Search Submissions 🔎

Results for "distribution profiles": 27 found

A Dosimetric Study of Range-Compensated Proton Arc Therapy

Authors: Alonso N. Gutierrez, Daniel E. Hyer, Blake R. Smith

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Iowa Health Care, University of Iowa

Abstract Preview: Purpose: To perform a feasibility study of optimizing and producing a compact range compensator to deliver single-energy pencil beam scanning (PBS) proton arc therapy treatments. Omitting energy chang...

A GPU Accelerated Monte Carlo Dose Engine for Small Animal Proton Radiotherapy

Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng

Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...

A Monte Carlo-Based Secondary Dose Verification Tool for Treatment Plans of Robotic Radiosurgery System

Authors: Chuxiong Ding, Xuejun Gu, Heejung Kim, Weiguo Lu, Yang Kyun Park, Yulong Yan

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine

Abstract Preview: Purpose: The purpose of this study was to develop and evaluate a Monte Carlo (MC) dose calculation software (DosemanCK) for secondary dose verification of CyberKnife (CK) treatment plans. Unlike tradi...

A Novel Semi-Analytic Approach for Dose Calculation in Proton Minibeam Radiotherapy

Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Compact Representation of External Beam Photon Phase Space Data Via Implicit Neural Representation Learning

Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang

Affiliation: Department of Radiation Oncology, Stanford University

Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...

Comparison of Mlc Off-Axis Characteristics for Eclipse AAA v18 and v16 Using Portal Dosimetry

Authors: Junsheng Cao, Khushdeep Singh

Affiliation: Overlook Medical Center

Abstract Preview: Purpose: Eclipse v18 introduces Enhanced Leaf Modeling for MLCs. This study investigates the MLC off-axis characteristics using portal dosimetry
Methods:
MLC characteristics were analyzed for th...

Dose Distribution Analysis for Different Geometries of a Multiple-X-Ray Source Array (MXA) CT Scanner

Authors: Craig K Abbey, John M. Boone, Richard E. Colbeth, Andrew M. Hernandez, Vance Robinson, Paul Schwoebel, Jeffrey H. Siewerdsen, Alejandro Sisniega, Wojciech B. Zbijewski, Huanyi Zhou

Affiliation: UC Santa Barbara, University of California, UT MD Anderson Cancer Center, Johns Hopkins University, University of New Mexico Albuquerque, UC Davis Health, Varex Imaging Corporation

Abstract Preview: Purpose: A Multiple-X-ray Source Array (MXA) for CT (MXA-CT) is under development to mitigate cone beam artifacts in axial CT scans using wide collimation. The purpose of this study is to assess the i...

Dose Reconstruction from Prompt-Gamma Imaging Towards Real-Time Adaptive Proton Therapy

Authors: Thomas R. Bortfeld, Prof. Elisabetta De Bernardi, Tianxue Du, Beatrice Foglia, Chiara Gianoli, Takamitsu Masuda, Katia Parodi, Marco Pinto, Boon-Keng Kevin Teo, Yunhe Xie

Affiliation: Department Of Radiation Oncology, Massachusetts General Hospital (MGH), School of Medicine and Surgery, University of Milano-Bicocca, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, National Institutes for Quantum Science and Technology (QST), University of Pennsylvania, Department of Experimental Physics - Medical Physics, Ludwig-Maximilians-Universität (LMU) München

Abstract Preview: Purpose: The full potential offered by protons in clinical practice is limited by range uncertainties. One possibility for monitoring is through secondary prompt gammas (PG). PG emission along the pen...

Dosimetric Parameters for Lattice Spatially Fractionated Radiotherapy (LRT) : Pros and Cons

Authors: Lining Chen, Zhitao Dai, Shumei Jia, Yajun Jia, Enzhuo Quan

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: This work reviewed 12 patient clinical LRT treatments in physics view including geometric and dosimetric parameters and discussed the pros and cons related to the latter.
Methods: Geometri...

Dynamic 2.5D Surface Dosimetry Using Deformable Scintillator Array Imaging

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Lesley A Jarvis, Allison Matous, Roman Vasyltsiv, Rongxiao Zhang

Affiliation: Dartmouth Health, Dartmouth College, Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, University of Missouri

Abstract Preview: Purpose: On-patient dosimeters assist in clinical decision-making by measuring surface dose, but single-point measurements cannot monitor area-wide distributions and are misleading in high-gradient re...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Fast Monte Carlo Secondary Dose Calculation for Intensity Modulated Proton Therapy in Heterogeneous Materials

Authors: Ergun E. Ahunbay, Abdul Kareem Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao

Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Secondary dose calculations (SDC) facilitate patient-specific quality assurance for online adaptive intensity-modulated proton therapy (IMPT). However, there is currently a lack of commercial...

Evaluation of a Commercially Available Solution for Dose Verification Using Daily AI Generated Pseudo-CT from CBCT.

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.

Methods: Dose calculations in water phan...

GPU Accelerated Monte Carlo Simulation for Tset Dose Calculation

Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu

Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania

Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...

GPU-Accelerated Beamlet and Full Dose Calculations for Efficient Radiation Therapy Planning

Authors: Girish Bal, Jan Kralj, Ayan Mitra, PhD, Ling Shao, Matjaz Subic, Yevgen Voronenko

Affiliation: RefleXion Medical, Cosylab

Abstract Preview: Purpose: This work enhances the efficiency of radiation therapy treatment planning by optimizing the beamlet dose matrix and full patient dose computations using GPU acceleration. The Collapsed-Cone C...

Impact of Tissue Heterogeneity on Proton LET and RBE Distributions: A Monte Carlo Study

Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu

Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences

Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...

Impact of Tracking By Jaws or Mlc on Treatment Accuracy in Synchrony Modality for Tomohelical Technique

Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon

Affiliation: Clinique De Genolier

Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...

Leveraging Codex-Based Spatial Profiling of the Tumor Microenvironment in Concurrent Radiation Therapy and Immunotherapy

Authors: Todd A Aguilera, Bassel Dawod, Sebastian Diegeler, Eslam Elghonaimy, Purva Gopal, Jiaqi Liu, Hao Peng, Arely Perez Rodriguez, Nina N. Sanford, Robert Timmerman, Megan B Wachsmann, Haozhao Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: This study pioneers the integration of CODEX (co-detection by indexing)-based spatial profiling and advanced computational techniques to investigate the tumor immune microenvironment (TIME) i...

Non-Contact Electroacoustic Imaging Monitoring Electroporation Therapy

Authors: Zhongping Chen, Yuchen Song, Leshan Sun, Liangzhong Xiang, Yifei Xu

Affiliation: University of California, Irvine, University of California Irvine

Abstract Preview: Purpose: Electroacoustic tomography (EAT) monitors the distribution of electrical energy in tissues by detecting acoustics signals induced by electrical pulses during irreversible electroporation (IRE...

Optimal Lattice Design for Spatially Fractionated Radiotherapy (SFRT) of Brain Metastasis in Gamma Knife (GK)

Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom

Affiliation: Elekta, Cleveland Clinic

Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...

Patient-Specific Quality Assurance in SBRT Treatments Using 3D Polymer Gel Dosimetry

Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-Chacón, Alejandro Rodriguez-Laguna

Affiliation: UNAM, Medica Sur

Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≥6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Python Scripts for Film-Based PDD and Profile Analyses of HDR Surface Applicators

Authors: Jack Neylon

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose: Commissioning surface applicators is notoriously laborious. In addition, when commissioning Varian surface applicators with vertically positioned source, we found limited data and resources a...

Spot Scanning Gantry-Based Gaze-Gated Ocular Proton Treatment Planning at Mayo Clinic Rochester

Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse

Affiliation: CancerCare Manitoba, Mayo Clinic

Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...

dosimetric Characterization of Tungsten Eye Shields Using Monte Carlo Simulation

Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag

Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia

Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...