Search Submissions ๐Ÿ”Ž

Results for "derived site": 32 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

A Vision-Language Deep Learning Model for Predicting Survival Outcomes in Glioblastoma Patients

Authors: Zachary Buchwald, Chih-Wei Chang, Richard L.J. Qiu, Mojtaba Safari, Hui-Kuo Shu, Lisa Sudmeier, Xiaofeng Yang, David Yu, Xiaohan Yuan

Affiliation: Emory University and Winship Cancer Institute, Emory University, Georgia Institute of Technology, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: This study proposes a novel vision-language model (VLM) to predict survival outcomes in glioblastoma (GBM) patients. By integrating multimodal MRI data and clinical information, the proposed ...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

An Adaptive Radiotherapy Approach Sparing Preirradiated Critical Structures

Authors: Mohamed Bahaaeldin Mohamed Afifi, Lili Chen, Xiaoming Chen, Ahmed A. Eldib, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.

Abstract Preview: Purpose: Reirradiation of recurrent cancer or a newly developed lesion in a proximal location poses a challenge for radiation treatments. This is occasionally encountered in many modern clinics and ef...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Chat with Oncology Information System Via Large Language Model

Authors: Michael Dohopolski, Xuejun Gu, Hao Jiang, Steve B. Jiang, Christopher Kabat, Jingying Lin, Weiguo Lu, Michael Tang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Neuralrad LLC, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: To streamline access to clinical data stored in Oncology Information Systems such as MOSAIQ or ARIA, we developed an AI-powered chatbot capable of querying, summarizing, and interactively ans...

Clinical Validation of Fully Automated Script for Plan Conversion between Linacs with Different Mlc Model

Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin

Affiliation: NYU, NYU Langone Health

Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models

Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Conversion Coefficients from Hp(10) to Organ and Effective Doses for Medical Staff Involved in Fluoroscopically Guided Interventional Procedures

Authors: Stephen Balter, Haegin Han, Cari M Kitahara, Taeeun Kwon, Choonsik Lee, Martha S Linet, Donald L. Miller

Affiliation: Columbia University Medical Center, National Cancer Institute, Food and Drug Administration

Abstract Preview: Purpose: Staff in fluoroscopically guided interventional (FGI) procedures are exposed to radiation. Inhomogeneous radiation fields and variability in procedural conditions make it challenging to deriv...

Development and Evaluation of Fat Fraction Reference Materials for Magnetic Resonance Imaging

Authors: Hyo-Min Cho, Cheolpyo Hong, Changwoo Lee, Sunyoung Lee

Affiliation: Daegu Catholic University, Korea Research Institute of Standards and Science (KRISS), Korea Research Institute of Standards and Science

Abstract Preview: Purpose: With the increasing prevalence of metabolic syndrome, the importance of diagnosing obesity and fatty liver diseases has grown significantly. As a result, there is a rising demand for non-inva...

Dosimetric Parameter Cross-Check Evaluations for Dedicated Biologically-Guided Radiotherapy Linac Using Two Water Phantom Systems

Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...

Enhanced Pelvic Organ Segmentation Using LLM-Driven Prompts for Prostate Cancer Low-Dose-Rate Brachytherapy

Authors: Yang Lei, Tian Liu, Ren-Dih Sheu, Meysam Tavakoli, Jing Wang, Kaida Yang, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology, Emory University

Abstract Preview: Purpose:
The study aimed to improve target and organ at risk (OAR) segmentation in low-dose-rate brachytherapy (LDR-BT) for prostate cancer treatment, by integrating clinical guidelines into deep l...

Establishing a Protocol for Quality Assessment of Ultrasound Shear Wave Elastography (SWE) and Application to a Musculoskeletal (MSK) Task

Authors: Kevin M Brom, Jaydev K. Dave, Chunming Gu, Nicholas J. Hangiandreou, Zaiyang Long, Donald J Tradup

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Ultrasound scanner onboard quality checks for shear wave elastography (SWE) rely on operator judgement and are insufficient. This study aims to establish a protocol for quality assessment and...

Evaluating the Performance of Using Large Language Models to Automate Summarization of CT Simulation Orders in Radiation Oncology

Authors: Meiyun Cao, Edward L. Clouser, Xiaoning Ding, Jason Michael Holmes, Shaw Hu, Linda L. Lam, Wendy S. Lindholm, Wei Liu, Samir H. Patel, Diego Santos Toesca, Jason Sharp, Sujay A. Vora, Peilong Wang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Mayo Clinic Arizona, George Washington University

Abstract Preview: Purpose: In current clinical workflow of radiation oncology departments, therapists manually summarize CT simulation orders into summaries before the CT simulation for execution. This process signific...

Evaluation of Deformable Image Registration Accuracy Used in MR-Only Ventilation Mapping

Authors: Fei Han, James M. Lamb, Michael Vincent Lauria, Daniel A. Low, Tessa Elizabeth Maurer, Danilo Maziero, Claudia R. Miller, Drew Moghanaki, Louise Naumann, Nicolas Viot

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, Siemens Healthineers, UCLA, University of California Los Angeles

Abstract Preview: Purpose: Patients with lung disease outside radiotherapy are barred from high dose protocols used for motion modeling, but MRI could offer no-dose alternatives. Image-based ventilation is a promising ...

Evaluation of the Imaging Performance of PET-Linac As Compared to a Diagnostic PET/CT System for Small Tumors

Authors: Muhammad Ramish Ashraf, Girish Bal, Daniel Pham, Murat Surucu

Affiliation: RefleXion Medical, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To systematically evaluate the relationship between Activity Concentration (AC) obtained from the RefleXion PET-Linac with the maximum standardized uptake value (SUVmax) derived from a diagno...

Follow-the-Leader Framework for Adaptable Target Segmentation in Radiotherapy

Authors: Mingli Chen, Xuejun Gu, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: This study introduces a novel template-guided deep learning framework for primary gross tumor volume (GTVp) segmentation, addressing challenges posed by diverse tumor types and enabling a uni...

Identifying Candidates for Endobronchial Valve (EBV) Treatment for Patients with Moderate to Severe Emphysema: Exploring the Use of Estimated Lung Elasticity Using a Biomechanically Based Model Derived from CT Image Data

Authors: Ryan Andosca, Peter Boyle, Grace Hyun Kim, Minji Victoria Kim, Michael Vincent Lauria, Michael F. McNitt-Gray, Gabriel Melendez-Corres, Jack Neylon, Brad Stiehl, Pang Yu Teng

Affiliation: David Geffen School of Medicine at UCLA, University of California, Los Angeles, UCLA Department of Radiology, Department of Radiation Oncology, University of California, Los Angeles, UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Endobronchial Valves (EBV) are one of the few treatment options for patients with moderate to severe emphysema. Eligibility is typically assessed from CT image data analysis including Emphyse...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma Knifeยฎ (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Monte Carlo Verification of Field-Size Dependent Backscatter Effect in Superficial HDR Brachytherapy

Authors: Mandar S. Bhagwat, Casey Y. Lee

Affiliation: Duke University, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: TG43-based dose calculation leads to inaccurate field-size dependent dose calculation in superficial HDR brachytherapy, due to full-scatter condition accounted in TG43, but not during treatme...

Moving Away from Measuring Everything - Implementing 3D Recalculation in a Large Networked Radiotherapy Institution to Replace Routine IMRT / VMAT QA

Authors: Eujin Chan, Christopher Colyer, Leon F Dunn, Jonathan Dunning, Michael Grace, Onno Kamst, Alex Livingstone, Thulani Nyathi, Vladimir Sashin, Philip Satory, Hilmar Schachenmayr, Brindha Subramanian, Lindsay J. Tremethick, Luke Webb

Affiliation: GenesisCare

Abstract Preview: Purpose: The purpose of this work is to outline the methodology and results from the implementation of a 3D recalculation software to replace IMRT/VMAT PSQA measurement across a large, networked radio...

Next Generation Nanoparticles for Fractionated MRI-Guided Radiation Therapy

Authors: Stephanie Bennett, Ross I. Berbeco, Guillaume Bort, Needa Brown, Lena Carmes, Sandrine Dufort, Michael John Lavelle, Geraldine Le Duc, Francois Lux, Toby Morris, Zeinaf Muradova, Andrea Protti, Olivier Tillement

Affiliation: University de Lyon, NH TherAGuIX, University of Massachsetts Lowell and Dana-Farber Cancer Institute Boston, Department of Radiation & Cellular Oncology, University of Chicago, University of Central Florida, Department of Radiation Oncology, Dana-Farber/Brigham and Womenโ€™s Cancer Center, Harvard Medical School, NH TherAguix, Universite de Lyon, Brigham and Women's Hospital, Dana-Farber Cancer Institute

Abstract Preview: Purpose: AGuIX is a theranostic Gd-based nanoparticle currently under phase-2 clinical testing where patients receive 2-3 doses at 1-week intervals prior to imaging and irradiation. AGuIX-Bi is a new ...

Nomogram Based on Interpretable Multiregional Radiomics of Cone-Beam Breast CT and Clinicopathologic Features for Predicting FISH Status in HER2 2+ Breast Cancer to Differentiate HER2-Low from -Positive: A Multi-Center Study

Authors: Keyi Bian, Marco Caballo, Wenxiu Guo, Haijie Li, Jiao Li, Aidi Liu, Yue Ma, Ioannis Sechopoulos, Yafei Wang, Yaopan Wu, Zhaoxiang Ye, Yuwei Zhang, Yueqiang Zhu, Daan van den Oever

Affiliation: Radboud University Medical Center, Tianjin Medical University Cancer Institute & Hospital, Sun Yat-Sen University Cancer Center

Abstract Preview: Purpose: To develop and validate a nomogram integrating intra- and peritumoral radiomics of contrast-enhanced cone-beam breast CT (CE-CBBCT) and clinicopathologic features for predicting fluorescence ...

Optimization of Impulsed Acquisition Protocols on 1.5T MRI Using Simulation-Based Bayesian Experimental Design for Cell Size Imaging

Authors: Yan Dai, Jie Deng, Xun Jia, Wen Li, Junzhong Xu

Affiliation: Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiology, Vanderbilt University Medical Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Cell size is a vital parameter in evaluating the tumor microenvironment, including cell apoptosis and radiotherapy(RT)-induced immune cell infiltration. The IMPULSED(Imaging Microstructural P...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital Wรผrzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Predicting Prostate Cancer Recurrence Using an Atlas-Based Tumor Control Probability Model

Authors: Jeremy T. Booth, Martin Andrew Ebert, Robert Finnegan, Annette Haworth, George Hruby, Burhan Javed, Kazi Ridita Mahtaba, Leyla Moghaddasi, Yutong Zhao

Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, The University of Sydney, The University of Western Australia, Genesis Care, Rockhampton Hospital

Abstract Preview: Purpose:
To evaluate the efficacy of an atlas-based tumor control probability (TCP) model in predicting prostate cancer (PCa) recurrence by retrospectively integrating patient-specific primary radi...

Predictive Quality of Differing Body Size Measurands for Radiation Risk Estimation in CT Imaging: A Virtual Trial Study

Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...

Skin Lesion Subtype Classification Using Lesion and Border Radiomic Features

Authors: Rituparna Basak, Maede Boroji, Renee F Cattell, Vahid Danesh, Imin Kao, Kartik Mani, Xin Qian, Samuel Ryu, Tiezhi Zhang

Affiliation: Stony Brook Medicine, Stony Brook University, Washington University in St. Louis, Stony Brook University Hospital

Abstract Preview: Purpose: Fundamental qualitative characteristics physicians use to differentiate skin lesion subtypes include asymmetry, border irregularity, and color. Radiomic features have potential to quantify th...

Surface Dose Distribution Analysis Using Cherenkov Imaging for Total Skin Electron Therapy (TSET) with Scintillator and Osld Validation

Authors: Baozhu Lu, Hongjing Sun, Timothy C. Zhu, Yifeng Zhu

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: This study aims to validate the feasibility of using Cherenkov imaging for surface dose distribution measurement during Total Skin Electron Therapy (TSET) by developing a perspective-correcte...

The Analysis of the Bifurcation from Immune-Limited to Immune-Escape Mode in Tumor Size

Authors: Young-Bin Cho, Jacob Scott, Nara Yoon

Affiliation: Adelphi University, Cleveland Clinic

Abstract Preview: Purpose: The immune system plays a critical role in determining cancer prognosis. Based on our prior study (Cho et al., 2023) about the bystander effect induced by immune responses in spatially design...

The Effect of Radiotherapy Structure Shape Features on the Accuracy of Their Digital Representation and Manipulation

Authors: Annie Cooney, Kenneth L. Homann, Somayeh Taghizadehghahremanloo, Adam D. Yock, Hong Zhang

Affiliation: Assistant Professor, Vanderbilt University Medical Center

Abstract Preview: Purpose:
Digital radiotherapy data has been standardized using the DICOM format. However, different radiotherapy software environments interpret identical data differently due to inherent software ...

Variations in Radiation Isocenter Offsets from the Winston-Lutz Test Performed on Different Photon Energies

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: To quantity variations in Winston Lutz (WL) test results due to different energies used in SBRT, SRT or SRS.
Methods: A WL phantom with a 6.4 mm diameter center radio-opaque sphere is used...