Authors: Nebi Demez, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Nishan Shrestha
Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose: Treatment plans on the ViewRay MRIdian are often planned with the target placed off isocenter due to the proximity of the bore to the patient, allowing for limited shifts. This is especially ...
Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts
Affiliation: University of Michigan, Oregon Health & Science University
Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...
Authors: Josephine Chen, CheukKai Becket Hui, Yildirim D. Mutaf
Affiliation: Kaiser Permanente
Abstract Preview: Purpose:
To demonstrate the effectiveness of a target clustering program in generating cluster configurations and isocenter placements for multiple brain lesions in SRS treatment planning, with the...
Authors: Matthew Stephen Andriotty, Taoran Cui, Josh Kilian-Meneghin, Ke Nie, Xiao Wang, Zhenyu Xiong, Ning J. Yue, Yin Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, RWJBarnabas Health
Abstract Preview: Purpose: To investigate the potential impact of the Elekta Unity’s 1.5T magnetic field upon the performance of a conventional linac installed in an adjacent vault.
Methods: The linac vaults for thi...
Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park
Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital
Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...
Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou
Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation
Abstract Preview: Purpose: A new CT configuration utilizing a multiple X-ray-source array (MXA) is under development to mitigate cone-beam (CB) artifacts in single-rotation wide coverage imaging. We investigate the sam...
Authors: Imad M. Ali, Nesreen Alsbou, Baraa Kalani
Affiliation: Oklahoma State University, University of Central Oklahoma, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: To develop a three-dimensional Winston-Lutz phantom to quantify the isocentricity of the gantry, couch, and on-board imager of the MEVION-S250i proton therapy machine.
Methods: A 3D-scinti...
Authors: Tanxia Qu, Hesheng Wang
Affiliation: NYU Langone Health
Abstract Preview: Purpose:
This study, the second in a two-part series, evaluates the isocenter position (the point in 3D space minimizing the sum of Euclidean distances to the MLC's central axis) and isocenter size...
Authors: Christopher Ackerman, Chang Chang, Yansong Liu, Stephen Kenneth Northway, Bailey Vallejo
Affiliation: University of California San Diego / California Protons, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center
Abstract Preview: Purpose: To determine mechanical isocenter of a 6-degree-of-freedom (6DOF) couch using radiation isocenter. Coincidence between the isocenters is quantified using MyQA Phoenix amorphous silicon detect...
Authors: Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Michael Leyva, Alejandro Rene Llanes Lopez, William Romaguera, Ranjini P. Tolakanahalli, Deborah Wang
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health
Abstract Preview: Purpose: To evaluate whether a modulated electron bolus (MEB) technique improves both nominal and shifted dose distributions in nasal electron therapy as compared to a non‑modulated, uniform‑thickness...
Authors: Min Su
Affiliation: Mount Sinai School of Medicine
Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...
Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue
Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...
Authors: Blessing Chinelo Akah, Daniel W. Neck, David J. Perrin, Sotirios Stathakis
Affiliation: Mary Bird Perkins Cancer Center
Abstract Preview: Purpose: To assess the reliability of the Aktina Isopoint software in evaluating different components of the linear accelerator for optimized quality assurance and linac performance
Methods: The Ak...
Authors: Chunhui Han, An Liu, Anthony Magliari, Lesley Rosa
Affiliation: Office of Medical Affairs, Varian, A Siemens Healthineers Company, Department of Radiation Oncology, City of Hope National Medical Center
Abstract Preview: Purpose: To evaluate the performance of a knowledge-based planning (KBP) optimization model for total marrow and lymphoid irradiation (TMLI) on a ring-gantry linac with a dual-layer MLC and to evaluat...
Authors: Peter Balter, Thomas Alexander Cuthbert, Weiliang Du, Song Gao, Nicholas Zacharopoulos
Affiliation: Aktina Medical Corp, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: The purpose of this study is to evaluate the accuracy and reproducibility of a commercial product for verifying the size, location, and coincidence of physical isocenter (P_iso) and radiation...
Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin
Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...
Authors: Robert A. Corns, Mohammad Kanber
Affiliation: East Carolina University, East Carolina University Brody School of Medicine
Abstract Preview: Purpose:
Accurate determination of the radiation isocenter is crucial for precise radiotherapy treatments, directly impacting patient safety and treatment quality. This study presents a computation...
Authors: Anupama Chundury, Hyejoo Kang, John C. Roeske, Iris A. Rusu
Affiliation: Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose: To quantify the dosimetric impact of six degrees of freedom (6DoF) intrafractional errors on gross tumor volume (GTV) and planning target volumes (PTV) for single-isocenter multi-target stere...
Authors: Qihui Lyu, Javier Caravaca Rodriguez, Youngho Seo, Ke Sheng, Jingjie Yu
Affiliation: University of California San Francisco, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose:
Simultaneous broad-energy imaging is critical for many theragnostic applications, but the current Single-Photon Emission Computed Tomography (SPECT) can only image low energy photons with ...
Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang
Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...
Authors: Qihui Lyu, Dan Ruan, Ke Sheng, Jingjie Yu
Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California, San Francisco, Department of Radiation Oncology, University of California, San Francisco
Abstract Preview: Purpose: The robotic arm radiotherapy platform enables flexible delivery of non-coplanar and non-isocentric radiotherapy with variable Source-to-Isocenter Distances (SIDs). However, the high degrees o...
Authors: Jonathan Dowell, Wei Luo, Shane McCarthy, Janelle A. Molloy, Markus Murphy
Affiliation: University of Kentucky, Department of Radiation Medicine, Iridesce Solutions, Inc.
Abstract Preview: Purpose: The novel machine quality assurance (QA) device nüFilm (Iridesce Solutions, Lexington KY) allows for an objective assessment of light and radiation fields independent of setup. Herein, the ab...
Authors: Colton Baley, Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, Texas Oncology, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate the accuracy of off-axis winston lutz (WLT) for linac based stereotactic radiosurgery (SRS) treatments using in-house phantom.
Methods: Traditional WLT that uses cone and s...
Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao
Affiliation: Duke University, Duke Kunshan University
Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...
Authors: William G. Breen, Dalton Griner, Scott C Lester, Joseph John Lucido, Beth A. Schueler, Jack C. Thull
Affiliation: Mayo Clinic
Abstract Preview: Purpose: Designing a total skin electron (TSE) beam therapy protocol requires finding the optimal balance between penetration depth, field uniformity, and x-ray contamination (XC). To better understan...
Authors: Liang-Hsin Chen, Hsiang-Kuang Tony Linag
Affiliation: National Taiwan University Cancer Center, Department of Biomedical Engineering, National Taiwan University
Abstract Preview: Purpose: The characteristics of scanning proton beam is one of crucial factors to affect dose delivering accuracy in proton theray. Therefore, this study aims to evaluate and monitor the stability of ...
Authors: Shifeng Chen, Yannick P. Poirier, Huijun Xu, Byong Yong Yi, Baoshe Zhang, Hong Zhang, Jinghao Zhou
Affiliation: University of Maryland School of Medicine, University of Maryland Shore Regional Cancer Center, Vanderbilt University Medical Center, Department of Radiation Oncology, University of Maryland School of Medicine, Capital Region Medical Center
Abstract Preview: Purpose: To thoroughly assess the resilience of HyperArc VMAT plans for multiple brain metastases (MBT) in relation to (i) high-definition MLC leaf positional inaccuracies and (ii) patient rotational ...
Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich
Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center
Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...
Authors: Go Akamatsu, Hiroaki Ikawa, Yuma Iwao, Han Gyu Kang, Masashi Koto, Hideyuki Mizuno, Akram Mohammadi, Makoto Shinoto, Minoru Tajiri, Hideaki Tashima, Chie Toramatsu, Taiga Yamaya
Affiliation: National Institutes for Quantum Science and Technology
Abstract Preview: Purpose: In-beam positron emission tomography (PET), in which positron emitters produced through fragmentation reactions are visualized, is a practical method for range verification in particle therap...