Search Submissions 🔎

Results for "different calculation": 55 found

A Comparative Evaluation of CT Global Noise Calculation Methods for Upcoming CMS Image Quality Measure

Authors: Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The recently introduced CMS regulation on CT dose and image quality mandates the use of global noise as the metric for image quality assessment. The regulation cites two methods for calculati...

A Framework for the Standardization of Radiomics Classes in the Presence of Blur and Noise

Authors: Huay Din, Grace Jianan Gang, Grace Hyun Kim, Michael F. McNitt-Gray, Joseph W. Stayman, Yijie Yuan

Affiliation: Johns Hopkins University, John Hopkins University, University of Pennsylvania, David Geffen School of Medicine at UCLA

Abstract Preview: Purpose:
Radiomics rely on quantitative features to discern underlying biological signatures. However, feature dependence on the imaging systems themselves hampers the creation of reproducible and ...

A New Way to Assess Dynamic Response of Centrally Located Lung Cancer (CLLC) to SBRT and Conventional Radiation Therapy (CRT)

Authors: Nina Burbure, Tawfik Giaddui, Shidong Li, Curtis Miyamoto, Jeremy Price, Bin Wang

Affiliation: FCCC at Temple University Hospital, Dept. of Radiation Oncology, Fox Chase Cancer Center at Temple University Hospital

Abstract Preview: Purpose: Higher rates of local failures and toxicities challenged radiation therapy of centrally located lung cancer (CLLC). We assessed the treatment response by measuring the early changes of PET+ n...

A Novel Approach to Preclinical Intensity-Modulated Radiotherapy Using an Open-Source Ring-Based Compensator Device and Inverse Treatment Planning System

Authors: Benjamin R. Awad, Bulent Aydogan, Howard J Halpern, Erik Pearson, Gage H. Redler, Jordan M. Slagowski, Rajit Tummala, Autumn E. Walter-Denzin, Jimmy Zydlo

Affiliation: University of Wisconsin-Madison Department of Human Oncology, University of Oxford, The University of Chicago, Moffitt Cancer Center, California State University, Fresno, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Small animal models are crucial in cancer research to develop, validate, and translate basic scientific hypotheses into clinical advancements. This study aims to make small animal intensity-m...

A Novel Multi-Material Decomposition Algorithm for Improved Material Quantification Using Dual-Energy CT

Authors: Dale Black, David Clymer, Huanjun Ding, Hamidreza Khodajou Chokami, Sabee Molloi, Christine Vy Nguyen, Tim Sananikone, Alireza Shojazadeh, Randy Wang

Affiliation: Department of Radiological Sciences, University of California, University of California, Department of Radiological Sciences, University of California, Irvine, Department of Radiological Sciences, University of California, Irvine

Abstract Preview: Purpose: We present a novel multi-material decomposition (MMD) algorithm for accurate quantification of material concentration in reconstructed dual-energy CT images. This method addresses limitations...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

An Accelerated Scatter Estimation for Spectral CBCT Based on Linear Boltzmann Transport Equation

Authors: Zhiqiang Chen, Hewei Gao, Li Zhang, Guoxi Zhu

Affiliation: Tsinghua University

Abstract Preview: Purpose: Spectral cone-beam CT has better performance in material identification and quantitative analysis compared to single-energy cone-beam CT. However, X-ray scattering introduces significant scat...

An Analytical Approach to Monitor Unit Calculation in Extended Distance Total Body Irradiation (TBI)

Authors: Cheewai Cheng, Indra J. Das, Jeffrey Yui Hei Wong, Poonam Yadav

Affiliation: Northwestern Memorial Hospital, Northwestern University Feinberg School of Medicine

Abstract Preview: Purpose: Radiation treatment machine replacement brings chaos and urgency of timely completion of machine commissioning for every procedure used including TBI that are time consuming. Based on past ex...

Analytical Approach to Calculate Normal Tissue Complication Probability and Tumor Control Probability for Ultra-High Dose Rate Radiation (FLASH) Based on Linear-Quadratic Model

Authors: Santosh K. Agarwalla, Nrusingh C. Biswal, Shree C, Harikrishnan Suresh Kumar, Jajati K. Nayak, Prema P., Sarath K S, Tamil Selvan S, Hem D. Shukla

Affiliation: Variable Energy Cyclotron Centre, Department of Physics, Fakir Mohan University, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Sciences, Amrita Vishwa Vidyapeetham

Abstract Preview: Purpose: The rapid oxygen depletion in tissues during irradiation is the most accepted mechanism of the FLASH effect. However, the Normal Tissue Complication Probability (NTCP) and Tumor Control Proba...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

Characterization and Validation of Cerenkov Radiation Extraction Methods from a Plastic Scintillation Detector in 0.35T MR-Linac Environments

Authors: Mateb Ali Alghamwa, Haya Aljuaid, Siyong Kim, Tianjun Ma, William Song

Affiliation: Virginia Commonwealth University

Abstract Preview: Purpose: The integration of Plastic Scintillation Detectors (PSDs) into 0.35T MR-Linac systems represents a significant advancement in radiotherapy, offering substantial benefits due to their tissue-e...

Characterizing the Stability of Upright CT for Proton Therapy

Authors: Brian Burger, Carri K. Glide-Hurst, John W. Hayes, Carson Hoffman, Minglei Kang, Jessica R. Miller, Jordan M. Slagowski, Yuhao Yan

Affiliation: Department of Human Oncology, University of Wisconsin-Madison, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Leo Cancer Care

Abstract Preview: Purpose: The combination of upright CT and patient positioner for particle therapy present tremendous potential for high precision IGRT and online adaptive radiation therapy (ART), where reliable CT p...

Clinical Validation of Fully Automated Script for Plan Conversion between Linacs with Different Mlc Model

Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin

Affiliation: NYU, NYU Langone Health

Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models

Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Commissioning and Validation of Monaco Proton Treatment Planning System on a Compact Proton Therapy System

Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Compact Representation of External Beam Photon Phase Space Data Via Implicit Neural Representation Learning

Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...

Comparison of CBCT Dose Calculation Accuracy between Truebeam Hypersight Image Reconstruction Algorithms

Authors: Sarah Aubert, Harald Keller, Jeff D. Winter

Affiliation: Princess Margaret Cancer Centre

Abstract Preview: Purpose: Support for treatment planning directly on CBCT imaging on C-arm linacs will enable adaptive radiation therapy (ART) capacity with increased treatment technique flexibility. The HyperSight im...

Dependency of CT Number on Position in the Field-of-View for Single- and Multi-Energy Images Acquired with Energy-Integrating-Detector and Photon-Counting-Detector CT Scanners

Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Development of Cross-Platform Application for Radiation Contamination Assessment

Authors: Wesley E. Bolch, Lotem Buchbinder Shadur, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Shaheen Dewji, John Francis, Emmanual Mate-Kole, Wyatt Smither, Yitian Wang

Affiliation: Georgia Tech, University of Florida, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology

Abstract Preview: Purpose: Develop a software application capable of assessing the radiation contamination of military service members and members of the general public for fast, on-site radiological triage. The softwa...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Efficient Monte Carlo Simulation of Radiation-Induced Double Strand Break Production and Repair Kinetics

Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal, Chris C. Wang

Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology

Abstract Preview: Purpose: Radiobiological simulation via TOPAS-nBio requires significant computational resources and time to provide meaningful results. This study aims to decrease simulation time and computational re...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of Four Different Dose Calculation Algorithms for Commissioning of a New Tyoe of Scanned Proton Therapy System

Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga

Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University

Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...

Evaluation of a Commercially Available Solution for Dose Verification Using Daily AI Generated Pseudo-CT from CBCT.

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.

Methods: Dose calculations in water phan...

Evaluation of the Dosimetric Characteristics of Multi-Layers of Brass Mesh Bolus for Electron Treatment

Authors: Yunzhi Ma, Ling Zhuang

Affiliation: Northwestern Medicine

Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...

FMEA for Optimizing Patient-Specific QA Program in IMRT: Insights from Diverse Practices

Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg

Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington

Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...

Getting in Focus: Review of Current Focal Spot Size Testing Methods with Flat Panel Digital Radiography Detectors

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose:
Historically film has been the gold standard receptor for measurements of x-ray tube focal spot size. Flat Panel Digital Radiography Detectors (FPDRDs) have lower spatial resolution compar...

Icrp Mesh-Type Reference Computational Phantoms Representing Pregnant Women and Fetuses

Authors: Wesley E. Bolch, Chansoo Choi, Chan Hyeong Kim, Suhyeon Kim, Bangho Shin, Yeon Soo Yeom

Affiliation: Hanyang University, University of Florida, 2) Department of Radiation Convergence Engineering, Yonsei University

Abstract Preview: Purpose: Task Group 103 of International Commission on Radiological Protection (ICRP) recently released new-generation adult and pediatric mesh-type reference computational phantoms (MRCPs) via ICRP P...

Impact analysis of effective dose conversion factors from CT scanner models

Authors: Max Chen, Sean Marquardt, Ben Yang, Kai Yang

Affiliation: Cary Academy, Massachusetts General Hospital, Winchester High School

Abstract Preview: Purpose: To analyze the impact of scanner model variation on the effective dose conversion factor (“k-factor”), which is most commonly used for CT effective dose calculation.

Methods: The stand...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

Improvements of Lateral Penumbra at Various Depth Regions in Scanned Proton Treatment System with a Multi-Leaf Collimator: Dose Verifications and Plan Comparisons

Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka

Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University

Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...

Inconsistencies in Methods for CMS Size-Adjusted Dose Measure

Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Inter-Patient Adaptive Radiotherapy (IPART): A CT Simulation and Planning Free Approach Enabling Immediate Treatment Access for Patients.

Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...

Mesh-Based Multiregion Model of Adult Human Kidneys for Dosimetric Evaluation of Radiopharmaceutical Therapy

Authors: John P. Aris, Wesley E. Bolch, Chansoo Choi, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Abdul-Vehab Dozic, Amy M. Geyer, Harald Paganetti, Shreya P. Pathak, Julia D. Withrow

Affiliation: St. Luke's Health System, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: The goal of this study was to enhance the accuracy of renal dosimetry in radiopharmaceutical therapy (RPT) by developing a more detailed and precise kidney model. In RPT, accurate dose estima...

Mobetron Quality Assurance Tools

Authors: Robert A. Dahl

Affiliation: Mayo Foundation

Abstract Preview: Purpose: To develop tools to simplify/accelerate the quality assurance testing of the Mobetron mobile linear accelerator and increase safety when moving it to different OR’s.

Methods: The Mobet...

Photon-Proton Treatment Compatible Couch Tops Render Modality-Dependent Support Structure Models

Authors: Estelle Batin, Michael A. Carlson, Nilendu Gupta, Zachary X. Richards, Diana Shvydka

Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center

Abstract Preview: Purpose: With an increase in world-wide proton treatment availability, patients sometimes are transferred between proton and photon modalities. Among the main reasons for modality shifts are proton be...

Proton Minibeam Radiotherapy: Commissioning, Treatment Planning, and Delivery

Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung

Affiliation: Mayo Clinic - Rochester

Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...

Quantifying Uncertainties in Radiation Risk and Performance-Based Clinical Risk Assessment in Clinical Computed Tomography

Authors: Em Harkness, Francesco Ria, Ehsan Samei

Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System

Abstract Preview: Purpose:
A recently introduced mathematical method quantifies performance-based clinical risk to create a risk-to-risk assessment with radiation risk, rendering the so-called total risk. However, t...

Radiobiological Calculations of Daily Doses Using Pseudo CT (pCT)

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose:
To calculate radiobiological metrics of daily dose delivered for head and neck (HN) patients using the daily cone beam CT (CBCT) to generate a pseudo CT (pCT). Moreover, this work compares...

Real-Time Automatic Treatment Planning System (RT-AutoTPS) for Volumetric Modulated Arc Radiotherapy (VMAT)

Authors: Steve B. Jiang, Austen Matthew Maniscalco, Dan Nguyen, Chenyang Shen, Jiacheng Xie, Shunyu Yan, Ying Zhang, You Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas

Abstract Preview: Purpose: Although treatment planning systems (TPSs) can handle dose calculation and plan optimization automatically, planning for radiotherapy still requires extensive efforts and expertise from a mul...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Streamlined Proton Registry Interface for Patient Subtyping and Assessment Integration

Authors: Curtiland Deville, Rachel B. Ger, Elaina Hales, Heng Li, Todd R. McNutt

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Lack of specialized coding knowledge limits the use of data from large SQL repositories. We aimed to develop intuitive user interfaces for a registry that allows users to visualize the relati...

Streamlining Linac Mechanical QA Workflow with Javascript and Customizable PDF Templates

Authors: Sean P. Devan, Cory S. Knill, Choonik Lee, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Tools such as step-by-step instructions, checklists, and automated calculations can improve process efficiency, mitigate errors, and facilitate standardization across different users and clin...

Time-Efficient Photon Plan Checks with Esapi-Based Software

Authors: Kevin Peter Risolo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...

Treatment Planning System Modelling of a New Commercial Rotational Table

Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan

Affiliation: Mayo Clinic Arizona, Mayo Clinic

Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.

Methods: A commercial rotational table (CDR Equilibrium®) is r...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...