Search Submissions πŸ”Ž

Results for "complexity ptv": 11 found

A Knowledge-Based Approach for High-Quality Accelerated Partial Breast Irradiation Using Stereotactic Body Radiotherapy

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Allison Dalton, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: External-beam Accelerated Partial Breast Irradiation (APBI) using stereotactic-body radiotherapy (SBRT) is increasingly adopted as an alternative to whole-breast radiation, offering targeted ...

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Automatic Breast VMAT Planning Using Script and Rapidplan on Eclipse

Authors: Maria Jose Almada, Bruno Forti, Patricia Murina, Carlos Daniel Venencia

Affiliation: Instituto Zunino - Fundacion Marie Curie, Dra.

Abstract Preview: Purpose: The use of VMAT for the breast requires duplication of the patient's CT, several planning structures, and patient-specific dose-volume constraints depending on the patient's anatomy, fraction...

Developing and Evaluating the First Pre-Treatment Physics Plan Checklist for Error Detection in Biology-Guided Radiotherapy (BgRT)

Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong

Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...

High Resolution Head Motion Correction Based on Pilot Tone Signals – a Calibration-Free Method

Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin

Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...

Investigation into the Robustness of Spine Stereotactic Body Radiotherapy Plans to Patient Setup Errors

Authors: Yukio Fujita, Syoma Ide, Fumiki Ito, Kei Ito, Satoshi Kito, Keiko Murofushi, Yujiro Nakajima, Yuhi Suda, Kentaro Taguchi, Naoki Tohyama, Fumiya Tsurumaki, Riku Watanabe

Affiliation: Komazawa University Graduate School, Komazawa University, Tokyo Metropolitan Cancer and Infectious Diseases Center Komagome Hospital

Abstract Preview: Purpose: Spine stereotactic body radiotherapy (SBRT) demands high precision due to the target's proximity to the spinal cord and steep dose gradients, which complicate treatment planning. Consequently...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Sentinel: Development and Implementation of an Automated, Passive Varian Log File and Treatment Plan Analysis

Authors: Leon Dunn

Affiliation: IsoAnalytics Pty. Ltd.

Abstract Preview: Purpose: The purpose of this work is to present the development and results of an automated Varian Trajectory Log file processing software platform called Sentinel (IsoAnalytics Pty. Ltd.).
Methods...

Uncertainties on Synthetic-CT Generation from CBCT: Another Layer of Complexity in Abdominal Adaptive Radiotherapy

Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.

Methods: CT and CBCT images from 65 abdominal pat...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...