Search Submissions 🔎

Results for "detector array": 31 found

3D Printing Assisted Collimator Design for Fan Beam-Based X-Ray Fluorescence Tomographic Imaging

Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega

Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...

A 2D Discrete Ionization Chamber Array for Proton Pencil Beam Scanning Flash Dosimetry

Authors: Fu-Xiong Chang, Arpit M. Chhabra, J Isabelle Choi, Chanda Guha, Nancy Y Lee, Chih-Hsun Lin, Haibo Lin, Hang Qi, Mahbubur Rahman, Charles B. Simone, Pingfang Tsai, Shouyi Wei, Irini Yacoub, Yunjie Yang, Ajay Zheng, Jun Zhou

Affiliation: New York Proton Center, Montefiore Medical Center and Albert Einstein College of Medicine, Liverage Biomedical Inc., Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, Institute of Physics, Academia Sinica

Abstract Preview: Purpose: FLASH therapy presents an opportunity to alter the radiotherapy paradigm and significantly enhancing normal organ protection while maintaining the effectiveness of tumor control. The temporal...

A Comparison of Segment-By-Segment Versus Cumulative Signal Evaluation for Patient-Specific QA Using the Integral Quality Monitor

Authors: John J. DeMarco, Farideh Pak, Olivia Grahm C Valadie

Affiliation: Cedars Sinai, Cedars-Sinai, Cedars-Sinai Medical Center

Abstract Preview: Purpose: To investigate the performance of the Integral Quality Monitor (IQM) device for patient-specific QA, focusing on segment-by-segment signal evaluation compared to cumulative signal evaluation....

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Assessment of the Auto Registration Feature of the PET/CT Linac Used for Biology Guided Radiation Therapy (BGRT)

Authors: Emily Hansen, Tyler Kaulfers, Alois M. Ndlovu, Francia Romero, Niara Rowe, Roland Teboh

Affiliation: Montefiore Einstein University Hospital, Hackensack University Medical Center

Abstract Preview: Purpose: Daily use and reliance on the auto registration feature requires a performance check. Clinical application of auto registration is performed without a selected region of interest (ROI), requi...

Asymmetrical High Performance Brain Dedicated PET System: Design Optimization and Performance Evaluation

Authors: Yuemeng Feng, Hamid Sabet

Affiliation: Massachusetts General Hospital, Harvard Medical School

Abstract Preview: Purpose: We propose a novel brain-dedicated PET system comprising elliptical cylinder with a neck cut-out, supplemented by front and back panels to improve sensitivity and line-of-response sampling. T...

BEST IN PHYSICS IMAGING: Volumetric Sampling Properties of Longitudinal Multiple X-Ray-Source Array Computed Tomography (MXA-CT)

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...

Clinical Implementation of a Film Based Psqa System for SBRT on a 1.5T MR-Linac

Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal

Affiliation: Sunnybrook Health Sciences Centre

Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Commissioning of a 3D-CRT Planning Software for a Machine with Only Flattening-Filter Free Energy

Authors: Michalis Aristophanous, Steven Blum, Laura I. Cervino, Antonio L. Damato, Karen Episcopia, Chi Huang, Shih-Chi Lin, Michelle K. Savacool

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Varian Ethos (Varian Medical Systems, Palo Alto, CA) is a 6 MV flattening-filter-free (FFF) only machine, posing a challenge in creating homogeneous dose distributions when using manual 3D-CR...

Comparison Analysis of Three Kind of Solutions for Head and Neck Cancer VMAT Verification

Authors: Wenwen Bai

Affiliation: The Fourth Hospital of Hebei Medical University

Abstract Preview: Purpose: To compare three kind of solutions (EDR2 Film, MatriXX, COMPASS) for VMA quality assurance at head and Neck in Monaco plannig system.
Methods: Monacao 5.1 planning system optimazed 10 case...

Design of Next Generation Hemispherical Brain PET System Aiming for 1mm Resolution

Authors: Go Akamatsu, Yuma Iwao, Kurumi Narita, Hideaki Tashima, Taiga Yamaya, Eiji Yoshida

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In brain positron emission tomography (PET), higher spatial resolution is better for visualizing detailed structures such as small nuclei and the layered structure of the cerebral cortex. The...

Development of Cross-Platform Application for Radiation Contamination Assessment

Authors: Wesley E. Bolch, Lotem Buchbinder Shadur, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Shaheen Dewji, John Francis, Emmanual Mate-Kole, Wyatt Smither, Yitian Wang

Affiliation: Georgia Tech, University of Florida, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: Develop a software application capable of assessing the radiation contamination of military service members and members of the general public for fast, on-site radiological triage. The softwa...

Development of a Cadmium Zinc Telluride (CdZnTe) Detector-Based Neutron Imaging System

Authors: Soo Hyun Byun, Troy Farncombe, Edcer Jerecho DC Laguda

Affiliation: McMaster University

Abstract Preview: Purpose: We present the adaptation of a Cadmium Zinc Telluride (CdZnTe) detector, initially designed for SPECT-MR applications, to neutron imaging. This study explores a novel technique that utilizes ...

Development of a High-Speed Digital Breast Tomosynthesis System with a Two-Dimensional Multiple X-Ray-Source Array

Authors: John M. Boone, Andrew M. Hernandez, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski

Affiliation: Johns Hopkins University, University of California, UT MD Anderson Cancer Center, University of New Mexico Albuquerque, UC Davis Health

Abstract Preview: Purpose: To significantly improve image quality relative to clinically deployed digital breast tomosynthesis (DBT) systems, which use a 1D acquisition geometry (an arc), with a 2D image acquisition ge...

Dose Distribution Analysis for Different Geometries of a Multiple-X-Ray Source Array (MXA) CT Scanner

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A Multiple-X-ray Source Array (MXA) for CT (MXA-CT) is under development to mitigate cone beam artifacts in axial CT scans using wide collimation. The purpose of this study is to assess the i...

Dosimetric Characterization of Sun Nuclear EDGE Diodes in the Plateau Region of Proton Pencil Beam Scanning (PBS) Fields

Authors: Wesley S. Culberson, Ryan Gardner, Patrick M Hill, Mark Pankuch, Karsten K. Wake

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Wisconsin, Northwestern Medicine Proton Center

Abstract Preview: Purpose: To assess the dosimetric capabilities of Sun Nuclear (Melbourne, FL) EDGE Diode Detectors™ for measurements in the plateau region of pencil beam scanning (PBS) fields. Many clinical dosimeter...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko Salomón Alva Sánchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Evaluation of Four Different Dose Calculation Algorithms for Commissioning of a New Tyoe of Scanned Proton Therapy System

Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga

Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University

Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

Feasibility and Consistency of a Quad Wedge with a 2D Detector Array for Routine Quality Assurance on a MR-Linac

Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin

Affiliation: Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...

High-Energy Current Detectors for Proton Dose-Rate Beam Monitoring at Flash Dose-Rates.

Authors: Davide Brivio, Lia Carroll, Juliane Daartz, Jan PO Schuemann, Piotr Zygmanski

Affiliation: Massachusetts General Hospital, Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: We employ High-Energy Current (HEC) detectors for real-time monitoring of proton beams at conventional to FLASH dose rates. This would help overcome the need for fast and accurate dosimeters ...

Imaging Preclinical Proton Flash Radiation Using a Small Animal PET System

Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...

Inverse Geometry Photon Counting CBCT

Authors: Saree Alnaghy, Owen Thomas Dillon, Sean P Hood, Paul J. Keall, Ricky O'Brien, Tess Reynolds

Affiliation: Image X Institute, Faculty of Medicine and Health, The University of Sydney, University of Wollongong, Medical Radiations, School of Health and Biomedical Sciences, RMIT University

Abstract Preview: Purpose: Photon Counting Detectors (PCDs) have been demonstrated to improve resolution, contrast and lesion detectability in fan-beam CT. There is naturally a desire to bring these improvements to Con...

Monte Carlo Modeling of an Experimental X-Ray Fluorescence Computed Tomography (XFCT) System with a Pixelated CdTe Detector

Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Neerajan Nepal

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: To develop/validate a Monte Carlo (MC) model of an experimental benchtop x-ray fluorescence computed tomography (XFCT) system with a pixelated CdTe detector that can be used for MC simulation...

Multiple x-Ray Source Array (MXA) System Development for Better Ray Sampling in Large Coverage Axial CT Imaging

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Sarah E. McKenney, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose:
While wide coverage (160 mm) CT scanners can image whole organs (e.g. heart, brain, kidneys, etc.) in one axial scan, the peripheral regions of the field of view (along z) suffer from cons...

Optimizing Motion Management QA: Clinical Integration of Aapm TG-306 for the Radixact Synchrony System

Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...

Prior-Informed Neural Super-Resolution Dosimetry for Radiotherapy QA from Sparse Dosimeter Arrays

Authors: Muhammad Ramish Ashraf, Clinton Gibson, Gregory Szalkowski, Lei Wang, Siqi Wang, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University School of Medicine, Stanford University

Abstract Preview: Purpose: To develop a neural network-based super-resolution framework for enhancing the resolution of sparse dosimetry measurements in patient-specific radiotherapy QA. Sparse detector arrays, such as...

Proton CT-Imaging and Radiography Using 3D-Detector with Plastic Scintillators for on-Board Proton Imaging

Authors: Salahuddin Ahmad, Imad M. Ali, Zaid Alkalani, Nesreen Alsbou

Affiliation: University of Oklahoma, University of Central Oklahoma, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose: To design and evaluate a 3D-detector for proton CT-imaging and radiography, utilizing volumetric plastic scintillator detector exposed to high-energy therapeutic beams from proton therapy sys...

Streamlined Calibration of Mosfet Dosimeters for Radixact Systems: Addressing Angular Dependence and Beam Profile Challenges

Authors: Guang-Pei Chen, Renae Conlin, Juan A. Garcia-Alvarez, Kirk Morris, Haidy G. Nasief, Eenas A. Omari, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Cumulative dose limits make replacing and calibrating Metal Oxide Semiconductor Field Effect dosimeters (MOSFET-d) used for in-vivo dosimetry a common clinical task. Calibration protocols for...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...