Search Submissions 🔎

Results for "differences ranges": 102 found

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

A New Algorithm for Charged Particle Therapy Beam Energy Measurement By Time-of-Flight

Authors: Sung Woon Choi, Dong Wook Kim, Jin Sung Kim, Na Hye Kwon, Paulo Jorge Ribeiro Da Fonte

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Coimbra Institute of Engineering, Polytechnic University of Coimbra

Abstract Preview: Purpose: In hadrontherapy, such as proton and carbon ion therapy, it is desirable, for quality assurance reasons, to have an online beam energy measurement independent from the machine parameters. Sin...

A Quantitative Metric for Evaluating Treatment Plan Robustness in Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Stephen Shang

Affiliation: South Florida Proton Therapy Institute, SFPRF

Abstract Preview: Purpose: Proton pencil beam scanning therapy is particularly sensitive to field translational shifts and beam range variations, which can degradation of dose distribution and compromise the treatment....

A Radiomic Quantification Framework for Hyperparameter Optimization in Texture Characterization

Authors: Yuli Lu, Chendong Ni, Cheng Qian, Kun Qian, Weiwei Sang, Chunhao Wang, Fan Xia, Zhenyu Yang, Fang-Fang Yin, Rihui Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Duke University, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: To develop a radiomic quantification framework to evaluate the effects of radiomic image preprocessing hyperparameters (i.e., image resampling and discretization) on texture characterization ...

Accuracy Analysis of "Sphere-Mask" Optical Positioning System in Radiotherapy of Breast Cancer

Authors: Xiu tong Lin, Tao Sun

Affiliation: Department of Radiation physics and technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the positioning accuracy and time efficiency of "Sphere-Mask" Optical Positioning System (OPS) and traditional laser light positioning method in breast cancer radiotherapy, and to ...

Accuracy Assessment of Bragg Peak Imaging Using Protoacoustics at a Clinical Dose

Authors: Michael Caulfield, Ye Chen, Yoshihiro Ishi, Yasutoshi Kuriyama, Taeko Matsuura, Naoki Miyamoto, Taichi Murakami, Tomonori Uesugi, Kohei Yokokawa

Affiliation: Hokkaido University, Kyoto University, University of Alberta

Abstract Preview: Purpose: Protoacoustics has the potential for real-time and direct imaging of the Bragg peak. This study investigated the accuracy of the Bragg peak imaging based on the water phantom experiment at a ...

Advancing Cardiac Sparing with Upright Patient Geometry and Deep Learning

Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan

Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care

Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...

An Automated Approach to Monitoring Clinical Protocols Against a Master Protocol

Authors: Jeremy Christophel, Zhihua Qi

Affiliation: Henry Ford Health

Abstract Preview: Purpose: To demonstrate a method to compare DICOM metadata from clinical scanners with institutional protocols as validation that clinical use matches the master protocol.
Methods: DICOM metadata i...

An Evaluation of an SRS Quality Assurance System for Complex Patient Plans.

Authors: John Bennet, Indrin J. Chetty, Tai H. Dou

Affiliation: Department of Radiation Oncology,Cedars Sinai Medical Center, Department of Radiation Oncology, Cedars Sinai Medical Center, Department of Radiation Oncology,Cedars-Sinai Medical Center

Abstract Preview: Purpose:
To investigate the effect of complexity of stereotactic radiosurgery (SRS) volumetric modulated arc therapy plans on gamma pass rates (GPR) using a novel high-resolution ion chamber array ...

Analysis of Collimation during Fluoroscopically-Guided Interventions: Using a Large-Scale Archive to Assess Collimation during Different Procedures

Authors: James R Duncan, Nikhat Fatima Mansoori, Allan Thomas

Affiliation: Mallinckrodt Institute of Radiology, Washington University School of Medicine

Abstract Preview: Purpose: Collimation during fluoroscopically-guided interventions (FGIs) can not only reduce radiation exposure to patients and personnel but also improve image quality. Nonetheless, there are concern...

Application of a Conditional Diffusion Model to Improve Real-Time MR Imaging in Online Adaptive MR-Guided Radiotherapy

Authors: Hideaki Hirashima, Haruo Inokuchi, Nobutaka Mukumoto, Naruki Murahashi, Mitsuhiro Nakamura, Megumi Nakao, Keiko Shibuya, Linna Zhang

Affiliation: Kyoto University, Osaka Metropolitan University

Abstract Preview: Purpose:
To transform the quality of 2D cine MR images acquired during online adaptive MR-guided radiotherapy (OA-MRgRT) by utilizing a conditional diffusion model to achieve image quality comparab...

BEST IN PHYSICS IMAGING: Revolutionizing Neurocognitive Dynamic Pattern Discovery with Self-Supervised AI in Functional Brain Imaging

Authors: Lei Xing, Zixia Zhou

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University, Stanford

Abstract Preview: Purpose: Functional brain imaging techniques, such as functional magnetic resonance imaging (fMRI), generate high-dimensional, dynamic data reflecting complex neural processes. However, extracting rob...

BEST IN PHYSICS THERAPY: Impact of Local Tissue Oxygenation Level on the Flash Effect in Murine Skin

Authors: David J. Gladstone, P. Jack Hoopes, David I Hunter, Brian W Pogue, Jacob Pierce Sunnerberg, Armin Tavakkoli

Affiliation: Thayer School of Engineering, Dartmouth College, University of Wisconsin - Madison, Department of Radiation Oncology, Perelman School of Medicine, University of Pennsylvania, Geisel School of Medicine, Dartmouth College

Abstract Preview: Purpose: The FLASH effect, characterized by normal tissue sparing under ultra-high dose rate (UHDR) radiation delivery, remains mechanistically unclear. This study investigated the relationship betwee...

Best- and Worst-Case Scenario: Uncertainty Bounds Informed By Daily Scanning in Weekly CBCT-Based Accumulated Dose for Head and Neck Cancer

Authors: Peter Balter, Kristy K. Brock, Clifton David Fuller, Tze Yee Lim, James Long, Brigid A. McDonald, Androniki Mitrou, Andrew J. Schaefer, Stina Svensson

Affiliation: The University of Texas MD Anderson Cancer Center, RaySearch Laboratories, Rice University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: CBCT-based accumulated dose can provide up-to-date dose information on responding anatomy. To optimize resources, it is necessary to determine how many scans provide adequate information for ...

Characterization of HCC Tumor Response in 90Y-Radioembolization Clinical Trial RAPY90D Using Prospective Voxel Dosimetry

Authors: E Courtney Henry, Srinivas Cheenu Kappadath, Armeen Mahvash

Affiliation: UT MD Anderson Cancer Center

Abstract Preview: Purpose:
Characterization of hepatocellular carcinoma (HCC) tumor responses for single-arm single-center prospective 90Y-radioembolization clinical trial (n=40) that used patient-specific voxel-dos...

Characterization of Novel Shielded and Unshielded Silicon Diode Detectors for Photon and Electron Dosimetry in Radiation Therapy

Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing

Affiliation: CDT-West - Centrum fĂŒr Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies

Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.

Methods: The novel shielded and unshielded sili...

Characterization of a Prototype Flashdiamond Detector for Conventional and Uhdr Beams

Authors: Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose:
To evaluate the dose rate dependence, beam quality dependence, and short-term stability of a novel flashDiamond (fD) prototype detector for conventional and ultra-high dose rate (UHDR) bea...

Characterizing an Osld Dosimetry System for Use in a Multi-Clinic Environment

Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...

Clinical Experience with an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...

Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Comparison of CBCT Dose Calculation Accuracy between Truebeam Hypersight Image Reconstruction Algorithms

Authors: Sarah Aubert, Harald Keller, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Support for treatment planning directly on CBCT imaging on C-arm linacs will enable adaptive radiation therapy (ART) capacity with increased treatment technique flexibility. The HyperSight im...

Comparison of Frame-Based and Frameless Gamma Knife Coordinate Spaces for Treatment of Trigeminal Neuralgia

Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...

Comparison of Respiratory Motion between 4D-MR and 4D-CT in Compression Belt Patients

Authors: Morgan Aire, Krystal M. Kirby, Olivia Magneson, David E. Solis, Hamlet Spears

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the range of motion of abdominal organs using 4D stack-of-stars magnetic resonance (MR) imaging and 4D computed tomography (CT), the current clinical standard. Accurate o...

Comprehensive Evaluation of High-Performance Cone-Beam Computed Tomography on C-Arm and Ring-Gantry Linacs for Adaptive Radiation Therapy

Authors: Laura I. Cervino, Karen Episcopia, Hsiang-Chi Kuo, Sangkyu Lee, Seng Boh Gary Lim, Shih-Chi Lin, Grace Tang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: This study evaluated the performance of the HyperSight Cone-Beam Computed Tomography (CBCT) system on a TrueBeam C-arm LINAC (TB) and two Ethos ring-gantry LINACs (ES) for adaptive radiation ...

Correlation of Dose Volume Metrics with Skin Systemic Sclerosis 12 Months Post Radiotherapy for Head & Neck Cancer

Authors: Gregory A Azzam, Danielle Cerbon, Laura Huang, Panayiotis Mavroidis, Diana Molinares, Stuart E Samuels, Sotirios Stathakis

Affiliation: Mary Bird Perkins Cancer Center, University of Miami Sylvester Comprehensive Cancer Center, Mount Vernan Rehabilitation Medicine Associates, Department of Radiation Oncology, University of Miami, University of North Carolina

Abstract Preview: Purpose: This study examines the correlation of different dose volume metrics of the skin, sternocleidomastoid (SCM) muscle and subcutaneous tissue (subcut) structures with the skin systemic sclerosis...

Cross-Calibration and Comparison of CT Number to Electron Density Using Two Calibration Phantoms

Authors: Afrouz Ataei, Xinhui Duan, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu

Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose:
Electron density (ED) phantoms are crucial for calibrating CT number (HU) to relative ED in treatment planning. This study evaluates the differences in HU-to-ED calibrations between two co...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Development and Clinical Validation of an Analytical Approach for 3D Positron Emitter Distribution Prediction in Carbon Ion Therapy

Authors: Julia Bauer, Tianxue Du, Katia Parodi, Marco Pinto, Thomas Tessonnier

Affiliation: Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Heidelberg Ion Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)

Abstract Preview: Purpose:
Carbon ion therapy could benefit from range verification due to its sensitivity to range uncertainties. Positron emission tomography (PET) aids in this and comparing irradiation-induced PE...

Development of a Proton CT System Based on 2D Scintillation Detection

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China

Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...

Diffusion Model-Based Motion Correction in Portable Computed Tomography for Brain: Human Observer Study

Authors: Rajiv Gupta, Rehab Naeem Khalid, Min Lang, Michael H Lev, Quirin Strotzer, Matthew Tivnan, Maryam Vejdani-Jahromi, Dufan Wu, Siyeop Yoon, Chen Zhennong

Affiliation: Massachusetts General Hospital

Abstract Preview: Purpose: Patient motion is a major source of artifacts in portable brain CT due to the slow scanning speed. A diffusion model was developed to reduce these motion artifacts. This work aims to assess t...

Dosimetric Analysis of Lymphopenia after Lung Irradiation and Modeling the Probability of Normal Tissue Complications

Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin

Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: Decreased lymphocytes increase the risk of infections and other problems. Radiation exposure can cause the development of severe lymphopenia. In this study, we used a dynamic blood flow model...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Dosimetric Impact of Auto-Segmentation with Replanning: An Analysis of a Prospective Clinical Trial

Authors: Kathryn J. Dess, Martha M. Matuszak, Dan Polan

Affiliation: University of Michigan

Abstract Preview: Purpose: A recent survey demonstrated 18 of 20 top academic institutions have implemented auto-segmentation. Studies to date have focused on geometric contour changes and dosimetric differences using ...

EBT4 Film Dosimetry and the Significance of the Œ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Efficient Robustness Optimization in Intensity Modulated Proton Therapy for Head and Neck Cancer Via Visual State Space Attention Generative Adversarial Networks (VSSA-GAN)

Authors: Nan Li, Yaoying Liu, Shouping Xu, Gaolong Zhang

Affiliation: Department of Radiation Oncology, School of Physics, Beihang University, School of physics, Beihang University, National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: In intensity-modulated proton therapy (IMPT) for head and neck cancer, CBCT registration ensures accurate setup, minimizing dose errors. Unlike IMRT, IMPT plans directly define tumor volumes ...

Enhanced Surface Dose Accuracy in Proton Treatment Planning: Optimizing External Volume HU Thresholding.

Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez

Affiliation: University of Miami

Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...

Estimating Organ Dose of Standard Pediatric CT Protocols to Computational Phantoms through the Dukesim CT Simulator

Authors: Dean Darnell, Iyanna M Lewis, Francesco Ria, William Paul Segars

Affiliation: Duke University, Duke University Medical Physics Graduate Program, Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Duke University Medical Center

Abstract Preview: Purpose: To estimate radiation dose to pediatric patients during standard CT imaging of the chest and abdomen and determine how dose varies with patient age, height and weight and how measurements com...

Evaluating Dose Variability in Bladder Contouring for MR-Guided Prostate Cancer Radiotherapy

Authors: Emily Helen Hayes, Chihray Liu

Affiliation: University of Florida

Abstract Preview: Purpose: To evaluate dosimetric discrepancies in bladder dose calculations among rigid, deformed, and manual contouring methods in prostate cancer patients and assess dose variations resulting from bl...

Evaluating the Impact of Spot Spacing on Dosimetric Outcomes in Dynamic Arc Proton Therapy for Prostate SBRT

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is a novel pencil beam scanning (PBS) proton therapy technique with the potential to provide more conformal dose distributions and reduce treatment time. This study investigates th...

Evaluating the Impact of an Average Versus Machine-Specific Dosimetric Leaf Gap on Dose Calculation

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...

Evaluation of AI-Generated Synthetic 4DCT from 3DCT for Radiotherapy Planning

Authors: Shinichiro Mori, Isabella Pfeiffer, Chester R. Ramsey, Alexander Usynin

Affiliation: Thompson Proton Center, National Institutes for Quantum Science and Technology, Thompson Cancer Survival Center

Abstract Preview: Purpose: Four-dimensional CT imaging (4DCT) has become a standard tool for managing respiratory motion in radiation therapy. However, many treatment delivery systems and most diagnostic CT scanners la...

Evaluation of Cherenkov Imaging for Dose Verification in Total Skin Electron Therapy

Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Natasha Mulenga, Kevin J. Willy

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center

Abstract Preview: Purpose: The goal of this work was to use Cherenkov emission imaging to verify patient position, accessory block positioning and dose delivery in Total Skin Electron Therapy (TSET).

Methods: A ...

Evaluation of Proton Therapy Robustness for Thoracic Cancer Patients

Authors: Lordina Owusuwaa Oheneferewoo Asibey, Rachel B. Ger, Heng Li

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Howard University

Abstract Preview: Purpose: Treatment of cancer patients with proton therapy requires robust optimization applications to be able to provide adequate target coverage whiles sparing healthy tissues. Our goal was to evalu...

Evaluation of Thoracic Direct Dose Calculation Using Truebeam Linac with Hypersight Imaging CBCT Solution

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Alex T. Price, Sagar Regmi, Atefeh Rezaei, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To investigate the feasibility and accuracy of using a Hounsfield Unit(HU) calibrated cone-beam computed tomography(CBCT) for direct dose calculation in thoracic treatment settings. In combin...

Evaluation of an Offline Adaptive CBCT Planning Workflow for Halcyon with Hypersight

Authors: Michelle Alonso-Basanta, Joshua Bryer, Lei Dong, Barbara Garcia, Elissa Khoudary, Brandon M. Koger, Taoran Li, Michael Salerno, Karen Tang, Boon-Keng Kevin Teo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: The Varian HyperSight imaging solution features a workflow for planning on CBCT images (CBCTp). This study evaluates the feasibility of CBCTp images in the setting of an offline adaptive plan...

Evaluation of the Extrapolated Output Factors of Varian's Halycon Beam Model for Fields Smaller Than 1 Cm with AAA and Acurosxb

Authors: Arjit K. Baghwala, Devin J. Olek, Parth K. Patel, Ramiro Pino, Adam Yanez

Affiliation: Houston Methodist Hospital, Kaiser Permanente

Abstract Preview: Purpose: The Halcyon beam model in Eclipse is immutable and only includes output factors (OF) for fields down to 1x1 cm2. The TPS must extrapolate OFs for smaller fields used in stereotactic (SRS/SBRT...

Expert Verification of AI-Generated Cardiac Substructures and Dosimetric Differences between Auto-Contoured and Manually Delineated Contours

Authors: Stephen R. Bowen, Richard Cheng, Kylie Kang, Janice Kim, Ana Paula Santos Lima, Dominic A. Maes, Juergen Meyer, Karen Ordovas, Kerry Reding

Affiliation: Department of Radiation Oncology, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiology, University of Washington, Division of Cardiology, University of Washington, Department of Biobehavioral Nursing and Health Informatics, School of Nursing, University of Washington

Abstract Preview: Purpose: Artificial intelligence (AI)-based auto-segmentation tools can increase the efficacy and reproducibility of radiotherapy (RT) treatment planning. This study evaluates the quality of AI-genera...

Feasibility of a Normoxic N-Vinylpyrrolidone-Based Polymer Gel (VIPET) Dosimeter for Three-Dimensional Proton Beam Measurements

Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana

Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East

Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...

Fetal Radiation Exposure Monitoring of Pregnant Employees across Multiple Departments and Areas in a Hospital

Authors: Janet Ching-Mei Feng, Janet Gutierrez, Aylin Ozus, Patricia Svolos

Affiliation: Bellaire High, McGovern Medical School, University of Texas Health Science Center at Houston, Environmental Health & Safety, University of Texas Health Science Center at Houston, UTHealth McGovern Medical School

Abstract Preview: Purpose: Exposure to radiation may become harmful to the fetus depending on the gestational age and absorbed dose. The Nuclear Regulatory Commission states the radiation exposure to the embryo/fetus o...

Fractionation of Electron RT Reduces the Flash Effect in Murine Skin

Authors: Xu Cao, Wesley S. Culberson, Aleksandra Ilina, Kendall Jarvis, Brian W Pogue, Matthew Reed, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel

Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison

Abstract Preview: Purpose: While FLASH radiotherapy is known to reduce skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR). Currently it is not clear whether this ...

From Concept to Clinic: A Phase-Based Approach for Implementing Auto-Segmentation in Radiation Therapy

Authors: Elizabeth L. Covington, Robert T. Dess, Charles S. Mayo, Michelle L. Mierzwa, Dan Polan, Jennifer Shah, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Auto-segmentation improves contour consistency and standardization in radiation therapy but may introduce variations from current practices, potentially impacting treatment outcomes and toxic...

Generalization of the Conformity Index for Multi-Target Radiotherapy Plans

Authors: Jianrong Dai, Jun Dang, Enzhuo Quan, Yong Sang, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center / National Clinical Research Center for Cancer / Cancer Hospital & Shenzhen Hospital / Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: The current conformity index (CI) formula is distorted for radiotherapy plans with multiple, non-enclosing targets. We redefined the volume of reference isodose (VTV) parameter in the CI form...

Identifying Candidates for Endobronchial Valve (EBV) Treatment for Patients with Moderate to Severe Emphysema: Exploring the Use of Estimated Lung Elasticity Using a Biomechanically Based Model Derived from CT Image Data

Authors: Ryan Andosca, Peter Boyle, Grace Hyun Kim, Minji Victoria Kim, Michael Vincent Lauria, Michael F. McNitt-Gray, Gabriel Melendez-Corres, Jack Neylon, Brad Stiehl, Pang Yu Teng

Affiliation: David Geffen School of Medicine at UCLA, University of California, Los Angeles, UCLA Department of Radiology, Department of Radiation Oncology, University of California, Los Angeles, UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Endobronchial Valves (EBV) are one of the few treatment options for patients with moderate to severe emphysema. Eligibility is typically assessed from CT image data analysis including Emphyse...

Imaging Preclinical Proton Flash Radiation Using a Small Animal PET System

Authors: Xun Jia, Heng Li, Wen Li, Devin Miles, Daniel Sforza, Lingshu Yin, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: FLASH therapy holds great potential to revolutionize radiotherapy by minimizing toxicities of normal tissues. The extraordinarily high dose rate of FLASH proton beam makes precise delivery to...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Proton Beam Arrangements on LETd and RBE in Organs at Risk for Nasopharyngeal Cancer

Authors: Mauricio Acosta, Zachary Fellows, Alonso N. Gutierrez, Noah S. Kalman, Kristen A. McConnell, Rob Rohe, Andrew J. Wroe, Sreenija A Yarlagadda

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Beam selection is crucial in proton therapy to ensure optimal physical and biological dose conformity to the target while maximizing sparing of normal tissue. This work investigates the im...

Impact of Time-of-Flight Reconstruction and Motion Correction on PET-Based Dosimetry in 90y Radioembolization for Hepatocellular Carcinoma

Authors: Spencer Behr, Joseph Grudzinski, Youngho Seo, Jaehoon Shin, Yiran Wang, Frederick J. Wilson

Affiliation: University of California San Francisco, University of California, San Francisco, Voximetry, Inc., Voximetry, Inc

Abstract Preview: Purpose: Voxel-level imaging-based dosimetry enables a significant improvement in accurate and personalized treatment planning in radiopharmaceutical therapy, potentially leading to optimized disease ...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Integrating Large Kernel Attention Mechanism into Deep Learning Model for Automatic and Auccrate Segmentation of Gross Tumor Volume in Lung Cancer Patients

Authors: Xuezhen Feng, Li-Sheng Geng, Haoze Li, Xi Liu, Tianyu Xiong, Ruijie Yang

Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, School of Physics, Beihang University, School of Nuclear Science and Technology, University of South China, Department of Radiation Oncology, Peking University Third Hospital

Abstract Preview: Purpose: This study aimed to develop a deep learning-based algorithm for automatically delineate gross tumor volume (GTV) for lung cancer patients, alleviating the workload of radiologists and improvi...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Investigation of Metallic Artefact Reduction Capabilities of Hypersight Enabled Platforms

Authors: Harald Keller, Iymad Mansour, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...

Knowledge-Based Three-Dimensional Dose Prediction for High Dose Rate Prostate Brachytherapy

Authors: Mojtaba Behzadipour, Suman Gautam, Tianjun Ma, Ikchit Singh Sangha, Bongyong Song, William Song, Kumari Sunidhi

Affiliation: UC San Diego, Virginia Commonwealth University

Abstract Preview: Purpose: This study aims to develop a knowledge-based voxel-wise dose prediction system using a convolutional neural network (CNN) for high-dose-rate (HDR) prostate brachytherapy and to evaluate its p...

LD-V1 Film Characterization for MV Beam Quality

Authors: Ruiming Chen Edmondson, Darwin Abraham Garcia, James A. Kavanaugh, Joseph John Lucido

Affiliation: Mayo Clinic

Abstract Preview: Purpose: Characterize the dose response and reproducibility of a low-dose film for 6 MV photon beam and assess the film’s energy dependence between kV and MV energies.
Methods: A single 8’x10’ LD-V...

Learning from Failures – Case Studies into Failing Patient Specific Quality Assurance Plans

Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh

Affiliation: Tufts Medical Center

Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...

Long-Term Stability Assessment of an Imaging Ring System Using One Year of Monthly Quality Assurance Data

Authors: Awens Alphonse, Nebi Demez, Brian P. Laffey, Shyam Pokharel, Suresh Rana, Nishan Shrestha

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: The Imaging Ring is a mobile digital X-ray system capable of producing 2D planar X-rays, fluoroscopy, and 3D Cone-Beam Computed Tomography (CBCT) images. This study aimed to evaluate the long...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

Novel Fast Cone-Beam CT for Adaptive Radiotherapy: Assessment of Image Distortion, Auto-Contouring, and Dose Delivery Accuracy in the Presence of Periodic Subject Motion

Authors: David P. Adam, William T. Hrinivich, Taoran Li, Alexander Lu, Michael Salerno, Alejandro Sisniega, Boon-Keng Kevin Teo

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, University of Pennsylvania

Abstract Preview: Purpose: Cone beam CT (CBCT)-guided online adaptive radiotherapy (ART) is of growing interest, with recent improvements in image quality provided through larger detector panels and fast gantry rotatio...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

On the Sensitivity Evaluation of End-to-End Test in Radiotherapy

Authors: Yussuf A. Abdelal, Sebastien A. Gros, Luke Layman, Anil Sethi

Affiliation: Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago

Abstract Preview: Purpose:
End-to-end (E2E) test is a vital QA check of the overall radiotherapy process from simulation imaging to treatment delivery. Although clinical passing criteria are available, guidelines on...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Optimizing Quality Assurance CT Frequency and Setup Uncertainty in Brain Proton Therapy Patients for Reduced Normal Tissue Dose

Authors: Rachel B. Ger, Heng Li, Anh Tran

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients undergo quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and utilize robustness scenarios for setup and range uncertainties. For intra...

Planning Study of Spatially Fractionated Radiotherapy (SFRT) for Treating Recurrent Glioblastoma Multiforme (GBM)

Authors: Hyunuk Jung, Fiona Li, Brian Marples, Michael Milano, Sean M. Tanny, Dandan Zheng, Yuwei Zhou

Affiliation: Department of Radiation Oncology, University of Rochester, University of Rochester Medical Center, University of Rochester

Abstract Preview: Purpose:
Recurrent GBM remains one of the most challenging cancers, with limited treatment options. We investigated potential planning parameters of SFRT, a novel radiotherapy technique that delive...

Post-Implant Dosimetry (PID) between 1D and 2D Cs-131 Seed Models for Post-Op Cavities in Recurrent GBM Patients

Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health

Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Predicting Brain V60% in Linac-Based Single-Isocenter-Multiple-Targets (SIMT) Stereotactic Radiosurgery Using Machine Learning

Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Quantitative Image Review Metric for Vertebral Body Misalignment

Authors: Luis E. Fong de los Santos, Douglas John Moseley, Satomi Shiraishi, Cenji Yu

Affiliation: Mayo Clinic

Abstract Preview: Purpose: To quantitatively detect errors in vertebral body localization using normalized cross correlation (NCC)

Methods: Volumetric images of a thoracic end-to-end SBRT phantom with a removabl...

Radionuclide Therapy Patient Release Dose Calculation Using a Non Point Model

Authors: Tianliang Gu

Affiliation: UT Health Science Center at Houston

Abstract Preview: Purpose:
In Nuclear Regulatory Commission guide 8.39 on releasing patients administered radioactive material, the dose is calculated assuming both the source and receiver are points. This point mod...

Robust Evaluation of Rotational Uncertainties on Single-Isocenter Multi-Target Stereotactic Radiosurgery Hyperarc Treatment

Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...

Robustness Evaluation of Aperture Shape Controller in Postmastectomy Radiotherapy of Breast Cancer Using Volumetric Modulated Arc Therapy

Authors: Yukio Fujita, Satoshi Ishikura, Fumiki Ito, Yujiro Nakajima, Takumi Sakamoto, Naoki Tohyama, Ryohei Yamauchi

Affiliation: Komazawa University Graduate School, St. Luke's International Hospital

Abstract Preview: Purpose: The aperture shape controller (ASC) is an Eclipse feature that increases muti-leaf collimator (MLC) aperture size. This study aimed to evaluate the effects of ASC settings on the robustness o...

Robustness Evaluation of Dynamic Arc Proton Therapy: A Comparative Analysis of Small and Large Spot Sizes in Lung and Prostate Cancer Planning

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Hina Saeed, Gagandeep Saini, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the robustness of DynamicARC proton therapy plans for lung and prostate cancer, comparing small spot size (SS) and large spot size (LS) plans under nominal and worst-case...

Secondary Neutron Dosimetry of Cieds Exposed to Neutron-Producing Photon Radiation Therapy

Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin

Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...

Technical Feasibility and Accuracy of Dynamic Longitudinal Couch Motion during Beam Delivery

Authors: Chonthicha Bunchuailuea, David Geeler, Martin Sabel, Claas Wessels

Affiliation: Varian Medical Systems

Abstract Preview: Purpose: Elongated treatment sites, such as craniospinal treatments, pose multiple challenges in today’s practices, requiring multiple CBCTs for position verifications per fraction, which might increa...

The CT Calibration for Proton Pencil Beams System

Authors: Xiangli Cui, Wanli Huo, Jie Li, Lingling Liu, Tao Ma, Yuanyuan Wang

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Ion Medical Center, Hefei Cancer Hospital, Chinese Academy of Sciences, the Zhejiang-New Zealand Joint Vision-Based Intelligent Metrology Laboratory, College of Information Engineering, China Jiliang University

Abstract Preview: Purpose: In practice, treatment planning systems (TPS) of proton therapy require a CT calibration curve, which relates Hounsfield units (HU) to relative stopping power (RSP). Single-energy CT as a sta...

Through in-House Software and Customized Phantom to Perform and Analyze Daily Quality Assurance of Proton Treatment System More Efficiently and Monitor the Stability of Its Performance

Authors: Liang-Hsin Chen, Li-Chien Wei

Affiliation: National Taiwan University Cancer Center

Abstract Preview: Purpose: For proton therapy treatment, it is essential to ensure that the treatments are delivered safely and accurately. Quality assurance (QA) programs of proton treatment system is needed and proto...

Towards Optimal Target Dose Conformity and Dose Drop-Off: Evaluation of a New Optimization Approach for Biology-Guided Radiotherapy Treatment Planning

Authors: Grant Gibbard, Chunhui Han, An Liu

Affiliation: RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: To evaluate the efficacy of a new approach to streamline treatment planning for biology-guided radiotherapy (BgRT) of fluorodeoxyglucose (FDG)-avid bony lesions on a BgRT machine with real-ti...

Uncertainty Analysis for Effective Dose Conversion Factors in CT

Authors: Renxin Chu, Jelena Mihailovic, Kai Yang, Lifeng Yu, Da Zhang

Affiliation: Massachusetts General Hospital, Mayo Clinic, Boston Children's Hospital, UVA Health University Hospital, University of Missouri Health Care

Abstract Preview: Purpose:
A frequently used method to estimate effective dose (ED) in CT is by multiplying the dose length product (DLP) by a conversion factor, known as k-factor. The k-factor in this method is sus...

Universal Range Modulators for Flash Proton Therapy: 3D Printing of Stackable Variable Density Units

Authors: Eric S. Diffenderfer, Lei Dong, Alejandro Garcia, Wenbo Gu, Michele M. Kim, Alexander Lin, Kai Mei, Peter B. Noël, Boon-Keng Kevin Teo, Lingshu Yin, Jennifer Wei Zou

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: We present a novel 3D-printed range-modulating devices with spatially modulated density for FLASH particle therapy. By varying density distributions, spread-out Bragg peaks(SOBPs) can be gene...

Use of Radiopaque Rectal Spacer for IGRT – a Preliminary Analysis of Alignment Accuracy and Interobserver Variability

Authors: Joseph A. Miccio, Nicholas J. Potter, Zain Siddiqui

Affiliation: Penn State Health Milton S. Hershey Medical Center

Abstract Preview: Purpose: Fiducial markers are the gold standard for prostate alignment during CT-based image-guided radiotherapy (IGRT). Radiopaque hydrogel rectal spacers reduce rectal toxicity by displacing the rec...

Validation and Benchmarking of Mirdct Software for Organ Dose Estimation in Routine CT Protocols

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...

Validation of Updated CT-to-SPR Calibration Method with Icrp-145 Data for Carbon-Ion Radiotherapy

Authors: Min Cheol Han, Soorim Han, Chan Hyeong Kim, Jin Sung Kim, Seok-Ho Lee, Gahee Son, Yongdo Yun

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The stoichiometric calibration method proposed by Kanematsu et al. (2016) has been widely adopted for CT number to stopping-power ratio (SPR) conversion in carbon-ion radiotherapy. With the r...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...

Visualization of Irradiation Field in Carbon-Ion Therapy By Openpet: Preliminary Analysis of Clinical Data

Authors: Go Akamatsu, Hiroaki Ikawa, Yuma Iwao, Han Gyu Kang, Masashi Koto, Hideyuki Mizuno, Akram Mohammadi, Makoto Shinoto, Minoru Tajiri, Hideaki Tashima, Chie Toramatsu, Taiga Yamaya

Affiliation: National Institutes for Quantum Science and Technology

Abstract Preview: Purpose: In-beam positron emission tomography (PET), in which positron emitters produced through fragmentation reactions are visualized, is a practical method for range verification in particle therap...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...