecular transport to the tumor center and serves as a predictor of cancer patients’ treatment responsiveness. The nov...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Medical Data Handler: A Research-Oriented Graphical User Interface for Dicom Processing, Image Analysis, and Data Management

Authors: Andrew R. Godley, Steve B. Jiang, Mu-Han Lin, Austen Matthew Maniscalco, Dan Nguyen, Yang Kyun Park

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Preparing DICOM datasets for research and education is challenging due to the complexity of the format and the necessity for patient-specific handling. Existing workflows demand substantia...

Monte Carlo Simulation of Dose Perturbations in HAM Applicator HDR Brachytherapy Treatments

Authors: Sam Beddar, Brett Bocian, David B. Flint, Benjamin Abraham Insley, Patrick James Jensen, Rachael M. Martin Paulpeter, Joshua S. Niedzielski, Luis Augusto Perles, Reza Reiazi, Gabriel O. Sawakuchi

Affiliation: University of Miami, MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Empyrean Medical Systems, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The Harrison-Anderson-Mick (HAM) applicator is an Ir-192 High-Dose-Rate (HDR) intraoperative radiotherapy device. It features a silicone body with embedded catheters that guide the Ir-192 sou...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Multi-Path Deep Learning Model for Predicting Post-Radiotherapy Functional Liver Imaging in Patients with Hepatocellular Carcinoma

Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...

Multi-Scale, Multi-Task Framework with Jacobian Descent for Multi-Plan Dose Prediction in Sequential Boost Radiotherapy

Authors: Steve B. Jiang, Mu-Han Lin, Yu-Chen Lin, Austen Matthew Maniscalco, Dan Nguyen, David Sher, Xinran Zhong

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, UT Dallas

Abstract Preview: Purpose:
Sequential boost radiotherapy (RT) poses a challenge in allocating dose across multiple plans while protecting organs at risk (OARs). Clinicians must decide whether OAR sparing should occu...

Noise Sensitivity of Benchmark Whole-Body CT Segmentation Models: Totalsegmentator and Vista3D Performance on an Independent Dataset

Authors: Samuel L. Brady, Shruti Hegde, Alexander Knapp, Usman Mahmood, Joseph G. Meier, Elanchezhian Somasundaram, Zachary Taylor

Affiliation: Cincinnati Children's Hospital Medical Ctr, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Cincinnati Children's Hospital Medical Center, Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To assess how two benchmark multi-organ CT segmentation models respond to varying image noise levels.
Methods:
This study utilized the pediatric CT dataset from The Cancer Imaging Ar...

Novel Automatic Detection of Surface Brachytherapy Applicators and Catheters on Vibe MR Images

Authors: Ivan M. Buzurovic, Evangelia Kaza

Affiliation: Department of Radiation Oncology, Dana-Farber/Brigham and Women’s Cancer Center, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Recent advances allow for depiction of surface brachytherapy flap applicators using MRI, with empty catheters detected by signal intensity reduction. As manual catheter detection is subjectiv...

Performance Evaluation of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System.

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: The purpose of this work is to describe the design and development of a newly developed upright-geometry dedicated breast CT system and to quantitatively and qualitatively evaluate its imagin...

Predicting Reactive Oxygen Species Generated through Photoactivation of Targeted Laser Therapy in-Silico

Authors: David Alcorta, Joseph Farina, Timothy Haystead, Philip Hughes, Keshav Jha, Mark Oldham, Victoria J. P. Radosova

Affiliation: Duke University Department of Pharmacology and Cancer Biology, Medical Physics Graduate Program, Duke University, Duke University Department of Medicine, Duke University, Duke University Pharmacology and Cancer Biology, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: This study attempts to simulate the activation of targeted photodynamic molecules using visible laser light and characterize the direct Reactive Oxygen Species (ROS) generated by Cherenkov an...

Quantification of Iodine and Calcium Materials through HU Spectral Curve Analysis in Dual-Energy CT for Radiotherapy Planning

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Maria F. Chan, Yabo Fu, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Lee, Tianfang Li, Xiang Li, Jean M. Moran

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Iodine maps derived from Dual-Energy CT (DECT) provide critical biological information for radiotherapy treatment planning, but clinical iodine maps often mistakenly include bones due to insu...

Quantifying Respiratory Motion Effects in Lung Cancer Radiotherapy Using 4DCT Voxel Analysis

Authors: Chih-Chiang Chang, Chingyun Cheng, Ben Durkee, Minglei Kang, Elissa Khoudary, Yangguang Ma, Xuanqin Mou, YuFei Wang, Tengda Zhang, Wang Zhengda

Affiliation: Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, The First Affiliated Hospital of Zhengzhou University, School of Software Engineering, Xi’an Jiaotong University, School of information and communications engineering, Faculty of electronic and information engineering, Xi’an Jiaotong University, Department of Medical Physics, Columbia University, University of Pennsylvania, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: This study presents a voxel-based analysis method based on deformable image registration to accurately quantify respiratory-induced motion and deformation of both targets and organs at risk (...

Reducing Variable Rbe in Oars for HN, Breast, and Prostate Proton Therapy Using a Scripted Spot-Delete Technique

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: Linear energy transfer (LET) and variable relative biological effectiveness (RBE) evaluation are important steps in the future of proton therapy, moving beyond RBE=1.1 for all treatment plann...

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Time and Energy-Encoded CT Reconstruction

Authors: Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: Conventional computed tomography (CT) measures the collective attenuation of primary photon fluence and then reconstructs the 3D images without using the timing information of individual phot...

Toward Harmonized AI-Based Quantitative CT: A Voxel-Printed, Patient Specific Phantom for Cross-Platform Harmonization

Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...

Tumor Density on Time-Weighted Mid-Position Images for Thoracic Tumors

Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...

Two-Stage Clustering and Auto Machine Learning to Predict Chemoradiation Response in Tumor Subregions on FDG PET for La-NSCLC

Authors: Stephen R. Bowen, Shijun Chen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Qianqian Tong, Jiajie Wang, Shouyi Wang, Faisal Yaseen

Affiliation: The University of Texas at Austin, Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington

Abstract Preview: Purpose: Tumor subregion clustering and prediction of region-specific response can augment assessments and adaptive treatment decisions. A modeling framework was constructed to predict chemoradiation ...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Voxel-Dose Implications of Single-Compartment Dosimetry for Ablative 90Y-Radioembolization Segmentectomy

Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...

Weakly Supervised Spatial Implicit Neural Representation Learning for 3D MRI-Ultrasound Deformable Image Registration in HDR Prostate Brachytherapy

Authors: Michael Baine, Yang Lei, Yu Lei, Ruirui Liu, Tian Liu, Jing Wang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center

Abstract Preview: Purpose: Accurate 3D deformable registration of MRI and ultrasound (US) is essential for real-time image guidance during high-dose-rate (HDR) prostate brachytherapy. However, MRI-US registration of th...

Weekly Changes in Ventilation Response for Photon and Proton Patients during Radiotherapy

Authors: Kristy K. Brock, Austin Castelo, Yulun He, Zhongxing Liao, Rebecca Lim, Radhe Mohan, Caleb O'Connor, Tien T Tang, Uwe Titt

Affiliation: University of Washington, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Conformal dose distributions in proton radiotherapy promise to reduce normal tissue toxicity such as radiation-induced pneumonitis, but this has not been fully realized in clinical trials. To...