Authors: Ke Colin Huang, Zirui Jiang, Joshua Low, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue
Affiliation: Purdue University, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Enhancing the accuracy of tumor response predictions enables the development of tailored therapeutic strategies for patients with breast cancer (BCa). In this study, we developed deep-radiomi...
Authors: Gary Y. Ge, Charles Mike Weaver, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: The recently introduced CMS regulation on CT dose and image quality mandates the use of global noise as the metric for image quality assessment. The regulation cites two methods for calculati...
Authors: Yunxiang Li, Hua-Chieh Shao, Chenyang Shen, Jing Wang, Jiacheng Xie, Shunyu Yan, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Accurate liver deformable motion tracking is essential in image-guided radiotherapy to enable precise tumor targeting during treatment. We developed a conditional point cloud diffusion model ...
Authors: Mitya M. Barreto, Nichole A. Harris
Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center
Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...
Authors: Yidong Yang, Haolin Zhan
Affiliation: Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: To develop a fast low-dose method for beam blocker-based CBCT scatter correction and evaluate image quality in phantom study.
Methods: The full number of scatter projections were collected...
Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya
Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia
Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...
Authors: Huay Din, Grace Jianan Gang, Grace Hyun Kim, Michael F. McNitt-Gray, Joseph W. Stayman, Yijie Yuan
Affiliation: Johns Hopkins University, John Hopkins University, University of Pennsylvania, David Geffen School of Medicine at UCLA
Abstract Preview: Purpose:
Radiomics rely on quantitative features to discern underlying biological signatures. However, feature dependence on the imaging systems themselves hampers the creation of reproducible and ...
Authors: Bryan Bednarz, Malick Bio Idrissou, Campbell Haasch, Reinier Hernandez
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Medical Physics, School of Medicine and Public Health, University of WisconsinâMadison, University of Wisconsin - Madison
Abstract Preview: Purpose: Quantitative optical imaging is a powerful tool in murine models for assessing tumor growth and metastatic spread using bioluminescence imaging (BLI) and for detecting radiopharmaceutical upt...
Authors: Benito De Celis Alonso, Braian Adair Maldonado Luna, Gerardo Uriel Perez Rojas, RenĂ© Eduardo RodrĂguez-PĂ©rez, Kamal Singhrao
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla
Abstract Preview: Purpose: Artificial Intelligence (AI)-generated synthetic CT (sCT) images can be used to provide electron densities for dose calculation for online adaptive MRI-guided stereotactic body radiotherapy (...
Authors: Chuxiong Ding, Xuejun Gu, Heejung Kim, Weiguo Lu, Yang Kyun Park, Yulong Yan
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: The purpose of this study was to develop and evaluate a Monte Carlo (MC) dose calculation software (DosemanCK) for secondary dose verification of CyberKnife (CK) treatment plans. Unlike tradi...
Authors: Tsuicheng D. Chiu, Strahinja Stojadinovic, Aaron Thomlinson, You Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas Southwestern Medical Center, University of Texas Southwestern Medical Center
Abstract Preview: Purpose: Design and develop an automated verification and validation platform for the Elekta Leksell Gamma Knife (GK) Icon/Esprit High-Definition Motion Management (HDMM) system.
Methods: The H...
Authors: Shari Damast, Svetlana Kuznetsova, Christopher J. Tien
Affiliation: Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: Current contour similarity evaluation approaches (Dice Similarity Coefficient, Mean Distance to Agreement) are limited to geometric agreement without assessment of ultimate dosimetric impact....
Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine
Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...
Authors: Anna E. Rodrigues, Yuhao Wang, Deshan Yang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: Accurate motion margin definition in StereoTactic Arrhythmia Radiotherapy (STAR) requires accurate cardiorespiratory motion assessment. However, respiratory 4DCT (r4DCT) images are affected b...
Authors: Marios Myronakis, Kyriaki Theodorou
Affiliation: Medical Physics Department, Medical School, University of Thessaly
Abstract Preview: Purpose: The development of an integrated application framework for rapid, seamless, and automated calculation of absorbed organ dose for individual patients undergoing kV CBCT imaging over the course...
Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts
Affiliation: University of Michigan, Oregon Health & Science University
Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25Ă25cmÂČ), which can reduce beam fluence by up to 93% compared to the unmodified ...
Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal
Affiliation: University Hospital Southampton
Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...
Authors: Denisa R. Goia, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Joseph Shields, Christopher Tyerech
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: HyperSight is a new platform for image-guided radiation therapy, offering advanced reconstruction algorithms, a large field-of-view, and rapid acquisition times. To validate the performance o...
Authors: Zijia Guo, Michael F. McNitt-Gray, Frederic Noo, Karl Stierstorfer
Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA
Abstract Preview: Purpose: Accurately assessing lung parenchyma health is critically important in the management of patients with chronic obstructive pulmonary disease. CT attenuation values are valuable for this purpo...
Authors: David Brizel, Kyle J. Lafata, Jian-Guo Liu, Yvonne M Mowery, Yvonne M Mowery, William Paul Segars, Jack B Stevens
Affiliation: Department of Physics, Duke University, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh
Abstract Preview: Purpose: To develop a technique to quantify tumor topology using a unifying mathematical framework that integrates texture and morphology and to evaluate its feasibility as a prognostic biomarker for ...
Authors: Stephen R. Bowen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Jing Sun, Jiajie Wang, Shouyi Wang, Faisal Yaseen, Xiaojing Zhu
Affiliation: Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Shanghai University of Electric Power, Fred Hutchinson Cancer Center, University of Texas at Arlington
Abstract Preview: Purpose: Accurate prediction of patient response to radiotherapy plays a crucial role in monitoring disease progression and assessing treatment efficacy, enabling clinicians to develop personalized th...
Authors: Walaa Abdelfadeel, Reagan Thomas Dugan, Tiffany Kinsey, Cameron Kofler, Zheng Feng Lu, Ingrid S. Reiser, Gregory Stacy, Sara Wallace
Affiliation: University of Chicago Medicine, University of Chicago
Abstract Preview: Purpose: To develop an accurate, vendor-neutral method for estimating geometric magnification at the plane of the hip joint on standing anterior-posterior (AP) radiographs for digital templating of to...
Authors: Mojtaba Behzadipour, Siyong Kim, Mitchell Polizzi, Richard R. Wargo, Lulin Yuan
Affiliation: VCU Health - Department of Radiology, Virginia Commonwealth University
Abstract Preview: Purpose:
The purpose of this study is to develop a method for generating missing tissue in CT scans of patients with large body sizes, where the field of view (FOV) of the scanner fails to capture ...
Authors: Indrin J. Chetty, Jing Cui, Mitchell Kamrava, Tiffany M. Phillips, Jennifer M. Steers, Brad Stiehl
Affiliation: Department of Radiation Oncology,Cedars-Sinai Medical Center, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Auto-contouring for HDR interstitial brachytherapy can be confounded by large deformation in anatomy and image quality. Here we evaluated the performance of an AI-based auto-contouring softwa...
Authors: Pradeep Bhetwal, Wookjin Choi, Adam Dicker, Rupesh Ghimire, Yingcui Jia, Lauren Nkwonta, Yevgeniy Vinogradskiy, Wentao Wang, Maria Werner-Wasik
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Multi-disciplinary clinics are becoming standard of care for patients with lung cancer treated with SBRT. To improve clinical decision support in a multi-disciplinary clinic, it would be bene...
Authors: Nobuki Imano, Yuzuha Kadooka, Daisuke Kawahara, Misato Kishi, Yuji Murakami, Shumpei Onishi
Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University, Department of Neurosurgery, Hiroshima University Hospital
Abstract Preview: Purpose: Radiomics has proven useful in predicting overall survival in glioblastoma (GBM) patients, but consistent molecular correlations remain unidentified, leaving its biological basis unclear. Thi...
Authors: Yunxiang Li, Xinlong Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Acquiring high-resolution (HR) proton density (PD) images is time-consuming, while lower-resolution (LR) PD scans are faster but can lack sufficient details. We propose CycleHR, a T2-contrast...
Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...
Authors: Aman Anand, Jonathan B. Ashman, Martin Bues, Brady S. Laughlin, Lisa McGee, Justin Pettit, Fan Yang, Libing Zhu
Affiliation: Department of Radiation Oncology Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: Proton therapy (PT) offers significant clinical and economic benefits across various cancers, whereas it also has faced skepticism due to its historically high costs and perceived overuse in ...
Authors: Cem Altunbas, Farhang Bayat, Roy Bliley, Rupesh Dotel, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic, University of Colorado Anschutz Medical Campus
Abstract Preview: Purpose: Automatic segmentation of anatomical structures in CBCT images is key to enabling dose delivery monitoring and online plan modifications in radiotherapy. However, poor image quality can degra...
Authors: Jie Hu, Zhengdong Jiang, Nan Li, Tie Lv, Yuqing Xia, Shouping Xu, Gaolong Zhang, Wei Zhao, Changyou Zhong
Affiliation: School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Radiotherapy Department of Meizhou Peopleâs Hospital (Huangtang Hospital), UT Health San Antonio, National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100021, PeopleÊŒs Republic of China, Department of Radiation Oncology
Abstract Preview: Purpose: Patients usually undergo cone-beam computed tomography (CBCT) scans which are used for patient set-up before radiotherapy. However, the low image quality of CBCT hinders its use in adaptive r...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unityâs 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Shahed Badiyan, Bin Cai, Tu Dan, Michael Dohopolski, Steve B. Jiang, Deepkumar Mistry, Arnold Pompos, Robert Timmerman, Jing Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Biology-guided radiotherapy (BGRT) offers significant potential for personalized and adaptive cancer treatment, with clinically available systems such as SCINTIX from Reflexion now being intr...
Authors: Ye Chen, Koki Kasamatsu, Taeko Matsuura, Taichi Murakami
Affiliation: Hokkaido University, National Institutes for Quantum Science and Technology (QST)
Abstract Preview: Purpose: In proton therapy, CT-based estimation of the stopping power ratio (SPR) is a significant source of range uncertainty. Protoacoustics have been developed to estimate the range in vivo, but fe...
Authors: Carlo Greco, Joep Stroom, Sandra Vieira
Affiliation: Champalimaud Center for the Unknown
Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...
Authors: Debora de Souza Antonio, Romy Guthier, Konrad Pawel Nesteruk, Erno Sajo, William Paul Segars, Gregory C. Sharp, Atchar Sudhyadhom, Hengyong Yu
Affiliation: Massachusetts General Hospital, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Brigham and Womenâs Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Massachusetts General Hospital and Harvard Medical School, University of Massachusetts Lowell
Abstract Preview: Purpose: To develop an open-access toolkit for rapidly generating simultaneously realistic CT scans and low-field MR images of the abdominal region, based on patient data, while employing an XCAT phan...
Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang
Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...
Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders
Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University
Abstract Preview: Purpose: This study assesses Philipsâ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.
Methods:...
Authors: James Ward, Anzi Zhao
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: This study investigates the correlation between the backlight runtime in diagnostic displays and their corresponding performance, which may aid in making informed decisions regarding the timi...
Authors: Yile Fang, Leslie Lamb, Nathaniel David Mercaldo, Kai Yang
Affiliation: Massachusetts General Hospital
Abstract Preview: Purpose: To quantitatively evaluate power-law exponent ÎČ as a potential image-based breast cancer risk factor.
Methods: Two groups of breast cancer screening cohorts (target vs. control, 20 sub...
Authors: Zhitao Dai
Affiliation: Chinese Academy of Medical Sciences Cancer Hospital Shenzhen Hospital
Abstract Preview: Purpose: To investigate the accuracy of 3D printed individualized vaginal template assisted pre-planning in the interstitial implantation of cervical cancer, to examine the advantages when compared wi...
Authors: Sophie Bockel, Eric Deutsch, Frederic Dhermain, Ibrahima Diallo, Anh Thu Le, Elaine Limkin, Pauline Maury, Charlotte Robert, Killian Sambourg, Camilla Satragno, Cristina Veres, François de Kermenguy
Affiliation: Gustave Roussy, Département de radiothérapie, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique
Abstract Preview: Purpose:
To study the correlation between the dose to circulating lymphocytes as evaluated by the LymphoDose framework and the incidence of severe radiation-induced lymphopenia (sRIL) in patients t...
Authors: Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Nancy Y Lee, Anyi Li, Jung Hun Oh, Teeradon Treechairusame, Pengpeng Zhang
Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To automatically monitor weekly anatomical changes of parotid glands during adaptive radiotherapy of head and neck cancers, systematically assess the relationship between parotid gland shrink...
Authors: Yan Chu, Madison Emily Grayson, Radhe Mohan, Pablo P. Yepes
Affiliation: UT Health Science Center at Houston, Rice University, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Radiation-induced lymphopenia (RIL) is a common adverse effect of radiation therapy, negatively impacting overall survival and anti-PD1 immunotherapy efficacy. Our lab previously developed a ...
Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan
Affiliation: University of Florida
Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...
Authors: Izabella L. Barreto, Aroon Pressram
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: Our clinical dual energy CT (DECT) head protocol reconstructs iodine-suppressed virtual non-contrast (VNC) images using the vendor-recommended slope for material discrimination. However, this...
Authors: Ehsan Abadi, Darrin Byrd, Paul E. Kinahan, Katie Marie Olivas, Ehsan Samei
Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, University of Washington
Abstract Preview: Purpose: To evaluate the impact of respiratory motion during CT acquisitions on PET image quantification using an integrated PET-CT simulation pipeline.
Methods: A validated CT simulator (DukeSim) ...
Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan
Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences
Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...
Authors: Yuemeng Feng, Hamid Sabet
Affiliation: Massachusetts General Hospital, Harvard Medical School
Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...
Authors: Austin Castelo, Xinru Chen, Caroline Chung, Laurence Edward Court, Jaganathan A Parameshwaran, Zhan Xu, Jinzhong Yang, Yao Zhao
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose:
To develop a deep learning-based segmentation model to automatically delineate tumors from full-body PET/CT images.
Methods:
PET/CT image pairs of 91 patients were collected for this...
Authors: Hailun Pan, Yingli Yang, Jie Zhang, Yibin Zhang
Affiliation: Department of Radiation Oncology,Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Department of Radiology, Ruijin Hospital, Department of Radiation Oncology, Ruijin Hospital, , Shanghai Jiaotong University School Of Medicine, Shanghai United imaging Healthcare Advanced Technology Research Institute
Abstract Preview: Purpose: Accurate patient positioning is critical in radiotherapy (RT) to ensure effective treatment delivery and minimize harming surrounding healthy tissues. Vertebral misalignment during RT setup h...
Authors: Chase Cochran, Shane McCarthy, Damodar Pokhrel, William St Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: Manually generating intraocular stereotactic radiosurgery (SRS) plans involves significant challenges, including lengthy planning times and inter-planner variability. Knowledge-based SRS plan...
Authors: Hongyi Jiang, Fang-Fang Yin
Affiliation: Duke University, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose:
Imaging moving tissues using PET-CT can be difficult. Separating signal into phases during construction reduces signal count and increases influence of noise. Algorithms that use signal fr...
Authors: Majd Antaki, Rohini Bhatia, Gayoung Kim, Yosef Landman, Junghoon Lee, Akila N. Viswanathan
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Physics and Advanced Development Elekta
Abstract Preview: Purpose: Brachytherapy is a standard radiation therapy approach for cervical cancer, which directly delivers radiation source to the tumor using catheters. Treatment planning requires identification o...
Authors: Hannah Grover, Andrew J. Sampson
Affiliation: Oregon Health & Science University, UT Health San Antonio
Abstract Preview: Purpose: The goal of this work was to quantify the dosimetric impact of iodinated contrast on fibroglandular breast tissue to better inform clinical risk and benefit assessments when determining the m...
Authors: Victor B. Kassey, Maciej M. Kmiec, Periannan Kuppusamy, Sergey V. Petryakov, Conner Ubert
Affiliation: Dartmouth College
Abstract Preview: Purpose: Tumor hypoxiaâa state of reduced oxygen supplyâis well known to affect treatment response, particularly in radiotherapy and chemotherapy. Oxygen-enhanced magnetic resonance imaging (OE-MRI) u...
Authors: Steven Brown, Mike Hopkins, Jerimy C. Polf, Scott Sawyer, Benjamin L. Viglianti
Affiliation: H3D, inc, University of Michigan, M3D, Inc, M3D Imaging
Abstract Preview: Purpose: We characterized the sensitivity, energy dependence, and calibrated dose rate for a radiation imaging survey meter (RAVIN Cam; M3d inc., Ann Arbor MI) based on cadmium zinc telluride (CZT) cr...
Authors: Yingxuan Chen, Jun Li, Alexis N. Webb
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...
Authors: Rodrigo Delgadillo, Nesrin Dogan, Benjamin J. Rich, Stuart E Samuels, Levent Sensoy
Affiliation: University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Daily Cone beam CT (CBCT) images may be useful in detecting early morphological changes during head and neck cancer radiotherapy. The aim of this study was to evaluate the performance of CBCT...
Authors: Ashok Bhandari, Kurtis Johnson, Yu Lei, Tianzhe Li, Kyuhak Oh, Shuo Wang, Chi Zhang, Su-Min Zhou
Affiliation: University of Nebraska Medical Center
Abstract Preview: Purpose: The purpose of this study was to leverage neural network visualization tools to detect high-attention areas indicative of treatment failure in lung SBRT by examining correlation matrices betw...
Authors: Jean Bourbeau, Jim Hogg, Miranda Kirby, Meghan Koo, Kalysta Makimoto, Wan Tan
Affiliation: Montreal Chest Institute of the Royal Victoria Hospital, McGill University Health Centre, Toronto Metropolitan University, Centre for Heart Lung Innovation, University of British Columbia
Abstract Preview: Purpose: Chronic obstructive pulmonary disease (COPD) exacerbations are burdensome to patients and healthcare systems. CT imaging-derived measures of emphysema and airway remodeling have been shown to...
Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose:
PET is used in radiotherapy workflows for accurate target delineation. However, a separate CT scan is typically required for attenuation correction in PET imaging and for registering PET-d...
Authors: Austen N. Curcuru, Arash Darafsheh, Winter Green, Yao Hao, Baozhou Sun, Tiezhi Zhang, Tianyu Zhao, Xiandong Zhao
Affiliation: WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine, Washington University in St. Louis, University of South Florida, Baylor College of Medicine
Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) requires precise setup imaging due to the sharp dose gradients and rapid distal fall-off seen in proton therapy dose distributions. Additionally, onl...
Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang
Affiliation: 4Physikalisch-Technische WerkstÀtten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...
Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan
Affiliation: Medical University of South Carolina
Abstract Preview: Purpose: To characterize optimal optimization workflow and settings for a single large target utilizing the Leksell GammaPlan Lightning Optimizer.
Methods: An anonymized dataset containing a large ...
Authors: Kaile Li, Esmail Parsai
Affiliation: Alexander T. Augusta Military Medical Center, Alexander T. Augusta Miliary Medical Center
Abstract Preview: Purpose: To evaluate the sensitivity of the portal dosimetry system with the Arc CHECK system at identical Volumetric Modulated Arc Therapy (VMAT) setup
Methods: An Arc CHECK system from Sun Nuclea...
Authors: Girish Bal, Thomas I. Banks, Bin Cai, Yesenia Gonzalez, Zohaib Iqbal, Paul M. Medin, Rameshwar Prasad, Chenyang Shen, Robert Timmerman, Yuanyuan Zhang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, UT Southwestern Medical Center, RefleXion Medical
Abstract Preview: Purpose: Each year more than one million pacemakers and 200k cardioverter-defibrillators are implanted in patients worldwide. The presence of a CIED introduces challenges to the delivery of radiation ...
Authors: Ergun E. Ahunbay, Colette Gage, Abdul Kareem Parchur, Eric S. Paulson
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: AI-generated synthetic CT (sCT) images address challenges with prior sCT approaches, including atlas- and threshold-based methods. Commercial AI-based sCT tools have been introduced. This wor...
Authors: Dan Giardina, John Karageorgiou, Chris Malone, Naganathan Mani, Allan Thomas
Affiliation: Washington University School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine
Abstract Preview: Purpose: Relative to planar imaging, MAA-SPECT/CT offers more reliable lung shunt fraction (LSF) and lung mean dose (LMD) estimates in 90Y radioembolization. But lung truncation in SPECT/CT can limit ...
Authors: Rex Carden, Carlos E. Cardenas, Ho-hsin Rita Chang, John B Fiveash, Heinzman A. Katherine, Yogesh Kumar, Gaurav Nitin Rathi, Richard A. Popple, Kayla Lewis Steed
Affiliation: University of Alabama at Birmingham
Abstract Preview: Purpose: Brain metastases (BMs) often require multiple radiotherapy (RT) courses as new lesions appear. Comparing follow-up imaging with prior RT plans is time-intensive. We developed an AI tool that ...
Authors: Theodore Higgins Arsenault, Beatriz Guevara, Rojano Kashani, Raymond F. Muzic, Gisele Castro Pereira, Alex T. Price
Affiliation: University Hospitals Seidman Cancer Center, Case Western Reserve University Department of Biomedical Engineering
Abstract Preview: Purpose: Accurate dose prediction in radiotherapy is essential for treatment planning. This study evaluates four nnUnet-based models using the OpenKBP head and neck dataset: a baseline model (Model 1)...
Authors: Minsong Cao, Amar Kishan, Yi Lao, An Liu, Beth Neilsen, X. Sharon Qi, Kun Qing, Ke Sheng, Michael Steinberg, Luca F Valle, Terence Williams
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Department of Radiation Oncology, City of Hope Medical Center, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To investigate the clinical relevance of planned versus delivered doses in toxicity associations utilizing localized assessment of genitourinary (GU) toxicity in bladder subregions among pros...
Authors: Paul Deak, Yang Li, Mark Pankuch, Yanling Qu, Maggie Stauffer, Hazel Wang
Affiliation: Northwestern Medicine Proton Center, GE, Northwestern Medicine
Abstract Preview: Purpose: The objective is to evaluate Relative Stopping Power(RSP) accuracy of ultra-fast switching KV Dual-Energy CT(DECT) in animal tissue and compare it to the RSP converted from Single Energy CT(S...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...
Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich
Affiliation: Rush University
Abstract Preview: Purpose: This study evaluates the impact of ultra-high resolution (UHR) mode on the visualization of small vessels in coronary computed tomography angiography (CTA) using a photon-counting CT scanner....
Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...
Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin
Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...
Authors: Gourav Jhanwar, Mojtaba Tefagh, Masoud Zarepisheh
Affiliation: The University of Edinburgh, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
Radiotherapy treatment planning involves solving computationally-intensive and time-consuming optimization problems. Central to these problems is a large matrix known as the dose-influence...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier
Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...
Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...
Authors: Abdusalam Abdukerim
Affiliation: Institute for Medical Imaging Technology, Ruijin Hospital
Abstract Preview: Purpose:
Coronary computed tomography angiography (CCTA) is the gold-standard non-invasive test for coronary artery disease (CAD), but iodine contrast agents (ICA) pose limitations in specific popu...
Authors: Yang Sheng, Qingrong Jackie Wu, Qiuwen Wu, Xin Wu, Dongrong Yang
Affiliation: Duke University Medical Center
Abstract Preview: Purpose: Convergence speed is crucial for an optimizer. Faster convergence leads to better solutions with fewer iterations and less time. Recently, a machine learning (ML)-assisted framework employing...
Authors: Ryan Andosca, Igor Barjaktarevic, Peter Boyle, Jie Deng, Minji Victoria Kim, Michael Vincent Lauria, Daniel A. Low, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Jack Neylon, Dylan P. O'Connell, Ricky R Savjani
Affiliation: Department of Pulmonology, University of California Los Angeles, University of California, Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, UCLA, UCLA Radiation Oncology
Abstract Preview: Purpose: To develop a Hounsfield Unit ventilation-based correction method for use with model-based CT when used as a replacement for 4DCT.
Methods: The model-based CT we employ is termed 5DCT, whic...
Authors: Lars R Furenlid, Chiao Huang, Matthew A. Kupinski, Brian W. Miller
Affiliation: University of Arizona, Departments of Radiation Oncology and Medical Imaging, University of Arizona
Abstract Preview: Purpose: To sample correlated k-constants in tissue-compartment model for pharmacokinetic study in targeted alpha therapy.
Methods: This work simulated the biodistribution of PSMA-11 tracers labele...
Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu
Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center
Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...
Authors: Robbie Beckert, Austen N. Curcuru, Farnoush Forghani, Yi Huang, Geoffrey D. Hugo, Hyun Kim, Eric Laugeman, Luke Christian Marut, Thomas R. Mazur, Allen Mo, Emily Sigmund
Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine in St. Louis, Wash U Medicine, Washington University in St. Louis, Department of Radiation Oncology, Washington University School of Medicine in St. Louis
Abstract Preview: Purpose: Adaptive SBRT is resource intensive, requiring additional personnel for online planning, and should be reserved for cases where it is most beneficial. The purpose of this research is to creat...
Authors: Magdalena Bazalova-Carter, James Day, Xinchen Deng
Affiliation: University of Victoria
Abstract Preview: Purpose:
Ring artifacts in Photon-Counting Computed Tomography (PCCT) images can degrade image quality. this study aims to suppress ring artifacts with a novel autoencoder-based framework that leve...
Authors: Jacqueline M. Andreozzi, Tess Armstrong, Shiva Bhandari, John M Bryant, Jessica M Frakes, David J. Gladstone, Sarah E Hoffe, Kujtim Latifi, Arash Naghavi, Steven Nichols, Ibrahim M. Oraiqat, Russell Palm, Gage H. Redler, Stephen A Rosenberg, Joseph Weygand
Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Thayer School of Engineering, Dartmouth College, Department of Radiation Oncology, Ohio State University, Moffitt Cancer Center, Department of Radiation Oncology, Moffitt Cancer Center
Abstract Preview: Purpose: The MR-linac provides unique opportunities for integrating advanced imaging into radiotherapy workflows, but the lower sensitivity of systems like the 0.35T model can pose challenges for diff...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varianâs SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Matthew Stephen Andriotty, Taoran Cui, Harold Y Hu, Ke Nie, Tan Phan, Xiao Wang, Ning J. Yue, Chengzhu Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, Basis Scottsdale
Abstract Preview: Purpose: Metallic implants are often non-isocentric, and their exact volumes/orientations/shapes are difficult to capture and contour accurately on CT images even if that information is known beforeha...
Authors: Xinhui Duan, Roderick W. McColl, Mi-Ae Park, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang
Affiliation: UT Southwestern Medical Center, Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center
Abstract Preview: Purpose:
Image-based deep-learning noise-reduction techniques have been developed for photon-counting CT (PCCT) to improve image quality with reduced radiation dose. The denoising strength is typic...
Authors: Mohamed Bahaaeldin Mohamed Afifi, Nahla Nagy Ahmad Ataalla, Ahmed A. Eldib
Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.
Abstract Preview: Purpose: Optimizing CT imaging parameters is crucial for balancing radiation dose, contrast resolution, and accurate Hounsfield unit representation, particularly in radiotherapy treatment planning. Th...
Authors: Morgan A. Daly, David J. Goodenough, Andrew M. Hernandez, John M. Hoffman, Joshua Levy, Michael F. McNitt-Gray, Ali Uneri, Bino Varghese
Affiliation: University of California, George Washington University, David Geffen School of Medicine at UCLA, Johns Hopkins Univ, University of Southern California, The Phantom Laboratory
Abstract Preview: Purpose: Quantitative imaging is affected by CT acquisition and reconstruction conditions, limiting robustness in multi-site or -scanner studies. This work aimed to develop a dataset that will enable ...
Authors: Peter Balter, Elaine Eunnae Cha, Seungtaek Choi, Yao Ding, Eun Young Han, Yusung Kim, Rajat J. Kudchadker, Belinda Lee, Surendra Prajapati, Reza Reiazi, Ergys D. Subashi, Sarath Vijayan, Jinzhong Yang, Yao Zhao
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: This study evaluates the feasibility of an MR-only simulation, planning, and treatment (MROSPT) workflow for pelvic cancer patients using synthetic CT generated from MRI data. By validating s...
Authors: Pradeep Bhetwal, Yingxuan Chen, Wookjin Choi, Michael Dichmann, Adam Dicker, Rupesh Ghimire, Yevgeniy Vinogradskiy, Maria Werner-Wasik
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Radiomics has emerged as a powerful tool in medical research. However, the lack of standardized and reproducible pipelines limits its clinical adoption. This study developed a robust and scal...
Authors: Ahmad Algohary, Adrian Breto, Quadre Emery, Radka Stoyanova
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami
Abstract Preview: Purpose:
To develop a foundation model (U-Found) for multiparametric MRI (mpMRI) of the prostate by using self-supervised learning to prove the feasibility of a prostate-oriented foundation model u...
Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park
Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital
Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...
Authors: Victoria Doss, Tsion Gebre, Rachel B. Ger, Esi A Hagan, Elaina Hales, Russell K Hales, Xun Jia, Heng Li, Dezhi Liu, Todd R. McNutt, Meti Negassa, Anas Obaideen, Tinker Trent, K. Ranh Voong, Cecilia FPM de Sousa
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: As cancer care advances, more patients require re-irradiation, yet evidence-based data is lacking. This study aimed to develop a thoracic re-irradiation database and explore time-dependent re...
Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav
Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)
Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...
Authors: Diandra Ayala-Peacock, Lindsey Hendricks Bloom, Oana I. Craciunescu, Julie A. Raffi, Megan K. Russ, Ryan Sanford, Rajesh Venkarataman
Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System, Duke University Medical Center, Duke University, Eigen Health, Duke Univesity
Abstract Preview: Purpose: To establish a robust QA framework to characterize and ensure accuracy, reliability, and reusability of a transrectal ultrasound (TRUS)-based needle tracking system (NTS) for clinical HDR GYN...
Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway
Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center
Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...
Authors: Huiming Dong, Jonathan Pham, X. Sharon Qi, Ann Raldow
Affiliation: Department of Radiation Oncology, University of California, Los Angeles
Abstract Preview: Purpose: The study aimed to investigate longitudinal apparent diffusion coefficient (ADC) as an early biomarker of treatment response in patients with locally advanced rectal cancer (LARC) undergoing ...
Authors: Theresa Busch, Robert H Hadfield, Madelyn Johnson, Baozhu Lu, Hongjing Sun, Brian C. Wilson, Weibing Yang, Timothy C. Zhu
Affiliation: University of Glasgow, University of Toronto, University of Pennsylvania
Abstract Preview: Purpose: Direct detection of singlet-state oxygen (ÂčOâ) is crucial for advancing type II photodynamic therapy (PDT), but its short lifetime makes in vivo measurement highly challenging. Although Photo...
Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei
Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...
Authors: Robert Fucetola, Jiayi Huang, Zhihua Liu, Chongliang Luo, Tong Zhu
Affiliation: Washington University School of Medicine, Washington University in St. Louis, School of Medicine
Abstract Preview: Purpose:
This prospective observational study investigates radiation-induced white matter (WM) injuries using longitudinal diffusion tensor imaging (DTI) in patients with diffuse glioma following r...
Authors: Motohiro Kawashima, Adrian Kugara, Masao Nakao, Shuichi Ozawa, Mutsumi Tashiro, Maria Varnava
Affiliation: Gunma University Heavy Ion Medical Center, Hiroshima High-Precision Radiotherapy Cancer Center
Abstract Preview: Purpose: This study aimed to evaluate the time-dependent dose rate characteristics of a scanning carbon ion beam using a fast-response plastic scintillator detector (PSD), with a focus on its potentia...
Authors: Lining Chen, Zhitao Dai, Shumei Jia, Yajun Jia, Enzhuo Quan
Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen HospitalïŒ Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: This work reviewed 12 patient clinical LRT treatments in physics view including geometric and dosimetric parameters and discussed the pros and cons related to the latter.
Methods: Geometri...
Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang
Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey
Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...
Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard
Affiliation: Warren Alpert Medical School of Brown University
Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...
Authors: Daniel H. Bushe, Arthur Lalonde, Hoyeon Lee, Harald Paganetti, Brian Winey
Affiliation: Universite de Montreal, Massachusetts General Hospital, Massachusetts General Hospital and Harvard Medical School, University of Hong Kong
Abstract Preview: Purpose: Improving the precision and fidelity of daily volumetric imaging is essential for enabling adaptive proton therapy (APT). While cone-beam CT (CBCT) provides daily volumetric imaging, their ut...
Authors: Dharmin D. Desai, Ellis Lee Johnson, Philip J. Kallenberg, Kapil M. Mishra
Affiliation: Spectrum Medical Physics, University of Kentucky, Varian Advanced Oncology Solutions
Abstract Preview: Purpose: The âAsk For Itâ (AFI) manual optimization strategy has been shown to generate high quality SRS plans within Eclipse. The purpose of this work is to directly compare manually generated Eclips...
Authors: Dennis A. Cheek, Wei Luo, Cameron Thayer-Freeman, Brien Timothy Washington
Affiliation: UT Southwestern Medical Center, University of Kentucky, Department of Radiation Medicine, University of Kentucky
Abstract Preview: Purpose: To investigate the effect of variation in the α/ÎČ of cervical cancer on clinical outcome for cervix cancer patients treated with radiation therapy.
Methods: A distribution of experimentall...
Authors: Rita Buono, Elisabetta Cagni, Roberta Castriconi, Surendra Bahadur Chand, Marco Esposito, Claudio Fiorino, Valeria Landoni, Aldo Mazzilli, Eugenia Moretti, Lorenzo Placidi, Giulia Rambaldi Guidasci, Alessia Tudda
Affiliation: IRCCS San Raffaele Scientific Institute, Department of Advanced Technology, IRCCS Regina Elena National Cancer Institute, ASU FC Medical Physics, University Hospital of Parma AOUP, ICTP, B.P. Koirala Memorial Cancer Hospital, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Fatebenefratelli Isola Tiberina â Gemelli Isola
Abstract Preview: Purpose: To explore the feasibility and educational impact of transferring knowledge-based planning (KBP) modelsâdeveloped using Italian breast radiotherapy dataâto a Nepalese hospital, thereby demons...
Authors: Jongduk Baek, Jooho Lee, Adam S. Wang
Affiliation: Stanford University, Yonsei University
Abstract Preview: Purpose: Optimizing the balance between radiation dose and image quality in computed tomography (CT) is important for minimizing patient X-ray exposure while maintaining diagnostic accuracy. While rad...
Authors: Lian Duan, Stephen F. Kry, Hunter S. Mehrens, Christine Peterson, Paige A. Taylor
Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center
Abstract Preview: Purpose: To develop predictive models for IROC SRS head phantom audits and to identify important factors influencing institutional performance.
Methods: The IROC SRS head phantom includes two TLDs ...
Authors: James Brugarolas, Meixu Chen, Raquibul Hannan, Payal Kapur, Jing Wang, Kai Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: Accurate prognosis of clear cell renal cell carcinoma (ccRCC) is essential for guiding personalized treatment planning. In this study, we present a multi-modal ensemble model (MMEM) that inte...
Authors: Yang Lei, Haibo Lin, Tian Liu, Charles B. Simone, Shouyi Wei, Ajay Zheng
Affiliation: Icahn School of Medicine at Mount Sinai, New York Proton Center
Abstract Preview: Purpose: Radiation-induced lung injury (RILI), encompassing pneumonitis and fibrosis, represents a critical dose-limiting factor in lung cancer radiation therapy. Variability in treatment outcomes is ...
Authors: Diana Cardona, Casey C. Heirman, William Jeck, Kyle J. Lafata, Xiang Li, Lauren M. Neldner, Jeffrey S. Nelson, Megan K. Russ, Ehsan Samei
Affiliation: Duke University, Department of Radiation Oncology, Duke University, Department of Pathology, Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Medical physicists have traditionally supported radiation-based medicine, but their expertise can translate to other image-based fields including pathology. As pathology transitions to digita...
Authors: Christopher Bartee, Justin Riley DeFrancisco, Marcos Feijoo, Siyong Kim, Tianjun Ma
Affiliation: Blue Physics LLC, Virginia Commonwealth University
Abstract Preview: Purpose: Irradiation with FLASH has been shown to decrease normal tissue toxicity while maintaining similar tumor control. To advance FLASH into the clinic, more preclinical investigations are first n...
Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...
Authors: Rajeev Gupta, Shriram Ashok Rajurkar, Teerthraj Verma
Affiliation: King George's Medical University, King George's Medical University, UP
Abstract Preview: Purpose:
The volunteer deep inspiration breath hold (vDIBH) technique is used to reduce the heart dose in left breast cancer radiotherapy. Many times, it is faced that despite rigorous exercise and...
Authors: Girish Bal, Ke Colin Huang, Christopher F. Njeh, Oluwaseyi Oderinde, Yong Yue
Affiliation: Purdue University, RefleXion Medical, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Biology-guided radiotherapy (BgRT) uses real-time positron emission tomography (PET) signals to precisely direct radiotherapy beamlets. The success of BgRT planning and delivery relies on PET...
Authors: Sunil Mani, Ilakiya Raghavendiran, Vasanthan Sakthivel, Skanda Kabilan Swamy
Affiliation: Edmond Santa Fe High School, Edmnd Deer Creek High, Cancer Specialists of North Florida, Advanced Medical Physics
Abstract Preview: Purpose: Purpose/Objective(s): To evaluate and validate the dose calculation and delivery accuracy for patients planned using diagnostic CT
Methods: A total of forty-two patients with palliative sp...
Authors: Hania A. Al-Hallaq, Xuxin Chen, Anees H. Dhabaan, Elahheh (Ella) Salari, Xiaofeng Yang
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose:
Radiomics image analysis could lead to the development of predictive signatures and personalized radiotherapy treatments. However, variations in delineation are known to affect hand-crafte...
Authors: Ali Ammar, Quan Chen, Yi Rong, Libing Zhu
Affiliation: Mayo Clinic Arizona
Abstract Preview: Purpose: To investigate how defacing algorithms, essential for patient privacy in data sharing, impact AI-based segmentation performance in CT imaging for radiation therapy. This study evaluates wheth...
Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny
Affiliation: Department of Radiation Oncology, University of Rochester
Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...
Authors: Shifeng Chen, Mariana Guerrero, Michael J. MacFarlane, Huijun Xu, Baoshe Zhang, Jinghao Zhou
Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center, University of Maryland Shore Regional Cancer Center
Abstract Preview: Purpose: The clinical value of surface-guided radiotherapy (SGRT) in prone breast cancer setups is much less established than in supine setups. This study explores SGRT's potential for prone breast pa...
Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin
Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center
Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...
Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu
Affiliation: Emory Healthcare, Emory University
Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...
Authors: Chia-Lung Chien, Wen C. Hsi, Romy Megahed, Kayla Schneider
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
The dosimetric variations induced by inter-fractional anatomical changes in intensity-modulated proton therapy could impact the clinic outcomes for head-and-neck (HN) cancer patients. This...
Authors: Emel Calugaru, Jenghwa Chang, Sean T Grace, Nicholas Harvey, Jessica Jung, Ching-Ling Teng
Affiliation: Northwell, Hofstra University, Hofstra University Medical Physics Program
Abstract Preview: Purpose: To evaluate the consistency of MRI distortion corrections across Northwell Health system and evaluate the necessity and importance of distortion QA for MRIs used for stereotactic radiosurgery...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal
Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂsica Gleb Wataghin
Abstract Preview: Purpose: This study aimed to evaluate the precision and accuracy of volume measurements for solid nodules (SNs) and ground-glass opacities (GGOs) in lung images acquired using energy-integrating CT (E...
Authors: Cem Altunbas, Farhang Bayat, Roy Bliley, Brian Kavanagh, Uttam Pyakurel, Tyler Robin, Ryan Sabounchi
Affiliation: Department of Radiation Oncology, University of Colorado School of Medicine, Taussig Cancer Center, Cleveland Clinic
Abstract Preview: Purpose: The use of image features extracted from serial CBCT images to assess radiotherapy response and toxicity is an active research area. However, poor image quality often compromises reliability ...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...
Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center
Abstract Preview: Purpose:
The RefleXionÂź X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...
Authors: Christian Fiandra, Marco Fusella, Gianfranco Loi, Silvia Pesente, Lorenzo Placidi, Claudio Vecchi, Orlando Zaccaria, Stefania Zara
Affiliation: Abano Terme Hospital, University of Turin, Maggiore della CaritĂ , Tecnologie Avanzate Srl, Fondazione Policlinico Universitario Agostino Gemelli IRCCS
Abstract Preview: Purpose: Deformable-image-registration (DIR) is essential in modern radiotherapy for adaptive RT, re-irradiation, and other clinical applications. Multimodal DIR is especially important in MRI-only wo...
Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez
Affiliation: Houston Methodist Hospital, Kaiser Permanente
Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...
Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu
Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University
Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...
Authors: Gweneth Andersen, Colleen M. Foote, David (Bo) McClatchy, Hannah McFarland
Affiliation: Massachusetts General Hospital
Abstract Preview: Purpose: To quantify the impact of MLC model differences and LINAC age on treatment plan evaluation by log file-based patient-specific QA (PSQA) through the lifetime of the machines.
Methods: 3D ga...
Authors: Stephen R. Bowen, Richard Cheng, Kylie Kang, Janice Kim, Ana Paula Santos Lima, Dominic A. Maes, Juergen Meyer, Karen Ordovas, Kerry Reding
Affiliation: Department of Radiation Oncology, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiology, University of Washington, Division of Cardiology, University of Washington, Department of Biobehavioral Nursing and Health Informatics, School of Nursing, University of Washington
Abstract Preview: Purpose: Artificial intelligence (AI)-based auto-segmentation tools can increase the efficacy and reproducibility of radiotherapy (RT) treatment planning. This study evaluates the quality of AI-genera...
Authors: Nobuki Imano, Daisuke Kawahara, Misato Kishi, Yuji Murakami
Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Graduate School of Biomedical and Health Sciences, Hiroshima University
Abstract Preview: Purpose: This study aims to develop a comprehensive Multi-score by integrating Radiomics-score (Rad-score), Gene-score derived from gene expression levels, and tumor environment Rad-score (TE-Rad-scor...
Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna
Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI
Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...
Authors: Weigang Hu, Zhenhao Li, Jiazhou Wang, Xiaojie Yin, Zhen Zhang
Affiliation: Fudan University Shanghai Cancer Center
Abstract Preview: Purpose:
This study aims to develop and validate a novel deep learning method to generate synthetic PET images for rectal cancer from MRI data. By incorporating metabolic information from the synth...
Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Wagner Henrique Marques, Raphael Morata, Victor H.F Oliveira
Affiliation: University of SĂŁo Paulo (USP), Institute of Physics
Abstract Preview: Purpose: This study investigates the feasibility of 3D printing materials in creating anthropomorphic kidney phantoms that accurately simulate the radiological properties of human tissues, for applica...
Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang
Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...
Authors: Noriko Kishi, Takashi Mizowaki, Mitsuhiro Nakamura, Yukine Shimizu
Affiliation: Kyoto University, Kyoto Univercity, Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To predict tumor positions in markerless dynamic tumor tracking (ML-DTT)-VMAT by compensating for the asynchrony between the tumor and the diaphragm.
Methods: Rotational fluoroscopic X-ray...
Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana
Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East
Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...
Authors: Niels Bassler, Jonathan Bortfeldt, Carlos Granja, Guyue Hu, Margarita Kozak, Julie Lascaud, Kirsten Lauber, Grigory Liubchenko, Jasper Nijkamp, Cristina Oancea, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Brita Singers SĂžrensen, Matthias WĂŒrl
Affiliation: Department of Nuclear Medicine, LMU University Hospital, LMU Munich, Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich), Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital, Advacam
Abstract Preview: Purpose: To apply in-vivo proton radiography (pRad) to aid image registration and treatment plan refinement for a novel precision image-guided small animal proton irradiation platform.
Methods:...
Authors: Prabhu C. Acharya, Hassan Bagher-Ebadian, Stephen L. Brown, James R. Ewing, Mohammad M. Ghassemi, Benjamin Movsas, Farzan Siddiqui, Kundan S Thind
Affiliation: Michigan State University, Oakland University, Henry Ford Health
Abstract Preview: Purpose: Accurate T1 quantification using T One by Multiple Read Out Pulse (TOMROP) sequences is essential for physiological assessments in dynamic-contrast-enhanced (DCE) MRI and T1 mapping studies. ...
Authors: Girish Bal, Jan Kralj, Ayan Mitra, PhD, Ling Shao, Matjaz Subic, Yevgen Voronenko
Affiliation: RefleXion Medical, Cosylab
Abstract Preview: Purpose: This work enhances the efficiency of radiation therapy treatment planning by optimizing the beamlet dose matrix and full patient dose computations using GPU acceleration. The Collapsed-Cone C...
Authors: Jianrong Dai, Jun Dang, Enzhuo Quan, Yong Sang, Jianan Wu
Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center / National Clinical Research Center for Cancer / Cancer Hospital & Shenzhen Hospital / Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: The current conformity index (CI) formula is distorted for radiotherapy plans with multiple, non-enclosing targets. We redefined the volume of reference isodose (VTV) parameter in the CI form...
Authors: Nan Li, Shouping Xu, Gaolong Zhang, Xuerong Zhang
Affiliation: Department of Radiation Oncology, HeBei YiZhou proton center, School of Physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose:
The 3D BRAVO sequence is an advanced magnetic resonance (MR) technique that allows for image reconstruction at any angle. It offers 1 mm gapless scanning and has a high signal-to-noise rat...
Authors: Rashmi Bhaskara, Shravan Bhavsar, Ananth Grama, Oluwaseyi Oderinde, Shourya Verma
Affiliation: Purdue University
Abstract Preview: Generating Synthetic Positron Emission Tomography from Computed Tomography using Lightweight Diffusion Model for Head and Neck Cancer
Purpose: To generate synthetic PET tumor avidity segments direc...
Authors: Wilfred R Furtado, Gary Y. Ge, James Lee, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: Despite advancements in Artificial Intelligence (AI) and its growing role in clinical practices like radiology, formal AI education remains limited in medical training. This gap contributes t...
Authors: Ryan Andosca, Peter Boyle, Grace Hyun Kim, Minji Victoria Kim, Michael Vincent Lauria, Michael F. McNitt-Gray, Gabriel Melendez-Corres, Jack Neylon, Brad Stiehl, Pang Yu Teng
Affiliation: David Geffen School of Medicine at UCLA, University of California, Los Angeles, UCLA Department of Radiology, Department of Radiation Oncology, University of California, Los Angeles, UCLA, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Endobronchial Valves (EBV) are one of the few treatment options for patients with moderate to severe emphysema. Eligibility is typically assessed from CT image data analysis including Emphyse...
Authors: Cecelia Brewington, Connor Edwards Miles All Leska-Kent, Kyrillos Grace, Katherine Hyde, Sabee Molloi, Shiva Mostafavi, Liqiang Ren, Alireza Shojazadeh, Justin Truong
Affiliation: Department of Radiology, UT Southwestern Medical Center, University of California, Irvine, University of Texas Southwestern
Abstract Preview: Purpose: To retrospectively assess image quality in coronary CT angiography (CCTA) using a patient-specific post-trigger delay (PTD) protocol, developed using half of the injection time plus a dispers...
Authors: John Ginn, Chenlu Qin, Deshan Yang
Affiliation: Duke University, Department of Radiation Oncology, Duke University
Abstract Preview: Purpose: Clinical implementation of auto-segmentation tools has been hindered by poor interpretability and generalizability of AI models, necessitating the development of automated contour quality ass...
Authors: Ulrike Dydak, Chia-Tien Hsu, Chang Geun Lee, Cora Mizimakoski, Humberto Monsivais, Jae Hong Park
Affiliation: Purdue University
Abstract Preview: Purpose: Overexposure to manganese (Mn) from inhaling welding fumes can lead to cognitive and motor deficits. We developed a whole-brain Mn-mapping approach to detect subtle but significant increases ...
Authors: Xiangli Cui, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences
Abstract Preview: Purpose:
Respiratory motion introduces substantial dose uncertainties in lung cancer radiotherapy, particularly affecting dose distribution in Simultaneous Integrated Boost-Stereotactic Body Radiot...
Authors: Max Chen, Sean Marquardt, Ben Yang, Kai Yang
Affiliation: Cary Academy, Massachusetts General Hospital, Winchester High School
Abstract Preview: Purpose: To analyze the impact of scanner model variation on the effective dose conversion factor (âk-factorâ), which is most commonly used for CT effective dose calculation.
Methods: The stand...
Authors: Jaydev K. Dave, Krzysztof R Gorny, Chunming Gu, Nicholas J. Hangiandreou, Gina K. Hesley, Myung-Ho In, Zaiyang Long, Aiming Lu, Christin A. TiegsHeiden
Affiliation: Mayo Clinic
Abstract Preview: Purpose:
MR-guided focused ultrasound (MRgFUS) enables precise tumor ablation with real-time MR-thermometry guidance. Our practice is exploring the potential use of Feraheme (Ferumoxytol), a superp...
Authors: Xinhua Li, Jie Zhang, Yifang (Jimmy) Zhou
Affiliation: University of Kentucky, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. CT can be a good modality for FVF assessment if the accuracy is adequate. We aimed to study the impa...
Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...
Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon
Affiliation: Clinique De Genolier
Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...
Authors: Marissa Brown, Geoffrey D. Clarke, Luke Norton
Affiliation: University of Texas Health Science Center at San Antonio
Abstract Preview: Purpose: To evaluate how different learning strategies affect convolutional neural network (CNN) estimates of the liver's intravoxel incoherent motion (IVIM) parameters.
Methods: A 3-stage U-Net wa...
Authors: Jason Chiang, Magnus Dahlbom, Veronica Hankil, Xinyi Li, Catherine (Caffi) Meyer, Kyung Hyun Sung
Affiliation: UCLA, University of California, Los Angeles
Abstract Preview: Purpose:
Yttrium-90 (90Y) radioembolization is a well-established therapy for large or multifocal liver tumors. Accurate dosimetry is critical but remains challenging, as low particle density risks...
Authors: Samuel L. Brady, Kevin Chen, Joseph G. Meier
Affiliation: University of Cincinnati, Cincinnati Childrens Hospital Med Ctr
Abstract Preview: Purpose: Conebeam-CT (CBCT) acquisition protocols typically do not distinguish between adults and pediatrics. In collaboration with a fluoroscopically-guided interventional (FGI) manufacturer, new, do...
Authors: Ibtisam Almajnooni, Elisabeth Weiss, Lulin Yuan
Affiliation: Virginia Commonwealth University
Abstract Preview: Purpose: We developed a deep learning neural network (DLNN) to predict the risk of radiation-induced esophagitis (RE) during lung cancer radiation therapy based on the spatial dose distribution, for t...
Authors: Richard Dortch, Thammathida Ketsiri, Zhiqiang Li, Shiv P. Srivastava
Affiliation: Barrow Neurological Institute, Dignity Health Cancer Institute, St. Joseph's Hospital & Medical Center
Abstract Preview: Purpose: Imaging the spinal cord post-surgery is challenging due to metal surgical implants, which induce signal loss and geometric distortions. Together, this hinders the visualization of the spinal ...
Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: For soft-tissue abdominal tumors, a 4D-MR may provide improved tumor tracking over the clinical standard 4D-CT. This project aims to optimize a clinically available 4D-MR pulse sequence to ac...
Authors: Mahya Ahmadzadeh, Nagarajan Kandasamy, Keyur Shah, Gregory C. Sharp, Santhosh Vadivel, John MacLaren Walsh
Affiliation: Electrical and Computer Engineering Department, Massachusetts General Hospital, Emory University, Drexel University
Abstract Preview: Purpose: In image-guided radiotherapy (IGRT), cone beam CTs (CBCTs) suffer from distortions that degrade registration with planning CTs. While CycleGANs can generate synthetic CTs (sCTs) from CBCTs, e...
Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte
Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine
Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Christian Erik Petersen, Alex T. Price, Atefeh Rezaei, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: CBCT is subject to more artifacts due to increased photon scatter, especially in areas of increased tissue heterogeneities compared to fan-beam CTs (FBCTs). Improved imaging panels combined w...
Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: The upcoming CMS regulation, titled âExcessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adultsâ, employs two measures, size-adjusted DLP (SAD) and...
Authors: Lukas M. Carter, Jazmin Schwartz
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Accurate lung shunt fraction (LSF) estimation is essential for the safety and efficacy of 90Y-radioembolization therapy. This study compares planar gamma camera imaging and tomographic SPECT-...
Authors: Marwa Y. Abdel Tawwab, Amin E Amin, Abdullah M. ElSharif, Somaia Metwally Elsayed, Magdy M. Khalil
Affiliation: School of Applied Health Science, Badr University in Cairo (BUC), Cairo, Egypt, Medical Physics, Radiation Oncology Department, Faculty of Medicine, Ain Shams University, Medical Biophysics, Department of Physics, Faculty of Science, Helwan University
Abstract Preview: Purpose: Prostate cancer radiotherapy typically employs conventional fractionation schedules over approximately eight weeks. This study investigates the effect of variations in the α/ÎČ ratio on dose c...
Authors: Ryan Alden, Tithi Biswas, Kaushik Halder, Felix Maria-Joseph, Michael Mix, Rihan Podder, Tarun Kanti Podder
Affiliation: SUNY Upstate Medical University, IIT-Roorkee, University of Florida
Abstract Preview: Purpose: Early-stage NSCLC patients undergoing SBRT often die due to intercurrent illnesses. However, prediction of overall survival (OS) remains crucial due to the risk of disease recurrence. This st...
Authors: Karyn A Goodman, Yang Lei, Tian Liu, Pretesh Patel, Jing Wang, Kaida Yang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: This study aims to improve organ-at-risk (OAR) segmentation in pancreatic cancer stereotactic body radiotherapy (SBRT) by integrating clinical guidelines into deep learning workflows. We use ...
Authors: Xuezhen Feng, Li-Sheng Geng, Haoze Li, Xi Liu, Tianyu Xiong, Ruijie Yang
Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, School of Physics, Beihang University, School of Nuclear Science and Technology, University of South China, Department of Radiation Oncology, Peking University Third Hospital
Abstract Preview: Purpose: This study aimed to develop a deep learning-based algorithm for automatically delineate gross tumor volume (GTV) for lung cancer patients, alleviating the workload of radiologists and improvi...
Authors: George Agrotis, Marios Myronakis, Dimitrios Samaras, Kyriaki Theodorou, Ioannis Tsougos, Vassilios Tzortzis, Maria Vakalopoulou, Alexandros Vamvakas, Aikaterini Vassiou, Marianna Vlychou
Affiliation: Medical Physics Department, Medical School, University of Thessaly, Department of Radiology, University of Thessaly, Netherland Cancer Institute, Department of Urology, University of Thessaly, CentraleSupelec, University Paris-Saclay
Abstract Preview: Purpose: Prostate cancer (PCa) diagnosis remains challenging due to discrepancies in Gleason Scoring (GS) and risks of overdiagnosis and underdiagnosis. Multiparametric MRI (mpMRI), including Apparent...
Authors: Eyub Y. Akdemir, Gregory A Azzam, Rupesh Kotecha, Gregory J. Kubicek, Natalia Lutsik, Eric Mellon, Siamak P. Nejad-Davarani, Parag Parikh, Karen C. Snyder
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Department of Radiation Oncology, University of Miami, Henry Ford Health
Abstract Preview: Purpose: Resection cavity volumes shrink gradually over time after surgical resection of brain metastases. Fractionated stereotactic radiosurgery (fSRS) is often delivered to the cavity to prevent rec...
Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart
Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington
Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...
Authors: Shiho Amster, Ryan Andosca, Igor Barjaktarevic, Michael Vincent Lauria, Daniel A. Low, Dylan P. O'Connell, Ann Raldow, Brad Stiehl
Affiliation: Department of Pulmonology, University of California Los Angeles, Department of Radiation Oncology, University of California, Los Angeles, Cedars-Sinai Medical Center
Abstract Preview: Purpose: Image-based biomarkers could be useful for disease diagnosis and prognosis, especially in heterogeneous lung diseases like COPD. The purpose of this study is to assess the feasibility of usin...
Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Gagandeep Saini, Nishan Shrestha, Somol Sunny
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: This study examined the impact of varying the pitch factor in hippocampal-avoidance whole-brain (HP-WB) radiotherapy treatments, utilizing the newly introduced VOLO Ultra optimization for Hel...
Authors: Maya Ataya, Clint Bahler, Ramotallah Dami Jubril, Michael Koch, Oluwaseyi Oderinde, Mark Tann
Affiliation: Purdue University, epartment of Urology, Indiana University School of Medicine, Department of Urology, Indiana University School of Medicine, Department of Radiology and Imaging Sciences, Indiana University School of Medicine
Abstract Preview: Purpose:
To investigate racial differences in the detection of biochemical recurrence (BCR) using 68Ga-PSMA-11 PET/CT, known for its improved sensitivity and specificity in patients after radical p...
Authors: Nicholas Carlson, Joel J. St-Aubin
Affiliation: University of Iowa Hospitals and Clinics, University of Iowa
Abstract Preview: Purpose: To establish baselines metrics and determine longitudinal accuracy and reproducibility of Diffusion-Weighted Imaging (DWI) and Apparent Diffusion Coefficient (ADC) values for a 1.5T Elekta Un...
Authors: Niki Fitousi, Stanley Thomas Fricke, Anna Romanyukha
Affiliation: Qaelum NV, Children's National Hospital
Abstract Preview: Purpose:
To identify opportunities for improvement through investigation of outliers in exam dose length product (DLP) and patients receiving high cumulative doses (CED), in the context of our âped...
Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka
Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...
Authors: Ben Piacitelli, Celeste Winters
Affiliation: OHSU, Department of Diagnostic Radiology, Oregon Health & Science University
Abstract Preview: Purpose: To compare recovery coefficients measured with Lu-177 and Tc-99m with the goal of assessing accuracy of the Tc-99m surrogate method and comparing RC reproducibility between scanners of the sa...
Authors: Silvia Calusi, Lucia Cavigli, Alberto Dalla Mora, Laura Di Sieno, Giacomo Insero, Riccardo Lisci, Livia Marrazzo, Cosimo Nardi, Stefania Pallotta, Andrea Profili, Fulvio Ratto, Giovanni Romano, Michaela Servi, Immacolata Vanore, Yary Volpe
Affiliation: Italian National Research Council IFAC-CNR, Institute of Applied Physics, Department of Physics, Politecnico di Milano, Department of Agricultural Food and Forestry System, University of Florence, Medical Physics Unit, Azienda Ospedaliero-Universitaria Careggi, Department of Industrial Engineering, University of Florence, Department of Experimental and Clinical Biomedical Sciences âMario Serioâ, University of Florence
Abstract Preview: Purpose: To develop a multi-purpose lung phantom prototype to replicate respiratory dynamics and morphological features observed in clinical radiological (CT and MR) imaging of lung parenchyma.
Met...
Authors: Min Cheol Han, Jin Sung Kim, Seok Ho Lee, Gahee Son, Yongdo Yun
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: This study aims to develop the MC-DOLCE, a Monte Carlo (MC)-based system capable of calculating physical and biological dose distributions, as well as linear energy transfer (LET) distributio...
Authors: Huang Chi-Shiuan, Wu Chih-Chun, Hui-Yu Cathy Tsai, Chen Yan-Han, Chen Yi-Wei, Pan Yi-Ying
Affiliation: Institute of Nuclear Engineering and Science, National Tsing Hua University, Taipei Veterans General Hospital, Tri-Service General Hospital
Abstract Preview: Purpose:
This study aims to develop and validate a machine learning (ML) model based on MRI-derived radiomic features to predict progressive disease (PD) in glioblastoma (GBM) patients four months ...
Authors: Jin Sung Kim, Chanwoong Lee, Young Hun Yoon
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: Chest contrast-enhanced CT (CECT) serves as a valuable tool for cardiac imaging, but its lack of detailed anatomical visualization limits its utility in segmentation tasks. While CECT offers ...
Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar
Affiliation: University of Minnesota
Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...
Authors: Rachel B. Ger, Xun Jia, Youfang Lai, Todd R. McNutt, Xingyi Zhao
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University
Abstract Preview: Purpose: Radiotherapy (RT) plays an essential role for head and neck (HN) cancer treatment but often results in xerostomia due to salivary gland damage. It is important to mechanistically model the ra...
Authors: Andrew R. Godley, Steve B. Jiang, Mu-Han Lin, Austen Matthew Maniscalco, Dan Nguyen, Yang Kyun Park
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose:
Preparing DICOM datasets for research and education is challenging due to the complexity of the format and the necessity for patient-specific handling. Existing workflows demand substantia...
Authors: Mandar S. Bhagwat, Casey Y. Lee
Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...
Authors: Stephen R. Bowen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Jiajie Wang, Shouyi Wang, Faisal Yaseen, Han Zhou
Affiliation: Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington
Abstract Preview: Purpose: Predicting the effects of the spatial-temporal tumor response to chemoradiation can assist in adjusting radiation dose and support clinical decision-making in radiotherapy. A multi-instance l...
Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong
Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati
Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...
Authors: Smith Apisarnthanarax, Stephen R. Bowen, Sunan Cui, Jie Fu, Clemens Grassberger, Yulun He, Yejin Kim, Matthew J. Nyflot, Sharon Pai
Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Physics, University of Washington, University of Washington and Fred Hutchinson Cancer Center
Abstract Preview: Purpose: 99mTc-sulfur colloid SPECT imaging enables quantitative assessment of voxel-wise liver function in patients with hepatocellular carcinoma (HCC). Accurately predicting post-radiotherapy (RT) l...
Authors: Laurence Edward Court, Alexandra Olivia Leone, Zhongxing Liao, Saurabh Shashikumar Nair, Joshua S. Niedzielski, Ramon Maurilio Salazar, Ting Xu
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Radiation Pneumonitis (RP) predictive models often rely on clinical and DVH parameters, but multiomic features from CT imaging and 3D dose distributions from various regions could provide add...
Authors: Steve B. Jiang, Mu-Han Lin, Yu-Chen Lin, Austen Matthew Maniscalco, Dan Nguyen, David Sher, Xinran Zhong
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, UT Dallas
Abstract Preview: Purpose:
Sequential boost radiotherapy (RT) poses a challenge in allocating dose across multiple plans while protecting organs at risk (OARs). Clinicians must decide whether OAR sparing should occu...
Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard
Affiliation: Fibermetrix, Alara Expertise, Alara Group
Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...
Authors: Yeona Cho, Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Jihun Kim, Jin Sung Kim, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu
Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Memorial Sloan Kettering Cancer Center, Yonsei University
Abstract Preview: Purpose: We hypothesized that combining clinical, imaging, and radiotherapy dose-distribution features could increase predictive model accuracy in radiation-induced severe acute esophagitis (SAE) in e...
Authors: Samuel L. Brady, Shruti Hegde, Alexander Knapp, Usman Mahmood, Joseph G. Meier, Elanchezhian Somasundaram, Zachary Taylor
Affiliation: Cincinnati Children's Hospital Medical Ctr, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Cincinnati Children's Hospital Medical Center, Cincinnati Childrens Hospital Med Ctr
Abstract Preview: Purpose:
To assess how two benchmark multi-organ CT segmentation models respond to varying image noise levels.
Methods:
This study utilized the pediatric CT dataset from The Cancer Imaging Ar...
Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania
Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...
Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna
Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI
Abstract Preview: Purpose: To estimate effective doses associated with different imaging protocols for hip imaging with a cone beam CT (CBCT) scanner specifically designed for weight-bearing acquisitions.
Methods: A...
Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li, Junzhong Xu
Affiliation: Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiology, Vanderbilt University Medical Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cell size is a vital parameter in evaluating the tumor microenvironment, including cell apoptosis and radiotherapy(RT)-induced immune cell infiltration. The IMPULSED(Imaging Microstructural P...
Authors: Chih-Wei Chang, Junbo Peng, Richard L.J. Qiu, Justin Roper, Xiangyang Tang, Tonghe Wang, Huiqiao Xie, Xiaofeng Yang, David Yu
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Emory Univ, Emory University, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Limited-angle dual-energy (DE) cone-beam CT (CBCT) is considered a promising solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, ...
Authors: Xiaohu Li, Jianjun Shen, Guozhi Zhang, Sihua Zhong, Jingjie Zhou
Affiliation: United Imaging Healthcare
Abstract Preview: Purpose:
Visualization of carotid artery vessel wall on computed tomography angiography (CTA) imaging is challenging. This study aims to develop a novel post-processing technique, black-blood compu...
Authors: Zhihua Qi
Affiliation: Henry Ford Health
Abstract Preview: Purpose: State of the art cardiac CT has built-in automated, patient specific optimization, taking into account a number of factors including patient size, heart rate and others. It is crucial to deve...
Authors: NadÚge Anizan, David Broggio, Désirée Deandreis, Didier Franck, Camilo Garcia, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard
Affiliation: Gustave Roussy, Service de Physique Médicale, Institut Bergonié, Service de Physique Médicale, Gustave Roussy, Service de Médecine Nucléaire, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS
Abstract Preview: Purpose: This work aimed at developing an innovative workflow for 177Lu-PSMA personalized dosimetry to lesions and organs at risk (OAR) simultaneously, considering the cross-irradiation from bone meta...
Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq
Affiliation: Khalifa University
Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...
Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou
Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center
Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...
Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz
Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)
Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...
Authors: Ricardo Garcia Santiago, Narges Miri, Daryl P. Nazareth, Ankit Pant, Mukund Seshadri
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To develop a transformer-based deep learning network framework for predicting VMAT dose distributions. This can provide fast and efficient calculations with accuracies potentially comparable ...
Authors: Parham Alaei, Timothy J Allen, Tomas Agustin Montenegro
Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis
Abstract Preview: Purpose:
To assess possible relationships between treatment plan optimization parameters and gamma pass rates in quality assurance (QA) analysis of IMRT/VMAT plans.
Methods:
Plan optimization...
Authors: Qianxi Ni, Qionghui Zhou
Affiliation: The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University
Abstract Preview: Purpose:
This study aims to develop and evaluate interpretable machine learning models that use radiomic and dosimetric features to predict HT in advanced cervical cancer patients.
Methods:
R...
Authors: Ozan Cem Guler, William Silva Mendes, Sangbo Oh, Cem Onal, Lei Ren, Apurva Singh, Phuoc Tran
Affiliation: University of Maryland School of Medicine, Baskent University Faculty of Medicine, Department of Radiation Oncology, Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose: To predict metastasis-free survival (MFS) for patients with prostate adenocarcinoma treated with androgen deprivation therapy and external radiotherapy using clinical factors and radiomics ex...
Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells
Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...
Authors: Hua-Chieh Shao, You Zhang, Ruizhi Zuo
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cone-beam CT (CBCT) provides on-board patient anatomy for image guidance and treatment adaptation in radiotherapy. However, to compensate for respiration-induced anatomical motion, motion-res...
Authors: Paul J. Black, Jordan B Lunsford, James D. Ververs, India Wood
Affiliation: Atrium Health Wake Forest Baptist, Wake Forest University School of Medicine, Wake Forest School of Medicine
Abstract Preview: Purpose:
To develop a 3D-printed modular CT simulator phantom that allows the assessment of all AAPM TG-66 recommended monthly quality assurance (QA) tests.
Methods:
A modular CT simulator mo...
Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson
Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer
Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...
Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich
Affiliation: Rush University
Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...
Authors: Jeffrey S. Nelson, Raj Kumar Panta, Megan K. Russ, Ehsan Samei
Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Contrast-enhanced mammography (CEM) enhances tumor detection by utilizing energy-dependent information from iodinated contrast agents. However, there is a lack of quantitative techniques to a...
Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu
Affiliation: Mayo Clinic
Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)
Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...
Authors: Arezoo Modiri, Robabeh Rahimi, Akira SaiToh, Amit Sawant
Affiliation: Maryland University Baltimore, University of Maryland, University of Maryland in Baltimore, Department of Computer and Information Sciences, Sojo University
Abstract Preview: Purpose: It has been a longstanding challenge to optimize the daily schedule of radiation treatment rooms toward minimum patient wait times, efficient use of clinical staff and reduced running cost of...
Authors: Lars Ewell, Russell J. Hamilton
Affiliation: Banner University Medical Group, Bannerhealth
Abstract Preview: Purpose: To estimate the variability and predictability of radiation dose as a function of the planning target volume (PTV) size and the anatomical sites of head & neck, brain and prostate.
Methods...
Authors: Rico Castillo, Katherine Gonzalez, Casey C. Heirman, Kyle J. Lafata, Xiang Li, Yvonne M Mowery, Yvonne M Mowery, Allison Pittman, Ashlyn G. Rickard, Breylon Riley
Affiliation: Duke University, Department of Radiation Oncology, Duke University, University of Pittsburgh
Abstract Preview: Purpose: To evaluate the relationships between quantitative imaging biomarkers and chemoradiation resistance in head and neck squamous cell carcinoma (HNSCC) using preclinical mouse models.
Met...
Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma
Affiliation: RefleXion Medical
Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...
Authors: Keiichi Jingu, Noriyuki Kadoya, Takafumi Komiyama, Takeru Nakajima, Hikaru Nemoto, Hiroshi Onishi, Masahide Saito, Ryota Tozuka
Affiliation: Department of Radiology, University of Yamanashi, Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Department of Advanced Biomedical Imaging, University of Yamanashi
Abstract Preview: Purpose: We evaluated the accuracy of a new AI-based fully automated planning software in stereotactic body radiotherapy (SBRT) for early-stage lung cancer.
Methods: We collected data from 125 pati...
Authors: David P. Adam, Xun Jia, Youfang Lai, Yuncheng Zhong
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University
Abstract Preview: Purpose: Radiopharmaceutical therapy is experiencing a resurgence in interest due to its potential of treating widespread metastatic disease in a patient-specific manner. Accurately measuring and desc...
Authors: Emi Ai Eastman, Vu Nguyen, Alexander W. Scott, Lucien Zang, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose:
Three key features were developed to substantially improve a previously in-house developed CT protocol website: a structured backend for efficient protocol creation and edit; the ability t...
Authors: Diandra Ayala-Peacock, Junzo Chino, Oana I. Craciunescu, Allison Jones, Kyle J. Lafata, Kim Light, Sheridan G. Meltsner, Jack B Stevens
Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke University Medical Center
Abstract Preview: Purpose: This study aims to develop an MR-based method that retrospectively correlates longitudinal changes in morphology and physiology for the bulboclitoris and vaginal canal with dose received duri...
Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira
Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center
Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...
Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang
Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...
Authors: Tatsuya Fujisaki, Hiraku Fuse, Shin Miyakawa, Hiroki Nosaka, Masato Takahashi, Kenji Yasue
Affiliation: Ibaraki Prefectural University of Health Sciences
Abstract Preview: Purpose: This study aimed to evaluate the robustness of Jacobian-based and HUchange-based CT ventilation imaging (CTVI) against respiratory amplitude variations using a custom-designed alveolar phanto...
Authors: Carl D. Elliston, Lawrence Koutcher, Michael J. Price, Adam C. Riegel, Michael B Sisti, Tony J.C. Wang, Andy (Yuanguang) Xu
Affiliation: Columbia University Irving Medical Center
Abstract Preview: Purpose: An inverse treatment planning software was recently introduced to Gamma Knife radiosurgery. The purpose of this study is to compare the plan quality of the Gamma Knife âLightningâ with that o...
Authors: Hilary Louisa Byrne, Paul J. Keall, John Kipritidis, Jeremy Lim
Affiliation: Northern Sydney Cancer Centre, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney
Abstract Preview: Purpose:
Non-contrast CT ventilation imaging (CTVI) has been developed as a cost-effective and accessible alternative to PET/SPECT V/Q imaging for visualizing lung function. However, the sensitivit...
Authors: Joseph Barbiere, Joseph Hanley, Brett Lewis, Jay Mistry, Alois M. Ndlovu, Roland Teboh
Affiliation: Hackensack University Medical Center, HUMC, Jersey Shore University Medical Center
Abstract Preview: Purpose:
Quantitative PET-CT can evaluate clinical response to radiotherapy. For tumors less than approximately 3cm partial volume effects due to the poor PET resolution makes accurate measurement ...
Authors: Li-Sheng Geng, David Huang, Haoze Li, Xi Liu, Meng Wang, Tianyu Xiong, Ruijie Yang, Weifang Zhang, Meixin Zhao
Affiliation: School of Physics, Beihang University, Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, Peking University Third Hospital, Department of Nuclear Medicine, Peking University Third Hospital, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: This study aimed to develop a deep learning-based framework for simultaneously generating lung perfusion and ventilation images from three-dimensional computed tomography (3D CT) images.
M...
Authors: Hadley Anna DeBrosse, Kevin J. Little
Affiliation: The Ohio State University
Abstract Preview: Purpose: This work examines the consistency and pattern of spatial resolution degradation in weekly quality control (QC) testing prior to CT tube failure and replacement and investigates potential cor...
Authors: Liyuan Chen, Sepeadeh Radpour, David Sher, Jing Wang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center
Abstract Preview: Purpose: Accurate lymph node malignancy prediction is pivotal in optimizing radiation treatment strategies for head and neck (HN) cancer patients. While conventional radiomics models leverage intensit...
Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: Filament deposition modeling (FDM) 3D printers may utilize proprietary calibration methods inadequate for medical imaging. Proper techniques are necessary to achieve imaging uniformity standa...
Authors: Jennifer Kwak, Chelsea Manica, Justin K. Mikell, Michael Silosky, Wendy Siman
Affiliation: Washington University School of Medicine in St. Louis, University of Colorado Anschutz Medical Campus, School of Medicine, Rocky Vista University
Abstract Preview: Purpose:
This study evaluates synthetic planar imaging (synP) from SPECT projections against conventional planar imaging, focusing on detectability, spatial resolution, and feasibility. SynP allows...
Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...
Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose:
This work demonstrates how existing software, when creatively adapted, can address a wide range of clinical challenges. By focusing on data exploration and application-specific modificatio...
Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu
Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center
Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...
Authors: Ă sa K. Carlsson Tedgren, Taran Hellebust, Antonio Herreros, Jacob Johansen, Christian Kirisits, Panagiotis Papagiannis, Mark J. Rivard, Frank-Andre Siebert, Frank Verhaegen, Javier Vijande, Jan Wiersma, Marisol de Brabandere, Ruud van Leeuwen
Affiliation: UKSH, Campus Kiel, Klinik fĂŒr Strahlentherapie (Radioonkologie), Department of Oncology, The Norwegian Radium Hospital, Oslo University Hospital, Radiation Physics, Department of Medicine and Health (IMH), Linköping University, Radiation Oncology Department, Hospital ClĂnic-Universitat de Barcelona, IDIBAPS, IFIC-UV, Radiation Oncology, Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Radboud University Medical Center, Department of Oncology, Aarhus University Hospital, University Hospital Gasthuisberg, Dept. of Radiation Oncology, Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Department of Radiation Oncology (MAASTRO), GROW â School for Oncology and Reproduction, Maastricht University Medical Centre+, Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna, Warren Alpert Medical School of Brown University
Abstract Preview: Purpose: This study, which was carried out by the GEC-ESTRO BRAPHYQS working group, reports the increasing divergence between clinical reference air kerma rate (RAKR) measurements and vendor-provided ...
Authors: Yizheng Chen, Michael Gensheimer, Mingjie Li, Lei Xing
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose: Automatically translating non-contrast to contrast-enhanced computed tomography (CT) images is critical for improving clinical workflow, reducing heathcare cost, minimizing radiation exposure...
Authors: Wen C. Hsi, Tae Kyu Lee, Biniam Yo Tesfamicael
Affiliation: Allina Health, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Oklahoma Proton Center
Abstract Preview: Purpose: When minimal dose-variations induced by inter-fractional anatomical-changes and positioning-deviation were found for having limited impact on clinic-outcomes of oropharyngeal head-and-neck (H...
Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University
Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...
Authors: Jeremy S. Bredfeldt, Benito De Celis Alonso, Braian Adair Maldonado Luna, Kevin M. Moerman, Gerardo Uriel Perez Rojas, RenĂ© Eduardo RodrĂguez-PĂ©rez, Kamal Singhrao
Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Department of Mechanical Engineering, University of Galway, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla
Abstract Preview: Purpose: Online adaptive radiotherapy replanning for single-isocenter bone cancer metastasis treatment reduces on-table treatment time and patient discomfort compared to the multi-isocenter standard-o...
Authors: Matthew S Brown, John M. Hoffman, William Hsu, Grace Hyun Kim, Michael F. McNitt-Gray, Spencer Harrison Welland, Anil Yadav
Affiliation: Department of Bioengineering, UCLA, David Geffen School of Medicine at UCLA, UCLA Department of Radiology
Abstract Preview: Purpose: Non-contrast CT (NCCT) is frequently used in initial evaluation of suspected stroke to rule out intracerebral hemorrhage. Quantitative scoring systems like the Alberta Stroke Program Early CT...
Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...
Authors: Sara Allievi, Stefano Bonvini, Gloria Miori, Laura Orsingher, Andrea Passerini, Igor Raunig, Daniele Ravanelli, Erich Robbi, Annalisa Trianni
Affiliation: Department of Information Engineering and Computer Science, University of Trento, Vascular Surgery Department, S.Chiara Hospital, APSS, Medical Physics Department, S.Chiara Hospital, APSS
Abstract Preview: Purpose:
This study evaluates the performance of an AI-driven tool in segmenting and analyzing tissue composition in abdominal aortic aneurysm (AAA) patients, specifically focusing on the sealing z...
Authors: Aditya P. Apte, Joseph O. Deasy, Yusuf Emre Erdi, Anqi Fu, Johannes Hertrich, Andrew Jackson, Usman Mahmood, Jason Ocana, Trahan Sean, Amita Shukla-Dave
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Automated AI-based quantitative CT tools hold immense promise for advancing clinical decision-making, yet their reproducibility and generalizability remain vulnerable to variability in imagin...
Authors: Zijia Guo, Viktor Haase, Michael F. McNitt-Gray, Frederic Noo
Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA
Abstract Preview: Purpose: The attenuation values in CT hold strong potential for disease diagnosis. However, they lack reliability, which has limited their use to clinical trials where variability can be controlled. S...
Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.
Methods: A commercial rotational table (CDR EquilibriumÂź) is r...
Authors: Stephen R. Bowen, Shijun Chen, Chunyan Duan, Daniel S. Hippe, Qiantuo Liu, Qianqian Tong, Jiajie Wang, Shouyi Wang, Faisal Yaseen
Affiliation: The University of Texas at Austin, Tongji University, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Fred Hutchinson Cancer Center, University of Texas at Arlington
Abstract Preview: Purpose: Tumor subregion clustering and prediction of region-specific response can augment assessments and adaptive treatment decisions. A modeling framework was constructed to predict chemoradiation ...
Authors: Renxin Chu, Jelena Mihailovic, Kai Yang, Lifeng Yu, Da Zhang
Affiliation: Massachusetts General Hospital, Mayo Clinic, Boston Children's Hospital, UVA Health University Hospital, University of Missouri Health Care
Abstract Preview: Purpose:
A frequently used method to estimate effective dose (ED) in CT is by multiplying the dose length product (DLP) by a conversion factor, known as k-factor. The k-factor in this method is sus...
Authors: Jie Deng, Yunxiang Li, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Magnetic Resonance Imaging (MRI) has exceptional soft tissue contrast and an essential role in radiotherapy. The introduction of clinical MR-LINACs has enabled adaptive radiotherapy (ART) usi...
Authors: Shira Abraham, Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Phillip G. Lichtenwalner, Chuan Zeng, Pengpeng Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose:
We have developed a tool that uses deformable image registrations to perform deformable dose accumulation. In this work we evaluate use of this tool for adaptive head and neck dose accumul...
Authors: Minsong Cao, Amar Kishan, Dylan P. O'Connell, Jonathan Pham, Michael Steinberg, Luca F Valle, Michael Xiang
Affiliation: Department of Radiation Oncology, University of California, Los Angeles
Abstract Preview: Purpose: To evaluate bladder ultrasound as a surrogate for estimating on-table bladder volume in prostate cancer patients undergoing stereotactic body radiation therapy (SBRT). The study aimed to asse...
Authors: Ozgur Ates, Chin-Cheng Chen, Chia-Ho Hua, Matthew J. Krasin, Thomas E. Merchant
Affiliation: St. Jude Children's Research Hospital
Abstract Preview: Purpose: To validate the use of synthetic CTs generated from CBCT images for online monitoring, ensuring accurate and reliable daily plan quality assessments in adaptive proton therapy (APT).
Metho...
Authors: Naruomi Akino, Kirsten Lee Boedeker, Ilmar Hein, Akira Nishikori, Daniel W Shin
Affiliation: Canon Medical Systems Corporation, Canon Medical Research USA
Abstract Preview: Purpose: To validate a simulation tool using physics-based image quality metrics in both phantom and patient data, and to assess the low contrast detectability (LCD) of Super Resolution-Deep Learning ...
Authors: Jae Won Jung, Choonsik Lee, Jason C. Mace, Sergio Morato Rafet
Affiliation: East Carolina University, Carilion Clinic, National Cancer Institute
Abstract Preview: Purpose: Dosimetry for radionuclides used in nuclear medicine can be accurately calculated if sufficient data is available. However, in most cases crucial information cannot or will not be known a pri...
Authors: Laura I. Cervino, Linda X. Hong, Jessica Pagan, Angelica A. Perez-Andujar, Maria Thor
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Memorial Sloan-Kettering Cancer Center
Abstract Preview: Purpose: Three-dimensional conformal radiotherapy (3DCRT) and Volumetric-Modulated Arc Therapy (VMAT) are used to treat locally advanced breast cancer. The 3DCRT treatment plans use the treatment fiel...
Authors: Duncan Henry Bohannon, Pretesh Patel, Sibo Tian, Yinan Wang, Xiaofeng Yang, Ahmal Jawad Zafar, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose:
4D robust optimization, incorporating additional images (e.g., maximum inhale/exhale phases), is commonly used to account for target motion in proton treatment planning. However, the incre...