Search Submissions 🔎

Results for "different institutions": 27 found

A Method to Expedite Quality Assurance for Head and Neck Ctvs with Lymph Node Level Auto-Autocontouring and Identification

Authors: Beth M. Beadle, Adrian Celaya, Laurence Edward Court, David Fuentes, Anna Lee, Tze Yee Lim, Dragan Mirkovic, Amy Moreno, Raymond Mumme, Tucker J. Netherton, Callistus M. Nguyen, Jaganathan A Parameshwaran, Jack Phan, Carlos Sjogreen, Sara L. Thrower, Congjun Wang, He C. Wang, Xin Wang

Affiliation: Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center; The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Department of Radiation Oncology, Stanford University, The University of Texas MD Anderson Cancer Center, MD Anderson Cancer Center, MD Anderson, Rice University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Quality assurance of target volumes from radiotherapy clinical trials is a labor and resource intensive task. The purpose of this work is to quantify the accuracy of a tool that automatically...

A Multi-Institutional Survey of Current Therapeutic Medical Physics Residents’ Satisfaction and Interview Experience

Authors: Seifallah Emam, Gilberto Gonzalez, Anna E. Rodrigues

Affiliation: Duke University, University of Oklahoma Health Sciences Center

Abstract Preview: Purpose:
To survey current therapeutic medical physics residents on 1) the accuracy with which residency programs were represented during interviews, 2) factors that most strongly impacted resident...

A Novel Cost-Effective Customizable 3D-Printed Thoracic Phantom for End-to-End Treatment Verification and Image Quality Assessment

Authors: Reza Farjam, Russell K Hales, Seth Jayawardane, Todd R. McNutt, Mohammad Rezaee, Ehsan Tajikmansoury, K. Ranh Voong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University, Department of Biomedical Engineering, Johns Hopkins School of Medicine

Abstract Preview: Purpose: This study presents a novel cost-effective customizable 3D-printed phantom developed for end-to-end treatment verification and image-quality assessment for thoracic applications.
Methods: ...

A Python Package for GPU-Accelerated Photon Dose Calculation for Advanced and Generalizable Auto-Planning Approaches: Validation for Multiple Linear Accelerator Vendors and Institutions

Authors: Jaryd Ricardo Christie, Anthony J. Doemer, William T. Hrinivich, Junghoon Lee, Calin Reamy, Kundan S Thind

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Henry Ford Health

Abstract Preview: Purpose: To develop and validate an open-source Python package for fast, widely compatible, and user-friendly photon dose calculation algorithm through comparisons with clinical treatment planning sys...

Advancing Flash Radiotherapy: Intercomparison of Parameters between Two Institutions to Optimize Clinical Applications.

Authors: Amir Abdollahi, Celine Karle, Michele M. Kim, Constantinos Koumenis, Andrea Mairani, Erato Stylianou Markidou

Affiliation: Heidelberg Ion-Beam Therapy Center - Department of Radiation Oncology, German Cancer Research Centre(DKFZ), University of Pennsylvania, Physics Dep. University of Cyprus

Abstract Preview: Purpose: The aim is to compare FLASH dose-rate RT generated with protons and carbon (HIT) and compare to protons (UPenn) to provide evidence for equipotency of FLASH vs. standard RT to tumor growth co...

Bridging the Gap of Radiotherapy Planning Quality between a High-Income Countrie to a Middle-Income Country By the Dosimetric Validation of a KBP Model Vs Junior, Senior Dosimetrists and MCO Planning

Authors: Eduardo Florian, Hiram Gay, Geoffrey D. Hugo, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Francisco Javier Reynoso, Edgar Aparicio Ruiz, Baozhou Sun, Jacaranda Van Rheenen, Kevin Vega, Angel Velarde, Vicky de Falla

Affiliation: WashU Medicine, Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Washington Univ. in St. Louis, Liga Nacional Contra el CĂĄncer / INCAN, Washington University in St. Louis, Varian, Baylor College of Medicine

Abstract Preview: Purpose:
IMRT has become the standard of care in high-income countries (HICs) due to reduced toxicity and improved treatment outcomes.
The purpose of this work is validating the KBP model shared...

Clinical Validation of Fully Automated Script for Plan Conversion between Linacs with Different Mlc Model

Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin

Affiliation: NYU, NYU Langone Health

Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models

Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...

Comparison of Computed Tomography Scanner Protocols Using an in-House Automated Method across Machines at a Single Institution

Authors: Matthew R. Hoerner, Maryam Naseri, Mena Shenouda

Affiliation: Yale University School of Medicine, Yale University

Abstract Preview: Purpose: To evaluate acquisition parameters of computed tomography (CT) scanner protocols across different machines to provide patients and clinicians consistent care and image quality, respectively.<...

Comprehensive Analysis of Plan Modulation in SRS/SBRT Plans: A Single Institution Study of 461 Cases

Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...

Confidence in a Tattoo-Less Transition

Authors: Laura A. Doyle, Amy S. Harrison, Allyson P Koecher, Jackson D Reeves, Lindsay B Romak

Affiliation: Christiana Care

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) is increasingly utilized in radiation oncology, allowing for transition away from permanent skin marks to SGRT-based daily treatment setup. Following i...

Development and Evaluation of Fat Fraction Reference Materials for Magnetic Resonance Imaging

Authors: Hyo-Min Cho, Cheolpyo Hong, Changwoo Lee, Sunyoung Lee

Affiliation: Daegu Catholic University, Korea Research Institute of Standards and Science (KRISS), Korea Research Institute of Standards and Science

Abstract Preview: Purpose: With the increasing prevalence of metabolic syndrome, the importance of diagnosing obesity and fatty liver diseases has grown significantly. As a result, there is a rising demand for non-inva...

Development of a Method to Standardize Multi-Institutional Quality Assurance Data through an AI Based Language Model Ontology.

Authors: Rafe A. McBeth, Ayoola Okuribido, Rodney D. Wiersma

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: To develop a method for standardizing data collected during quality assurance checks across institutions using language models.
Background: QA procedures and data management can vary widel...

Development of a Method to Standardize Multi-Instiutional Quality Assurance Data through an AI Based Language Model Ontology.

Authors: Rafe A. McBeth, Ayoola Okuribido, Rodney D. Wiersma

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA

Abstract Preview: Purpose: To develop a method for standardizing data collected during quality assurance checks across institutions using language models.
Background: QA procedures and data management can vary widel...

Evaluating the Interchangeability of Two Similar but Not Beam-Matched Varian Truebeam Linear Accelerators in the Delivery of Patient-Specific Quality Assurance

Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian

Affiliation: Rush University Medical Center

Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...

Experience in Commissioning and Quality Assurance of Halcyon Linear Accelerator Ver3.0 at a Community Hospital and an Academic Institution

Authors: Emily Y. Hirata, Xiaoyu Sherry Liu, Evan Porter, Manju Sharma

Affiliation: University of California San Francisco, University of California, San Francisco, University of California

Abstract Preview: Purpose:
The Varian Halcyon Linear Accelerator has become increasingly popular in both community hospitals and academic institutions due to its user-friendly design and operational efficiency. This...

Failure Mode and Effects Analysis (FMEA) on Use of Surface Guided Imaging

Authors: Victoria Noelle Bry, Tamara Egan, Eric C. Ford, Angelia Landers, Juergen Meyer

Affiliation: Fred Hutch Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Washington

Abstract Preview: Purpose: Surface guided radiation therapy (SGRT) can improve patient safety, however, its complex integration may expose processes to increased risk of error. This work identifies potential failures f...

Impact of a Dedicated Working Group on Standardization of CT-Guided Adaptive Radiation Therapy

Authors: Anthony J. Doemer, Aharon Feldman, Ian Gallagher, Yimei Huang, Brett M. Miller, Benjamin Movsas, Kundan S Thind

Affiliation: Henry Ford Health

Abstract Preview: Purpose: CT-guided adaptive radiation therapy (CTgART) is a technical, resource intensive, procedure that involves many different radiation oncology team members. To ensure consistent, high-quality CT...

Improving the Robustness of AI-Based Detection and Segmentation for Brain Metastasis By Optimizing Loss Function and Multi-Dataset Training

Authors: Omar Awad, Alfredo Enrique Echeverria, Issam M. El Naqa, Daniel Allan Hamstra, Yiding Han, Ryan Lafratta, Abdallah Sherif Radwan Mohamed, Piyush Pathak, Zaid Ali Siddiqui, Baozhou Sun, Vincent Ugarte

Affiliation: H. Lee Moffitt Cancer Center, Harris Health, Baylor College of Medicine

Abstract Preview: Purpose:
Accurate detection and segmentation of brain metastases are critical for diagnosis, treatment planning, and follow-up imaging but are challenging due to labor-intensive manual assessments ...

Inconsistencies in Methods for CMS Size-Adjusted Dose Measure

Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang

Affiliation: University of Kentucky

Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...

Influence of Intrafraction Motion on the Dosimetry of Prostate Treatments

Authors: María Fernåndez, Inés Flores, Nuria Montero, Manuel Ruiz, Francisco San Miguel

Affiliation: Hospital Central de la Defensa 'GĂłmez Ulla', Hospital Central de la Defensa "Gomez Ulla", CSVE, Hospital Central de la Defensa 'GĂłmez Ulla', CSVE

Abstract Preview: Purpose:
During external radiotherapy treatments in the prostate, there can be PTV movements between fractions and during each treatment fraction. In a typical prostate treatment in our institution...

Medical Physics Postdoctoral Research As an Entrée into the Profession: Results of a Survey Administered By the AAPM Medical Physics Graduate Education Subcommittee

Authors: Abdullah A. Alshreef, Elizabeth L. Bossart, Ashley Cetnar, Leonard H. Kim, Neil A. Kirby, Anna E. Rodrigues, Xin Wang, You Zhang

Affiliation: University of Miami, The University of Texas MD Anderson Cancer Center, Loma Linda University Medical Center, MD Anderson Cancer Center at Cooper, Cooper Medical School of Rowan University, The Ohio State University - James Cancer Hospital, UT Health San Antonio, Duke University, 5940 forest park road

Abstract Preview: Purpose: AAPM TG-298 reported several concerns regarding the training and education of alternative pathway candidates. Medical physics postdoctoral research, though not part of the certification pathw...

Multi-Center Diffusion-Weighted MRI Validation for 0.35T MR-Linac: A Repeatability and Reproducibility Study

Authors: Tess Armstrong, Nema Bassiri, Alonso N. Gutierrez, Michael Kasper, Natalia Lutsik, Eric Mellon, Kathryn E. Mittauer, Siamak P. Nejad-Davarani, Shyam Pokharel, Suresh Rana, Hui Wang, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, Miami Cancer Institute, Baptist Health South Florida, ViewRay, Inc., Miami Cancer Institute, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida, Department of Radiation Oncology, University of Miami

Abstract Preview: Purpose: Radiation treatments on the MR-linac (MRL) enable daily acquisition of anatomical and physiological images for adaptive treatment planning. The apparent diffusion coefficient (ADC) estimated ...

Multi-Institutional Analysis of CT Dose Index Variability and Radiomics Features

Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati

Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...

Multi-Institutional Evaluation of Radiographic Automatic Exposure Control Performance Testing: Methodology, Outcomes, and Failure Rates

Authors: Caroline Cheney, Nicole M. Lafata, Zaiyang Long, Dustin W. Lynch, Erin B. Macdonald, Andy Madore, Douglas E. Pfeiffer, Colin Schaeffer, Alexander W. Scott

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, UVA Health, Duke University Health System, Mayo Clinic, Henry Ford Health, Boulder Community Health, Varian, Cedars-Sinai Medical Center

Abstract Preview: Purpose: This work evaluates the significance of performing established radiography automatic exposure control (AEC) tests by comparing testing methodology, outcomes, and failure rates across multiple...

Temporal Drift in Ir-192 Source Strength Measurements: A Braphyqs Multi-Center Analysis

Authors: Åsa K. Carlsson Tedgren, Taran Hellebust, Antonio Herreros, Jacob Johansen, Christian Kirisits, Panagiotis Papagiannis, Mark J. Rivard, Frank-Andre Siebert, Frank Verhaegen, Javier Vijande, Jan Wiersma, Marisol de Brabandere, Ruud van Leeuwen

Affiliation: UKSH, Campus Kiel, Klinik fĂŒr Strahlentherapie (Radioonkologie), Department of Oncology, The Norwegian Radium Hospital, Oslo University Hospital, Radiation Physics, Department of Medicine and Health (IMH), Linköping University, Radiation Oncology Department, Hospital ClĂ­nic-Universitat de Barcelona, IDIBAPS, IFIC-UV, Radiation Oncology, Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Radboud University Medical Center, Department of Oncology, Aarhus University Hospital, University Hospital Gasthuisberg, Dept. of Radiation Oncology, Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: This study, which was carried out by the GEC-ESTRO BRAPHYQS working group, reports the increasing divergence between clinical reference air kerma rate (RAKR) measurements and vendor-provided ...

Time-Efficient Photon Plan Checks with Esapi-Based Software

Authors: Kevin Peter Risolo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...

Validation of an Independent Dose Calculation Software for ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich

Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...