Search Submissions 🔎

Results for "couch rotation": 18 found

A Pilot Study to Implement a Definitive Breast SBRT Technique

Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal

Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre

Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...

Combining Flat-Panel Imaging and Internal BB Markers for Precise HDR Brachytherapy Source Localization

Authors: Yibin Ling, Qihui Lyu, Ke Sheng

Affiliation: University of California Berkeley, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
High Dose Rate (HDR) brachytherapy enables radiation to concentrate on the tumor by sending the high-dose-rate radioactive source directly to the treatment site. On the other hand, the sha...

Comparison of the Sun Nuclear Multi-Met Winston Lutz Test and Varian's Machine Performance Check for Isocenter Alignment for Rotational Accuracy

Authors: Junsheng Cao, Luis A. Maduro Bustos, Khushdeep Singh

Affiliation: Overlook Medical Center, Atlantic Health System at Morristown Medical Center

Abstract Preview: Purpose: To evaluate the agreement between the Sun Nuclear Multi-Met Winston Lutz test (WL) and Varian’s Machine Performance Check (MPC) in assessing isocenter alignment, couch, and collimator rotatio...

Design and Testing of a 3D-Winston-Lutz Phantom to Quantify Isocentricity of Pencil Beam Scanning Proton Therapy Machines

Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani

Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...

Direct Table Rotational Isocenter Determination Using Radiation Isocenter

Authors: Christopher Ackerman, Chang Chang, Yansong Liu, Stephen Kenneth Northway, Bailey Vallejo

Affiliation: University of California San Diego / California Protons, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center

Abstract Preview: Purpose: To determine mechanical isocenter of a 6-degree-of-freedom (6DOF) couch using radiation isocenter. Coincidence between the isocenters is quantified using MyQA Phoenix amorphous silicon detect...

Dosimetric Impact of Target Coverage with Inter-Fraction Patient Yaw Setup Error in IMRT/VMAT Prostate Cancer Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...

Dosimetric Impact on Patient Roll/Yaw Change for Whole Breast 3D Radiotherapy

Authors: Min Su

Affiliation: Mount Sinai School of Medicine

Abstract Preview: Purpose: To evaluate dosimetric impact of target coverage and organ at risk (OARs) sparing for whole breast patient setup roll/yaw change in 3D-conformal radiotherapy.
Methods: 8 whole breast cases...

Dynamic Angular Couch Kinematics in Radiotherapy

Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health

Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Evaluating the Aktina Isopoint System for Quality Assurance in Linear Accelerators

Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...

Evaluation of the Isopoint System for Coincidence of Radiation and Physical Isocenter Checks of Linear Accelerators

Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos

Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...

Investigation of the Correlation between Proton Linear Energy Transfer and Treatment Field Hinge Angles in Brain Tumor Patients Treated with Intensity Modulated Proton Therapy

Authors: Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Minesh P. Mehta, Andrew J. Wroe, Jen Yu

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose: Linear energy transfer (LET) is directly related to relative-biological-effectiveness dose in proton therapy. This study aims to investigate how the treatment field hinge angles affect LET of...

Multi-Vendor Linac Isocenter Evaluation: Implications for SRS in Radiotherapy

Authors: Blessing Chinelo Akah, Brad Barhorst, Daniel W. Neck, David J. Perrin, Chad Robertson, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: To evaluate the performance and radiation isocenter of Elekta and Varian linear accelerator using Aktina Isopoint.
Methods: The Aktina Isopoint was used to measure the physical and radiati...

Objective Verification of Mechanical and Radiation Isocenters Independent of Setup

Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy

Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.

Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...

Optimizing Phantom Measurement of Simt Radiosurgery

Authors: Mark W. Geurts, Bridget Ann Melke

Affiliation: Aspirus Health

Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...

Proposed Method for Optimization of Lattice Radiation Therapy Using an Advanced Ring Gantry Linac

Authors: Eduardo Florian, Osmar Obdulio Hernandez, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Edgar Aparicio Ruiz, Kevin Vega, Vicky de Falla

Affiliation: Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Liga Nacional Contra el Cáncer / INCAN

Abstract Preview: Introduccion:
Lattice Radiation Therapy (LRT) is a form of spatially fractionated radiation therapy (SFRT) designed to improve control of large tumors by delivering ablative doses while minimizing ...

Surface Mapping of Couch Kick Cherenkov Images for Rotation-Independent Treatment Verification in External Beam Radiotherapy

Authors: Petr Bruza, Alexander Geiersbach, David J. Gladstone, Lesley A Jarvis, Allison Matous

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health

Abstract Preview: Purpose: During external beam radiation therapy, couch kicks are often necessary to achieve effective treatments, yet they make interpreting Cherenkov images much more challenging. We present a surfac...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...