Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens
Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI
Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...
Authors: Michael W. Kissick, Chung Tin Lo, Jamie R McClelland, Niek Schreuder, Tracy Underwood
Affiliation: Hawkes Institute, University College London, Leo Cancer Care
Abstract Preview: Purpose: The emerging field of upright radiotherapy raises the question of how respiratory motion differs between upright and supine treatment postures. Therefore, we have developed a versatile pipeli...
Authors: Wenfeng He, Tian Liu, Pretesh Patel, Richard L.J. Qiu, Keyur Shah, Tonghe Wang, Xiaofeng Yang, Chulong Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, Emory University, Medical Physics Graduate Program, Duke Kunshan University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: This study introduces a tracking-free approach to reconstruct 3D ultrasound (US) volumes from 2D freehand US scans. By eliminating the reliance on external tracking systems, this method aims ...
Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal
Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre
Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...
Authors: Doris Dimitriadis/Dimitriadou, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Adam Olson
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC
Abstract Preview: Purpose: The objective of this study was to qualitatively evaluate Prostate Hypersight Cone-Beam CT (HSCBCT) images and assess its capability for Limbus auto-contouring. The qualitative evaluation and...
Authors: Robert K Chin, Klea Hoxha, Erika Jank, Jesus Juarez, Eulanca Yuka Liu, Dylan P. O'Connell, X. Sharon Qi, Ricky R Savjani
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, Los Angeles, UCLA Radiation Oncology
Abstract Preview: Purpose:
Daily cone beam CT (CBCT) images are acquired prior to each radiotherapy treatment for verifying patient positioning. HyperSight is an advanced imaging solution that replaces standard CBCT...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang
Affiliation: Kyoto University, Osaka Metropolitan University
Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...
Authors: Richard J Barth, Brook Kennedy Byrd, Roberta DiFlorio-Alexander, Misty J Fox, Venkat Krishnaswamy, Keith D. Paulsen, Timothy B Rooney
Affiliation: Cairn Surgical Inc., Dartmouth Health, Thayer School of Engineering, Dartmouth Hitchcock Medical Center, University of Virginia Health, CairnSurgical Inc.
Abstract Preview: Purpose: Supine breast MRI enables precise surgical planning with demonstrated benefit in decreasing positive margin rates during BCS. However, acquiring supine breast MRI scans in a secondary imaging...
Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical
Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...
Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura
Affiliation: University of Massachusetts Chan Medical School
Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...
Authors: Kimberly Chan, Anke Henning, Mahrshi Jani, Andrew Wright, Xinyu Zhang
Affiliation: Advanced Imaging Research Center (AIRC), UT Southwestern Medical Center
Abstract Preview: Purpose: To evaluate the performance of multiple deep learning architectures for MRSI reconstruction and determine their effectiveness in maintaining high-resolution metabolite mapping while reducing ...
Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Zhuo Chen, Tinsu Pan, Allan Thomas
Affiliation: Mallinckrodt Institute of Radiology, Washington University School of Medicine, WashU Medicine, UT MD Anderson Cancer Center
Abstract Preview: Purpose: Misregistration between data-driven gated (DDG)-PET and CT can limit the benefits of motion correction and improved localization and quantitation. DDG-CT offers a solution to these issues. He...
Authors: Magdalena Bazalova-Carter, James Day, Xinchen Deng
Affiliation: University of Victoria
Abstract Preview: Purpose:
Ring artifacts in Photon-Counting Computed Tomography (PCCT) images can degrade image quality. this study aims to suppress ring artifacts with a novel autoencoder-based framework that leve...
Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita
Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital
Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...
Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...
Authors: Kaelyn Becker, Xenia Ray
Affiliation: University of California, San Diego, University of California San Diego
Abstract Preview: Purpose: Ethos 2.0 with HyperSight (Varian Medical Systems) imaging enables nearly fully automated offline adaptive radiotherapy including automated deformation of targets and recalculation on the Hou...
Authors: Kristina Bjegovic, Yong Chen, Lucia Rodriguez Gonzalez, Marti Roper, Liangzhong Xiang
Affiliation: University of California, Irvine, University of California Irvine, University of Oklahoma Health Sciences Center, University of Oklahoma Health Science Center
Abstract Preview: Purpose: Proton therapy is an increasingly popular cancer treatment due to its precision, enabled by the Bragg Peak (BP), which minimizes side effects. This profile necessitates in-patient localizatio...
Authors: Lei Ren, Jie Zhang
Affiliation: University of Maryland School of Medicine
Abstract Preview: Purpose: 4D-CBCT is valuable for imaging anatomy affected by respiratory motions to guide radiotherapy delivery. However, 4D-CBCT often has undersampled projections acquired in each respiratory phase ...
Authors: Hassan Bagher-Ebadian, Justine M. Cunningham, Anthony J. Doemer, Mohammad M. Ghassemi, Joshua P. Kim, Benjamin Movsas, Kundan S Thind
Affiliation: Michigan State University, Henry Ford Health
Abstract Preview: Purpose: Reduction of noise in medical images critically enables improved accuracy in delineating tumors and organs at risk, leading to more precise treatment planning and safer image-guided radiation...
Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Xiuxiu He, Tianfang Li, Xiang Li, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
This work aims to develop an innovative technique to evaluate patients’ daily respiratory pattern using three-dimensional (3D) deformation vector fields (DVF) derived from a free-breathing...
Authors: Laura Bennett, Matthew Charles, Greg Cooley, John M. Floberg, Ryan Hutten, Elissa Khoudary, Nicholas Lynch, Kaili Ranta, Jordan M. Slagowski, Trevor Wilson
Affiliation: University of Pennsylvania, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, University of Wisconsin-Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: To evaluate the impact of an iterative cone beam CT with metal artifact reduction (iCBCT+MAR) reconstruction algorithm (HyperSight TrueBeam 4.1, Varian Medical Systems) on image quality and s...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.
Methods: Dose calculations in water phan...
Authors: Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura, Yukine Shimizu
Affiliation: Kyoto University, Kyoto Univercity, Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To predict tumor positions in markerless dynamic tumor tracking (ML-DTT)-VMAT by compensating for the asynchrony between the tumor and the diaphragm.
Methods: Rotational fluoroscopic X-ray...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers Sørensen, Matthias Würl
Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam
Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.
Methods:...
Authors: Jihun Kim, Jin Sung Kim, Jun Won Kim, Yong Tae Kim, Chanwoong Lee, Jihyn Pyo, Young Hun Yoon
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine
Abstract Preview: Purpose: Although segmentation foundation models have recently demonstrated promising zero-shot performance on natural images, its clinical application to magnetic resonance (MR) images still requires...
Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda
Affiliation: Yale University School of Medicine, Yale University
Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...
Authors: Manju Liu, Weiwei Sang, Yanyan Shi, Zhenyu Yang, Fang-Fang Yin, Chulong Zhang, Lihua Zhang, Rihui Zhang
Affiliation: Jiahui International Hospital, Jiahui International Hospital, Radiation Oncology, Duke Kunshan University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: This study aims to transform cone-beam computed tomography (CBCT) images acquired from deep inspiration breath-hold (DIBH) breast cancer patients into high-fidelity synthetic CT (sCT) images....
Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC
Abstract Preview: Purpose: The goal of the HyperSight® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...
Authors: James M. Balter, Alexander Moncion, Ikechi S Ozoemelam
Affiliation: University of Michigan
Abstract Preview: Purpose: Sequential dual-energy cone beam computed tomography (DE-CBCT) integrated with an online adaptive platform could potentially improve soft tissue visualization for more accurate anatomical del...
Authors: Geoffrey D. Clarke, Laura A. Cox, Alexander J Moody, Peter W Nathanielsz, Bowen Yang
Affiliation: Wake Forest University School of Medicine, University of Texas Health Science Center at San Antonio, Texas Biomedical Research Institute
Abstract Preview: Purpose:
Recent studies show diagnostic value of myocardial strain analysis for left ventricular (LV) function using cardiac magnetic resonance imaging (CMR). RV function analysis is more challengi...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of São Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin
Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...
Authors: Ming Chao, Thomas Chum, Tenzin Kunkyab, Yang Lei, Tian Liu, Richard G Stock, Hasan Wazir, Junyi Xia, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose:
This study aims to develop effective strategies for multi-organ segmentation of pelvic cone-beam computed tomography (CBCT) images based on transformer models to facilitate adaptive radiat...
Authors: Jia Wang, Vani Yadav
Affiliation: Stanford University
Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...
Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.
Methods: Traditional WLT that uses cone and s...
Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing
Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...
Authors: Yussuf A. Abdelal, Junguo Bian, Michael Delafuente, Sebastien A. Gros, Hyejoo Kang, Luke Layman, M Mahesh, John C. Roeske
Affiliation: Department of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Johns Hopkins Univ
Abstract Preview: Purpose: This study evaluates the feasibility of optimizing 4DCBCT imaging protocols for gated lung SBRT, by reducing dose while maintaining the image quality required for accurate patient alignment.<...
Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...
Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...
Authors: Michael Baine, Charles Enke, Yang Lei, Yu Lei, Ruirui Liu, Su-Min Zhou
Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Radiation Oncology, University of Nebraska Medical Center
Abstract Preview: Purpose: This study presents a framework for generating synthetic CT images using a Cycle Diffusion model, which can be utilized to enhance needle conspicuity in ultrasound-guided prostate HDR brachyt...
Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman
Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University
Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...
Authors: Joana Antunes, Scott James Bright, David B. Flint, Mojtaba Hoseini-Ghahfarokhi, Mandira Manandhar, Poliana Marinello, Gabriel O. Sawakuchi, Tingshi Su
Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Laboratory of Instrumentation and Experimental Particle Physics; Faculty of Science of University of Lisbon, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, MD Anderson Cancer Center
Abstract Preview: Purpose: To study the accuracy of relative biological effectiveness (RBE) models to predict the RBE of a comprehensive panel of pancreatic cancer cell lines.
Methods: Clonogenic cell survival w...
Authors: Bulent Aydogan, Xiaochuan Pan, Erik Pearson, Zheng Zhang
Affiliation: The University of Chicago
Abstract Preview: Purpose: Motion management remains one of the significant challenges in external beam radiation therapy (RT). We are developing time-resolved cone-beam computed tomography (trCBCT) for imaging during ...
Authors: Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, David W. Meer, Manoj Narayanan, Mingshan Sun, Don Vernekohl, Ray Yang
Affiliation: RefleXion Medical
Abstract Preview: Purpose: To implement post-treatment review of delivered dose fractions on RefleXion X1 accounting for independent detection of transmitted beamlets and transient dose fluctuations of individual pulse...
Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai
Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...
Authors: Owen Thomas Dillon, Andrew Kanawati, Tess Reynolds
Affiliation: Westmead Hospital, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose: Metal artefacts from implanted hardware and surgical tools remain a limitation for widespread adoption of intraoperative CBCT imaging. Gantry-based non-circular imaging trajectories have emer...