Authors: John Paul Ortiz Bustillo, Elette Engels, Elrick T. Inocencio, Michael Lerch, Julia Rebecca D Posadas, Anatoly Rosenfeld, Kiarn Roughley, Moeava Tehei, Gordon Wallace, Danielle Warren, Vincent de Rover
Affiliation: Centre for Medical Radiation Physics, University of Wollongong Australia, Department of Radiology, University of the Philippines- Philippine General Hospital, Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, University of Wollongong Australia, Centre for Medical Radiation Physics, University of Wollongong, Intelligent Polymer Research Institute, ARC Centre of Excellence for Electromaterials Science, AIIM Facility, University of Wollongong, University of the Philippines Manila; Centre for Medical Radiation Physics, University of Wollongong Australia
Abstract Preview: Purpose: To compare the biological response through cell viability assay and fluorescence imaging of 3D bioprinted brain cancer (glioma) constructs relative to 2D monolayer and 3D spheroid culture for...
Authors: Odunola Grace Babawale, B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip, Jihyun Yun
Affiliation: Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute
Abstract Preview: Purpose: To evaluate the dose to a moving target and its surroundings in a magnetic field using 4D-Monte-Carlo (MC) simulation.
Methods: The study utilizes a previously validated MC model of our li...
Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo
Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...
Authors: Hao Gao, Yuting Lin, Nimita Shinde, Weijie Zhang
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: LATTICE, a form of spatially fractionated radiation therapy (SFRT), delivers high-dose peaks and low-dose valleys to the target volume and has been clinically used for large target volumes. H...
Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu
Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...
Authors: Hao Gao, Xue Hong, Harold Li, Yuting Lin, Jufri Setianegara, Xin Tong, Chao Wang, Weijie Zhang, Ya-Nan Zhu
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Lattice radiotherapy (LATTICE) is a form of spatially fractionated radiation therapy (SFRT) designed to deliver high radiation doses to specific tumor regions (vertices) while sparing surroun...
Authors: Lei Xing, Zixia Zhou
Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University, Stanford
Abstract Preview: Purpose: Functional brain imaging techniques, such as functional magnetic resonance imaging (fMRI), generate high-dimensional, dynamic data reflecting complex neural processes. However, extracting rob...
Authors: David J. Gladstone, P. Jack Hoopes, David I Hunter, Brian W Pogue, Jacob Pierce Sunnerberg, Armin Tavakkoli
Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Geisel School of Medicine, Dartmouth College
Abstract Preview: Purpose: The FLASH effect, characterized by normal tissue sparing under ultra-high dose rate (UHDR) radiation delivery, remains mechanistically unclear. This study investigated the relationship betwee...
Authors: Mahmoud H Abdelgawad, Shahabeddin mostafanazhad Aslmarand, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Teh Lin, Chang Ming Charlie Ma, Robert A. Price
Affiliation: Physics department, Faculty of science, Al-Azhar University, Fox Chase Cancer Center
Abstract Preview: Purpose: Many modern radiotherapy clinics are moving to online adaptive radiotherapy. A recent upgrade of the CBCT-based adaptive radiotherapy system introduced ultra-high-speed image acquisition. Thi...
Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao
Affiliation: The George Washington University, The George Washington University Cancer Center
Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa
Affiliation: National Cancer Centre Singapore
Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...
Authors: Michael Burke, David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Vanessa Hill, Ann-Teresa Jasman, John Kim, Svetlana Kuznetsova, MinYoung Lee, Daniel Longo, Henry S. Park, Adam Shulman, Lauren Tressel, Weili Zhong
Affiliation: Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose:
The complexity of biology-guided radiotherapy (BgRT), particularly with systems like RefleXion X1, necessitates robust pre-treatment quality assurance (QA) to ensure patient safety, treatm...
Authors: Joshua Misa, Damodar Pokhrel, William St. Clair
Affiliation: University of Kentucky, Department of Radiation Medicine
Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumorβs center, surrounded by smaller diameter spheres. W...
Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung
Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital
Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...
Authors: Akbar Anvari, Carnell J. Hampton, Melanie R. Piantino, Kai Yang
Affiliation: Levine Cancer Institute, Atrium Health
Abstract Preview: Purpose: To evaluate aperture collimation on a C-shape gantry-mounted proton accelerator. Mevion S250i Hyper scanning machine implemented aperture collimation utilizing adaptive aperture (AA). The AA ...
Authors: Anthony Hong Cheol Lim, Rayyan L Mahmood, Alexander Stanforth, Chris C. Wang, Mingyao Zhu
Affiliation: Georgia Institute of Technology, Emory University
Abstract Preview: Purpose: The purpose of this project is to test the feasibility of proton minibeam lattice radiotherapy within an existing clinical setting.
Methods:
The TOPAS code is used to model a scenario i...
Authors: Wen C. Hsi, Kayla Schneider
Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Measurement-based patient-specific quality-assurance (PSQA) conducted with a 2D dosimeter to verify delivered dose of each field over 3 measurement-depths is time-consuming with limited se...
Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles
Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...
Authors: Ben Durkee, Renata Farrell, Carri K. Glide-Hurst, Colin Harari, Alex Singleton Kuo, Chase Ruff, Jordan M. Slagowski, Yuhao Yan
Affiliation: University of Wisconsin, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: Advances in upright CT and patient positioning system now enables high quality daily CT imaging and treatment delivery in the upright position, providing benefits including reduced internal m...
Authors: Bingqi Guo, Ping Xia
Affiliation: Cleveland Clinic
Abstract Preview: Purpose:
Spatially fractionated radiation therapy (SFRT) delivers a βGRIDβ or βlatticeβ of high and low doses to tumors to increase tumor control, minimize normal tissue damage, and preserve the im...
Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.
Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...
Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler
Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC
Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...
Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Delivery efficiency and robustness are critical in spot-scanning proton arc therapy (SPAT), yet the conventional use of redundant energy layers (ELs) prolongs switching times and reduces effi...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Sarah E. McKenney, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose:
While wide coverage (160 mm) CT scanners can image whole organs (e.g. heart, brain, kidneys, etc.) in one axial scan, the peripheral regions of the field of view (along z) suffer from cons...
Authors: Jason Ellsworth, Mark Mishra, Jason K Molitoris, Lei Ren, Dario B. Rodrigues, Paul Turner, Graeme Woodworth
Affiliation: University of Maryland School of Medicine, Department of Neurosurgery, University of Maryland School of Medicine, University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Pyrexar Medical
Abstract Preview: Purpose: Hyperthermia therapy (HT) involves increasing tumor temperatures to 40-44Β°C and is a potent radio- and chemosensitizer for treating solid tumors. Current clinical strategies to heat deep-seat...
Authors: James L. Giltz, Michael J. Merrick
Affiliation: Alyzen Medical Physics, University of Kentucky
Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...
Authors: Muhammad Ramish Ashraf, Dixin Chen, Aaron Garza, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner, Murat Surucu
Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: FLASH radiotherapy, supported by robust preclinical evidence showing an improved therapeutic index, is advancing toward clinical trials. Clinical FLASH treatments will likely require scanning...