Search Submissions 🔎

Results for "density tissues": 47 found

A Multimodal CAD System for Breast Cancer Detection: Integrating MRI, DBT, and Mammography for Dense Breast Challenges

Authors: Si-Wa Chan, Yuan-Yu Lee, Zhi-Ying Li, Jia-Wei Liao, Hui-Yu Cathy Tsai

Affiliation: Department of Radiology, Taichung Veterans General Hospital​, Institute of Nuclear Engineering and Science, National Tsing Hua University

Abstract Preview: Purpose: Dense breast tissue reduces the sensitivity of mammography, posing diagnostic challenges, especially for Asian women with high breast density (up to 50%). Current single-modality techniques o...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

A Practical Experimental Software Validation Method for Voxel-Based Personalised Dosimetry in Radiopharmaceutical Therapy

Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal

Affiliation: University Hospital Southampton

Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...

A Realistic Computer Simulation Study Assessing How Beam Hardening Affects the Accuracy of CT Lung Attenuation Values

Authors: Zijia Guo, Michael F. McNitt-Gray, Frederic Noo, Karl Stierstorfer

Affiliation: Siemens Healthineers, University of Utah, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose: Accurately assessing lung parenchyma health is critically important in the management of patients with chronic obstructive pulmonary disease. CT attenuation values are valuable for this purpo...

A Retrospective Assessment of Proton Radiation Response in Brain Tumor Patients Using Diffusion-Weighted MR Imaging

Authors: Liu Hong, Wen C. Hsi, Faraz Kalantari, Romy Megahed, Ganesh Narayanasamy, Maida Ranjbar, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: Quantitative apparent diffusion coefficients (ADC) in diffusion-weighted MRI (dMRI) reflect water diffusivity and thus provide tissue cellular density information. Functional diffusion mappin...

Absorption and Material Property Characteristics of 3D-Printing Filaments Based on Monte-Carlo Simulations and Spectral Imaging

Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon

Affiliation: University of Florida College of Medicine, University of Florida

Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...

Accelerated Proton Density Imaging Via T2-Guided Cyclegan Super-Resolution without Paired Low-Resolution and High-Resolution Data

Authors: Yunxiang Li, Xinlong Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Acquiring high-resolution (HR) proton density (PD) images is time-consuming, while lower-resolution (LR) PD scans are faster but can lack sufficient details. We propose CycleHR, a T2-contrast...

Advancing Magnetic Resonance Imaging (MRI) Safety Clearance: Utilizing Dual-Energy CT (DECT) Material Decomposition for Foreign Object Assessment

Authors: Anzi Zhao

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: This study investigates the utility of Dual-Energy Computed Tomography (DECT) material decomposition in resolving Magnetic Resonance Imaging (MRI) safety concerns for patients with unidentifi...

An Adjustable Wool Fiber Phantom for Investigating the Detection of Anisotropy with Ultrasound Speckle Statistics

Authors: Alexandra Christensen, Timothy J. Hall, Ivan M. Rosado-Mendez

Affiliation: University of Wisconsin, Madison, Departments of Medical Physics and Radiology, University of Wisconsin-Madison

Abstract Preview: Purpose: Quantitative ultrasound techniques based on the statistical analysis of speckle are currently being deployed commercially and clinically as sources of biomarkers associated with tissue micros...

Analysis of Orthopedic Metal Artifact Reduction’s (O-MAR’s) Effectiveness on Correcting Typical Anatomical Structure Average Volumetric Hounsfield Unit (AVHU) Values Due to High-Density Metal Artifacts

Authors: John T Barrett, Mehnaz Haque, Chulhaeng Huh, Shands James, Thomas B. Lavin, Anobel Maghsoodpour, Farshad Mostafaei, Austin Sanders

Affiliation: Department of Radiation Oncology, Augusta University, Department of Radiation Oncology, Medical College of Georgia, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health, Department of Radiation Oncology, Doctors Hospital of Augusta, Department of Radiology and Imaging, Augusta University

Abstract Preview: Purpose: This study assesses Philips’ O-MAR effectiveness in adjusting AVHU values of common anatomical materials affected by various high-density metal artifacts at varying distances.

Methods:...

Anatomical Noise Power Exponent (β) As an Image-Based Risk Factor for Breast Cancer

Authors: Yile Fang, Leslie Lamb, Nathaniel David Mercaldo, Kai Yang

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: To quantitatively evaluate power-law exponent β as a potential image-based breast cancer risk factor.

Methods: Two groups of breast cancer screening cohorts (target vs. control, 20 sub...

Assessment of the Dosimetric Characteristics of Brass Mesh Bolus in Electron Radiation Therapy

Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser

Affiliation: Christiana Care

Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...

Assessment of the Radiological Features of 3D-Printed Polylactic Acid Composites for Creating Personalized Dosimetric Phantoms

Authors: Ashish Binjola, Raj Kishore Bisht, Natanasabapathi Gopishankar, Pratik Kumar, Daya Nand Kishore Sharma, Sukhvir Kishore Singh, Subramani Vellaiyan

Affiliation: Medical Physics Unit, All India Institute of Medical Sciences, All India Institute of Medical Sciences, Department of Radiological Safety, Institute of Nuclear Medicine and Allied Sciences, Department of Radiation Oncology, All India Institute of Medical Sciences

Abstract Preview: Purpose: Additive manufacturing is increasingly being explored to create dosimetry phantoms. Commercial anthropomorphic phantoms represent an average patient and lack anatomical variations due to obes...

BEST IN PHYSICS IMAGING: Dosimetric Impact of Iodinated Contrast Agent on Fibroglandular Tissue in Contrast-Enhanced Digital Mammography

Authors: Hannah Grover, Andrew J. Sampson

Affiliation: Oregon Health & Science University, UT Health San Antonio

Abstract Preview: Purpose: The goal of this work was to quantify the dosimetric impact of iodinated contrast on fibroglandular breast tissue to better inform clinical risk and benefit assessments when determining the m...

BEST IN PHYSICS MULTI-DISCIPLINARY: Building a Cross-Modality Model to Integrate Bio-Clinical Features, Anatomical MRI, and White-Matter Pathlength Mapping for Personalized Glioblastoma RT Planning

Authors: Steve Braunstein, Angela Jakary, Hui Lin, Bo Liu, Janine Lupo, Tiffany Ngan, Ke Sheng, Nate Tran

Affiliation: Radiation Oncology, University of California San Francisco, Graduate Program in Bioengineering, University of California San Francisco-UC Berkeley, Department of Radiation Oncology, University of California San Francisco, Department of Radiology and Biomedical Imaging, University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: Current RT clinical target volumes (CTVs) for Glioblastoma (GBM) employ 2cm isotropic expansions of gross tumor volumes. However, studies showed patients still experience progression beyond t...

Beyond Correlation: An Ultra-Large Physics-Driven Vascularized Tumor Model to Bridge Feature Formation with Underlying Biology

Authors: Jiayi Du, Lihua Jin, Ke Sheng, Yu Zhou

Affiliation: Harvard University, University of California, San Francisco, UCLA, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: Radiomics enables powerful insights into tumor biology through non-invasive imaging, excelling in diagnostic and prognostic predictions. However, due to a lack of mechanistic connections, que...

Black Bone MRI As a Surrogate for CT to Detect Intensity Differences in Mandible Sub-Volumes

Authors: Cem Dede, Clifton David Fuller, Renjie He, Laia Humbert Vidan, Stephen Y. Lai, Amy Moreno, Mohamed Naser, Kareem Abdul Wahid, Natalie A West

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Head and neck cancers (HNC) treated with radiation therapy can result in radiation-induced bone injury. In CT, changes in radiodensity correlate to changes in bone integrity. Most studies use...

Commissioning Silicone Tissue-Compensating Bolus for Electron Beam Therapy

Authors: Carla D. Bradford, Linda Ding, Yansong Geng, Alan Hartford, I-Lin Kuo, Salvatore LaRosa, Joshua N Wancura

Affiliation: University of Massachusetts Chan Medical School

Abstract Preview: Purpose: When treating nasal skin cancers, electron beam radiotherapy dose distributions can be improved by using custom bolus to compensate for uneven surfaces. Here we describe our experience commis...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Cross-Calibration and Comparison of CT Number to Electron Density Using Two Calibration Phantoms

Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...

Cross-Calibration of CT Number to Electron and Physical Density: Feasibility of Using Diagnostic Scans for Treatment Planning

Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...

Development of a Novel 3D-Printed Heterogeneous Phantom for Liver SBRT Dose Verification in Hepatocellular Carcinoma (HCC) Treatment.

Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav

Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)

Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...

Dosimetric Comparison of 6X and 10X Flattening Filter-Free Photon Beams on a Truebeam Linac Using the Eclipse TPS

Authors: Carlos E. Cardenas, Udbhav S. Ram, Marcin Wierzbicki

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham, Juravinski Cancer Centre

Abstract Preview: Purpose:
This study aims to systematically evaluate the dosimetric properties and delivery efficiency of 6X-FFF and 10X-FFF beams for lung SBRT on the Varian TrueBeam STx using the Eclipse TPS 16.1...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Evaluating the Capabilities of Hypersight CBCT for Advanced Dual-Energy CBCT Imaging in Online Adaptive Radiotherapy

Authors: Yi-Fang Wang, Yading Yuan

Affiliation: Columbia University Irving Medical Center, Department of Radiation Oncology, Columbia University Irving Medical Center

Abstract Preview: Purpose: HyperSight, the latest CBCT technology from Varian Medical Systems, integrates rapid 6-second data acquisition with advanced iterative reconstruction and upgraded hardware. Previous studies h...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

FMEA for Direct to Unit Adaptive Radiotherapy

Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert

Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis

Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

First in-Vivo Application of a Novel Precision Small Animal Irradiation Platform with Proton IMPT Delivery and Advanced on-Board Image-Guidance

Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf

Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital

Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...

Impact of Serial Passage on Radiation Response and Angiogenic Activity in Head and Neck Cancer Patient-Derived Xenografts

Authors: Liliana Berube, Randall J Kimple, Kwangok P Nickel, Hannah Sondreal

Affiliation: UW Madison

Abstract Preview: Purpose: The fidelity of patient-derived xenografts (PDXs) is crucial for their application in translational research, as it ensures that these models accurately retain the properties of the original ...

Impact of Tissue Heterogeneity on Proton LET and RBE Distributions: A Monte Carlo Study

Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences

Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...

Improvements from Monte Carlo Simulations over Pencil Beam Algorithms for Normal Tissue Dose Reconstruction in Proton Therapy Patients

Authors: Amy Berrington de Gonzalez, Keith T Griffin, Jae Won Jung, Cari M Kitahara, Choonik Lee, Choonsik Lee, Aimee L McNamara, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: University of Michigan, East Carolina University, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy dose reconstruction enables retrospective epidemiological studies that connect late health effects to the organ-absorbed radiation doses received during treatment. Though clinica...

Longitudinal Assessment of Normal Lung Radiosensitivity to Individualize Reirradiation

Authors: Smith Apisarnthanarax, Clemens Grassberger, John Kang, Yejin Kim, Justin Leu, Dominic A. Maes, Matthew J. Nyflot, Ramesh Rengan, Annemarie Shepherd, Jing Zeng

Affiliation: Department of Radiation Oncology, University of Washington and Fred Hutchinson Cancer Center, Department of Radiation Oncology, University of Washington, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington and Fred Hutchinson Cancer Center

Abstract Preview: Purpose: Reirradiation (ReRT) is a rapidly growing clinical challenge driven by better systemic therapy and longer survival, though clear guidelines for ReRT are lacking. Fitting traditional normal ti...

Lung Mass Variability in Clinical Chest CT Imaging with Automatic Contouring Tool

Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez

Affiliation: University of Houston, UT MD Anderson Cancer Center

Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...

Material Modulated 3D Printed Human-Tissue Simulant Phantoms for Radiation Therapy Modeling and Safety

Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar

Affiliation: University of Minnesota

Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...

Multiparametric and Low-Field MRI for Biomimetic MRI-Readable Gel Dosimeters

Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek

Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster

Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...

Photon Counting CT Method for Accurate Effective Atomic Number and Electron Density Measurement

Authors: Mohammed Alzaabi, Abderaouf Behouch, Nabil Maalej, Aamir Raja, Briya Tariq

Affiliation: Khalifa University

Abstract Preview: Purpose: Spectral Photon Counting CT (SPCCT) has emerged as a transformative technology in CT imaging capable of producing images from distinct energy windows, allowing improved material characterizat...

Photon-Counting CT for Estimation of Quantitative Information for Radiation Therapy Treatment Planning: Assessment of Scanning Conditions and Phantom Sizes

Authors: Carina Gassner, Guyue Hu, Thomas Kröncke, Christopher Kurz, Guillaume Landry, Katharina Niepel, Katia Parodi, Franka Risch, Florian Schwarz

Affiliation: Department of Radiation Oncology, LMU University Hospital, LMU Munich, Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)

Abstract Preview: Purpose: To evaluate the performance of a clinical photon-counting CT (PCCT) scanner in terms of proton relative stopping power (RSP) estimation using PCCT data and to compare the impact of different ...

Poisson Decay in Pharmacokinetics with Imaging in Targeted Alpha Therapy

Authors: Lars R Furenlid, Chiao Huang, Matthew A. Kupinski, Brian W. Miller

Affiliation: University of Arizona, Departments of Radiation Oncology and Medical Imaging, University of Arizona

Abstract Preview: Purpose: To sample random numbers of decay of radiotracers in a pharmacokinetic compartment model for Monte-Carlo simulation of imaging in targeted alpha therapy.
Methods: Time-activity curves (TAC...

Population Level Robustness Evaluation for Establishment of Benchmarks for Optimized Plans for Prostate Proton Therapy

Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey, Taylor Ransom

Affiliation: Thompson Proton Center, University of Tennessee

Abstract Preview: Purpose: Proton pencil beam scanning can reduce normal tissue dose but is highly sensitive to setup, anatomical changes, and range variations. These uncertainties may compromise target coverage and or...

Quantitative Assessment of Iodine Detectability As a Function of Tissue Density, Thickness and Dose in Contrast-Enhanced Mammography

Authors: Jeffrey S. Nelson, Raj Kumar Panta, Megan K. Russ, Ehsan Samei

Affiliation: Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Contrast-enhanced mammography (CEM) enhances tumor detection by utilizing energy-dependent information from iodinated contrast agents. However, there is a lack of quantitative techniques to a...

Radiochemical Monte Carlo Model to Investigate the Oxygen Impacts on Radical Yields Under Proton Flash Irradiation

Authors: Yao Hao, Yuting Peng, Francisco Javier Reynoso, Tianyu Zhao, Xiandong Zhao

Affiliation: Varian, University of South Florida, Washington University School of Medicine, Washington University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose: Ultra-high dose-rate (FLASH) dose rate (> 40 Gy/s) may result in a radio-protective effect in healthy tissue compared with conventional dose rate (CDR). This effect has been observed in vivo ...

Structure-Based Diffusion Model for CT Synthesis from MR Images for Radiotherapy Treatment Planning

Authors: Samuel Kadoury, Redha Touati

Affiliation: Polytechnique Montréal

Abstract Preview: Purpose:
Generating synthetic CT images from MR acquisitions for radiotherapy planning allows to integrate soft tissue contrast alongside density information stemming from CT, thus improving tumor ...

Universal MR-to-Synthetic CT: A Streamlined Framework for MR-Only Radiotherapy Planning

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose:
Converting MR images to synthetic CT (MR2sCT) is highly desirable as it streamlines the radiotherapy treatment planning workflow. This approach leverages the superior soft tissue visibilit...

Validation of Updated CT-to-SPR Calibration Method with Icrp-145 Data for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Soorim Han, Chan Hyeong Kim, Jin Sung Kim, Seok-Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The stoichiometric calibration method proposed by Kanematsu et al. (2016) has been widely adopted for CT number to stopping-power ratio (SPR) conversion in carbon-ion radiotherapy. With the r...

Virtual Monoenergetic Imaging for Radiotherapy: A Single CT Acquisition for Both Target Delineation and Dose Calculation

Authors: Harold Y Hu, Yanle Hu, Shuai Leng, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Basis Scottsdale, Mayo Clinic

Abstract Preview: Purpose: Radiotherapy CT simulation often requires two scans: a non-contrast scan for dose calculation and a contrast-enhanced scan for target delineation. Photon-counting-detector (PCD) CT allows the...

Weak-to-Strong Generalization for Interpretable Deep Learning-Based Histological Image Classification Guided By Hand-Crafted Features

Authors: Mark Anastasio, Zong Fan, Hua Li, Changjie Lu, Lulu Sun, Xiaowei Wang, Zhimin Wang, Michael Wu

Affiliation: University of Illinois at Urbana-Champaign, University of Illinois at Chicago, Washington University School of Medicine, University of Illinois Urbana-Champaign, Washington University in St. Louis, University Laboratory High School

Abstract Preview: Purpose: Histological whole slide images (WSIs) are vital in clinical diagnosis. Although deep learning (DL) methods have achieved great success in this task, they often lack interpretability. Traditi...