Search Submissions 🔎

Results for "cone factors": 77 found

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A Diffusion-Based AI Framework for Continuous Deformable Image Registration and Time-Resolved Dynamic CT Generation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Gregory Szalkowski, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Respiratory motion management is crucial for accurate radiation delivery to moving targets while protecting healthy tissue, relying on time-resolved volumetric imaging and continuous deformab...

A Method to Check the Consistency and Reproducibility of VMAT Delivery

Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre

Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...

A Monte Carlo Dosimetry-Based Cell Survival Model Incorporating Spatial and Temporal Heterogeneity for Rpt Preclinical Studies

Authors: Alejandro Bertolet, Michael D. Farwell, Sarah Gitto, Victor V. Onecha, Daniel Pryma, Aladdin Riad

Affiliation: Department of Pathology and Laboratory Medicine, Abramson Cancer Center, Perelman School of Medicine, University of Pennsylvania, Department of Radiology, Perelman School of Medicine, Perelman School of Medicine at the University of Pennsylvania, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Responses to ionizing radiation (IR) strongly correlate with the absorbed dose. At the cellular level, this is typically described by a linear-quadratic relationship provided the cell populat...

A Multi-Institutional Survey of Current Therapeutic Medical Physics Residents’ Satisfaction and Interview Experience

Authors: Seifallah Emam, Gilberto Gonzalez, Anna E. Rodrigues

Affiliation: Duke University, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
To survey current therapeutic medical physics residents on 1) the accuracy with which residency programs were represented during interviews, 2) factors that most strongly impacted resident...

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

Achieving Consistent Calcium Score in Lung Cancer Screening: Influence of Cardiac Phases

Authors: Emi Ai Eastman, Chao Guo, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose:
Smoking is one of the risk factors for coronary artery disease. It is desirable to estimate the coronary artery calcification (CAC), a key biomarker for atherosclerosis and cardiovascular ...

Adapting Newer Treatment Planning Strategy for Uveal Melanoma Cases Using Gamma Knife Radiosurgery

Authors: Deepak Agrawal, Subhash Gupta, Shashanksharad Kale, Gopishankar Natanasabapathi, Manoj Phalak, Dhanabalan Rajasekaran, Surendra Kumar Saini, Subramani Vellaiyan

Affiliation: All India Institute of Medical Sciences (AIIMS), All India Institute of Medical Sciences

Abstract Preview: Purpose:
To evaluate planning strategy for uveal melanoma tumor (UM) in gamma knife stereotactic radiosurgery (GKSRS) using Lightning inverse planning software for treatment planning.
Methods:

An Adaptive Non-Local Means Filtering Method for Denoising CBCT Images Under Low X-Ray Fluence Conditions

Authors: Cem Altunbas, Farhang Bayat

Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic

Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...

An Analytical Framework to Quantify the Effect Obstructing Anatomical Features in Intrafractional Spectral Imaging Using a Dual-Layer Kv Imager

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Marios Myronakis

Affiliation: Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory

Abstract Preview: Purpose:
Dual-layer kV imager (DLI) architecture enables the capability for single-shot dual-energy (DE) intrafraction imaging. As noise from individual DLI layers are primarily uncorrelated, simpl...

An International Survey of High Dose Rate Brachytherapy Dosimetry Practices

Authors: Anna Becker, Tomislav Bokulic, Mauro Carrara, Krzysztof Chelminski, Larry A. DeWerd, Alexis Dimitriadis, Benjamin Kellogg, Malcolm R. McEwen, Zakithi L.M Msimang, Mark J. Rivard, Thorsten Sander, Thorsten Schneider, Jamema Swamidas, Egor Titovich, Paula Toroi, Carlos E. de Almeida, Jacco de Pooter, Liset de la Fuente Rosales, Deborah G. van der Merwe

Affiliation: Radiation and Nuclear Safety Authority, University of Zagreb, National Physical Laboratory, IAEA, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Rio de Janeiro State University, Dosimetry Laboratory, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, Physikalisch-Technische Bundesanstalt, National Metrology Institute, University of the Witwatersrand, Dosimetry and Medical Radiation Physics Section, Division of Human Health, International Atomic Energy Agency, National Research Council, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: The recently published IAEA-TRS-492 international code of practice (CoP) aims at improving traceability, accuracy, and consistency in Brachytherapy Dosimetry. To assess current approaches to ...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Analyzer-Less X-Ray Interferometry with Super-Resolution Methods

Authors: Joyoni Dey, Hunter Cole Meyer, Murtuza Taqi

Affiliation: Louisiana State University

Abstract Preview: Purpose: We propose using super-resolution methods for X-ray grating interferometry without an analyzer with detectors that fail to meet the Nyquist sampling rate needed for traditional image recovery...

Anatomical Noise Power Exponent (β) As an Image-Based Risk Factor for Breast Cancer

Authors: Yile Fang, Leslie Lamb, Nathaniel David Mercaldo, Kai Yang

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To quantitatively evaluate power-law exponent β as a potential image-based breast cancer risk factor.

Methods: Two groups of breast cancer screening cohorts (target vs. control, 20 sub...

Application of the Lymphodose Framework to Brain Tumors: Unveiling the Prognostic Power of Circulating Lymphocyte Doses

Authors: Sophie Bockel, Eric Deutsch, Frederic Dhermain, Ibrahima Diallo, Anh Thu Le, Elaine Limkin, Pauline Maury, Charlotte Robert, Killian Sambourg, Camilla Satragno, Cristina Veres, François de Kermenguy

Affiliation: Gustave Roussy, Département de radiothérapie, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique

Abstract Preview: Purpose:
To study the correlation between the dose to circulating lymphocytes as evaluated by the LymphoDose framework and the incidence of severe radiation-induced lymphopenia (sRIL) in patients t...

Backward Photon Monte Carlo Propagator (BPMCP): Proof of Concept of a Fully Physics-Driven SPECT Reconstruction

Authors: Alejandro Bertolet, Carlos Huesa-Berral, Victor V. Onecha

Affiliation: Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: Radioembolization for liver tumors using 90Y microspheres uses SPECT as confirmatory dosimetry, although 90Y is a pure β-emitter, and SPECT-imaging is only available through subsequent bremss...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Combining Flat-Panel Imaging and Internal BB Markers for Precise HDR Brachytherapy Source Localization

Authors: Yibin Ling, Qihui Lyu, Ke Sheng

Affiliation: University of California Berkeley, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
High Dose Rate (HDR) brachytherapy enables radiation to concentrate on the tumor by sending the high-dose-rate radioactive source directly to the treatment site. On the other hand, the sha...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Correcting for the Cherenkov-to-Dose Conversion for Tset Patients Using Monte Carlo Simulations

Authors: Baozhu Lu, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: Cherenkov intensity can be quantitatively correlated to surface dose but need certain corrections for accurate dose measurements. This study aims to investigate the impact of incident beam an...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Design of Filtimator (Filter + Collimator) for CBCT of Pediatric Cancer Patients Receiving Proton Therapy

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Cone-beam computed tomography (CBCT) doses shall be limited for pediatric patients in clinical settings. Device called Filtimator (filter+collimator) was custom designed to reduce setup CB...

Determining the Optimal CT Tube Voltage for Imaging Bone Structures in Radiotherapy.

Authors: Mohamed Bahaaeldin Mohamed Afifi, Nahla Nagy Ahmad Ataalla, Ahmed A. Eldib

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Optimizing CT imaging parameters is crucial for balancing radiation dose, contrast resolution, and accurate Hounsfield unit representation, particularly in radiotherapy treatment planning. Th...

Development of a Physical Phantom for Assessing Tube Current Modulation in CT Imaging

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Laura Dinwiddie, Benjamin Taylor Heggie, Adam Leon Kesner, Juan Camilo Ocampo Ramos, Graham Joseph Stoddard

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: The objective of this study is to develop a physical phantom to quantify tube current modulation (TCM) and assess the limitations of a TCM model used in Monte Carlo patient CT organ dose esti...

Development of the First Benchtop X-Ray Flash System

Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou

Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta

Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...

Differential Gastrointestinal Responses to Synchrotron-Produced Proton and Electron Irradiation Under Flash and Conventional Conditions

Authors: Luke Connell, Nolan M. Esplen, Elise Konradsson, Albert C. Koong, Ziyi Li, Steven Hsesheng Lin, Kevin Liu, Billy W Loo, Devarati Mitra, Radhe Mohan, Emil Schueler, Takeshi Takaoka, Uwe Titt, Xiaochun Wang, Ming Yang

Affiliation: The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study aimed to assess radiation-induced gastrointestinal (GI) toxicity in mice subjected to abdominal irradiation using protons at ultra-high-dose-rate (UHDR) and conventional dose-rates...

Energy Dependency of Biological Effects from Radiation Scattering Around Medical Implants in Particle Therapy

Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum

Affiliation: Osaka University, Texas A&M University

Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of the Latest Plastic Scintillating Detector System with Probe Sizes of 0.5 × 0.5 mm2 and 1.0 × 1.0 mm2 for Small Field Dosimetry

Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo

Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center

Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...

Evaluation of the Reflexion X1 As a Standalone PET/CT Simulator for Treatment Planning and Treatment Adaptation

Authors: Chunhui Han, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the RefleXion X1 imaging system as a standalone positron emission tomography and computed tomography (PET/CT) simulator for radiotherapy treatment planning and adaptive re-plannin...

Extremity Imaging with Cone-Beam CT (CBCT) Scanner Dedicated for Hip Imaging – What Are the Effective Doses?

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...

Feasibility Study of Deep Learning-Based MRI-to-PET Generation for Rectal Cancer: Overall Survival Prediction and Pathological Complete Response Assessment

Authors: Weigang Hu, Zhenhao Li, Jiazhou Wang, Xiaojie Yin, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose:
This study aims to develop and validate a novel deep learning method to generate synthetic PET images for rectal cancer from MRI data. By incorporating metabolic information from the synth...

Feasibility Study of Single Gantry Angle Proton Minibeam Lattice Radiotherapy

Authors: Anthony Hong Cheol Lim, Rayyan L Mahmood, Alexander Stanforth, Chris C. Wang, Mingyao Zhu

Affiliation: Georgia Institute of Technology, Emory University

Abstract Preview: Purpose: The purpose of this project is to test the feasibility of proton minibeam lattice radiotherapy within an existing clinical setting.
Methods:
The TOPAS code is used to model a scenario i...

Field Output Correction Factors of Novel Shielded and Unshielded Silicon Diode Detectors

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...

From Prediction to Practice: Performance of a Deep Learning-Based Breast Planning Algorithm

Authors: Thomas L. Hayes, Nicholas C. Koch, Han Liu, Qingyang (Grace) Shang, Benjamin J. Sintay, Caroline Vanderstraeten, David B. Wiant

Affiliation: Fuse Oncology, Cone Health, Cone Health Cancer Center

Abstract Preview: Purpose:
This study evaluates the accuracy of a deep learning-based automatic breast planning script in predicting beam energy for breast cancer treatments. The script was validated and implemented...

Image-Guided Adaptive Proton Therapy for Head and Neck Cancer Using a Novel Gantry-Less System

Authors: Philip Blumenfeld, Jon Feldman, Yair Hillman, Michael Marash, Aron Popovtzer, Alexander Pryanichnikov, Shimshon Winograd, Marc Wygoda, Vered Zivan

Affiliation: Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), P-Cure Ltd./Inc., Sharett Institute of Oncology, Hadassah Medical Center, Hebrew University of Jerusalem

Abstract Preview: Purpose:
Image-guided adaptive proton therapy (IGAPT) allows tailored dose adjustments to account for anatomical and physiological changes during treatment. Recent efforts have developed a cost-eff...

Imaging of Mn Washout in the Individual Welder Brain after Wearing Powered Air-Purifying Respirators (PAPRs)

Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park

Affiliation: Purdue University

Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...

Impact of IMRT Beam Scatter and Electronic Noise on Real-Time Kv and Fluoroscopy Image Quality

Authors: Wei Luo, Cameron Thayer-Freeman, Yifeng Zhao

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky

Abstract Preview: Purpose: Real-time Kilovoltage (kV) imaging has emerged as a powerful clinical aid, providing high-precision localization of moving targets during treatment. However, the Megavoltage (MV) treatment be...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

Improving Operational Efficiency in Head and Neck Proton Therapy through Adaptation Analysis

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey

Affiliation: Thompson Proton Center

Abstract Preview: Purpose: Proton therapy plans can be highly sensitive to both anatomical changes and positional errors, making the acquisition of Quality Assurance CT (QACT) images a routine clinical practice during ...

Improving the Robustness of AI-Based Detection and Segmentation for Brain Metastasis By Optimizing Loss Function and Multi-Dataset Training

Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte

Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine

Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...

Investigation of Low Iodine Concentration Detectability of Dual-Energy CT Imaging Using a Customized 3D Printed Phantom

Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...

Investigation of Treatment Planning System (TPS) Algorithms for Helical Tomotherapy Total Body Irradiation (TBI)

Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders

Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health

Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

LLM-Enhanced Multi-Modal Framework for Predicting Pain Relief of Stereotactic Body Radiotherapy for Spine Metastases Using Clinical Factors and Imaging Reports

Authors: John Byun, Steven D Chang, Mingli Chen, Cynthia Chuang, Xuejun Gu, Melanie Hayden Gephart, Yusuke Hori, Hao Jiang, Mahdieh Kazemimoghadam, Fred Lam, Gordon Li, Lianli Liu, Weiguo Lu, David Park, Erqi Pollom, Elham Rahimy, Deyaaldeen Abu Reesh, Scott Soltys, Gregory Szalkowski, Lei Wang, Qingying Wang, Zi Yang, Xianghua Ye, Kangning Zhang

Affiliation: Department of Radiation Oncology, Stanford University, Department of Neurosurgery, Stanford University, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Accurate prediction of pain relief is crucial in determining the clinical effectiveness of Stereotactic body radiotherapy (SBRT) regimen for spine metastases. We propose a deep-learning frame...

Lesion Detection in Contrast Enhanced Cone Beam Breast CT with a Photon Counting Detector: A Monte Carlo Study

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Evaluation of Water-Equivalent Materials for Nanowire-Based Oslds in Flash Radiotherapy

Authors: James Chun Lam Chow, Harry E Ruda

Affiliation: University of Toronto, Princess Margaret Cancer Centre

Abstract Preview: Purpose: FLASH radiotherapy (FLASH-RT) with dose rate greater than 40 Gy/s, has demonstrated potential in reducing normal tissue toxicity while maintaining tumor control. However, accurate and reliabl...

Multi-Omics-Based Prognostic Prediction for Locally Advanced Hypopharyngeal Cancer Treated with Postoperative Chemoradiotherapy: A Dual-Center Study

Authors: Sixue Dong, Chaosu Hu, Weigang Hu, Xiaomin Ou, Jiazhou Wang, Zhen Zhang

Affiliation: Fudan University Shanghai Cancer Center

Abstract Preview: Purpose:
This study aimed to predict the PFS of the patients who were diagnosed with hypopharyngeal cancer and received postoperative chemoradiotherapy by using multi-omics which integrating clinic...

Multi-Region Multiomic Features Improve Random Forest Toxicity Modeling of Radiation Pneumonitis

Authors: Laurence Edward Court, Alexandra Olivia Leone, Zhongxing Liao, Saurabh Shashikumar Nair, Joshua S. Niedzielski, Ramon Maurilio Salazar, Ting Xu

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Radiation Pneumonitis (RP) predictive models often rely on clinical and DVH parameters, but multiomic features from CT imaging and 3D dose distributions from various regions could provide add...

Nausea, Heartburn, K-Edge Imaging: Pepto Bismol As a CT Contrast Agent

Authors: Magdalena Bazalova-Carter, Ross I. Berbeco, James Day, Xinchen Deng, Chelsea Amanda Saffron Dunning, Dianne M. Ferguson, Matthew W. Jacobson, Toby Morris, Marios Myronakis, Jericho Daniel O'Connell, Fides Schwartz, Jainil Shah, Aaron Sodickson

Affiliation: Brigham and Womens Hospital, University of Massachsetts Lowell and Dana-Farber Cancer Institute Boston, Medical Physics Department, Medical School, University of Thessaly, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Washington, University of Victoria, Siemens Healthineers, Dana Farber/Brigham and Women's Cancer Center, Brigham and Women's Hospital

Abstract Preview: Purpose: While CT imaging has advanced with improved machine design, we propose further gains can be achieved by enhancing sensitivity to contrast agents. Current CT sensitivity is limited to 1% bismu...

Neutron Dose Measurements with Multiple Dosimetry Techniques for Fetal Dose Estimation

Authors: Ahmet S. Ayan, Estelle Batin, Austin M. Faught, Peter E. Klages, Eunsin Lee, Collin Nappi, Mina Okello, Meghana Ramani, Zachary X. Richards, Parisa Sadeghi

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University

Abstract Preview: Purpose: Neutron doses are not modelled in proton treatment planning systems, so measurements were taken with two independent dosimeter types to quantify representative neutron fetal doses in pencil b...

Ocular HDR Brachytherapy End-to-End Dose Verification with Iridum-192 Calibrated Oslds

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell

Affiliation: Mount Sinai Beth Israel

Abstract Preview: Purpose: Ocular HDR brachytherapy is used as an alternative treatment for eye cancer, especially with extrascleral extension in the orbit. This complex procedure inserts catheters into the orbit affix...

On Estimating Effective Doses Associated with Different Imaging Protocols for Weight-Bearing Imaging of the Hip with a Dedicated Cone Beam CT (CBCT) Scanner

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...

On the Spectral Changes of Magna-Field Photon Beams Used in Total Body Irradiation

Authors: Larry A. DeWerd, Ahtesham Ullah Khan

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital Würzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Personalized Radiotherapy: A Novel Approach to Multi-Criteria Optimization with Patient-Specific Risk Integration

Authors: Ali Ajdari, Thomas R. Bortfeld, Zhongxing Liao, Mara Schubert, Katrin Teichert

Affiliation: The University of Texas MD Anderson Cancer Center, Department Of Radiation Oncology, Massachusetts General Hospital (MGH), Massachusetts General Hospital & Harvard Medical School, Fraunhofer ITWM

Abstract Preview: Purpose: Radiotherapy (RT) treatment planning often involves solving a multi-criteria optimization (MCO) problem. Conventionally, MCO considers a set of generic (population-wide) dosimetric criteria, ...

Prediction of Metastasis-Free Survival in Patients with Prostate Adenocarcinoma Using Primary Tumor and Lymph Node Radiomics from Pre-Treatment PSMA PET/CT Scans.

Authors: Ozan Cem Guler, William Silva Mendes, Sangbo Oh, Cem Onal, Lei Ren, Apurva Singh, Phuoc Tran

Affiliation: University of Maryland School of Medicine, Baskent University Faculty of Medicine, Department of Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: To predict metastasis-free survival (MFS) for patients with prostate adenocarcinoma treated with androgen deprivation therapy and external radiotherapy using clinical factors and radiomics ex...

Quality Assurance Program for Dual Energy Subtraction Imaging-Based Markerless Tumor Tracking

Authors: Hyejoo Kang, Andrew Keeler, Mathias Lehmann, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Varian Imaging Laboratory, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose: Markerless tumor tracking (MTT) using dual-energy (DE) subtraction imaging is being considered as a non-invasive method to track tumors during lung cancer treatment. Prior to clinical impleme...

Quantification of Chemical Species Yield and Radiation Damage Patterns for Radiopharmaceutical Therapy Isotopes: Lu-177, Y-90 and I-131

Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal

Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology

Abstract Preview: Purpose: The fundamental concept of radiopharmaceutical therapy involves binding radioisotopes to molecules with a known biokinetic distribution, which ensures that the targeted organs receive higher ...

Quantifying Cervical Cancer Radiotherapy Care Gap in Uganda: Baseline Assessment Prior to Implementation of a Custom Mobile Health App.

Authors: Eric C. Ford, Awusi Kavuma, Solomon Kibudde, Lilie Lin, Apollo Muramuzi, Nibedita Paul, Peniel T Twum, Afua A. Yorke

Affiliation: Uganda Cancer Institute, MD Anderson Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Nebraska, Global Communities

Abstract Preview: Purpose: Sub-Saharan Africa accounts for over one-third of global cervical cancer deaths, despite representing only 14% of the world’s female population. At the only RT center in Uganda, prior studies...

Recovery Factor Comparisons for Reirradiation Overlapping the Spinal Cord

Authors: Xinxin Deng, Issam M. El Naqa, Jimm Grimm, Lijun Ma, Vitali Moiseenko, Timothy E. Schultheiss, Gopal Subedi, Wolfgang A. Tomé, Ellen D. Yorke, Albert van der Kogel

Affiliation: Montefiore Medical Center, Wellstar Kennestone Hospital Cancer Center, H. Lee Moffitt Cancer Center, Department of Human Oncology, University of Wisconsin–Madison, Department of Radiation Oncology, Wellstar Health System, Radiation Oncology, Keck School of Medicine of USC, Georgia Institute of Technology, University of California San Diego, City Of Hope National Medical Centre, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Reirradiation is increasingly utilized in clinical practice but dose-time recovery factors for human subjects remain uncertain. We constructed a reirradiation recovery model for spinal cord e...

Simulation Design of a Dedicated Head Coil for Enhanced EPT Imaging to Map the Electrical Properties of Tumor Tissues

Authors: Jingyao Chen, Yingli Yang, Jie Zhang

Affiliation: Department of Radiology, Ruijin Hospital, Shanghai Ruijin Hospital, Shanghai United imaging Healthcare Advanced Technology Research Institute

Abstract Preview: Purpose: Magnetic Resonance Electrical Properties Tomography (MR EPT) is a method to spatially mapping the conductivity and permittivity based on small B1 field changes after the imaged object was int...

Streamlining Orthovoltage QA: Feasibility of IC Profiler Dosimetry and Workflow Optimization

Authors: Huixiao Chen, Zhe (Jay) Chen, MinYoung Lee, Sameer Taneja

Affiliation: Yale School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Superficial radiation therapy uses low-energy x-rays to treat various types of cancers, including non-melanoma skin cancers, and dermatological conditions such as keloid scars, mycosis fungoi...

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Testing Experience in Dose Monitoring Solutions: Automation Aberrations in Automated Organ Dose Estimation

Authors: Lawrence T. Dauer, Yusuf Emre Erdi, Yiming Gao, Dustin W. Lynch, Usman Mahmood

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Radiation dose to patients in CT examinations (CTDIvol, DLP) is tracked in dose monitoring solutions. Some solutions push for automatically estimating patient organ doses based on exam images...

The Root Cause of Large Differences in Calculated Beam Monitor Units between a Treatment Planning System and a QA Software

Authors: George X. Ding, Kenneth L. Homann

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: It is standard practice that the beam monitor units (MUs) calculated by a commercial treatment planning system (TPS) is verified by a secondary dose calculation (SDC) software that independen...

The Use of a Milled NIST Traceable Tld for End-to-End Validation in Mlc and Cone SRS Programs.

Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger

Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University

Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...

To Assess and Monitor the Characteristics of Scanning Proton Beam Utilizing the Xrv-124 Scintillator Device

Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag

Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University

Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...

Utilization of Log File Analysis to Determine Deliverability of VMAT Plans As a Function of Plan Complexity

Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager

Affiliation: Northwell

Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...

Validation of 3D Pseudo-Dose Map Reconstructed from Multi-View Cherenkov Images in Total Skin Electron Therapy

Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison

Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

Variations in Automatic Dose Response Curves across Fluoroscope Types and Manufacturers for Abdominal Imaging

Authors: Hadley Anna DeBrosse, Edward J. Stafford, Kevin A. Wunderle

Affiliation: Ohio State University, The Ohio State University

Abstract Preview: Purpose: To investigate automatic dose response curves from fluoroscopes across multiple manufacturers for an abdominal imaging protocol.
Methods: ADRC response for multiple fluoroscopes were evalu...

“See” through Surface: Transforming Surface Imaging into a Real-Time Three-Dimensional Imaging Solution for Intra-Treatment Image Guidance

Authors: Steve B. Jiang, Ruiqi Li, Hua-Chieh Shao, Kenneth Westover, You Zhang, Tingliang Zhuang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose:
Respiratory motion is a long-standing challenge for lung SBRT, particularly for centrally-located lung tumors where increased toxicity demands more precise motion management during treatme...