Search Submissions 🔎

Results for "doses 4mgy": 84 found

3D Image Quality Evaluation of a New CT Scanner Employing 3D Landmark Scans, Super Resolution Reconstruction, and Ag Beam Filtration

Authors: Ishika Bhaumik, John M. Boone, Michael T Corwin, Eric S Diaz, Ahmadreza Ghasemiesfe, Andrew M. Hernandez, Sarah E. McKenney, Misagh Piran, Ali Uneri, Eric L White

Affiliation: UC Davis, UC Davis Health, University of California, Johns Hopkins Univ

Abstract Preview: Purpose: A new model CT scanner (Canon Aquilion One Insight) was recently installed at our institution, and it included a 3D Landmark (3DLM) scan for automatic scan planning, a new deep learning recon...

A Dosimeter Independent Method for Measuring Dose from Contrast Enhanced Mammography Exposure.

Authors: Mitya M. Barreto, Nichole A. Harris

Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center

Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...

A Five-Year Retrospective Analysis of Dose Reduction for the Top 10 Adult CT Protocols

Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose:
This study aimed to retrospectively evaluate dose reduction efforts in past five years using acquisition-level data and to compare the results with ACR achievable dose (AD) and dose refere...

A Novel Integrated Framework for Rapid Automatic Calculation of Organ Absorbed Dose from kV-CBCT Imaging during Radiotherapy

Authors: Marios Myronakis, Kyriaki Theodorou

Affiliation: Medical Physics Department, Medical School, University of Thessaly

Abstract Preview: Purpose: The development of an integrated application framework for rapid, seamless, and automated calculation of absorbed organ dose for individual patients undergoing kV CBCT imaging over the course...

A Novel Metric for Predicting Heart Dose Assessment in Left-Sided Breast Cancer Radiotherapy

Authors: Yufeng Cao, Arun Gopal, Kai Huang, Kai Wang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center, University of Maryland, Baltimore

Abstract Preview: Purpose: The treatment of left-sided breast tumors poses significant concerns regarding the risk of radiation-induced damage to nearby organs, particularly the heart. In clinical practice, breath-hold...

A Perturbative Approach to Determine the Charge Collection Efficiency in High Dose-per-Pulse Beams

Authors: Julien Bancheri, Jan P. Seuntjens

Affiliation: Medical Biophysics, University of Toronto, Princess Margaret Cancer Centre & University of Toronto

Abstract Preview: Purpose: To obtain an analytical expression for the charge collection efficiency of parallel-plate ionization chambers in high dose-per-pulse (DPP) beams that takes into account the square pulse time ...

A Practical Experimental Software Validation Method for Voxel-Based Personalised Dosimetry in Radiopharmaceutical Therapy

Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal

Affiliation: University Hospital Southampton

Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...

A Tool to Quantitatively Assess Dose after Patient Motion

Authors: Asma Amjad, Renae Conlin, Beth A. Erickson, William Hall, Eric S. Paulson, Christina M. Sarosiek

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: The adapt-to-shape (ATS) workflow on the MR-Linac involves manual contour edits followed by treatment plan reoptimization on daily pre-beam MRIs. A verification image is acquired after plan o...

Achieving Consistent Calcium Score in Lung Cancer Screening: Influence of Cardiac Phases

Authors: Emi Ai Eastman, Chao Guo, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou

Affiliation: Cedars-Sinai Medical Center

Abstract Preview: Purpose:
Smoking is one of the risk factors for coronary artery disease. It is desirable to estimate the coronary artery calcification (CAC), a key biomarker for atherosclerosis and cardiovascular ...

Adaptive Proton Flash Therapy through Iterative Modular Pin Recycling

Authors: Zachary Diamond, Pretesh Patel, Sibo Tian, Xiaofeng Yang, David Yu, Ahmal Jawad Zafar, Jun Zhou

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose:
We propose a method to optimize adaptive proton FLASH therapy (ADP-FLASH) using modularized pin-ridge filters (pRFs) by recycling module pins from the initial plan, reducing pRF adjustment...

Assessing Weekly Parotid Gland Shrinkage and Predicting Acute Xerostomia Via an Automated Watchdog in Adaptive Radiotherapy Environment of Head and Neck Cancer

Authors: Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Nancy Y Lee, Anyi Li, Jung Hun Oh, Teeradon Treechairusame, Pengpeng Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To automatically monitor weekly anatomical changes of parotid glands during adaptive radiotherapy of head and neck cancers, systematically assess the relationship between parotid gland shrink...

Assessment of Automated Planning Templates for Genitourinary and Gastrointestinal Disease Sites for Online MR-Guided Adaptive Radiotherapy

Authors: Shahed Badiyan, Tsuicheng D. Chiu, Viktor M. Iakovenko, Steve Jiang, Christopher Kabat, Mu-Han Lin, Roberto Pellegrini, Arnold Pompos, Edoardo Salmeri, David Sher, Sruthi Sivabhaskar, Justin D. Visak

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, Global Clinical Science, Elekta AB, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: Adaptive treatment planning requires robust strategies to enable streamlined on-couch processes, creating a significant barrier for planners transitioning from conventional to adaptive planni...

Assessment of Image Quality and Dose in Dual-Energy X-Ray Imaging for Lung Tumor Tracking

Authors: Nawal Alqethami, Felix Ginzinger, Prasannakumar Palaniappan, Marco Riboldi, Philipp Steininger, Wentao Xie

Affiliation: Research & Development, medPhoton GmbH, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t (LMU) MĂŒnchen, Department of Medical Physics, Ludwig-Maximilians-UniversitĂ€t MĂŒnchen (LMU Munich)

Abstract Preview: Purpose:
This study evaluates the image quality of Dual-Energy (DE) X-ray imaging for lung tumor tracking across various sizes and protocols, comparing its imaging dose to Single-Energy (SE) imagin...

Beam Orientation Optimization in IMRT Using Sparse Mixed Integer Programming and Non-Convex IMRT Fluence Map Optimization

Authors: Yabo Fu, Yang Lei, Yu Lei, Haibo Lin, Ruirui Liu, Tian Liu, Kenneth Rosenzweig, Charles B. Simone, Shouyi Wei, Jiahan Zhang

Affiliation: Icahn School of Medicine at Mount Sinai, University of Nebraska Medical Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York Proton Center

Abstract Preview: Purpose: Beam orientation optimization (BOO) in intensity-modulated radiation therapy (IMRT) is traditionally a complex, non-convex problem tackled with heuristic methods. This study benchmarks global...

CBCT Dose Measurement for Common Protocols on Elekta Versahd and Varian Truebeam

Authors: Yingxuan Chen, Jun Li, Alexis N. Webb

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...

Comparison of Ultra-High Resolution and Standard CT Imaging Modes for Small Vessel Visualization in Coronary CTA Using Photon Counting CT

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: This study evaluates the impact of ultra-high resolution (UHR) mode on the visualization of small vessels in coronary computed tomography angiography (CTA) using a photon-counting CT scanner....

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Dedicated Cone-Beam Breast CT: Investigation on the Effect of Lesion Type on Detectability Index Using Cascaded Systems Analysis.

Authors: Jing-Tzyh Alan Chiang, Andrew Karellas, Thomas C Larsen, Hsin Wu Tseng, Srinivasan Vedantham

Affiliation: Department of Biomedical Engineering, The University of Arizona, Department of Medical Imaging, The University of Arizona

Abstract Preview: Purpose: To investigate the performance of dedicated breast computed tomography (BCT) for the the tasks of detection of soft tissue lesions and microcalcifications using cascaded systems analysis. The...

Deformable Scintillator Array Dosimetry for In Vivo Volumetric Dose and Dose-Rate Validation of Uhdr Proton Therapy

Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang

Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison

Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...

Development of the First Benchtop X-Ray Flash System

Authors: Ruirui Dong, Gernot Echner, Peter Haering, Clarence King, Carlos Murillo, Gavin Poludniowski, Nicholas Sammut, Joao Seco, Steffen Seeber, Maria Francesca Spadea, Elpida Theodoridou

Affiliation: KIT, Department of Physics and Astronomy, Heidelberg University, Karolinska Institutet, DKFZ, University of Malta

Abstract Preview: Purpose:
The goal is to develop the first benchtop X-ray FLASH system based on a conventional small animal irradiator. The small animal irradiator will be modeled using a Monte Carlo toolkit for bo...

Differential Hole-Size Lattice Patterns for Escalating SFRT Dose to Large, Deep-Seated, and Unresectable Masses

Authors: Joshua Misa, Damodar Pokhrel, William St. Clair

Affiliation: University of Kentucky, Department of Radiation Medicine

Abstract Preview: Purpose: Development of a novel spatially fractionated radiotherapy (SFRT) lattice deployment method featuring a large high-dose sphere at the tumor’s center, surrounded by smaller diameter spheres. W...

Dose Dependent White Matter Injuries Quantified By Axial and Radial Diffusivity of Diffusion Tensor Imaging Significantly Correlate with Radiation-Induced Neurocognitive Decline in Diffuse Glioma Patients Underwent Chemoradiation Therapy

Authors: Robert Fucetola, Jiayi Huang, Zhihua Liu, Chongliang Luo, Tong Zhu

Affiliation: Washington University School of Medicine, Washington University in St. Louis, School of Medicine

Abstract Preview: Purpose:
This prospective observational study investigates radiation-induced white matter (WM) injuries using longitudinal diffusion tensor imaging (DTI) in patients with diffuse glioma following r...

Dosex As a per-Pulse Uhdr and Conventional Electrometer Compatible with Sandard Clinical Probes

Authors: Petr Bruza, David J. Gladstone, Austin Sloop, Rongxiao Zhang

Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Health

Abstract Preview: Purpose: UHDR-specific probes are becoming available on the market but often demand high costs and long order times. The reduced sensitivity of these probes often imposes challenges when measuring con...

Dosimetric Impact of Auto-Segmentation with Replanning: An Analysis of a Prospective Clinical Trial

Authors: Kathryn J. Dess, Martha M. Matuszak, Dan Polan

Affiliation: University of Michigan

Abstract Preview: Purpose: A recent survey demonstrated 18 of 20 top academic institutions have implemented auto-segmentation. Studies to date have focused on geometric contour changes and dosimetric differences using ...

Dysphagia Optimized Knowledge-Based Planning for Head and Neck Cancer

Authors: James E. Bates, Benjamin Hopkins, Kirk Luca, Shadab Momin, Justin R. Roper, Soumon Rudra, Eduard Schreibmann, Bill Stokes, Tu Thi, Xiaofeng Yang

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Swallowing dysfunctions after radiotherapy are caused by multiple factors yet are strongly associated with the irradiation of pharyngeal musculature due to its role in the initiation and comp...

Enhancing Daily QC for Photon-Counting CT: Incorporating 40 keV VMI Evaluations with the ACR CT Phantom

Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center

Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Evaluating the Radiological Safety of 64Cu-Macrin in PET/MRI Studies through Radiopharmaceutical Dosimetry

Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder

Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School

Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...

Evaluation of Concomitant Imaging Dose in 4D-CBCT Guided Thoracic Radiotherapy

Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao

Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...

Evaluation of Dose-Rate Metrics in Intensity Modulated Proton Therapy for Prostate Cancer Treatments

Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu

Affiliation: Emory Healthcare, Emory University

Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...

Evaluation of Noise and Dose Efficiency in Clinical Photon-Counting CT Colonography with Tin Prefiltration

Authors: Xinhui Duan, Vivek Nair, Liqiang Ren, KyuHo Song, Vasantha Vasan, Kuan Zhang, Yue Zhang

Affiliation: Department of Radiology, UT Southwestern Medical Center

Abstract Preview: Purpose: Minimizing radiation dose is crucial in CT colonography (CTC) screening and diagnosis. Tin (Sn) prefiltration is readily incorporated into clinical photon-counting CT (PCCT) scanners, yet its...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexionℱ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXionÂź X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Feasibility of Rapidarc Dynamic for Lattice Radiation Therapy of Bulky Liver Tumors

Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...

First Demonstration of Prostate Radiotherapy Plan Optimization on an IBM Quantum Computer

Authors: Keisuke Fujii, Masahiro Kitagawa, Arezoo Modiri, Yuichiro Nakano, Ken N. Okada, Robabeh Rahimi, Akira SaiToh, Amit Sawant, Satoyuki Tsukano, Baoshe Zhang

Affiliation: University of Maryland, University of Maryland in Baltimore, Department of Computer and Information Sciences, Sojo University, Center for Quantum Information and Quantum Biology, Osaka University, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland School of Medicine

Abstract Preview: Purpose: Fully personalized radiotherapy requires computational resources far exceeding those of conventional CPU/GPU systems. This study explores the use of quantum computing (QC) in radiotherapy pla...

Hydrated Electron Yield Under Electron Irradiation at Ultra-High Dose Rates with Varying Physical Beam Parameters

Authors: Xu Cao, Wesley S. Culberson, Aubrey Parks, Brian W Pogue, Matthew Reed, William Scott Thomas

Affiliation: University of Wisconsin: Madison, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison, University of Wisconsin - Madison, UW-Madison

Abstract Preview: Purpose: Under Ultra-High Dose Rate (UHDR) irradiation, radical-radical interactions are likely enhanced due higher density production in time and space and this alters the cascade of reactions that s...

Impact of Computed Tomography Noise Reference Levels in a Pediatric Hospital

Authors: Samuel L. Brady, Joseph G. Meier

Affiliation: Cincinnati Childrens Hospital Med Ctr

Abstract Preview: Purpose:
To establish noise reference levels for our pediatric hospital.
Methods:
Water equivalent diameter (Dw) and image noise was automatically measured by using a global noise algorithm i...

Impact of Patient Size on the Choices of Dual and Single Energy CT for Accurate Liver Fat Volume Fraction Quantification

Authors: Xinhua Li, Jie Zhang, Yifang (Jimmy) Zhou

Affiliation: University of Kentucky, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Fat volume fraction (FVF) is an important biomarker for non-alcoholic fatty liver disease. CT can be a good modality for FVF assessment if the accuracy is adequate. We aimed to study the impa...

Impact of Proton Beam Arrangements on LETd and RBE in Organs at Risk for Nasopharyngeal Cancer

Authors: Mauricio Acosta, Zachary Fellows, Alonso N. Gutierrez, Noah S. Kalman, Kristen A. McConnell, Rob Rohe, Andrew J. Wroe, Sreenija A Yarlagadda

Affiliation: Miami Cancer Institute, Baptist Health South Florida

Abstract Preview: Purpose:
Beam selection is crucial in proton therapy to ensure optimal physical and biological dose conformity to the target while maximizing sparing of normal tissue. This work investigates the im...

Improvements from Monte Carlo Simulations over Pencil Beam Algorithms for Normal Tissue Dose Reconstruction in Proton Therapy Patients

Authors: Amy Berrington de Gonzalez, Keith T Griffin, Jae Won Jung, Cari M Kitahara, Choonik Lee, Choonsik Lee, Aimee L McNamara, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: University of Michigan, East Carolina University, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy dose reconstruction enables retrospective epidemiological studies that connect late health effects to the organ-absorbed radiation doses received during treatment. Though clinica...

Initial Comparison of 3D CBCT Performance: New Mobile C-Arm Vs. O-Arm Unit

Authors: Wendy Siman, Wei Zhou

Affiliation: University of Colorado Anschutz Medical Campus, School of Medicine

Abstract Preview: Purpose:
To compare the image quality and radiation dose of 3D cone-beam CT modes of a mobile C-arm and an O-arm unit for intraoperative imaging.
Methods:
A 50-”m tungsten wire was imaged at ...

Innovative Biological Adaptive Radiotherapy (BART) Approach for Head-and-Neck Cancer Treatment Interruptions

Authors: Nobuki Imano, Daisuke Kawahara, Akito S Koganezawa, Yuji Murakami, Ikuno Nishibuchi, Takuya Wada

Affiliation: Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University

Abstract Preview: Purpose: Adaptive radiotherapy (ART) compensates for treatment plans based on anatomical changes while not considering biological effects such as interruptions during treatment. This study aims to dev...

Inter-Patient Adaptive Radiotherapy (IPART): A CT Simulation and Planning Free Approach Enabling Immediate Treatment Access for Patients.

Authors: Bin Cai, Andrew R. Godley, Brian A. Hrycushko, Heejung Kim, Mu-han Lin, David D.M. Parsons, Justin D. Visak, Da Wang, Tingliang Zhuang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center

Abstract Preview: Purpose: The standard radiation therapy workflow requires CT-simulation and planning, whether for initial treatments or re-planning due to significant anatomical changes. IPART instead uses one patien...

Investigating Microcalcification Detectability in a Static Breast Cone Beam CT Via Monte Carlo Simulation

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Gantry motion and patient breathing during a breast cone beam CT (bCBCT) scan is one of the major challenges for microcalcification (ÎŒCalcs) detection. By deploying a large number of individu...

Investigating in-Vivo Megavoltage Radiodynamic Therapy from 6 to 45MV Photon Beam Radiation Therapy with 5-Aminolevulinic Acid

Authors: Lili Chen, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: 5-aminolevulinic acid (5-ALA)-mediated radiodynamic therapy (RDT) has been shown to be an effective treatment option using high-energy photon beams. RDT utilizes tumoricidal capabilities caus...

Investigating the Flash Effect: Uncovering Brain Sparing and Cognitive Preservation across Varying Dose Rates in Whole-Brain Irradiation of in-Vivo Mouse Models

Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu

Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center

Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...

Lesion Detection in Contrast Enhanced Cone Beam Breast CT with a Photon Counting Detector: A Monte Carlo Study

Authors: Ahad Ollah Ezzati, Xiaoyu Hu, Xun Jia, Youfang Lai, Kai Yang, Yuncheng Zhong

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Massachusetts General Hospital, Johns Hopkins University

Abstract Preview: Purpose: Contrast-enhanced breast cone-beam computed tomography (bCBCT) provides high-resolution, 3D imaging of breast tissues with improved differentiation between normal and abnormal tissues. Curren...

Lung Nodule Volume Estimation: Performance of Conventional Energy-Integrating and Cdznte-Photon-Counting CT Using Hybrid Reconstruction Method

Authors: Gisell Ruiz Boiset, Paulo ROBERTO Costa, Luuk J Oostveen, Elsa Bifano Pimenta, Ioannis Sechopoulos, Alessandra Tomal

Affiliation: Radboud University Medical Center, University of SĂŁo Paulo (USP), Institute of Physics, Universidade Estadual de Campinas. Instituto de FĂ­sica Gleb Wataghin

Abstract Preview: Purpose: The study evaluated the accuracy and precision of lung nodule volume measurements, specifically solid nodules (SNs) and ground-glass opacities (GGOs) in different imaging settings.
Methods...

Multi-Institutional Analysis of CT Dose Index Variability and Radiomics Features

Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong

Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati

Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...

Multiparametric and Low-Field MRI for Biomimetic MRI-Readable Gel Dosimeters

Authors: Kaitlyn M Betz, David Dunkerley, Eric Johnson, Kalina V Jordanova, Kathryn E. Keenan, Samuel D Oberdick, Gregory P. Penoncello, Stephen E Russek

Affiliation: Dept of Radiology, Stanford, University of Colorado School of Medicine, NIST, College of Wooster

Abstract Preview: Purpose: Examine use of low-field MRI and multiparametric analysis for 3D MRI-readable biomimetic gel dosimetry. Low-field MRIs are compact, inexpensive, and portable. They could be located within rad...

Non-Planar Narrow-Beam CT: Near Scatter-Free, High-Resolution Breast Imaging at Screening Mammography Doses.

Authors: Peymon Ghazi

Affiliation: MALCOVA Inc.

Abstract Preview: Purpose: To develop a near scatter‐free breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...

Novel 3D Imaging Systems for Surgical Guidance : Loop-X and Nview S1 in Comparison with O-Arm

Authors: Jia Wang, Vani Yadav

Affiliation: Stanford University

Abstract Preview: Purpose: To evaluate the radiation dose and imaging quality of two novel CBCT X-Ray imaging systems used in spine surgeries.
Methods: CBCT scan of ACR CT and CTDI phantoms was performed to acquire ...

On the Sensitivity Evaluation of End-to-End Test in Radiotherapy

Authors: Yussuf A. Abdelal, Sebastien A. Gros, Luke Layman, Anil Sethi

Affiliation: Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago

Abstract Preview: Purpose:
End-to-end (E2E) test is a vital QA check of the overall radiotherapy process from simulation imaging to treatment delivery. Although clinical passing criteria are available, guidelines on...

Optimal Choice of Companion Radiotracer for TAT 225Ac-Mti-201.

Authors: Vinay K Banka, Mikalai Budzevich, William R. Gibbons, Mark L. McLaughlin, Jacob Moriarty, Eduardo G. Moros, David L. Morse, Christopher J. Tichacek, Thad J. Wadas

Affiliation: Modulation Therapeutics Inc, Moffitt Cancer Center, University of Iowa

Abstract Preview: Purpose: A targeted alpha therapy drug, 225Ac-MTI-201, has been developed targeting the Melanocortin 1 Receptor for metastatic uveal melanoma and is currently in FIH clinical trials. Since alpha emiss...

Optimizing Low-Dose Imaging Parameters for Dual-Energy Cone-Beam Computed Tomography in Image-Guided Radiation Therapy

Authors: Sebastien A. Gros, Hyejoo Kang, Andrew Keeler, Luke Layman, Jason Patrick Luce, Ha Nguyen, John C. Roeske

Affiliation: Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago

Abstract Preview: Purpose:
This study aims to optimize virtual monoenergetic (VM) images obtained from dual-energy (DE) cone-beam computer tomography (CBCT) protocols for Image-Guided Radiation Therapy (IGRT). The o...

Performance Evaluation of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System.

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: The purpose of this work is to describe the design and development of a newly developed upright-geometry dedicated breast CT system and to quantitatively and qualitatively evaluate its imagin...

Photon-Counting CT Versus Dual Energy CT for Liver Fat Volume Fraction Assessment

Authors: Chao Guo, Xinhua Li, Michael F. McNitt-Gray, Di Zhang, Yifang (Jimmy) Zhou

Affiliation: UCLA, David Geffen School of Medicine at UCLA, Cedars-Sinai Medical Center

Abstract Preview: Purpose: The objective was to quantify the liver fat volume fraction (FVF) with virtual monochromatic imaging (VMI) using photon-counting CT (PCCT) and dual energy CT (DECT).
Methods: A custom desi...

Preplanning Physics Consultation with Voxelized EQD2: A Proactive Approach for Streamlined Dose Management in High-Risk Re-Irradiation Patients

Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...

Presenting a Novel Treatment Scheme for Debulking Unresectable Large Tumors: Feasibility, Safety and Patient Reported Early Clinical Outcomes of SBRT Immediately Post-Spatially Fractionated Radiotherapy Delivery

Authors: James Knight II, Joshua Misa, Damodar Pokhrel, William St Clair, Eddy S Yang

Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine

Abstract Preview: Purpose: Highly-heterogenous sieve-like dose distribution via SFRT to large/bulky tumors (≄6 cm) could enhance tumor cell-death via both direct/indirect cell-kill mechanisms. Adding highly-conformal S...

Pulse-Based Method of Electrometer Calibration for High Instantaneous Currents Produced in Ultra-High Dose per-Pulse Electron Beams

Authors: Wesley S. Culberson, Miguel Angel Flores Mancera, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: Electrometers are fundamental instruments for absorbed dose determination, and their accuracy is strongly dependent on their calibration. The standard procedure of electrometer calibration is...

Putting the Gram in Esophagram: A New Metric for Harmonizing Fluoroscopy Doses

Authors: Brendon J. Villegas

Affiliation: University of Alabama Birmingham

Abstract Preview: Purpose: The Cumulative Air Kerma (CAK) has traditionally been a surrogate metric for patient exposure to ionizing radiation during clinical esophagrams. Recently, UAB technologists observed that a ne...

Qualitative Assessment of Low-Dose 4D Cone-Beam CT Protocols for Daily Lung SBRT Patient Alignment

Authors: Yussuf A. Abdelal, Junguo Bian, Michael Delafuente, Sebastien A. Gros, Hyejoo Kang, Luke Layman, M Mahesh, John C. Roeske

Affiliation: Department of Radiology and Medical Imaging, Stritch School of Medicine, Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Johns Hopkins Univ

Abstract Preview: Purpose: This study evaluates the feasibility of optimizing 4DCBCT imaging protocols for gated lung SBRT, by reducing dose while maintaining the image quality required for accurate patient alignment.<...

Quantifying Cervical Cancer Radiotherapy Care Gap in Uganda: Baseline Assessment Prior to Implementation of a Custom Mobile Health App.

Authors: Eric C. Ford, Awusi Kavuma, Solomon Kibudde, Lilie Lin, Apollo Muramuzi, Nibedita Paul, Peniel T Twum, Afua A. Yorke

Affiliation: Uganda Cancer Institute, MD Anderson Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Nebraska, Global Communities

Abstract Preview: Purpose: Sub-Saharan Africa accounts for over one-third of global cervical cancer deaths, despite representing only 14% of the world’s female population. At the only RT center in Uganda, prior studies...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Quantitative Accuracy in Iodine Measurements and CT Numbers Using Standard and Ultra-High Resolution Photon-Counting CT in Coronary CTA

Authors: Afrouz Ataei, Victor Moy, Mark P. Supanich

Affiliation: Rush University

Abstract Preview: Purpose: To evaluate iodine quantification and CT number accuracy in coronary CT angiography (CTA) using standard and ultra-high resolution (UHR) modes of photon-counting CT (PCCT) across different do...

Radiation Dosimetry Using Optically Stimulated Luminescence Detection from Luxel with a CCD Camera System

Authors: Mohammad Nazmul Alim, Regina DeWitt

Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University

Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...

Radiomics Changes in MR Images of Prostate and Dominant Intra-Prostate Lesions during SBRT on MR-Linac

Authors: David L. Barbee, David Byun, Ting Chen, Paulina E. Galavis, Siming Lu, Sarah Rosemary Morris, Hesheng Wang, Michael J Zelefsky

Affiliation: NYU Langone Health

Abstract Preview: Purpose: MR-Linac enables dose escalation in prostate SBRT on accurately defined dominant intra-prostate lesion (DIL) on daily MR images. This study aims to evaluate inter-fraction changes in the radi...

Real Time Monte Carlo Dose Calculation for Clinical Cyberknife Radiation Therapy Based on Deep Learning Diffusion Model

Authors: Ruiyan Du, He Huang, Mingzhu Li, Ying Li, Hongyu Lin, Wei Liu, Shihuan Qin, Yiming Ren, Hui Xu, Lian Zhang, Xiao Zhang, Zunhao Zhang

Affiliation: Department of Radiation Oncology, Mayo Clinic, Medical AI Lab, The First Hospital of Hebei Medical University, Hebei Provincial Engineering Research Center for AI-Based Cancer Treatment Decision-Making, The First Hospital of Hebei Medical University, Department of Oncology, The First Hospital of Hebei Medical University

Abstract Preview: Purpose: Monte Carlo (MC) dose calculation is the gold standard in clinical CyberKnife radiation therapy (RT), considering its steep dose gradients and high-freedom non-coplanar beam angles, but extre...

Retrospective MRI-Based Investigation of Bulboclitoris and Vaginal Canal Morphological and Physiological Changes in GYN Patients Treated with External Beam Radiation Therapy

Authors: Diandra Ayala-Peacock, Junzo Chino, Oana I. Craciunescu, Allison Jones, Kyle J. Lafata, Kim Light, Sheridan G. Meltsner, Jack B Stevens

Affiliation: Duke University, Department of Radiation Oncology, Duke University, Duke University Medical Center

Abstract Preview: Purpose: This study aims to develop an MR-based method that retrospectively correlates longitudinal changes in morphology and physiology for the bulboclitoris and vaginal canal with dose received duri...

Scan Efficiency and Imaging Dose Analysis of Next-Generation Nonstop Gated CBCT for Respiratory Gating Lung Radiotherapy

Authors: Sean L. Berry, Weixing Cai, Laura I. Cervino, Yusuf Emre Erdi, Yabo Fu, Yiming Gao, Daphna Gelblum, Wendy B. Harris, Xiuxiu He, Tianfang Li, Xiang Li, Seng Boh Gary Lim, Jean M. Moran, Mitchell Yu, Hao Zhang

Affiliation: Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Gated CBCT (gCBCT) is commonly employed for respiratory gating lung cancer patients to ensure precise patient setup. However, the scan is time-consuming on C-arm linear accelerators (LINAC) d...

Sensitivity of CT Ventilation Imaging to Image Acquisition and Reconstruction Parameters: A Phantom Study

Authors: Hilary Louisa Byrne, Paul J. Keall, John Kipritidis, Jeremy Lim

Affiliation: Northern Sydney Cancer Centre, University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney

Abstract Preview: Purpose:
Non-contrast CT ventilation imaging (CTVI) has been developed as a cost-effective and accessible alternative to PET/SPECT V/Q imaging for visualizing lung function. However, the sensitivit...

Simplified Method of Assessing Lung Volume Limits during the Planning Process in the Re-Treatment Environment

Authors: Sameera Kumar, Chang Ming Charlie Ma, Robert A. Price

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose:
Difficulty assessing lung limits during treatment planning in the retreatment environment can be compounded as limits are volume-based (ie. VxGy<37%) and require a critical volume with a m...

Standardizing Hybrid Angio-CT Procedure Terminology: Mapping to Acr Common Lexicon for Future Drl Establishmen

Authors: Manuel M. Arreola, Hugh Davis, Daniella Fabri, Emily L. Marshall, BC Schwarz

Affiliation: University of Florida

Abstract Preview: Purpose:
This study aims to map procedure names, descriptions, and CPT codes from a Hybrid Angio-CT room to the American College of Radiology (ACR) Common Lexicon. This mapping will support expedit...

TCP Modeling of Regional Recurrencies and Dose to Nodal GTV after Radiotherapy for Head & Neck Cancer

Authors: Brian M. Anderson, Simon A. Brundage, Xuguang Scott Chen, Shiva K. Das, Felice Dong, Spencer Lynch, Panayiotis Mavroidis, Ryan Morse Morse, Heidi Urquidi

Affiliation: University of North Carolina Chapel Hill, University of North Carolina at Chapel Hill, University of North Carolina

Abstract Preview: Purpose: This study aims at correlating different dosimetric indices of nodal GTV with the regional recurrencies observed after head and neck radiotherapy. Also, to perform a tumor control probability...

Targeted Multi-Criteria Optimization for Rapid Improvement of Organ-at-Risk Dose in the Setting of Prostate Stereotactic Body Radiation Therapy

Authors: Alyssa Gadsby, William J. Godwin, Daniel G. McDonald, Jean L. Peng, Alek K. Rapchak, Sean A Roles, Austin M. Skinner, Stephanie Tan

Affiliation: Medical University of South Carolina

Abstract Preview: Purpose: To utilize multi-criteria optimization (MCO) in a targeted fashion to quickly and easily improve dose to the rectum when treating the prostate with stereotactic body radiation therapy (SBRT)....

Technique Factors Optimization and Radiation Dosimetry of an Upright, Short-Scan, Cone-Beam, Dedicated Breast CT System

Authors: Stephen Araujo, Jing-Tzyh Alan Chiang, Cynthia E. Davis, Eri Haneda, Andrew Karellas, Thomas C Larsen, William Ross, Hsin Wu Tseng, Srinivasan Vedantham, Pengwei Wu

Affiliation: Department of Biomedical Engineering, The University of Arizona, GE Aerospace Research, Department of Medical Imaging, The University of Arizona, GE HealthCare Technology & Innovation Center

Abstract Preview: Purpose: To determine the system parameters and technique factors for image acquisition needed so that the mean glandular dose (MGD) of approximately 4.5 mGy is not exceeded for a recently developed, ...

Testing Experience in Dose Monitoring Solutions: Automation Aberrations in Automated Organ Dose Estimation

Authors: Lawrence T. Dauer, Yusuf Emre Erdi, Yiming Gao, Dustin W. Lynch, Usman Mahmood

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Radiation dose to patients in CT examinations (CTDIvol, DLP) is tracked in dose monitoring solutions. Some solutions push for automatically estimating patient organ doses based on exam images...

The Comparison of Radiation Uses in Common Procedures Amongst Didactic Pediatric Fluoroscopic Units

Authors: Janet Ching-Mei Feng, Jimmy Huynh

Affiliation: UTHealth McGovern Medical School

Abstract Preview: Purpose: The Image Gently Alliance had provided helpful information to optimize image protocols in pediatric patients since 2007, and our assumption was that newer units could use near-to-optimal prot...

The Dosimetric and Dose RATE Characteristics for Bragg Peak Proton MINI-Ridge Filter Flash in Comparison to Conventional Proton and Filter Free Flash for Breast and Prostate

Authors: Jenghwa Chang, Chingyun Cheng, J Isabelle Choi, Muhammad Hamza, Minglei Kang, Tyler Kaulfers, Grant Lattery, Haibo Lin, Charles B. Simone, Xingyi Zhao

Affiliation: Peking University, Hofstra University Medical Physics Program, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Physics and Astronomy, Hofstra University, Physics Resident at Montefiore Einstein, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: In terms of high dose rate FLASH, the question remains on how to properly deliver treatment and what clinical sites are feasible to deliver such treatment. The novel Bragg peak (BP-FLASH) and...

The Impact of Intempo Imaging on Cyberknife Prostate Plans

Authors: Lei Fu, Eric Gressen, Yingcui Jia, Shari Rudoler, Yevgeniy Vinogradskiy, Qianyi Xu

Affiliation: Thomas Jefferson University

Abstract Preview: Purpose: InTempo imaging in the Accuray CyberKnife System improves the ability to track/correct target motion during treatment. However, no studies have provided information on the impact of InTempo I...

Towards Arbitrary Phantom Patient Specific IMRT QA on Reflexion X1

Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, RefleXion Medical

Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...

Tumor Response to Catalytic Effect of Carbamide Peroxide to Megavoltage Radiodynamic Therapy with 5-Aminolevulinic Acid

Authors: Lili Chen, Dusica Cvetkovic, Chang Ming Charlie Ma, Dae-Myoung Yang

Affiliation: Fox Chase Cancer Center

Abstract Preview: Purpose: Cytotoxicity caused by the reactive oxygen species (ROS) is a mechanism for treating cancer cells in radiation therapy. 5-aminolevulinic acid (5-ALA)-mediated radiodynamic therapy (RDT), whic...

Uncertainty Analysis for Effective Dose Conversion Factors in CT

Authors: Renxin Chu, Jelena Mihailovic, Kai Yang, Lifeng Yu, Da Zhang

Affiliation: Massachusetts General Hospital, Mayo Clinic, Boston Children's Hospital, UVA Health University Hospital, University of Missouri Health Care

Abstract Preview: Purpose:
A frequently used method to estimate effective dose (ED) in CT is by multiplying the dose length product (DLP) by a conversion factor, known as k-factor. The k-factor in this method is sus...

Using Radiotherapy Dose Accumulation Routine (RADAR) for Deformable Offline Adaptive Head and Neck Dose Accumulation

Authors: Shira Abraham, Eric Aliotta, Michalis Aristophanous, Laura I. Cervino, Yu-Chi Hu, Phillip G. Lichtenwalner, Chuan Zeng, Pengpeng Zhang

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
We have developed a tool that uses deformable image registrations to perform deformable dose accumulation. In this work we evaluate use of this tool for adaptive head and neck dose accumul...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...