Search Submissions 🔎

Results for "cone scanner": 76 found

12 Year Clinical Experience with Low-Tesla MRI for Tumor Progression

Authors: Soon N. Huh, Perry B. Johnson, Jiyeon Park, Ryan Stevens

Affiliation: University of Florida Health Proton Therapy Institute, UF Health Proton Therapy Institute, UFHPTI

Abstract Preview: Purpose:
Low-Tesla MRI (0.23T Panorama MR Scanner, Philips) has been used for tumor progression during proton therapy treatments, and for initial contouring in addition to diagnostic MRI. The pulse...

3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A Deformable Registration-Based Pipeline for the Characterisation of Respiratory Motion from 2D Lung Cine MRI

Authors: Michael W. Kissick, Chung Tin Lo, Jamie R McClelland, Niek Schreuder, Tracy Underwood

Affiliation: Hawkes Institute, University College London, Leo Cancer Care

Abstract Preview: Purpose: The emerging field of upright radiotherapy raises the question of how respiratory motion differs between upright and supine treatment postures. Therefore, we have developed a versatile pipeli...

A Dual Energy CT-Guided Intelligent Radiation Therapy Platform

Authors: Jiayi Chen, Manju Liu, Ning Wen, Haoran Zhang, Yibin Zhang

Affiliation: Department of Radiation Oncology, Ruijin Hospital, Department of Radiology, Ruijin Hospital Shanghai Jiaotong University School of Medicine, Duke Kunshan University, Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine

Abstract Preview: Purpose: This study introduces a novel Dual Energy CT (DECT)-Guided Intelligent Radiation Therapy (DEIT) platform designed to streamline and optimize the radiotherapy process. The DEIT system combines...

A Novel Design of Photon-Counting Static Cone-Beam CT System for Dedicated Breast Imaging

Authors: Ahad Ollah Ezzati, Yile Fang, Xiaoyu Hu, Xun Jia, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: With breast cancer being one of the most prevalent cancers, regular screening is an effective strategy to mitigate the risk of malignancy. However, conventional energy-integrating detector (E...

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

A Window-Level Based Approach for Generating Missing Tissue in CT Scans Using a Transformer-Gan Model

Authors: Mojtaba Behzadipour, Siyong Kim, Mitchell Polizzi, Richard R. Wargo, Lulin Yuan

Affiliation: VCU Health - Department of Radiology, Virginia Commonwealth University

Abstract Preview: Purpose:
The purpose of this study is to develop a method for generating missing tissue in CT scans of patients with large body sizes, where the field of view (FOV) of the scanner fails to capture ...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

Achieving Consistent Calcium Score in Lung Cancer Screening: Influence of Cardiac Phases

Authors: Emi Ai Eastman, Chao Guo, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose:
Smoking is one of the risk factors for coronary artery disease. It is desirable to estimate the coronary artery calcification (CAC), a key biomarker for atherosclerosis and cardiovascular ...

An Adaptive Non-Local Means Filtering Method for Denoising CBCT Images Under Low X-Ray Fluence Conditions

Authors: Cem Altunbas, Farhang Bayat

Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic

Abstract Preview: Purpose:
Low dose imaging and scatter rejection hardware in CBCT reduces X-ray fluence incident on the imager, increasing noise, causing photon starvation artifacts in CBCT images. In this work, we...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Artificial Intelligence-Powered Conventional Energy Integrating Detector-Based Coronary CT Angiography: Learning High-Resolution and Multi-Energy Imaging from Photon-Counting Detector CT

Authors: Shaojie Chang, Thomas A. Foley, Hao Gong, Emily Koons, Shuai Leng, Cynthia H. McCollough, Eric E. Williamson

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To enhance coronary CT angiography (cCTA) capabilities on conventional energy integrating detector CT (EID-CT) using artificial intelligence (AI). The AI framework incorporates high-resolutio...

Assessing the Feasibility of LD-V1 Film for Annual Kilovoltage Imaging Dose Measurements

Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

Asymmetrical High Performance Brain Dedicated PET System: Design Optimization and Performance Evaluation

Authors: Yuemeng Feng, Hamid Sabet

Affiliation: Massachusetts General Hospital, Harvard Medical School

Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...

Black Bone MRI As a Surrogate for CT to Detect Intensity Differences in Mandible Sub-Volumes

Authors: Cem Dede, Clifton David Fuller, Renjie He, Laia Humbert Vidan, Stephen Y. Lai, Amy Moreno, Mohamed Naser, Kareem Abdul Wahid, Natalie A West

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Head and neck cancers (HNC) treated with radiation therapy can result in radiation-induced bone injury. In CT, changes in radiodensity correlate to changes in bone integrity. Most studies use...

CT-on-Rails Longitudinal Image Quality Stability for Intensity Modulated Adaptive Proton Therapy

Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao

Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...

Characterization of Commercially-Available Dosimeters and Prototype Diamond Detectors for Absolute Flash Dosimetry of Small-Field Pulsed Proton Beams

Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang

Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Clinical Implementation of Volumetric Modulated Arc Therapy (VMAT) for Total Body Irradiation (TBI) with Off-the-Shelf Tools

Authors: Kai-Cheng Chuang, Oana I. Craciunescu, Christopher Kelsey, Joseph Kowalski, Nicole Larrier, Xinyi Li, Sheridan G. Meltsner, Anna E. Rodrigues, Yang Sheng, Qiuwen Wu

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: To clinically implement a Volumetric Modulated Arc Therapy (VMAT) procedure for Total Body Irradiation (TBI) with off-the-shelf tools.
Methods: Patient is treated on linac couch with a hyb...

Commissioning of a Near Real-Time In Vivo Film Dosimetry System

Authors: Maria F. Chan, Indra J. Das, Xiuxiu He, Seng Boh Gary Lim, Jeonghoon Park, Yunjie Yang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: There is a need for accurate and flexible in-vivo dosimetry systems, particularly for special procedures. Effective dosimetry is crucial for dose verification and maintaining records. A new r...

Comparison of Cine Cardiac Magnetic Resonance (CMR) Imaging Performance: 0.6 T Versus 1.5 T, Is 0.6 T Fit for Purpose?

Authors: Jacinta E. Browne, Tzu Cheng Chao, Ajit Deveraj, Ece Ercan, Tim Leiner, Alessio Perazzolo, Michal Povazan, Jouke Smink, Camilla Vita, Spencer Waddle, Dinghui Wang

Affiliation: Università Cattolica del Sacro Cuore, Philips Healthcare, Mayo Clinic

Abstract Preview: Purpose:
In recent years, mid-field MRI has shown promise to meet the technical demands of cardiac imaging1. Mid-field strengths offer advantages to CMR due to shorter T1-relaxation times, lower sp...

Comprehensive Assessment of a Large Field of View Phantom for Routine MR Image Quality on a 1.5T Mrgrt System

Authors: Krystal M. Kirby, Aliasghar Rohani, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, Louisiana State University, Baton Rouge, Louisiana

Abstract Preview: Purpose: Accurate treatment delivery in MR-guided radiotherapy (MRgRT) systems requires consistent imaging quality assurance (QA) to assess MR image quality. However, standard QA phantoms have limited...

Contrast Volume Prediction Using CT Dose Metrics

Authors: Niki Fitousi, Anna Romanyukha, Stuart Utting

Affiliation: University Hospitals Dorset, Qaelum NV

Abstract Preview: Purpose:
For increased patient safety and with a focus on sustainability in the radiology department, efforts are being made to optimize contrast media usage. In this study, the possibility of util...

Cross-Calibration and Comparison of CT Number to Electron Density Using Two Calibration Phantoms

Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...

Cross-Calibration of CT Number to Electron and Physical Density: Feasibility of Using Diagnostic Scans for Treatment Planning

Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...

Decreasing the Dependence of CT Number on the Position in the Field-of-View Using Photon Counting Detector CT

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: The dependence of CT number on position in the field-of-view (FOV) imposes challenges in radiotherapy treatment planning. This study aims to decrease this dependence using photon counting det...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Design and Testing of a Portable Microwave Scanner for Imaging Soft Tissue and Tumors in Cancer Patients

Authors: Imad M. Ali, Nesreen Alsbou, Sakeeneh Majeed

Affiliation: University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: to design and assess a microwave imaging system equipped with multiple antennas for generating high-resolution 3D images of phantom models that simulate abdominal, thoracic, and brain tissues...

Design and Use of a Modified Commercial Phantom for Gamma Knife End-to-End Testing

Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad

Affiliation: Roswell Park Comprehensive Cancer Center

Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...

Development and Clinical Validation of an Analytical Approach for 3D Positron Emitter Distribution Prediction in Carbon Ion Therapy

Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...

Development of a Novel Deformable Pelvis Phantom to Support Upright Applications

Authors: Adam P. Berdusco, Matthew R. Ceelen, Renata Farrell, Carri K. Glide-Hurst, Will Martin, Charles F. Maysack-Landry, Morgan A. McGauley, James Rice, Jordan M. Slagowski, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Upright radiotherapy (RT) is now available although this novel vertical CT and positioner presents unique challenges for quality assurance and testing methodologies. We have designed and buil...

Development of a Physical Phantom for Assessing Tube Current Modulation in CT Imaging

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Laura Dinwiddie, Benjamin Taylor Heggie, Adam Leon Kesner, Juan Camilo Ocampo Ramos, Graham Joseph Stoddard

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: The objective of this study is to develop a physical phantom to quantify tube current modulation (TCM) and assess the limitations of a TCM model used in Monte Carlo patient CT organ dose esti...

Dose Distribution Analysis for Different Geometries of a Multiple-X-Ray Source Array (MXA) CT Scanner

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A Multiple-X-ray Source Array (MXA) for CT (MXA-CT) is under development to mitigate cone beam artifacts in axial CT scans using wide collimation. The purpose of this study is to assess the i...

Dose Mapping of Radioactive Gold Nanoparticles Using Three-Dimensional Dosimetry

Authors: Ana Laura Burin, Maysa Müller Ferreira Gesserame, David Alexander Urbina Leal, Ilca Marli Moitinho Amaral Medeiros, Silas Leonel Pereira Miranda, Thuany Corrêa Nogueira, Maria da Penha Alburquerque Potiens, Pedro Henrique Ricardo, Maria Eduarda Zaganin Rigo, Orlando Rodrigues, Priscila Santos Rodrigues, Wilmmer Alexander Arcos Rosero, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Ana Catarina Koka de Souza Silva, Cristhian Ferreira Talacimon, Paulo Victor dos Santos Tavares, Lara El Hajj Teodoro, Carlos Alberto Zeituni, José Neres de Almeida

Affiliation: IPEN - USP

Abstract Preview: Purpose: Perform three-dimensional dosimetry of radioactive gold nanoparticles (¹⁹⁸AuNPs) using Fricke xylenol gel (FXG), aiming to determine the dose distribution and evaluate the method's effectiven...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Contrast and Chromaticity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists have traditionally supported radiation-based medicine, but their expertise can translate to other image-based fields including pathology. As pathology transitions to digita...

Ensuring Consistency in Digital Pathology: Medical Physics Approaches to Comparison of Scanner Sharpness and Artifact Severity

Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Medical physicists traditionally support radiation-based medicine, but their expertise is translatable to image-based fields like pathology. As pathology transitions to digital practices, phy...

Establishing a Protocol for Quality Assessment of Ultrasound Shear Wave Elastography (SWE) and Application to a Musculoskeletal (MSK) Task

Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...

Evaluation of the Reflexion X1 As a Standalone PET/CT Simulator for Treatment Planning and Treatment Adaptation

Authors: Chunhui Han, An Liu, William T. Watkins, Qiuyun Xu

Affiliation: Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the RefleXion X1 imaging system as a standalone positron emission tomography and computed tomography (PET/CT) simulator for radiotherapy treatment planning and adaptive re-plannin...

Evaluation of the Varian Truebeam Linac Matching Process: Before, during, and after the Commission

Authors: Edwin Quashie, Yun Wang

Affiliation: Indiana University Medical School, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: To provide a formal evaluation for the TrueBeam linac matching process before, during and after the commission of the newly installed TrueBeam linac which we want to match to an existing True...

Extremity Imaging with Cone-Beam CT (CBCT) Scanner Dedicated for Hip Imaging – What Are the Effective Doses?

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...

Film-Based Method for Accurate Radiation Isocenter Determination in Linear Accelerators Using 3D Starshot

Authors: Robert A. Corns, Mohammad Kanber

Affiliation: East Carolina University, East Carolina University Brody School of Medicine

Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...

First In Vivo Proton Beam Irradiation of Mice with Quasi-Real-Time Range Verification with the Sirmio PET Scanner

Authors: Niels Bassler, Jonathan Bortfeldt, Francesco Evangelista, Giulio Lovatti, Jasper Nijkamp, Rasmus Nilsson, Munetaka Nitta, Katia Parodi, Marco Pinto, Per R. Poulsen, Brita Singers Sørensen, Peter Thirolf, Erik Traneus, Taiga Yamaya

Affiliation: RaySearch Laboratories AB, National Institutes for Quantum Science and Technology, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: Within the SIRMIO project (Small Animal Proton Irradiator for Research in Molecular Image-Guided Radiation Oncology), we aimed to perform the first in vivo proton beam treatment with a dedica...

Geometric Alignment of MV-CBCT and Dual-Layer Kv-CBCT Projections Using Deep Learning

Authors: Ross I. Berbeco, Vera Birrer, Raphael Bruegger, Pablo Corral Arroyo, Roshanak Etemadpour, Dianne M. Ferguson, Rony Fueglistaller, Thomas C. Harris, Yue-Houng Hu, Matthew W. Jacobson, Mathias Lehmann, Nicholas Lowther, Daniel Morf, Marios Myronakis

Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, Dana Farber/Brigham and Women's Cancer Center, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Womens Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Varian Imaging Laboratory, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Applications of combined kV-MV CBCT include metal artifact correction and material identification. Difficulties arise, however, when the imagers have misaligned geometric perspectives of the ...

High Resolution Head Motion Correction Based on Pilot Tone Signals – a Calibration-Free Method

Authors: Cheng-Chieh Cheng, Jeffrey P Guenette, Yajun Li, Bruno Madore, Lei Qin

Affiliation: Brigham and Women's Hospital, National Sun Yat-sen University, Dana-Farber Cancer Institute

Abstract Preview: Purpose: Pilot tone (PT), a compact RF sensor, has been integrated into clinical practice for motion detection. Prior studies proposed mapping PT signals to head positions using a calibration step tha...

Image-Guided Adaptive Proton Therapy for Head and Neck Cancer Using a Novel Gantry-Less System

Authors: Philip Blumenfeld, Jon Feldman, Yair Hillman, Michael Marash, Aron Popovtzer, Alexander Pryanichnikov, Shimshon Winograd, Marc Wygoda, Vered Zivan

Affiliation: Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT), P-Cure Ltd./Inc., Sharett Institute of Oncology, Hadassah Medical Center, Hebrew University of Jerusalem

Abstract Preview: Purpose:
Image-guided adaptive proton therapy (IGAPT) allows tailored dose adjustments to account for anatomical and physiological changes during treatment. Recent efforts have developed a cost-eff...

Imaging of Mn Washout in the Individual Welder Brain after Wearing Powered Air-Purifying Respirators (PAPRs)

Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park

Affiliation: Purdue University

Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...

Impact of Jaw Reproducibility and Source Occlusion on Small Field Dosimetry

Authors: Mylinh Dang, Indra J. Das, George X. Ding, Ahtesham Ullah U Khan, Andrew J. White

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine, Northwestern Medicine, Vanderbilt University Medical Center

Abstract Preview: Purpose: The large variability in field output factor (FOF) observed among various studies is speculated to be due to uncertainty in jaw reproducibility that is linked directly with source occlusion. ...

In silico Evaluation Vs Standard Phantom Evaluation of a Deep Learning Reconstruction Algorithm

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Dylan Mather, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate the performance a deep learning reconstruction (DLR) algorithm in an anatomical background compared to a uniform phantom background.
Methods: An analytic forward projection mod...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Investigation of Low Iodine Concentration Detectability of Dual-Energy CT Imaging Using a Customized 3D Printed Phantom

Authors: Michalis Aristophanous, Laura I. Cervino, Maria F. Chan, Puneeth Iyengar, Hsiang-Chi Kuo, Nancy Y Lee, Xiang Li, Seng Boh Gary Lim, Usman Mahmood, Jean M. Moran, Jason Ocana

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To determine the limits of iodine concentration detection (LOD) and quantification (LOQ) in dual-energy computed tomography using a 3D printed phantom while considering different background, ...

Lung-Equivalent Compressible Material As Core Component for a Miniaturized Breathing Phantom Prototype

Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe

Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences “Mario Serio”, University of Florence

Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...

Matching CT Numbers between a Photon-Counting CT and an Energy-Integrating Detector CT: A Phantom Study

Authors: Afrouz Ataei, Xinhui Duan, Mi-Ae Park, Liqiang Ren

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University

Abstract Preview: Purpose:
Photon-counting CT (PCCT) has become commercially available recently, offering significant potential to enhance patient care. However, it also introduces unique challenges. One such challe...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Multiple x-Ray Source Array (MXA) System Development for Better Ray Sampling in Large Coverage Axial CT Imaging

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Sarah E. McKenney, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose:
While wide coverage (160 mm) CT scanners can image whole organs (e.g. heart, brain, kidneys, etc.) in one axial scan, the peripheral regions of the field of view (along z) suffer from cons...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

On Estimating Effective Doses Associated with Different Imaging Protocols for Weight-Bearing Imaging of the Hip with a Dedicated Cone Beam CT (CBCT) Scanner

Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna

Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI

Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Quantitative Analysis of Three Strategies for CTPA Scan Timing Optimization

Authors: Zahra Alyani Nezhad, Carrie Bartels, Rachel Bladorn, Sean D. Rose, Kelsey Schluter, Timothy P. Szczykutowicz

Affiliation: Departments of Radiology and Medical Physics, University Wisconsin-Madison, University of Wisconsin Madison, University of Wisconsin-Madison, University of Texas at Houston Medical School, University of Wisonsin-Madison

Abstract Preview: Purpose: Pulmonary embolism is a life-threatening condition, and computed tomography pulmonary angiography (CTPA) is the gold standard for diagnosis. Inadequate contrast enhancement often leads to a h...

Role of Medical Physicists in CT Contrast Optimization: A Case Study

Authors: Zahra Alyani Nezhad, Carrie Bartels, Rachel Bladorn, Sean D. Rose, Kelsey Schluter, Timothy P. Szczykutowicz

Affiliation: Departments of Radiology and Medical Physics, University Wisconsin-Madison, University of Wisconsin Madison, University of Wisconsin-Madison, University of Texas at Houston Medical School, University of Wisonsin-Madison

Abstract Preview: Purpose: This study presents a scientifically quantified case study that underscores the importance of the medical physicist’s contribution to contrast enhancement optimization.
Methods: CT pulmona...

Sources of Variability in Evaluating Ultrasound Imaging Performance Using Randomly-Distributed Hypoechoic Sphere Phantom

Authors: Cristel Baiu, Zheng Feng Lu, Dufan Wu, Baihui Yu

Affiliation: University of Wisconsin, Massachusetts General Hospital, University of Chicago

Abstract Preview: Purpose: IEC TS 62791:2022 specified a clinically meaningful and quantitative framework for evaluating diagnostic ultrasound performance by measuring the lesion signal-to-noise ratio (LSNR) using rand...

Spectral CT Assessment of 3D Printing Techniques for Improving the Uniformity and Reproducibility of Models Applied in Medical Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...

Support for Radiotherapy in Ukraine: Help Ukraine Group Activities and the Importance of International Collaboration

Authors: Serhii Brovchuk, Viktor M. Iakovenko, Nataliya Kovalchuk, Yuliia Lozko, Zoia Shepil, Natalka Suchowerska, Ruslan Zelinskyi

Affiliation: Kyiv Regional Oncology Dispensary, Stanford University, O.O. Shalimov National Institute of Surgery and Transplantology, School of Physics, The University of Sydney, Medical Physics Department, Medical center of Yuriy Spizhenko, Department of Radiation Oncology, UT Southwestern Medical Center, Stanford Cancer Center

Abstract Preview: Purpose: The full-scale russian invasion of Ukraine has caused the largest humanitarian disaster in Europe since World War II. This study identifies gaps in RT services caused by the war and outlines ...

Task Specific Image Quality Assessment Using Spectral Photon-Counting CT.

Authors: Azza Mohamed Ahmed, Nadine Francis, Osama Khan, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: The study aims to evaluate the task-specific diagnostic performance of spectral photon-counting CT (SPCCT) using application-specific phantoms.
Methods:
Parameters such as linearity res...

Testing Experience in Dose Monitoring Solutions: Automation Aberrations in Automated Organ Dose Estimation

Authors: Lawrence T. Dauer, Yusuf Emre Erdi, Yiming Gao, Dustin W. Lynch, Usman Mahmood

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Radiation dose to patients in CT examinations (CTDIvol, DLP) is tracked in dose monitoring solutions. Some solutions push for automatically estimating patient organ doses based on exam images...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

To Establish Local Diagnostic Reference Levels (DRLs) for Head and Neck Computed Tomography (CT) Exams in Abuja, Nigeria, and to Investigate the Performance of Brain Metastasis (BM) and Brain Lesion (BL) Segmentation Techniques Using U-Net Models.

Authors: Nuraddeen Nasiru Garba, Kalpana M Kanal, Abdullahi Mohammed, Rabiu Nasiru, Muhammad SHAFIU Shehu, Daniel Vergara, Joseph Everett Wishart

Affiliation: AHMADU BELLO UNIVERSITY, ZARIA, University of Washington

Abstract Preview: Purpose: To establish local Diagnostic Reference Levels (DRLs) for head and neck computed tomography (CT) exams in Abuja, Nigeria, and to investigate the performance of brain metastasis (BM) and brain...

Towards Achieving Quantitative Attenuation Values in CT with Energy-Integrated and Photon-Counting Detectors

Authors: Zijia Guo, Viktor Haase, Michael F. McNitt-Gray, Frederic Noo

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: The attenuation values in CT hold strong potential for disease diagnosis. However, they lack reliability, which has limited their use to clinical trials where variability can be controlled. S...

Tumor Density on Time-Weighted Mid-Position Images for Thoracic Tumors

Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...

Validating a Pre-Existing CT HU-to-Mass Density Curve for Direct Dose Calculation on High Quality Cbcts

Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray

Affiliation: University of California San Diego

Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...

Validation of a Simulation Tool and in-Silico Assessment of Low Contrast Detectability for Super-Resolution Deep Learning Reconstruction

Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin

Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA

Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...

Validation of an Open Source Automatic Segmentation Tool for Personalized Dosimetry

Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie

Affiliation: Ghent University

Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...

Variations in Radiation Isocenter Offsets from the Winston-Lutz Test Performed on Different Photon Energies

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...