Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu
Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...
Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz
Affiliation: UT Health San Antonio
Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...
Authors: Hao Gao, Xue Hong, Harold Li, Yuting Lin, Jufri Setianegara, Xin Tong, Chao Wang, Weijie Zhang, Ya-Nan Zhu
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high radiation doses to specific tumor regions (vertices) while sparing surroun...
Authors: Shahed Badiyan, Tsuicheng D. Chiu, Viktor M. Iakovenko, Steve Jiang, Christopher Kabat, Mu-Han Lin, Roberto Pellegrini, Arnold Pompos, Edoardo Salmeri, David Sher, Sruthi Sivabhaskar, Justin D. Visak
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Global Clinical Science, Elekta AB, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Adaptive treatment planning requires robust strategies to enable streamlined on-couch processes, creating a significant barrier for planners transitioning from conventional to adaptive planni...
Authors: Muhammad Ramish Ashraf, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner
Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Precise beam collimation is essential in preclinical radiotherapy studies to ensure accurate dose delivery. Manual design and fabrication of organ-specific collimators usually consist of mult...
Authors: Hongyi Jiang, Fang-Fang Yin
Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...
Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang
Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment
Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...
Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright
Affiliation: UC Davis Cancer Center
Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Qianyi Xu, Inhwan Yeo
Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University
Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...
Authors: Ning Cao, Sunan Cui, Danielle P. Johnson Erickson, Juergen Meyer, Ramesh Rengan, Ben A Shaver, Jing Zeng
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington and Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: To investigate the immune response in primary irradiated tumors and non-irradiated tumors in a mouse melanoma xenograft model, comparing 18Gy of conventional (CONV) and ultra-high dose rate (...
Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...
Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...
Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu
Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health
Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...
Authors: Timothy J Allen, Clara Ferreira
Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis
Abstract Preview: Purpose: Presurgical treatment planning for GammaTile cranial implants is limited to estimates of required tiles and provides no positioning information. Existing tools are intended for tile estimatio...
Authors: Lu Jiang, Ke Sheng
Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Conventional radiotherapy treatment planning is guided by a set of generic objectives that are unspecific to patient anatomy. Treatment planning thus heavily relies on the plannerβs experi...
Authors: Ming Dong, Carri K. Glide-Hurst, Behzad Hejrati, Joshua Pan, Yuhao Yan
Affiliation: Department of Computer Science, Wayne State University, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Upright patient positioners and vertical CT reduce tumor motion and stabilize internal anatomy during treatment delivery. Yet, to fully exploit the advantages of upright, translation of stand...