Search Submissions 🔎

Results for "cumulative doses": 31 found

AI-Assisted Algorithm to Generate Patient Postures for Tset Dose Evaluation

Authors: Kostas Danniidis, Agelos Kratimenos, Yufu Wang, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to develop software and algorithms utilizing artificial intelligence (AI) to seamlessly create 3D patient postures during Total Skin Electron Therapy (TSET). The resulting mes...

An OAR Margin Recipe Based on Clinical Data and Including Radio-Sensitivity Variation

Authors: Carlo Greco, Joep Stroom, Sandra Vieira

Affiliation: Champalimaud Center for the Unknown

Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...

Assessment of Viscoelastic Changes in Ex Vivo Liver Tissue Using Pulsed Magnetomotive Ultrasound during Magnetic Hyperthermia

Authors: David Alejandro Collazos Burbano, Antonio Adilton Oliveira Carneiro, Paul L. Carson, Jose Eduardo Freire, Theo Zeferino Pavan, Joao Henrique Uliana, Nicholas Zufelato

Affiliation: University of São Paulo, University of Michigan, University of Sao Paulo

Abstract Preview: Purpose: Develop a theranostic platform that integrates magnetic hyperthermia (MH), ultrasound, and magnetic nanoparticles (MNPs) to improve diagnosis, treatment, and monitoring of hyperthermia proced...

CBCT Dose Measurement for Common Protocols on Elekta Versahd and Varian Truebeam

Authors: Yingxuan Chen, Jun Li, Alexis N. Webb

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...

Calorimetric Measurement of Absorbed Dose By a Flash Beamline

Authors: Luke Connell, Stephen F. Kry, Malcolm R. McEwen, Bryan R. Muir, James Renaud, Emil Schueler, Hayden Scott, Paige A. Taylor

Affiliation: National Research Council, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To demonstrate the capability of a robust calorimeter to accurately determine the absorbed dose delivered by an electron FLASH beamline.

Methods: Electron FLASH beams of 6 MeV and 9 Me...

Characterization, Commissioning, and Clinical Evaluation of a Commercial Beo Optically Stimulated Luminescence (OSL) System

Authors: Brett G Erickson, Joseph P. Kowalski, Xinyi Li, Qiuwen Wu, Sua Yoo

Affiliation: Duke University, Mayo Clinic - Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: Characterization and commissioning of the BeO-based myOSLchip system was performed (per TG191) to assess its feasibility as a full replacement for the recalled Landauer aluminum oxide OSL in ...

Cherenkov Image Denoising with Diffusion-Based Deep-Learning for High-Fidelity Video Display of EBRT

Authors: Petr Bruza, Jeremy Eric Hallett, Brian W Pogue, Yucheng Tang, Shiru Wang

Affiliation: NVIDIA Corp, Dartmouth College, Thayer School of Engineering, Dartmouth College, University of Wisconsin-Madison, University of Wisconsin - Madison

Abstract Preview: Purpose: Cherenkov imaging allows for real-time visualization of megavoltage X-ray or electron beam delivery during radiation therapy. By using a time-gated intensified CMOS camera synchronized with a...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Development of a Comprehensive Thoracic Re-Irradiation Database and Investigation of Time-Dependent Dose-Recovery Dynamics for Toxicity Modeling

Authors: Victoria Doss, Tsion Gebre, Rachel B. Ger, Esi A Hagan, Elaina Hales, Russell K Hales, Xun Jia, Heng Li, Dezhi Liu, Todd R. McNutt, Meti Negassa, Anas Obaideen, Tinker Trent, K. Ranh Voong, Cecilia FPM de Sousa

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: As cancer care advances, more patients require re-irradiation, yet evidence-based data is lacking. This study aimed to develop a thoracic re-irradiation database and explore time-dependent re...

Dynamic 2.5D Surface Dosimetry Using Deformable Scintillator Array Imaging

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang

Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri

Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of Lead Glasses Efficiency in Reducing Eye Radiation Exposure during Angiography Using Optically Stimulated Luminescence Dosimeters

Authors: Yu-Ying Lin, Yu Chen Shen

Affiliation: Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou

Abstract Preview: Purpose: This study evaluates the protective efficiency of lead glasses against radiation exposure to the eyes during angiography using optically stimulated luminescence dosimeters (OSLDs).
Methods...

Evaluation of the Accumulated Dose in Combined Radiotherapy for Cervical Carcinoma Using DVH Addition and Deformable Image Registration Based on Optimization of BT Boost Region in EBRT

Authors: Qiu Tang, Yeqiang Tu, Jiahao Wang, Lu Wang

Affiliation: Women's Hospital School of Medicine Zhejiang University, Hangzhou Women's Hospital

Abstract Preview: Purpose: The BT boost regions were previously delineated and optimized during EBRT planning process. The differences of DVH parameters addition (PA), deformable dose summation (DS) with BT boost regio...

Fetal Radiation Exposure Monitoring of Pregnant Employees across Multiple Departments and Areas in a Hospital

Authors: Janet Ching-Mei Feng, Janet Gutierrez, Aylin Ozus, Patricia Svolos

Affiliation: Bellaire High, McGovern Medical School, University of Texas Health Science Center at Houston, Environmental Health & Safety, University of Texas Health Science Center at Houston, UTHealth McGovern Medical School

Abstract Preview: Purpose: Exposure to radiation may become harmful to the fetus depending on the gestational age and absorbed dose. The Nuclear Regulatory Commission states the radiation exposure to the embryo/fetus o...

GPU Accelerated Monte Carlo Simulation for Tset Dose Calculation

Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...

Hypersight® Offline Adaptive Workflow

Authors: Doris Dimitriadis/Dimitriadou, Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Noor Mail, Adam Olson, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, UPMC

Abstract Preview: Purpose: The goal of the HyperSight® offline adaptive-workflow is to create a methodical approach to adaptive-radiotherapy (ART) that considers modifications in patient setup and anatomy. Through effi...

Image Quality Enhancement for Transrectal Ultrasound Imaging of Prostate Brachytherapy Using Deep Learning: A Needle Eraser

Authors: Hilary P Bagshaw, Mark K Buyyounouski, Serdar Charyyev, Xianjin Dai, PhD, Yu Gao, Thomas R. Niedermayr, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: Real-time transrectal ultrasound imaging is the gold standard for needle placement and treatment planning of real-time based-ultrasound-based high dose-rate (HDR) prostate brachytherapy. Cumu...

International Survey of Electronic Medical Device Management in Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Electronic medical devices (EMDs) must be carefully managed in radiation oncology to prevent radiation-induced device malfunction. Only one EMD, pacemaker/defibrillator, has a recommended pro...

Introducing an Equieffective 3D Dose Visualization Tool for Reirradiation Special Medical Physics Consults

Authors: James Irrer, Charles K. Matrosic, Martha M. Matuszak, Charles S. Mayo, Kelly C. Paradis, Joann I. Prisciandaro, Benjamin S. Rosen, John Yao, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: To introduce an in-house developed tool, BioDoseUI, designed to calculate and visualize 3D equieffective dose (EQD2Gy) for treatment planning systems (TPS) without such capabilities, to facil...

Investigation of High Cumulative Doses and Dose Outliers in a Pediatric Hospital

Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha

Affiliation: Qaelum NV, Children's National Hospital

Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our “ped...

Monte Carlo Simulation and Dosimetric Verification of 3D Range Modulators for a Multi-Field-Optimization Flash-IMPT Plan

Authors: Michael M Folkerts, Miriam Krieger, Pierre Lansonneur, Gerard Paquet, Petar Penchev, Christoph Schuy, Yuri Simeonov, Uli Weber, Klemens Zink

Affiliation: GSI Helmholtzzentrum fuer Schwerionenforschung, Institute of Medical Physics and Radiation Protection (IMPS), University of Applied Sciences, Varian Medical Systems

Abstract Preview: Purpose:
Ultra-high dose-rate proton irradiation may spare the healthy tissue (FLASH-effect). The 3D-range-modulator (3D-RM) method reduces the treatment time compared to conventional IMPT and can ...

Patient-Specific Deep Reinforcement Learning Framework for Automatic Replanning in Proton Therapy for Head-and-Neck Cancer

Authors: Malvern Madondo, Mark McDonald, Zhen Tian, Christopher Valdes, Ralph Weichselbaum, Xiaofeng Yang, David Yu, Jun Zhou

Affiliation: Department of Radiation & Cellular Oncology, University of Chicago, University of Chicago, Emory University, Department of Radiology, University of Chicago, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Head-and-neck (HN) cancer patients often experience significant anatomical changes during treatment course. Proton therapy, particularly intensity-modulated proton therapy (IMPT), is sensitiv...

Preplanning Physics Consultation with Voxelized EQD2: A Proactive Approach for Streamlined Dose Management in High-Risk Re-Irradiation Patients

Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...

Prostate SBRT Motion Study and PTV Margin Evaluation with Exactrac Fiducial Tracking

Authors: Ahmad K. Al-Basheer, Andrew Clarke Grice, Kelly E. Hosier, Mark Logsdon, Evan A. Silverstein, Chris Tunnicliff, Chuan Wu

Affiliation: Sutter Medical Foundation, Sutter Health

Abstract Preview: Purpose: For Prostate SBRT Boost treatments, determine whether a uniform 2mm CTV to PTV margin is sufficient to give 95% dose coverage to the CTV in 90% of patients via a modified Van Herk Margin Form...

Putting the Gram in Esophagram: A New Metric for Harmonizing Fluoroscopy Doses

Authors: Brendon J. Villegas

Affiliation: University of Alabama Birmingham

Abstract Preview: Purpose: The Cumulative Air Kerma (CAK) has traditionally been a surrogate metric for patient exposure to ionizing radiation during clinical esophagrams. Recently, UAB technologists observed that a ne...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

SRS Treatment Planning for Brain Metastases on Varian Truebeam and Elekta Gamma Knife Icon

Authors: Carl D. Elliston, Lawrence Koutcher, Michael J. Price, Adam C. Riegel, Michael B Sisti, Tony J.C. Wang, Andy (Yuanguang) Xu

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: An inverse treatment planning software was recently introduced to Gamma Knife radiosurgery. The purpose of this study is to compare the plan quality of the Gamma Knife ”Lightning” with that o...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Towards In Vivo Dosimetry for Adaptive MR-Guided Radiation Therapy: Initial Report on a Prototype Injectable Dosimeter

Authors: Daniel Ball, Alex Dresner, Geoffrey S. Ibbott, Leonard H. Kim, Christopher Tyerech, Sebastián Vega

Affiliation: MD Anderson Cancer Center at Cooper, Cooper Medical School of Rowan University, The American Board of Radiology, Department of Radiation Oncology, University of Pennsylvania, Rowan University, Philips Healthcare MR Oncology

Abstract Preview: Purpose:
In vivo dosimetry is valuable to radiation therapy for its ability to report the actual dose received by patients but is currently limited to surface and intracavitary measurements, leavin...

Validation of 3D Pseudo-Dose Map Reconstructed from Multi-View Cherenkov Images in Total Skin Electron Therapy

Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison

Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...