Search Submissions πŸ”Ž

Results for "conventional shaped": 17 found

A Novel Semi-Analytic Approach for Dose Calculation in Proton Minibeam Radiotherapy

Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...

A Surface-Conforming Flexible Collimator for Improving Electron Radiotherapy

Authors: Neil A. Kirby, Parker New, Niko Papanikolaou, Holly Paschal, Karl H. Rasmussen, Daniel L. Saenz

Affiliation: UT Health San Antonio

Abstract Preview: Purpose: To simplify the traditional method of patient-specific skin collimation and improve the precision of electron radiotherapy treatment with a new surface conforming collimation system.
Metho...

An Integrated Optimization Method for Joint Lattice Positioning and Dose Planning in Lattice Therapy

Authors: Hao Gao, Xue Hong, Harold Li, Yuting Lin, Jufri Setianegara, Xin Tong, Chao Wang, Weijie Zhang, Ya-Nan Zhu

Affiliation: Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high radiation doses to specific tumor regions (vertices) while sparing surroun...

Assessment of Automated Planning Templates for Genitourinary and Gastrointestinal Disease Sites for Online MR-Guided Adaptive Radiotherapy

Authors: Shahed Badiyan, Tsuicheng D. Chiu, Viktor M. Iakovenko, Steve Jiang, Christopher Kabat, Mu-Han Lin, Roberto Pellegrini, Arnold Pompos, Edoardo Salmeri, David Sher, Sruthi Sivabhaskar, Justin D. Visak

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Global Clinical Science, Elekta AB, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Adaptive treatment planning requires robust strategies to enable streamlined on-couch processes, creating a significant barrier for planners transitioning from conventional to adaptive planni...

Automated Parametric Custom Collimator Creation for Preclinical Irradiation Studies

Authors: Muhammad Ramish Ashraf, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Precise beam collimation is essential in preclinical radiotherapy studies to ensure accurate dose delivery. Manual design and fabrication of organ-specific collimators usually consist of mult...

Automatic 4D Lung PET-CT Segmentation Using Hybrid Deep Neural Network

Authors: Hongyi Jiang, Fang-Fang Yin

Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...

Characterization of a Novel Large-Sized Epid System from the Newly Released Ring Shape Radiation Therapy Halos Tx

Authors: Sen Bai, Guyu Dai, Dong Gao, Lecheng Jia, Guangjun Li, Yanfang Liu, Ying Song, Qing Xiao, Wei Zhang

Affiliation: United Imaging Healthcare, West China Hospital of Sichuan University, Shenzhen United Imaging Research Institute of Innovative Medical Equipment

Abstract Preview: Purpose:
Electronic portal imaging device (EPID) is currently the most widely used in-vivo dosimetry (IVD) device. However, the effective detector area shortage hinders further applications. This s...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Feasibility of Zap-X Beam Quality Assurance Using Cherenkov Radiation

Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao

Affiliation: University of Miami

Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Immune Response on Ultra-High Dose Rate (FLASH) and Conventional Proton Radiation in a Mouse Xenograft Model

Authors: Ning Cao, Sunan Cui, Danielle P. Johnson Erickson, Juergen Meyer, Ramesh Rengan, Ben A Shaver, Jing Zeng

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington and Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: To investigate the immune response in primary irradiated tumors and non-irradiated tumors in a mouse melanoma xenograft model, comparing 18Gy of conventional (CONV) and ultra-high dose rate (...

Mid-Range Planning for Efficient and Robust Proton Arc Therapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...

Monte Carlo Simulation of Surface Radiation Dose for Cherenkov Imaging: Comparison with Commissioning Data for Truebeam and Halcyon

Authors: Hongjing Sun, Weibing Yang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to compare the commissioning results of TrueBeam and Halcyon linear accelerators with Monte Carlo (MC) simulations conducted using TOPAS. The ultimate goal is to leverage MC s...

Preliminary Clinical Experience with MRI-Guided Online Adaptive Radiotherapy for Esophageal Cancer Patients

Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu

Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health

Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...

Presurgical Treatment Planning for Gammatile Implants

Authors: Timothy J Allen, Clara Ferreira

Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis

Abstract Preview: Purpose: Presurgical treatment planning for GammaTile cranial implants is limited to estimates of required tiles and provides no positioning information. Existing tools are intended for tile estimatio...

Ukan Architecture for Voxel-Level Dose Prediction in Radiotherapy

Authors: Lu Jiang, Ke Sheng

Affiliation: Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Conventional radiotherapy treatment planning is guided by a set of generic objectives that are unspecific to patient anatomy. Treatment planning thus heavily relies on the planner’s experi...

Uprightvision: A Deep-Learning Toolkit for Transforming Supine Anatomy to Upright

Authors: Ming Dong, Carri K. Glide-Hurst, Behzad Hejrati, Joshua Pan, Yuhao Yan

Affiliation: Department of Computer Science, Wayne State University, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Upright patient positioners and vertical CT reduce tumor motion and stabilize internal anatomy during treatment delivery. Yet, to fully exploit the advantages of upright, translation of stand...