A Diffusion-Based AI Framework for Continuous Deformable Image Registration and Time-Resolved Dynamic CT Generation

Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Gregory Szalkowski, Qingying Wang, Kangning Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Respiratory motion management is crucial for accurate radiation delivery to moving targets while protecting healthy tissue, relying on time-resolved volumetric imaging and continuous deformab...

A Multi-Agent Approach for Fully Automated Nephrometry Feature Extraction in CT

Authors: Matthew S Brown, Joshua Genender, John M. Hoffman, Gabriel Melendez-Corres, Muhammad W. Wahi-Anwar

Affiliation: David Geffen School of Medicine at UCLA, UCLA Department of Radiology

Abstract Preview: Purpose: Renal lesions are evaluated using scoring systems based on visual assessments and manual measurements. The purpose of this work is to develop a multi-agent system for automated anatomic landm...

Advocating for Survival Prediction Models in Risk Stratification for Cancer Treatment Outcomes

Authors: Meixu Chen, Jing Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: Cancer treatment outcome prediction plays a pivotal role in guiding therapeutic decisions and optimizing patient care. Traditionally, binary prediction models have been widely used for risk s...

Deep Learning-Based Segmentation Using Cine Epid Images for Real-Time Tumor Monitoring

Authors: Fumiaki Komatsu, Shunsuke Moriya, Ryosuke Nakamura, Takeji Sakae, Toshiyuki Terunuma, Tetsuya Tomita

Affiliation: Graduate School of Comprehensive Human Sciences, University of Tsukuba, Institute of Medicine, University of Tsukuba, Proton Medical Research Center, University of Tsukuba, Department of Radiology, University of Tsukuba Hospital

Abstract Preview: Purpose: To develop a deep learning (DL) model capable of accurately tracking lung tumors independent of beam angle variations.
Methods: A thoracic dynamic phantom simulating lung motion in the sup...

Design and Construction of a Geometrical and Head Phantom with Internal Carotid Inserts for Flow Simulation in Image-Derived Input Function with 3T and 7T MR-Brainpet Insert Studies.

Authors: Dirk Grunwald, Hans Herzog, Hidehiro Iida, N. Jon Shah, Usman Khalid, Manfred Lennartz, Philipp Lohmann, Ceren Memis, Tobias Meurer, Claudia Regio Brambilla, Jürgen Scheins, Lutz Tellmann, Christoph W. Lerche, Martin Wiesmann, Karl Ziemons

Affiliation: FH Aachen University of Applied Sciences, Department of Chemistry and Biotechnology, Clinic for Diagnostic and Interventional Neuroradiology, Uniklinik Aachen,, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH, Institute of Neuroscience and Medicine (INM-4), Forschungszentrum Jülich GmbH,, Central Institute for Engineering, Electronics and Analytics (ZEA-1), Forschungszentrum, Turku PET Center, Institute of Biomedicine, Faculty of Medicine, University of Turku,

Abstract Preview: Purpose: Quantitative brain studies with positron emission tomography (PET) often require an arterial input function (AIF), which traditionally requires arterial cannulation. However, this is invasive...

Efficient Denoising of Low-Statistic Influence Matrices Using a Diffusion Transformer-Based Framework for Adaptive Proton Therapy

Authors: Yuzhen Ding, Hongying Feng, Jason Michael Holmes, Baoxin Li, Wei Liu, Daniel Ma, Lisa McGee, Samir H. Patel, Jean Claude M. Rwigema, Sujay A. Vora

Affiliation: Arizona State University, Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose:
Intensity-modulated proton therapy (IMPT) is a preferred treatment modality for head and neck (H&N) cancer patients, offering precise tumor targeting while sparing surrounding organs at ri...

Evaluation of AI-Generated Synthetic 4DCT from 3DCT for Radiotherapy Planning

Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin

Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center

Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...

Follow-the-Leader Framework for Adaptable Target Segmentation in Radiotherapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study introduces a novel template-guided deep learning framework for primary gross tumor volume (GTVp) segmentation, addressing challenges posed by diverse tumor types and enabling a uni...

Intraoperative Dynamic Contrast-Enhanced Fluorescence Imaging in Quantifying Tissue Perfusion of Amputation Patients

Authors: Logan M. Bateman, Xu Cao, Jonathan T. Elliott, Lillian A. Fisher, Ida Leah Gitajn, Xinyue Han, Eric R. Henderson, Shudong Jiang, Jessica M. Sin, Yue Tang

Affiliation: Dartmouth College, Dartmouth-Hitchcock Medical Center

Abstract Preview: Purpose: Adequate tissue perfusion is essential for fracture healing and infection prevention, as it supplies oxygen, nutrients and antibiotics to the injury area. However, current methods of assessin...

Moving Away from Measuring Everything - Implementing 3D Recalculation in a Large Networked Radiotherapy Institution to Replace Routine IMRT / VMAT QA

Authors: Eujin Chan, Christopher Colyer, Leon F Dunn, Jonathan Dunning, Michael Grace, Onno Kamst, Alex Livingstone, Thulani Nyathi, Vladimir Sashin, Philip Satory, Hilmar Schachenmayr, Brindha Subramanian, Lindsay J. Tremethick, Luke Webb

Affiliation: GenesisCare

Abstract Preview: Purpose: The purpose of this work is to outline the methodology and results from the implementation of a 3D recalculation software to replace IMRT/VMAT PSQA measurement across a large, networked radio...

Multimodal Framework for Predicting Radiation-Induced Severe Acute Esophagitis in Esophageal Cancer

Authors: Yeona Cho, Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Jihun Kim, Jin Sung Kim, Nikhil Mankuzhy, Aneesh Rangnekar, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Gangnam Severance Hospital, Yonsei University College of Medicine, Memorial Sloan Kettering Cancer Center, Yonsei University

Abstract Preview: Purpose: We hypothesized that combining clinical, imaging, and radiotherapy dose-distribution features could increase predictive model accuracy in radiation-induced severe acute esophagitis (SAE) in e...

Performance of Photon Counting Detector in a Clinical PCD-CT: A Novel Image-Based Evaluation

Authors: Frank F. Dong, Megan C. Jacobsen, Ke Li, Xinming Liu, John Rong

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose: We aimed to understand the physical performance of a CdTe PCD-based detector system within a whole-body PCD-CT scanner, with the goal of optimizing its clinical application. Instead of relyin...

Personalized Organ Dose Estimation Using Monte Carlo Simulations, Auto-Segmentation, and Anatomical Extension from Clinical CT Scans

Authors: Belen Juste, Choonsik Lee, Matthew Mille, Rafael Miró, Sergio Morato Rafet, Agustin Santos, Gumersindo Verdú

Affiliation: Division of Cancer Epidemiology and Genetics, National Cancer Institute, Universitat Politècnica de València, Servicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, National Cancer Institute

Abstract Preview: Purpose: To evaluate the differences in CT scan radiation dose estimation between personalized dose reconstruction, based on real patient CT images, and generalized phantom-based dose calculations.

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...