Search Submissions 🔎

Results for "dimensional computed": 16 found

4D CBCT Reconstruction Using Denoising Diffusion Implicit Models

Authors: Weixing Cai, Laura I. Cervino, Yabo Fu, Bohong Huang, Licheng Kuo, Tianfang Li, Xiang Li, Jean M. Moran, Huiqiao Xie, Hao Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) is critical in image-guided radiotherapy (IGRT) for visualizing tumor motion. However, sparse projection sampling often introduces sev...

A Novel Feature Selection Method for Survival Prediction of Head-and-Neck Following Radiation Therapy

Authors: Xiaoying Pan, X. Sharon Qi

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, School of Computer Science and technology,Xi'an University of Posts and Telecommunications

Abstract Preview: Purpose:
Survival prediction for cancer presents a substantial hurdle in personalized oncology, due to intricate, high-dimensional medical data. Our study introduces an innovative feature selection...

A Novel Semi-Analytic Approach for Dose Calculation in Proton Minibeam Radiotherapy

Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...

Automated Parametric Custom Collimator Creation for Preclinical Irradiation Studies

Authors: Muhammad Ramish Ashraf, Dixin Chen, Lloyd Emmanuel Kamole Ghomsi, Edward Elliot Graves, Billy W Loo, Stavros Melemenidis, Joseph B. Schulz, Lawrie Skinner

Affiliation: Department of Radiation Oncology, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: Precise beam collimation is essential in preclinical radiotherapy studies to ensure accurate dose delivery. Manual design and fabrication of organ-specific collimators usually consist of mult...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Deep Autoencoder for Ring Artifact Denoising in Photon-Counting CT

Authors: Magdalena Bazalova-Carter, James Day, Xinchen Deng

Affiliation: University of Victoria

Abstract Preview: Purpose:
Ring artifacts in Photon-Counting Computed Tomography (PCCT) images can degrade image quality. this study aims to suppress ring artifacts with a novel autoencoder-based framework that leve...

Dose Mapping of Radioactive Gold Nanoparticles Using Three-Dimensional Dosimetry

Authors: Ana Laura Burin, Maysa Müller Ferreira Gesserame, David Alexander Urbina Leal, Ilca Marli Moitinho Amaral Medeiros, Silas Leonel Pereira Miranda, Thuany Corrêa Nogueira, Maria da Penha Alburquerque Potiens, Pedro Henrique Ricardo, Maria Eduarda Zaganin Rigo, Orlando Rodrigues, Priscila Santos Rodrigues, Wilmmer Alexander Arcos Rosero, Maria Elisa Chuery Martins Rostelato, Sabrina Spigaroli Sgrignoli, Ana Catarina Koka de Souza Silva, Cristhian Ferreira Talacimon, Paulo Victor dos Santos Tavares, Lara El Hajj Teodoro, Carlos Alberto Zeituni, José Neres de Almeida

Affiliation: IPEN - USP

Abstract Preview: Purpose: Perform three-dimensional dosimetry of radioactive gold nanoparticles (¹⁹⁸AuNPs) using Fricke xylenol gel (FXG), aiming to determine the dose distribution and evaluate the method's effectiven...

Enhanced Lung Function Assessment through Machine Learning Analysis of 4DCT Subregional Respiratory Dynamics

Authors: Jing Cai, Zhi Chen, Hong Ge, Yu-Hua Huang, Bing Li, Zihan Li, Ge Ren

Affiliation: Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, The Affiliated Cancer Hospital of Zhengzhou University and Henan Cancer Hospital

Abstract Preview: Purpose: Algorithms based on subregional respiratory dynamics (SRD) capture spatiotemporal heterogeneity in the ventilation process, though rely on empirical modelings to map surrogate ventilation. Gi...

Evaluation of an Analytical Simulation Technique By Comparing Transmitted Spectra Against GEANT4 through a Hafnium-Loaded Heterogeneous Phantom

Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...

First Demonstration of Prostate Radiotherapy Plan Optimization on an IBM Quantum Computer

Authors: Keisuke Fujii, Masahiro Kitagawa, Arezoo Modiri, Yuichiro Nakano, Ken N. Okada, Robabeh Rahimi, Akira SaiToh, Amit Sawant, Satoyuki Tsukano, Baoshe Zhang

Affiliation: University of Maryland, University of Maryland in Baltimore, Department of Computer and Information Sciences, Sojo University, Center for Quantum Information and Quantum Biology, Osaka University, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: Fully personalized radiotherapy requires computational resources far exceeding those of conventional CPU/GPU systems. This study explores the use of quantum computing (QC) in radiotherapy pla...

Four-Dimensional Computed Tomography Based on 16cm-Long Detectors Vs 4cm-Long Detectors: Dose Validation

Authors: Qianyi Xu, Inhwan Yeo

Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University

Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...

Four-Dimensional on-Beam Computed Tomography Reconstruction from Projection Image Differences Representing Motion Change

Authors: Kwang-Ho Cheong, Seungryong Cho, Joonil Hwang, Jae Won Jung, Hoyeon Lee, Raymond Hyunwoo Moon, Inhwan Yeo, Jihyung Yoon

Affiliation: East Carolina University, INOVA Schar Cancer Institute, University of Hong Kong, Hanllym University, KAIST, University of Rochester

Abstract Preview: Purpose: Monitoring a target and neighboring organs during beam delivery is crucial for successful radiotherapy (RT). Conventional transit imaging methods lack volumetric reconstruction capabilities, ...

Frameless and Maskless Stereotactic Radiosurgery: Evaluating a Novel Robotic Head Motion Compensation Device

Authors: Michelle Alonso-Basanta, Carl Denis, Wenbo Gu, Xinmin Liu, Ahmad Sakaamini, Rodney D. Wiersma

Affiliation: UCLA, University of Pennsylvania, CDR Systems

Abstract Preview: Purpose: Stereotactic radiosurgery (SRS) is a non-invasive technique used to treat functional abnormalities and small brain tumors. Traditional SRS relies on a rigidly fixed metal head ring, causing d...

Quality Assurance of Four-Dimensional Computed Tomography (4DCT)

Authors: Teh Lin, Anna Oneil

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Four-dimensional computed tomography(4DCT) is often required to assess organ motions for thoracic and abdominal cancer patients. This study proposes a quality assurance (QA) procedure for two...

Simultaneous Synthesis of Lung Perfusion and Ventilation Images from CT Using a Dual-Decoder Residual Attention Network for Lung Disease Diagnosis

Authors: Li-Sheng Geng, David Huang, Haoze Li, Xi Liu, Meng Wang, Tianyu Xiong, Ruijie Yang, Weifang Zhang, Meixin Zhao

Affiliation: School of Physics, Beihang University, Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Department of Radiation Oncology, Peking University Third Hospital, Department of Nuclear Medicine, Peking University Third Hospital, Medical Physics Graduate Program, Duke Kunshan University

Abstract Preview: Purpose: This study aimed to develop a deep learning-based framework for simultaneously generating lung perfusion and ventilation images from three-dimensional computed tomography (3D CT) images.
M...

Tumor Density on Time-Weighted Mid-Position Images for Thoracic Tumors

Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai

Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...