Authors: Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier
Affiliation: University of Florida
Abstract Preview: Purpose: To develop a tetrahedralizable mesh-type phantom of a male beagle dog to later perform Monte Carlo radiation transport simulations and calculate organ doses using monoenergetic photons, elect...
Authors: Hao Peng, Yajun Yu
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Personalized ultra-fractionated stereotactic adaptive radiotherapy (PULSAR) is a novel ablative radiation dosing scheme developed by our institution. This study aims to establish a regression...
Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr
Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado
Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...
Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin
Affiliation: Johns Hopkins University
Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...
Authors: Gary Y. Ge, Charles Mike Weaver, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: The recently introduced CMS regulation on CT dose and image quality mandates the use of global noise as the metric for image quality assessment. The regulation cites two methods for calculati...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Angela Jia, Rojano Kashani, Kyle O'Carroll, Alex T. Price, Adithya Reddy, Atefeh Rezaei, Daniel E Spratt, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: To evaluate the effect of unedited AI-generated contours used for online adaptive radiotherapy (FLOW-ART) on the plan quality of prostate treatments as compared to non-adaptive (non-ART) proc...
Authors: Jenghwa Chang, Kuan Huang, Lyu Huang, Jason Lima, Jian Liu, Farzin Motamedi
Affiliation: Northwell, Department of Computer Science and Technology, Kean University, Physics and Astronomy, Hofstra University, Hofstra University Medical Physics Program
Abstract Preview: Title: A Deep Learning Approach to the Prediction of Gamma Passing Rates in VMAT Radiotherapy Plans for Adaptive Treatment.
Purpose: This study aims to develop a deep learning algorithm to predict ...
Authors: Yu Chang, Mei Chen
Affiliation: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Department of Radiation Oncology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine
Abstract Preview: Purpose: Spot weights optimization, as a critical step in the proton therapy, is often time-consuming and labor-intensive. Deep learning, with its powerful learning and computational efficiency, can e...
Authors: Mitya M. Barreto, Nichole A. Harris
Affiliation: Department of Radiology, University Hospitals Cleveland Medical Center
Abstract Preview: Purpose: To evaluate dosimeter dependence of measured AGD, and to develop a dosimeter independent method for evaluating the AGD, for CEDM exposures.
Methods: Three solid-state dosimeters (Raysafe-X...
Authors: Arpit M. Chhabra, J Isabelle Choi, Minglei Kang, Haibo Lin, Hang Qi, Charles B. Simone, Shouyi Wei, Irini Yacoub, Francis Yu, Xingyi Zhao, Ajay Zheng
Affiliation: New York Proton Center, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose:
Pencil beam scanning (PBS) proton therapy effectively treats ocular cancer by minimizing exit doses to normal tissues. However, challenges remain in sparing nearby organs-at-risk(OARs). Ul...
Authors: Shifeng Chen, Mariana Guerrero, Brian A. Hrycushko, Kai Huang, Kai Jiang, Narottam Lamichhane, Paul M. Medin, Elizabeth Nichols
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center
Abstract Preview: Purpose: Unloaded needle catheters, if not handled properly, pose a risk for channel misconnection in interstitial high dose rate (iHDR) brachytherapy. This study aims to investigate the dosimetric im...
Authors: Gabriel Lucas Andrade de Sousa, Einsley-Marie Janowski, Cam Nguyen, Krishni Wijesooriya
Affiliation: Department of Radiation Oncology, University of Virginia, Department of Physics, University of Virginia
Abstract Preview: Purpose: Optimizing radiation therapy (RT) to spare the immune system may improve Overall Survival (OS) in cancer patients. This study develops a computational algorithm to identify optimal dose-volum...
Authors: Haonian Gong, Yue Gu, Meiqi Liu, Zihao Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang, Cheng Zheng
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose:
Proton radiotherapy in preclinical small animals requires specific dose engine due to its low energy and small irradiation volume. This study is to develop a GPU-based Monte Carlo dose eng...
Authors: Jeffrey Bax, Ian A. Cunningham, Aaron Fenster, Lori Gardi, Sule Karagulleoglu Kunduraci, Alla Reznik, David Tessier
Affiliation: Robarts Research Institute, Imaging Research Laboratories, Robarts Research Institute, Lakehead University
Abstract Preview: Purpose: Image-guided biopsy is critical for early diagnosis of prostate cancer (PCa), the most common cancer in men worldwide. While the prostate-specific PET (P-PET) system offers enhanced sensitivi...
Authors: Chloe Doen Kim, Patricia E. Lindsay, Bern Norrlinger, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, Queen's University, Princess Margaret Cancer Centre
Abstract Preview: Purpose: To propose a method to check the consistency of VMAT delivery on linear accelerator (LINAC) with a commercial three-dimensional array device. The method is insensitive to the correction facto...
Authors: Ramesh Boggula, Lincoln Houghton
Affiliation: Karmanos Cancer Institute, Wayne State University
Abstract Preview: Purpose: To evaluate an approach that selectively applies adaptive re-planning only when needed to reduce clinical workload while maintaining treatment quality. Daily adaptive radiotherapy (ART) has t...
Authors: Alejandro Bertolet, Michael D. Farwell, Sarah Gitto, Victor V. Onecha, Daniel Pryma, Aladdin Riad
Affiliation: Department of Pathology and Laboratory Medicine, Abramson Cancer Center, Perelman School of Medicine, University of Pennsylvania, Department of Radiology, Perelman School of Medicine, Perelman School of Medicine at the University of Pennsylvania, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: Responses to ionizing radiation (IR) strongly correlate with the absorbed dose. At the cellular level, this is typically described by a linear-quadratic relationship provided the cell populat...
Authors: Chuxiong Ding, Xuejun Gu, Heejung Kim, Weiguo Lu, Yang Kyun Park, Yulong Yan
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: The purpose of this study was to develop and evaluate a Monte Carlo (MC) dose calculation software (DosemanCK) for secondary dose verification of CyberKnife (CK) treatment plans. Unlike tradi...
Authors: Marios Myronakis, Kyriaki Theodorou
Affiliation: Medical Physics Department, Medical School, University of Thessaly
Abstract Preview: Purpose: The development of an integrated application framework for rapid, seamless, and automated calculation of absorbed organ dose for individual patients undergoing kV CBCT imaging over the course...
Authors: Anthony Hong Cheol Lim, Alexander R ODell, Alexander Stanforth, Chris C. Wang
Affiliation: Georgia Institute of Technology, Emory University
Abstract Preview: Purpose: The purpose of this work is to investigate the variation of proton RBE, with respect to depth, in the context of clinical SOBP. Employing a novel approach, this study conducts a Monte Carlo s...
Authors: Chuan He, Anh H. Le, Iris Z. Wang
Affiliation: Roswell Park Comprehensive Cancer Center, Cedars-Sinai
Abstract Preview: Purpose: To develop a non-measured and DVH-based (NMDB) IMRT QA framework integrating machine learning (ML) to classify lung SBRT VMAT plans prone to delivery errors
Methods: 560 Eclipse AcurosXB l...
Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu
Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...
Authors: Charmainne Cruje, Maria Dumol, Nawroz Fatima, Marisa Finlay, Kalaina Johnson, Raman Mohla, Jasleen Uppal
Affiliation: Trillium Health Partners, Carlo Fidani Regional Cancer Centre
Abstract Preview: Purpose: To evaluate the robustness of a breast SBRT protocol in achieving target coverage by utilizing online- and retrospectively-matched CBCT-to-CT images.
Methods: The first pilot patient was s...
Authors: Thomas Gee, Sofia Michopoulou, Amit Nautiyal
Affiliation: University Hospital Southampton
Abstract Preview: Purpose: Dosimetry software that is accessible to departments offers new opportunities to improve patient-specific dosimetry. Prior to clinical decision-making, it is essential to validate dosimetry s...
Authors: Zhenzhen Dai, Anthony J. Doemer, Ryan Hall, Kenneth Levin, Bing Luo, Benjamin Movsas, Karen C. Snyder, Kundan S Thind, Eleanor Walker
Affiliation: Henry Ford Health, HFHS
Abstract Preview: Purpose: To investigate the feasibility of a predictive tool for efficient allocation of hypofractionated whole-breast irradiation patients between Varian Truebeam and Ethos systems.
Methods: A ful...
Authors: Benjamin W. Maloney, Ashley E. Rubinstein, Colin Schaeffer, Justin Yu
Affiliation: Henry Ford Health
Abstract Preview: Purpose: Radiography AEC systems ensure correctly exposed images for varied kVp and patient thicknesses. The specific kVp and PMMA thicknesses selected for testing AEC tracking may affect passing rate...
Authors: Yanique N. Dunn, Marissa Joyce Vaccarelli
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose: The U.S. Nuclear Regulatory Commission (USNRC) Event Notification Reports provide detailed information on nuclear-related events, including medical and non-medical incidents. This study evalu...
Authors: Larry A. DeWerd, Sean Jollota, Karen Rex Pius Vincent
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Absolute measurements, often used to establish primary standards, offer lower measurement uncertainty. For 192Ir high-dose-rate (HDR) brachytherapy, the interim primary standard for air-kerma...
Authors: Izabella L. Barreto, Benjamin Taylor Heggie, Stephanie M. Leon
Affiliation: University of Florida College of Medicine, University of Florida
Abstract Preview: Purpose: 3D printing has the potential for producing materials useful for the imaging field. This work aims to identify absorption (attenuation coefficient) and material properties (effective atomic n...
Authors: Emi Ai Eastman, Chao Guo, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose:
Smoking is one of the risk factors for coronary artery disease. It is desirable to estimate the coronary artery calcification (CAC), a key biomarker for atherosclerosis and cardiovascular ...
Authors: Shae Gans, Carri K. Glide-Hurst, Mark Pankuch, Chase Ruff, Niek Schreuder, Nicholas R. Summerfield, Yuhao Yan
Affiliation: Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center, Leo Cancer Care
Abstract Preview: Purpose: Novel upright patient positioners coupled with diagnostic-quality vertical CT at treatment isocenter introduce a significant opportunity for improved image-guided particle therapy. Treating p...
Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...
Authors: Wenhua Cao, Hadis Moazami Goudarzi, Madison Emily Grayson, Zongsheng Hu, Gino Lim, Steven Hsesheng Lin, Radhe Mohan
Affiliation: The University of Texas MD Anderson Cancer Center, Department of Industrial Engineering, University of Houston, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Proton Arc Therapy (PAT) offers significant potential in treating complex cancer cases by delivering a continuous radiation dose as the gantry rotates. This study aims to investigate the pote...
Authors: Stephen D. Davis, Alonso N. Gutierrez, Noah S. Kalman, Yongsook C. Lee, Michael Leyva, Alejandro Rene Llanes Lopez, Carlos M. Rivera, Ranjini P. Tolakanahalli
Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute, Miami Cancer Institute, Baptist Health
Abstract Preview: Purpose: Accurate treatment time calculation is a critical component of superficial radiotherapy (SRT), particularly for the SRT-100 Vision, where dose delivery depends on applicator geometry, treatme...
Authors: Carlo Greco, Joep Stroom, Sandra Vieira
Affiliation: Champalimaud Center for the Unknown
Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...
Authors: Lavsen Dahal, Francesco Ria, Ehsan Samei, Justin B. Solomon, Liesbeth Vancoillie, Yakun Zhang
Affiliation: Duke University, Carilion Clinic, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Clinical diagnostic task-based optimization of CT procedures require precise and organ-specific assessments. This study investigates inter-organ noise variability to highlight the limitations...
Authors: Santosh K. Agarwalla, Nrusingh C. Biswal, Shree C, Harikrishnan Suresh Kumar, Jajati K. Nayak, Prema P., Sarath K S, Tamil Selvan S, Hem D. Shukla
Affiliation: Variable Energy Cyclotron Centre, Department of Physics, Fakir Mohan University, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Sciences, Amrita Vishwa Vidyapeetham
Abstract Preview: Purpose: The rapid oxygen depletion in tissues during irradiation is the most accepted mechanism of the FLASH effect. However, the Normal Tissue Complication Probability (NTCP) and Tumor Control Proba...
Authors: Daming LI, Jinsen Xie, Zhe Zhang
Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China
Abstract Preview: Purpose:
This study aims to investigate the feasibility of online dose measurement of the Trilogy linear accelerator output based on target current pulse signals.
Methods:
A data acquisition ...
Authors: Sophie Bockel, Eric Deutsch, Frederic Dhermain, Ibrahima Diallo, Anh Thu Le, Elaine Limkin, Pauline Maury, Charlotte Robert, Killian Sambourg, Camilla Satragno, Cristina Veres, François de Kermenguy
Affiliation: Gustave Roussy, Département de radiothérapie, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique
Abstract Preview: Purpose:
To study the correlation between the dose to circulating lymphocytes as evaluated by the LymphoDose framework and the incidence of severe radiation-induced lymphopenia (sRIL) in patients t...
Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...
Authors: Ivan L. Cordrey, Dharmin D. Desai, Ellis Lee Johnson
Affiliation: Cumberland Medical Center - Cancer Center, University of Kentucky, Varian Advanced Oncology Solutions
Abstract Preview: Purpose: HyperArc (HA) is known to produce a high quality SRS plan. Adding Surface Area Informed Optimization (SAIO) to HA has been shown to improve plan quality metrics R50% and the Conformality Inde...
Authors: Maria F. Chan, Seng Boh Gary Lim, Shih-Chi Lin, Dustin W. Lynch, Usman Mahmood, Jeonghoon Park
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To explore the feasibility of using GafChromic LD-V1 film for annual imaging dose assessment across kV radiography, fluoroscopy, and cone beam computed tomography (CBCT) imaging protocols, as...
Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann
Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania
Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...
Authors: Yan Chu, Madison Emily Grayson, Radhe Mohan, Pablo P. Yepes
Affiliation: UT Health Science Center at Houston, Rice University, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Radiation-induced lymphopenia (RIL) is a common adverse effect of radiation therapy, negatively impacting overall survival and anti-PD1 immunotherapy efficacy. Our lab previously developed a ...
Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny
Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida
Abstract Preview: Purpose:
Pancreatic cancer poses therapeutic challenges due to the proximity of critical organs, requiring precise radiotherapy. Magnetic resonance (MR)-guided linear accelerators provide daily ima...
Authors: Nawal Alqethami, Felix Ginzinger, Prasannakumar Palaniappan, Marco Riboldi, Philipp Steininger, Wentao Xie
Affiliation: Research & Development, medPhoton GmbH, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich)
Abstract Preview: Purpose:
This study evaluates the image quality of Dual-Energy (DE) X-ray imaging for lung tumor tracking across various sizes and protocols, comparing its imaging dose to Single-Energy (SE) imagin...
Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park
Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital
Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...
Authors: Derek Matthew Garcia, Mallory Glenn, Stephen F. Kry, Ruitao Lin, Dennis S. Mackin, Tucker J. Netherton
Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, University of Texas’ MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, Houston
Abstract Preview: Purpose: This study aims to investigate the feasibility of implementing clinically relevant quality metrics for evaluating IROC SRS phantom plans, including conformity index (CI) and homogeneity index...
Authors: Hungcheng Hank Chen, Laura A. Doyle, Helena Frisbie-Firsching, Amy S. Harrison, Jackson D Reeves, Lindsay B Romak, Jon Strasser
Affiliation: Christiana Care
Abstract Preview: Purpose: Brass mesh bolus (BMB) is a high-density woven metal mesh which is an excellent alternative to tissue equivalent bolus in photon beams, offering improved surface conformality. Unlike utilizat...
Authors: Hongyu Jiang, Wangyao Li, Dima Soultan, Fen Wang, Jun Xu
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: To validate the Auto-Beam Hold functionality via the MMI connection between Varian SGRT system IDENTIFY 3.0 and treatment linacs.
Methods: A treatment plan was created in the Eclipse TPS u...
Authors: Ergun E. Ahunbay, Abdul Parchur, Eric S. Paulson, Ilaria Rinaldi, Angelo Schiavi, Li Zhao
Affiliation: Sapienza University of Rome, Department of Radiation Oncology (Maastro), GROW School for Oncology, Maastricht University Medical Centre+, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Online adaptive replanning is often necessary in Intensity Modulated Proton Therapy (IMPT) due to the sensitivity of proton dose distributions to daily anatomical changes. A rapid, automated ...
Authors: Matthew J Ferris, Jason K Molitoris
Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose: Anatomy changes often happen in head-and-neck (HN) patients treated with proton radiation therapy. These changes can result in deteriorations of target dose coverage and increased dose to org...
Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...
Authors: Ramesh Boggula, Nikhil Jordan Shad
Affiliation: Wayne State University
Abstract Preview: Purpose: To evaluate the effectiveness of OpenAI in reviewing large volumes of radiation delivery reports from Mobius3D/FX. The goal was to assess whether automating this process could identify potent...
Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang
Affiliation: University of Kentucky, Department of Radiation Medicine
Abstract Preview: Purpose: Demonstration of automated stereotactic treatment planning for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecard...
Authors: Hannah Grover, Andrew J. Sampson
Affiliation: Oregon Health & Science University, UT Health San Antonio
Abstract Preview: Purpose: The goal of this work was to quantify the dosimetric impact of iodinated contrast on fibroglandular breast tissue to better inform clinical risk and benefit assessments when determining the m...
Authors: Steven Brown, Mike Hopkins, Jerimy C. Polf, Scott Sawyer, Benjamin L. Viglianti
Affiliation: H3D, inc, University of Michigan, M3D, Inc, M3D Imaging
Abstract Preview: Purpose: We characterized the sensitivity, energy dependence, and calibrated dose rate for a radiation imaging survey meter (RAVIN Cam; M3d inc., Ann Arbor MI) based on cadmium zinc telluride (CZT) cr...
Authors: Wilfred R Furtado, Gary Y. Ge, Jie Zhang
Affiliation: Department of Radiology, University of Kentucky, University of Kentucky
Abstract Preview: Purpose: The United Kingdom and several other countries already have well-established diagnostic reference levels (DRLs) for gastrointestinal fluoroscopic procedures, whereas the United States does no...
Authors: Shaheen Dewji, Emmanuel Mate-Kole, Sergio F Ruiz, Chris C. Wang
Affiliation: Georgia Institute of Technology, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology
Abstract Preview: Purpose: Extravasations are clinical events when a substance is administered intravenously and the fluid starts to leak into surrounding tissue instead of the target vessel. In the case of radiopharma...
Authors: Yingxuan Chen, Jun Li, Alexis N. Webb
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose: Cone-beam computed-tomography (CBCT) is widely used for image-guided therapy. Cumulative dose from repeated CBCT might be a concern. This study aims to measure and compare the CBCT dose for c...
Authors: Rodrigo Delgadillo, Nesrin Dogan, Benjamin J. Rich, Stuart E Samuels, Levent Sensoy
Affiliation: University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: Daily Cone beam CT (CBCT) images may be useful in detecting early morphological changes during head and neck cancer radiotherapy. The aim of this study was to evaluate the performance of CBCT...
Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang
Affiliation: UF Health Proton Therapy Institute, University of Florida
Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...
Authors: Ashok Bhandari, Kurtis Johnson, Yu Lei, Tianzhe Li, Kyuhak Oh, Shuo Wang, Chi Zhang, Su-Min Zhou
Affiliation: University of Nebraska Medical Center
Abstract Preview: Purpose: The purpose of this study was to leverage neural network visualization tools to detect high-attention areas indicative of treatment failure in lung SBRT by examining correlation matrices betw...
Authors: Vishruta A. Dumane, Andrew Lukban, Charlotte Elizabeth Read, Mario Serrano-Sosa, Ren-Dih Sheu, Nadia M. Vassell
Affiliation: Icahn School of Medicine at Mount Sinai, Mount Sinai Beth Israel
Abstract Preview: Purpose:
Defined seed positions are used when following the COMS formalism for eye plaques. Au inserts are typically used as templates for placement of radioactive seeds and then covered in Duralay...
Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang
Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize the performance of novel shielded and unshielded silicon diode detectors in relative photon and electron beam dosimetry.
Methods: The novel shielded and unshielded sili...
Authors: Amar K. Basavatia, Lee C. Goddard, Rachel Grimm, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To characterize the “MyOSL Chip” OSLD system for clinical use and compare the response of multiple readers to allow for utilization in a multi-clinic environment.
Methods: Dose calibration...
Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang
Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center
Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the clinical experience with ZapMU for independent second check of dose calculatio...
Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal
Affiliation: Sunnybrook Health Sciences Centre
Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...
Authors: David L. Barbee, Paulina E. Galavis, Lena Adel Samad, Jose R. Teruel Antolin
Affiliation: NYU, NYU Langone Health
Abstract Preview: Purpose: To validate an automated script that converts treatment plans of varying Varian MLC models
Methods: A C# script was developed using the Eclipse Scripting API to convert treatment plans...
Authors: Mark E Artz, Jiyeon Park, Lori Rice, Mohammad Saki, Sanjeev Shukla, Michael Vieceli
Affiliation: University of Florida Health Proton Therapy Institute, Department of Radiation Oncology, University of Florida College of Medicine, UF Health Proton Therapy Institute, Department of Urology, University of Florida College of Medicine
Abstract Preview: Purpose: To investigate how varying levels of DNA repair mutations affect the LET sensitivity of prostate cancer cells.
Methods: The prostate cancer cell lines Du145 (low DNA repair mutations), PC3...
Authors: Xiaoda Cong, Rohan Deraniyagala, Xuanfeng Ding, Xiaoqiang Li, Jian Liang, Peilin Liu, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose:
Commission a step-and-shoot arc therapy(SPArc-step&shoot) for treating head-neck cancer patients as a desired interim milestone toward full dynamic treatment.
Methods:
An in-house de...
Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger
Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie
Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...
Authors: Ahmet S. Ayan, Austin M. Faught, Eunsin Lee, Julia Pakela
Affiliation: Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Ohio State University, The Ohio State University
Abstract Preview: Purpose: To present commissioning of a fixed beamline ultra-high dose rate proton pencil beam scanning system, the world’s first multi-room Varian ProBeam360⁰
Methods: The fixed beamline pencil bea...
Authors: Shupeng Chen, Xiaoda Cong, Raymond Dalfsen, Rohan Deraniyagala, Xuanfeng Ding, James E. Dolan, Xiaoqiang Li, Jian Liang, Peilin Liu, An Qin, Martin Soukup, Craig Stevens, Xiangkun Xu, Weili Zheng
Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Elekta, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital
Abstract Preview: Purpose: To facilitate clinical use of the proton feature of Monaco treatment planning system(TPS), we commissioned and validated it on a compact proton therapy system.
Methods: Pencil Beam Scannin...
Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao
Affiliation: The George Washington University, The George Washington University Cancer Center
Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...
Authors: Gueorgui Gueorguiev, Katia Sergieva, Filip Simeonov, Tsvetelina Todorova, Bozhidar Vladimirov
Affiliation: National Centre of Radiobiology and Radiation Protection, Queen Giovanna University Hospital
Abstract Preview: Purpose: Dosimetry audit is an essential tool enhancing confidence in the accuracy of treatment delivery and in prevention of radiation treatment incidents. Current work depicts how novel nationwide r...
Authors: Serdar Charyyev, Cynthia Fu-Yu Chuang, Veng Jean Heng, Lianli Liu, Lei Xing, Yong Yang
Affiliation: Department of Radiation Oncology, Stanford University
Abstract Preview: Purpose: To replace large finite-size photon phase space files with a compact neural network capable of generating an infinite number of particles.
Methods: Three separate models were developed to ...
Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park
Affiliation: Department of Radiation Oncology, Seoul National University Hospital
Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...
Authors: Wesley A. Belcher, Aidan Burke, Matthew Green, Taylor Stamey
Affiliation: ECU Health, East Carolina University Brody School of Medicine
Abstract Preview: Purpose: The purpose of this study was to determine the effect of using deep inhalation breath hold (DIBH) vs. free breathing (FB) and intensity-modulated radiation therapy (IMRT) vs. 3D for right-sid...
Authors: Tatiana Bejarano, Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Yongsook C. Lee, Michael W. McDermott, Minesh P. Mehta, Robert H. Press, Carlos M. Rivera, Ranjini P. Tolakanahalli, D. Jay J. Wieczorek
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose:
Gamma Knife (GK) cone beam computed tomography-based stereotactic reference (CBCTRef) combined with pre-planning MRI, provides a flexible alternative to the historical frame-based localiza...
Authors: Yunfeng Cui, Will Giles, Xinyi Li, Ke Lu, Jennifer C. O'Daniel, Anna E. Rodrigues, Chunhao Wang, Lana Wang, Yibo Xie, Sua Yoo, Jingtong Zhao
Affiliation: Duke University, Duke University Medical Center
Abstract Preview: Purpose:
To establish quantitative measurement of plan modulation for SRS/SBRT treated with Volumetric Modulated Arc Therapy (VMAT) on C-arm LINACs.
Methods:
A total of 461 plans were analyze...
Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin
Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences
Abstract Preview: Purpose: The purpose of this study was to investigate the interplay effect during intra-fractional motion and the effect of the robust optimization parameters for inter-fractional motion in the intens...
Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago
Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University
Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...
Authors: Brett Bocian, Patrick James Jensen, Luis Augusto Perles, Christopher J. Tien
Affiliation: Yale University School of Medicine, University of Miami, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center
Abstract Preview: Purpose: Guidelines for dose prescriptions in endometrial cancer are based upon depth from the cylinder, traditionally 5 mm or 0 mm (i.e., surface). There are no current single-channel vaginal cylinde...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier
Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...
Authors: Emi Ai Eastman, Christina Lee, Xinhua Li, Alexander W. Scott, Yifang (Jimmy) Zhou
Affiliation: Cedars-Sinai Medical Center
Abstract Preview: Purpose: Iterative reconstruction (IR) methods are valuable for reducing dose in modern CT; however, IR methods have the effect of reducing spatial resolution and hence the lesion edge sharpness. Furt...
Authors: Stephen Balter, Haegin Han, Cari M Kitahara, Taeeun Kwon, Choonsik Lee, Martha S Linet, Donald L. Miller
Affiliation: Columbia University Medical Center, National Cancer Institute, Food and Drug Administration
Abstract Preview: Purpose: Staff in fluoroscopically guided interventional (FGI) procedures are exposed to radiation. Inhomogeneous radiation fields and variability in procedural conditions make it challenging to deriv...
Authors: Lars R Furenlid, Chiao Huang, Matthew A. Kupinski, Brian W. Miller
Affiliation: University of Arizona, Departments of Radiation Oncology and Medical Imaging, University of Arizona
Abstract Preview: Purpose: To sample correlated k-constants in tissue-compartment model for pharmacokinetic study in targeted alpha therapy.
Methods: This work simulated the biodistribution of PSMA-11 tracers labele...
Authors: Angela Gathers, Christina Henson, Sakuntala Jagabattuni, Mark A. Newpower
Affiliation: University of Oklahoma HSC, Department of Otolaryngology, University of Oklahoma HSC, University of Oklahoma Health Sciences Center
Abstract Preview: Purpose: A previous departmental study showed an increase in ototoxicity (hearing loss) rates in head & neck cancer (HNC) patients treated with Intensity Modulated Proton Therapy (IMPT) vs. x-ray radi...
Authors: Nrusingh C. Biswal, Matthew J Ferris, Michael J. MacFarlane, Jason K Molitoris, Byong Yong Yi, Mark J. Zakhary
Affiliation: University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland School of Medicine, University of Maryland
Abstract Preview: Purpose: Proton head-and-neck treatment plans often struggle to maintain plan quality over the course of treatment due to tumor response, weight-loss, and setup variability. Plan robustness to these c...
Authors: Afrouz Ataei, Andrew R. Godley, Mi-Ae Park, Mahbubur Rahman, Liqiang Ren, Chenyang Shen, Gary Xu
Affiliation: Department of Radiology, UT Southwestern Medical Center, UT Southwestern Medical Center, Rush University, Imaging Services, UT Southwestern Medical Center
Abstract Preview: Purpose: Even though many patients undergo diagnostic CT scans prior to treatment, simulation CT scans are commonly required for treatment planning. This study evaluates whether prior diagnostic CT sc...
Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens
Affiliation: Ghent University, Ghent University Hospital
Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...
Authors: Yong Chen, Christina Henson, Yuchen Qiu, Marti Roper
Affiliation: University of Oklahoma HSC, University of Oklahoma Health Sciences Center, University of Oklahoma, University of Oklahoma Health Science Center
Abstract Preview: Purpose: Traditionally, Head and Neck cancer patients have one or two treatment replans through their treatment course, which fails to account for anatomical changes in position, weight loss, or tumor...
Authors: David H. Abramson, Christopher Barker, Jasmine H. Francis, Meng Wei Ho, Yen-Po Lee, Haibo Lin, Hang Qi, Andy Shim, Charles B. Simone, Weihong Sun, Xiaoxuan Xu, Siyu Yang, Francis Yu, Anna Zhai
Affiliation: College of Machine Intelligence, Nankai University, New York Proton Center, Department of Biomedical Engineering, Johns Hopkins University, Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Proton therapy is an effective modality for treating ocular tumors such as uveal melanoma. We developed a novel camera‐based eye‐tracking system to provide real-time noninvasive eye positioni...
Authors: Gary Y. Ge, Abdullah-Al-Zubaer Imran, Kazi Ramisa Rifa, Charles Mike Weaver, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: With renewed attention on CT radiation dose management following CMS approval of new dose measures, establishing image quality–based target doses for every protocol has become essential. Whil...
Authors: Petr Bruza, Megan Clark, David J. Gladstone, Joseph Harms, Anthony E. Mascia, Brian W Pogue, Roman Vasyltsiv, Zhiyan Xiao, Rongxiao Zhang, Yongbin Zhang
Affiliation: Cincinnati Children's Proton Therapy Center, University of Missouri, Dartmouth College, Thayer School of Engineering, Dartmouth College, Washington University in St. Louis, University of Wisconsin - Madison
Abstract Preview: Purpose: With developing FLASH trials requiring diligent delivery monitoring, current proton therapy in-vivo dosimetry (IVD) cannot provide comprehensive verification, including dose and dose-rate vol...
Authors: Yanle Hu, Shuai Leng, Cynthia H. McCollough, Maryam Sadeghian, Joe Swicklik
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To assess the dependency of CT numbers on position in the field-of-view (FOV) using single-energy (SE) and dual-energy (DE) images and energy-integrating detector (EID) and photon-counting de...
Authors: Alexander Baikalov, Luke Connell, Nicholas Coupey, Nolan M. Esplen, Rebecca Lim, Chinh Nguyen, Emil Schueler
Affiliation: Northwell, The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: FLASH radiotherapy delivered using electron linear accelerators (LINAC) requires precise control and minimal variation of dose rate and We developed a robust external beam control system (EBC...
Authors: Matthew Stephen Andriotty, Taoran Cui, Harold Y Hu, Ke Nie, Tan Phan, Xiao Wang, Ning J. Yue, Chengzhu Zhang
Affiliation: Rutgers Cancer Institute of New Jersey, Basis Scottsdale
Abstract Preview: Purpose: Metallic implants are often non-isocentric, and their exact volumes/orientations/shapes are difficult to capture and contour accurately on CT images even if that information is known beforeha...
Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa
Affiliation: National Cancer Centre Singapore
Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...
Authors: Mohamed Bahaaeldin Mohamed Afifi, Nahla Nagy Ahmad Ataalla, Ahmed A. Eldib
Affiliation: Fox Chase Cancer Center, Radiological Sciences and Medical Imaging Department, College of Applied Medical Sciences, Prince Sattam bin Abdulaziz University.
Abstract Preview: Purpose: Optimizing CT imaging parameters is crucial for balancing radiation dose, contrast resolution, and accurate Hounsfield unit representation, particularly in radiotherapy treatment planning. Th...
Authors: Hao Gao, Yuting Lin, Jufri Setianegara, Aoxiang Wang, Peng Xiao, Qingguo Xie, Yanan Zhu
Affiliation: Department of Biomedical Engineering, Huazhong University of Science and Technology, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Intensity-modulated proton therapy (IMPT) achieves uniform tumor dose distribution while sparing organs-at-risk (OAR) by optimizing spot weights across energy layers. Accelerating IMPT delive...
Authors: Wesley E. Bolch, Lotem Buchbinder Shadur, Natalia Estefania Carrasco-Rojas, Chansoo Choi, Robert Joseph Dawson, Shaheen Dewji, John Francis, Emmanual Mate-Kole, Wyatt Smither, Yitian Wang
Affiliation: Georgia Tech, University of Florida, Nuclear and Radiological Engineering and Medical Physics Programs, Georgia Institute of Technology
Abstract Preview: Purpose: Develop a software application capable of assessing the radiation contamination of military service members and members of the general public for fast, on-site radiological triage. The softwa...
Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park
Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital
Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojin Kim, Jin Sung Kim, HO Lee, Sac Lee, Yongdo Yun
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: Carbon ion radiotherapy (CIRT) offers the advantage of a greater relative biological effectiveness (RBE) weighted dose, which must be integrated into the treatment planning system (TPS). This...
Authors: Najah Curtis, Michele M. Kim, Cameron Koch, Ioannis I Verginadis, Rodney D. Wiersma, Jennifer Wei Zou
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, UCLA
Abstract Preview: Purpose: FLASH has been shown to have increased normal tissue sparing compared to standard dose rate radiation and, separately, has been shown to rapidly consume oxygen intercellularly in vivo through...
Authors: Haonian Gong, Yue Gu, Meiqi Liu, Hsiao-Ming Lu, Yuxiang Wang, Yidong Yang
Affiliation: Hefei Ion Medical Center, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China
Abstract Preview: Purpose: To develop a proton CT system using scintillator-based 2D dose distribution detection for accurate proton imaging.
Methods: The proposed proton CT system consists of a brass collimator wit...
Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams
Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...
Authors: Chang Chang, Mohammad Kanber, Stephen Kenneth Northway
Affiliation: East Carolina University, California Protons Cancer Therapy Center, California Proton Cancer Therapy Center
Abstract Preview: Purpose:
Proton therapy treatment planning involves the consideration of unique physical quantities such as Linear Energy Transfer (LET) and spot location maps that do not exist in photon treatment...
Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao
Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...
Authors: Yaowen Cao, Yunwen Huang, Yidong Yang, Xiaogang Yuan, Ning Zhao, Cheng Zheng
Affiliation: Department of Life Sciences and Medicine, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China
Abstract Preview: Purpose: MRI has better soft tissue contrast than cone beam CT which is commonly used in image guided radiotherapy. This study aims to develop a low-field MRI system for precision small animal radiati...
Authors: Michael Buckstein, Yang Lei, Tian Liu, Charlotte Elizabeth Read, Jing Wang, Kaida Yang, Jiahan Zhang
Affiliation: Icahn School of Medicine at Mount Sinai
Abstract Preview: Purpose: Inter-fraction anatomic variations in liver SBRT can cause significant discrepancies between planned and delivered doses. We developed a CBCT-based accumulative algorithm to directly compare ...
Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Lauren E Henke, Rojano Kashani, Haley K Perlow, Alex T. Price, Atefeh Rezaei, Prashant Vempati, Runyon C. Woods
Affiliation: University Hospitals Seidman Cancer Center
Abstract Preview: Purpose: The HyperSight imaging feature on C-arm linacs(HS-CBCT) offers increased CT number accuracy over conventional on-board imaging. The C-arm geometry allows for noncoplanar treatments common to ...
Authors: Ehsan Abadi, Njood Alsaihati, Steven T. Bache, Mridul Bhattarai, Cindy Marie McCabe, Francesco Ria, Ehsan Samei
Affiliation: Duke University, Center for Virtual Imaging Trials, Duke University, Duke University Health System, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: To compare and contrast alternative methods including reader (in hominum), phantom (in phantasma), in vivo, and in silico methods deployed to assess the performance of photon counting (PCCT) ...
Authors: Robert Fucetola, Jiayi Huang, Zhihua Liu, Chongliang Luo, Tong Zhu
Affiliation: Washington University School of Medicine, Washington University in St. Louis, School of Medicine
Abstract Preview: Purpose:
This prospective observational study investigates radiation-induced white matter (WM) injuries using longitudinal diffusion tensor imaging (DTI) in patients with diffuse glioma following r...
Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz
Affiliation: UT Health San Antonio, University of Texas HSC San Antonio
Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...
Authors: Adebayo Abe, Samuel Olaolu Adeneye, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Sylvester Entonu, Muhammad Habeebu, Adedayo O. Joseph, Oluwaseyi Oderinde, Oluwadara Ojediran, Margaret Dideolu Taiwo
Affiliation: University of Ibadan, University of Lagos, Missouri University of Science and Technology, Purdue University, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre
Abstract Preview: Purpose:
Spatially Fractionated Radiation Therapy (SFRT) is an advanced radiotherapy technique designed to deliver highly heterogeneous radiation doses, aiming to optimize tumor control while minim...
Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon
Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center
Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...
Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé
Affiliation: Montefiore Medical Center
Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...
Authors: Davide Brivio, Ivan M. Buzurovic, Thomas C. Harris, Desmond A. O'Farrell
Affiliation: Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Cervical cancer can be treated with a brachytherapy boost following external beam radiotherapy. One applicator option is the Advanced Gynecological Applicator "Venezia" (Elekta) hybrid, consi...
Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang
Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center
Abstract Preview: Purpose: ZAP-X is the newest cranial stereotactic radiosurgery (SRS) platform. Small-volume structures usually found in the head and neck may be susceptible to dose-volume averaging, which has not bee...
Authors: Min Su
Affiliation: Mount Sinai School of Medicine
Abstract Preview: Purpose: To evaluate dosimetric impact of patient setup yaw error to target coverage for pelvis/prostate radiation external beam IMRT-VMAT treatment.
Methods: 9 Pelvis/prostate IMRT-VMAT treatment ...
Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West
Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma
Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...
Authors: J Isabelle Choi, Meng Wei Ho, Isabel Lin, Hang Qi, Qi Zeng, Ajay Zheng
Affiliation: New York Proton Center, Scarsdale High School
Abstract Preview: Purpose: Proton therapy is a promising treatment modality for breast cancer due to its unique dosimetric advantage. Accurate dose calculation is critical to ensure effective treatment outcomes. The fo...
Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang
Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey
Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...
Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic
Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center
Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...
Authors: Alexei V. Chvetsov, Pavitra Ramesh, Alexei V. Trofimov
Affiliation: Massachusetts General Hospital, University of Washington
Abstract Preview: Purpose: To investigate the effect of dose and depth dependence of relative biological effectiveness (RBE) on hypofractionated proton therapy for ocular melanoma using equivalent uniform RBE-weighted ...
Authors: Dennis A. Cheek, Wei Luo, Cameron Thayer-Freeman, Brien Timothy Washington
Affiliation: UT Southwestern Medical Center, University of Kentucky, Department of Radiation Medicine, University of Kentucky
Abstract Preview: Purpose: To investigate the effect of variation in the α/β of cervical cancer on clinical outcome for cervix cancer patients treated with radiation therapy.
Methods: A distribution of experimentall...
Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao
Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine
Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...
Authors: Sean P. Boyer, Shae Gans, Mingcheng Gao, Draik B. Hecksel, Mark Pankuch
Affiliation: Northwestern Medicine Proton Center, Northwestern Medicine Chicago Proton Center
Abstract Preview: Purpose: Protons deposit a large portion of their energy at the end of their range in a region known as the Bragg peak, which may increase the relative biological effective (RBE) dose in this region. ...
Authors: Zakaria Aboulbanine, Greeshma A. Agasthya, Paul Inman, Anuj J. Kapadia, Anthony Hong Cheol Lim, Jayasai Ram Rajagopal, Chris C. Wang
Affiliation: Oak Ridge National Laboratory, Georgia Institute of Technology
Abstract Preview: Purpose: Radiobiological simulation via TOPAS-nBio requires significant computational resources and time to provide meaningful results. This study aims to decrease simulation time and computational re...
Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson
Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta
Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...
Authors: John Ford, Yu Fujiwara, Isao Murata, Zavier Ndum Ndum
Affiliation: Osaka University, Texas A&M University
Abstract Preview: Purpose: This study investigates how particle energy affects radiation quality and biological effectiveness with the inclusion of medical implants. Our research group used microdosimetric analysis to ...
Authors: Michael Butkus, Camilo M. Correa Alfonso, Olga M. Dona Lemus, James Arthur Perez-Sanchez
Affiliation: University of Miami
Abstract Preview: Purpose: Accurate skin dose calculation is essential for treating superficial lesions such as those of the breast, chest wall, and scalp. Clinical treatment planning systems often rely on approximatio...
Authors: Lakshmi Ananthakrishnan, Xinhui Duan, Liqiang Ren, Gary Xu, Kuan Zhang, Yue Zhang
Affiliation: Department of Radiology, UT Southwestern Medical Center, Imaging Services, UT Southwestern Medical Center
Abstract Preview: Purpose: Daily quality control (QC) programs for diagnostic CT include water CT number (HU), standard deviation (SD), and visual artifact evaluations. At our institution, 70 keV virtual monoenergetic ...
Authors: Samira Dabaghmanesh, Beth A. Erickson, William Hall, Jason Hirshberg, An Tai
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Treatment plan evaluation for minimizing duodenal toxicity often involves multiple dose-volume constraints that vary based on fractionation. The Equivalent Uniform Dose (EUD) has emerged as a...
Authors: Emily Helen Hayes, Chihray Liu
Affiliation: University of Florida
Abstract Preview: Purpose: To evaluate dosimetric discrepancies in bladder dose calculations among rigid, deformed, and manual contouring methods in prostate cancer patients and assess dose variations resulting from bl...
Authors: Asma Amjad, Renae Conlin, Eric S. Paulson, Christina M. Sarosiek
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: In an effort to improve contouring accuracy for abdominal MR guided online adaptive radiotherapy (MRgOART), patient-specific deep learning-based auto-segmentation (PS-DLAS) has been proposed....
Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny
Affiliation: Department of Radiation Oncology, University of Rochester
Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...
Authors: Elizabeth M. Alves, Alistair K. Templeton, Julius V. Turian
Affiliation: Rush University Medical Center
Abstract Preview: Purpose: To test the performance of two similar, but not beam-matched, linacs in interchangeably delivering IMRT and VMAT patient-specific quality assurance (PSQA) tests.
Methods: Two TrueBeam lina...
Authors: Alejandro Bertolet, Mislav Bobić, Carlos Huesa-Berral, Aileen O'Shea, Ralph Weissleder
Affiliation: Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: To develop a pipeline for estimating the absorbed dose to various organs from positron emission tomography (PET) combined with magnetic resonance imaging (MRI). We use this pipeline to evalua...
Authors: Mervat A. Alharbi, Wesley S. Culberson
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Medical Physics Department, School of medicine and Public Health, University of Wisconsin-Madison
Abstract Preview: Purpose: The charge collection using ionization chambers is challenging at ultra-high dose rates (UHDR) due to the high ion recombination The Exradin A30 prototype parallel-plate ion chamber manufactu...
Authors: Yuchao Hu, Yajun Jia, Zhangmin Li, Yong Sang, Jianan Wu, Man Zhao
Affiliation: Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, Guangzhou Concord Cancer Hospital, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: To evaluate the imaging dose of 4D-CBCT in patients treated with thoracic radiotherapy.
Methods: A model of the Elekta XVI imaging system was created in TOPAS software. Percentage depth do...
Authors: Stella Flampouri, Edgar Gelover, William Andrew LePain, Roelf L. Slopsema, Alexander Stanforth, Mingyao Zhu
Affiliation: Emory Healthcare, Emory University
Abstract Preview: Purpose: Little consideration was given to the change in dose rate (DR) observed when moving to pencil beam scanning (PBS). This study reports on DR in clinical prostate PBS plans. While dose distribu...
Authors: Nobukazu Fuwa, Masato Horita, Takahiro Kato, Ryo Tanokura, Yuki Tominaga
Affiliation: Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Central Japan International Medical Center, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University
Abstract Preview: Purpose:
We have installed a new type of scanned proton therapy system (Varian ProBeam 360°TM). This study aimed to evaluate the four different dose calculation algorithms.
Methods:
Sixteen b...
Authors: Pat Esposito, Ashley Klein, Carmine Verna, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: To evaluate dosimetric parameters and treatment delivery efficiency between volumetric modulated arc therapy (VMAT) and hybrid dynamic conformal arc (HDCA) on SRS and SBRT planning through st...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.
Methods: Dose calculations in water phan...
Authors: Sabrina Campelo, Sandun Y. Jayarathna, Adam D. Melancon, Paige L. Nitsch, Christopher Ryan Peeler, Julianne M. Pollard-Larkin, Ramaswamy Sadagopan, Xiaochun Wang, George Zhao
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Development of an in-house analytical simulation for streamlining photon counting detector (PCD) system protocols through measuring transmitted photon energy spectra through a Hafnium (Hf)-lo...
Authors: Yunzhi Ma, Ling Zhuang
Affiliation: Northwestern Medicine
Abstract Preview: Purpose: Multiple layers of brass mesh bolus (RPD, Inc., Albertville, MN) may be needed to provide better body conformity and sufficient dose build up on patient surface during electron treatment. Thi...
Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler
Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC
Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...
Authors: Daisuke Kawahara, Yoichi Watanabe
Affiliation: Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Department of Radiation Oncology, University of Minnesota Medical School
Abstract Preview: Purpose: To theoretically demonstrate that FLASH dose delivery leads to higher normal tissue sparing than conventional dose rates.
Methods: A two-component kinetic model was built for target and da...
Authors: Lawrence F. Bronk, Fada Guan, Xun Jia, Youfang Lai, Miao Qi
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins University, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: DNA double-strand breaks (DSBs) are widely regarded as critical indicators of cellular response to ionizing radiation. This study aims to establish a direct, unbiased and universal correlatio...
Authors: Jeff Boob, Jaydev K. Dave, Tim Minch, Bhavyata Tanna
Affiliation: Dr. Ronald E. McNair Academic High School, Mayo Clinic, CurveBeam AI
Abstract Preview: Purpose: To compute effective doses associated with imaging of the extremities with a HiRise (CurveBeam AI, Hatfield, PA) cone-beam CBCT scanner specifically designed for weight-bearing imaging of the...
Authors: Samuel L. Brady, Joseph G. Meier, Elanchezhian Somasundaram, Andrew T Trout
Affiliation: Cincinnati Children's Hospital Medical Ctr, Cincinnati Childrens Hospital Med Ctr
Abstract Preview: Purpose:
To analyze eye-tracker gaze data for insights into radiologists’ areas of focus in an observer study of whole-body PET images.
Methods:
For a comparative study of dose matched PET im...
Authors: Haleem Azmy, Robbie Beckert, Farnoush Forghani, Dean Hobbis, Dan Hong, Hyun Kim, Eric Laugeman, Silpa Raju-Salicki, Domenic Sievert
Affiliation: Washington University in St. Louis School of Medicine, WashU Medicine, Washington University School of Medicine, Department of Radiation Oncology, Washington University School of Medicine in St. Louis, Washington University School of Medicine, Wash U Medicine, Washington University in St. Louis
Abstract Preview: Purpose: A novel radiation therapy (RT) workflow has recently emerged with the advent of online adaptive RT systems, direct-to-unit (DTU). DTU utilizes online adaptive platforms (MR and CT based) to o...
Authors: Bing-Hao Chiang, Eric C. Ford, Juergen Meyer, Timothy D. Solberg
Affiliation: Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington
Abstract Preview: Purpose: This study evaluated the potential risk reduction of various pretreatment patient-specific quality assurance (PSQA) programs for Intensity Modulated Radiation Therapy (IMRT) in mitigating fai...
Authors: Louis Archambault, Nicolas Drouin, Alexis Horik, Simon Thibault
Affiliation: Département de Physique, de Génie Physique et D'optique, et Centre de Recherche sur le Cancer, Université Laval, Département de Physique, de Génie Physique et D'optique, et Centre d'optique, photonique et laser, Université Laval
Abstract Preview: Purpose: To develop a novel type of real-time 3D dosimeter for the quality assurance of linear accelerators used in external beam radiotherapy.
Methods: An experimental setup was constructed using ...
Authors: Grace Hutchinson, Daniel E. Hyer, Samuel D. Rusu, Blake R. Smith, Joel J. St-Aubin
Affiliation: Iowa Health Care, University of Iowa
Abstract Preview: Purpose: To assess the feasibility and consistency of the Sun Nuclear Corporation (SNC) MR conditional Quad Wedge, as an accessory to the IC Profiler-MR, and to evaluate beam output and energy in the ...
Authors: Yiran Liu, Zhengzheng Liu, Fang-Fang Yin
Affiliation: Duke Kunshan Univeristy, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University
Abstract Preview: Purpose: To investigate the feasibility of producing high dose rate GRID therapy using a compact linear accelerator (LINAC) treatment head with scanning beam and stationary grid collimator.
Methods...
Authors: Christine V. Chung, Laurence Edward Court, Meena S. Khan, Ethan B. Ludmir, Rachael M. Martin Paulpeter, Saurabh Shashikumar Nair, Callistus M. Nguyen, Joshua S. Niedzielski, Luis Augusto Perles
Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Spatially Fractionated Radiation Therapy (SFRT) has re-emerged as an efficacious treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) has unique beam delivery capabilities that m...
Authors: Tae Kyu Lee
Affiliation: Allina Health
Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...
Authors: Xiaodong Wu, Xingchen Zhai, Weizhao Zhao
Affiliation: University of Miami
Abstract Preview: Purpose: The ZAP-X is a self-contained, self-shielded radiosurgery system utilizing a 3MV LINAC. Its self-shielded design, poses challenges for conventional beam quality assurance (QA) methods. This s...
Authors: Yoshihiko Hoshino, Kenji Hotta, Taeko Matsuura, Ai Nakaoka, Hidenobu Tachibana
Affiliation: Hokkaido University, Department of Radiology, Gunma University Hospital, Radiation Safety and Quality Assurance Division, National Cancer Center Hospital East
Abstract Preview: Purpose: Gel dosimeters enable three-dimensional dose measurements, but no reports have evaluated the fundamental performance of VIPER-type gel dosimeters in proton beam measurements. Therefore, we ev...
Authors: Mohamad Ahmad Alissa, Carson Brame, Damian Czarnecki, Olivier Evrard, Charbel A. Habib, Jeff Hildreth, Andy Murray, Andreas Schönfeld, Ann-Britt Schönfeld, David Towle, Gerd Wessing
Affiliation: CDT-West - Centrum für Diagnostik und Therapie, Radiologie Vechta, Technische Hochschule Mittelhessen, MyMichigan Health, Sun Nuclear Corp., Mirion Technologies
Abstract Preview: Purpose: To characterize field output correction factors of novel shielded and unshielded silicon diode detectors.
Methods: Novel shielded and unshielded Silicon Diode Detectors (SDD) were characte...
Authors: Girish Bal, David J. Carlson, Huixiao Chen, Zhe (Jay) Chen, Emily A. Draeger, Dae Yup Han, Henry S. Park
Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine
Abstract Preview: Purpose: This study explores the feasibility, accuracy, and dosimetric performance of hybrid biology-guided radiotherapy (BgRT) combined with image-guided radiotherapy (IGRT) for delivering sequential...
Authors: Niels Bassler, Jonathan Bortfeldt, Davide Boscaini, Francesco Evangelista, Guyue Hu, Ze Huang, Margarita Kozak, Julie Lascaud, Giulio Lovatti, Eero Lönnqvist, Jasper Nijkamp, Munetaka Nitta, Prasannakumar Palaniappan, Katia Parodi, Marco Pinto, Per R. Poulsen, Marco Riboldi, Babak Sharifi, Brita Singers Sørensen, Peter Thirolf
Affiliation: Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), Ludwig-Maximilians Universität, Danish Centre for Particle Therapy, Aarhus University Hospital, Department of Medical Physics, Ludwig-Maximilians-Universität (LMU) München, Department of Experimental Clinical Oncology, Aarhus University, Department of Oncology, Aarhus University Hospital
Abstract Preview: Purpose: To perform the first in vivo application of a novel small animal radiation research platform combining on-board image-guidance with multi-field intensity modulated spot scanning delivery [1] ...
Authors: Makunda Aryal, Qiongge Li, Sook Kien Ng, Christopher F. Njeh, Edwin Quashie, Senthamizhchelvan Srinivasan, Yun Wang
Affiliation: Indiana University Medical School, Memorial Health Care System, Indiana University, Inova Hospital, Indiana University School of Medicine, Department of Radiation Oncology
Abstract Preview: Purpose: Linear-Quadratic-Linear (LQL) model is a modification of the traditional Linear-Quadratic model used in radiobiology to describe cell survival in response to radiation. The LQL model extends ...
Authors: Qianyi Xu, Inhwan Yeo
Affiliation: INOVA Schar Cancer Institute, Thomas Jefferson University
Abstract Preview: Purpose:
Four-dimensional computed tomography(4DCT) is prone to a geometrical error when respiration changes upon patient shift. 4DCT with a longer-length detector(16cm), uninvolving the shift, has...
Authors: Himanshu Bhat, Bruce Lewis Daniel, Junghoon Lee, Michael B. Roumeliotis, Ehud J. Schmidt, Ravi Seethamraju, Khadija Sheikh, Pan Su, Akila N. Viswanathan
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Siemens Medical Solutions USA Inc., Stanford Medical School, Department of Cardiology, Johns Hopkins University
Abstract Preview: Purpose: To perform frequent MRI during EBRT and brachytherapy (BT) to evaluate RT-induced fibrosis and remnant tumor changes, identified using ultrashort echo-time (UTE) and multiparametric (mpMRI), ...
Authors: Bingqi Guo, Ping Xia
Affiliation: Cleveland Clinic
Abstract Preview: Purpose:
Spatially fractionated radiation therapy (SFRT) delivers a “GRID” or “lattice” of high and low doses to tumors to increase tumor control, minimize normal tissue damage, and preserve the im...
Authors: Veng Jean Heng, Jan P. Seuntjens, Timothy C. Zhu, Yifeng Zhu
Affiliation: Department of Radiation Oncology, Stanford University, Princess Margaret Cancer Centre & University of Toronto, University of Pennsylvania
Abstract Preview: Purpose: We have developed a GPU-accelerated Monte Carlo (MC) simulation to determine the cumulative dose distribution of patients undergoing Total Skin Electron Therapy (TSET) using the Stanford tech...
Authors: Girish Bal, Jan Kralj, Ayan Mitra, PhD, Ling Shao, Matjaz Subic, Yevgen Voronenko
Affiliation: RefleXion Medical, Cosylab
Abstract Preview: Purpose: This work enhances the efficiency of radiation therapy treatment planning by optimizing the beamlet dose matrix and full patient dose computations using GPU acceleration. The Collapsed-Cone C...
Authors: Jianrong Dai, Jun Dang, Enzhuo Quan, Yong Sang, Jianan Wu
Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center / National Clinical Research Center for Cancer / Cancer Hospital & Shenzhen Hospital / Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
Abstract Preview: Purpose: The current conformity index (CI) formula is distorted for radiotherapy plans with multiple, non-enclosing targets. We redefined the volume of reference isodose (VTV) parameter in the CI form...
Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell
Affiliation: Mount Sinai Beth Israel
Abstract Preview: Purpose: Commissioning of Flexitron HDR horizontal Leipzig applicators typically includes indirect or direct output verification, using a well chamber specific Revised Correspondence Factor (CFrev) or...
Authors: Varsha Jain, Jun Kang, Paul Sulivan, Kate E. Verma, Yevgeniy Vinogradskiy
Affiliation: Thomas Jefferson University
Abstract Preview: Purpose:
Patients undergoing treatment for head and neck(H&N) cancers experience significant body contour changes throughout treatment. Body contour changes are due to tumor shrinkage, weight loss,...
Authors: Rex A. Cardan, Carlos E. Cardenas, John B Fiveash, Joel A. Pogue, Richard A. Popple, Farnaz Rahim Li, Rodney J. Sullivan, Natalie N. Viscariello, Christopher Willey
Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: vBrain radiosurgery toxicity-rate is estimated via clinically-relevant isodose volume (IDV) thresholds according to HyTEC (e.g., V12Gy≤10cc). HyperArcTM (HA) automated planning allows accurat...
Authors: Cheryl Anderson, Lara Best, Amanda Cherpak, Jennifer DeGiobbi, Marc C. LeBlanc, R. Lee MacDonald, Peter R. Martin, Natasha McMaster, Murali Rajaraman, James L. Robar, Lucy Ward, Derek Wilke, Kenny Zhan
Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health
Abstract Preview: Purpose: This work investigates the potential benefit of adaptive planning using the Ethos radiotherapy system (Varian Medical Systems) with direct-dose calculation on HyperSight cone beam CT (CBCT) f...
Authors: Wesley E. Bolch, Chansoo Choi, Chan Hyeong Kim, Suhyeon Kim, Bangho Shin, Yeon Soo Yeom
Affiliation: Hanyang University, University of Florida, 2) Department of Radiation Convergence Engineering, Yonsei University
Abstract Preview: Purpose: Task Group 103 of International Commission on Radiological Protection (ICRP) recently released new-generation adult and pediatric mesh-type reference computational phantoms (MRCPs) via ICRP P...
Authors: Xiangli Cui, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences
Abstract Preview: Purpose:
Respiratory motion introduces substantial dose uncertainties in lung cancer radiotherapy, particularly affecting dose distribution in Simultaneous Integrated Boost-Stereotactic Body Radiot...
Authors: Max Chen, Sean Marquardt, Ben Yang, Kai Yang
Affiliation: Cary Academy, Massachusetts General Hospital, Winchester High School
Abstract Preview: Purpose: To analyze the impact of scanner model variation on the effective dose conversion factor (“k-factor”), which is most commonly used for CT effective dose calculation.
Methods: The stand...
Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny
Affiliation: Department of Radiation Oncology, University of Rochester
Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...
Authors: Sang Hyun Cho, Sandun Y. Jayarathna, Amrit Kaphle
Affiliation: The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: To assess the effectiveness of various nanoscale models of gold nanoparticle (GNP)-laden cells for Monte Carlo (MC) studies of GNP-mediated radiation dose enhancement/DNA damage.
Metho...
Authors: Wesley S. Culberson, Larry A. DeWerd, Ahtesham Ullah Khan, Zachary James Welchel
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, University of Wisconsin-Madison
Abstract Preview: Purpose: Flattening filter free (FFF) linac beams exhibit a centrally peaked beam profile due to the forward-directed bremsstrahlung production from MeV electrons, leading to volume averaging effects ...
Authors: Caroline Esposito, Keith T Griffin, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock
Affiliation: East Carolina University, University of Michigan, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School
Abstract Preview: Purpose: The National Cancer Institute’s Pediatric Proton and Photon Therapy Comparison Cohort aims to collect and analyze data from cancer centers across the United States and Canada to quantify diff...
Authors: Mauricio Acosta, Zachary Fellows, Alonso N. Gutierrez, Noah S. Kalman, Kristen A. McConnell, Rob Rohe, Andrew J. Wroe, Sreenija A Yarlagadda
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose:
Beam selection is crucial in proton therapy to ensure optimal physical and biological dose conformity to the target while maximizing sparing of normal tissue. This work investigates the im...
Authors: Anupama Chundury, Hyejoo Kang, John C. Roeske, Iris A. Rusu
Affiliation: Loyola University Medical Center, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago, Stritch School of Medicine Loyola University Chicago, Cardinal Bernardin Cancer Center, Loyola University Chicago
Abstract Preview: Purpose: To quantify the dosimetric impact of six degrees of freedom (6DoF) intrafractional errors on gross tumor volume (GTV) and planning target volumes (PTV) for single-isocenter multi-target stere...
Authors: Xiangli Cui, Wei Han, Jie Li, Lingling Liu
Affiliation: Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Hefei Cancer Hospital, Chinese Academy of Sciences, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences
Abstract Preview: Purpose: To investigate the influence of tissue heterogeneity on proton beam linear energy transfer (LET) and relative biological effectiveness (RBE) using nine RBE models. This study quantifies the i...
Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Anthony Nagy, Stéphane Nevesny, Nicolas Joel Lionel Perichon
Affiliation: Clinique De Genolier
Abstract Preview: Purpose: Real-time tracking is implemented on Radixact by detecting the target position with 2D-kV image either directly (for lung tumors), or indirectly (using fiducials as surrogates), and by adapti...
Authors: Min-Sig Hwang, Danny K. Lee, Daniel C. Pavord, Kyung Lim Yun
Affiliation: Allegheny Health Network
Abstract Preview: Purpose: Ensuring the quality of treatment plans through patient-specific pre-treatment quality assurance (QA) is essential. However, the use of physical phantom-based QA devices is not feasible for o...
Authors: Takahiro Kato, Teiji Nishio, Masataka Oita, Robabeh Rahimi, Yuki Tominaga, Yushi Wakisaka
Affiliation: University of Maryland, Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Medical Co. Hakuhokai, Osaka Proton Therapy Clinic, Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Faculty of Interdisciplinary Science and Engineering in Health Systems, Okayama University
Abstract Preview: Purpose: This study evaluated dose verifications and lateral penumbra improvements for scanned proton therapy plans with and without a multi-leaf collimator (MLC) under various air gaps.
Methods: E...
Authors: Anthony J. Doemer, Aharon Feldman, Stephen J. Gardner, Brett M. Miller, Benjamin Movsas, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia
Affiliation: Henry Ford Health
Abstract Preview: Purpose: To evaluate the efficacy of calculation-only approach for CIED risk-level assessment.
Methods: A total of 86 patients were included in this retrospective analysis. For each patient, in viv...
Authors: Alexander Alsalihi, Gary Y. Ge, Charles Mike Weaver, Jie Zhang
Affiliation: University of Kentucky
Abstract Preview: Purpose: The upcoming CMS regulation, titled “Excessive Radiation Dose or Inadequate Image Quality for Diagnostic Computed Tomography (CT) in Adults”, employs two measures, size-adjusted DLP (SAD) and...
Authors: Beatriz Allyne Dia Carandang, Chitho P Feliciano, Teresa Sy-Ortin
Affiliation: Department of Physical Sciences and Mathematics, University of the Philippines Manila, Health Physics Research Section, Atomic Research Division, Department of Science and Technology-Philippine Nuclear Research Institute (DOST-PNRI), Graduate School, University of Santo Tomas
Abstract Preview: Purpose: To investigate the X-ray radiation-induced bystander effect (RIBE), where unirradiated cells mimic the responses of directly irradiated cells, in MCF-7 breast cancer cells in vitro to underst...
Authors: Marwa Y. Abdel Tawwab, Amin E Amin, Abdullah M. ElSharif, Somaia Metwally Elsayed, Magdy M. Khalil
Affiliation: School of Applied Health Science, Badr University in Cairo (BUC), Cairo, Egypt, Medical Physics, Radiation Oncology Department, Faculty of Medicine, Ain Shams University, Medical Biophysics, Department of Physics, Faculty of Science, Helwan University
Abstract Preview: Purpose: Prostate cancer radiotherapy typically employs conventional fractionation schedules over approximately eight weeks. This study investigates the effect of variations in the α/β ratio on dose c...
Authors: Nobuki Imano, Daisuke Kawahara, Akito S Koganezawa, Yuji Murakami, Ikuno Nishibuchi, Takuya Wada
Affiliation: Department of Information and Electronic Engineering, Faculty of Science and Engineering, Teikyo University, Department of Radiation Oncology, Graduate School of Biomedical and Health Sciences, Hiroshima University
Abstract Preview: Purpose: Adaptive radiotherapy (ART) compensates for treatment plans based on anatomical changes while not considering biological effects such as interruptions during treatment. This study aims to dev...
Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang
Affiliation: Radiation Oncology, Keck School of Medicine of USC
Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...
Authors: Alexei V. Chvetsov, Sunan Cui, Sunyoung Jang, Robert D. Stewart
Affiliation: University of Washington and Fred Hutchinson Cancer Center, Penn State College of Medicine, University of Washington
Abstract Preview: Purpose: To evaluate spatial variation of relative biological effectiveness (RBE) in COMS (Collaborative Ocular Melanoma Study) eye plaques with low energy 125I and 103Pd photon sources as a function ...
Authors: James Irrer, Charles K. Matrosic, Martha M. Matuszak, Charles S. Mayo, Kelly C. Paradis, Joann I. Prisciandaro, Benjamin S. Rosen, John Yao, Claire Zhang
Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan
Abstract Preview: Purpose: To introduce an in-house developed tool, BioDoseUI, designed to calculate and visualize 3D equieffective dose (EQD2Gy) for treatment planning systems (TPS) without such capabilities, to facil...
Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang
Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...
Authors: Andres Portocarrero Bonifaz, Ian Schreiber
Affiliation: CARTI Cancer Center
Abstract Preview: Purpose: To explore how calculation grid resolution, along with other planning factors, affects head and neck dose calculation accuracy and contributes to potential discrepancies in the Eclipse Treatm...
Authors: Hansong Bai, Peter Jermain, Xun Jia, Heng Li, Devin Miles, Daniel Sforza, Michael H. Shang, Daniel Robert Strauss, Keith Unger, Lingshu Yin
Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, MedStar Georgetown University Hospital, Johns Hopkins University, Department of Radiation Medicine, MedStar Georgetown University Hospital
Abstract Preview: Purpose: To investigate DNA Double Strand Break (DSB) induced by FLASH proton irradiation in a repair-free plasmid DNA model under different free radical scavenging conditions in plateau and Bragg pea...
Authors: Harald Keller, Iymad Mansour, Jeff D. Winter
Affiliation: Princess Margaret Cancer Centre
Abstract Preview: Purpose: The growing number of adaptive therapy applications is motivating image segmentation and direct dose calculation on CBCT. The purpose of this investigation is to evaluate the recently release...
Authors: John T Barrett, Chulhaeng Huh, Farshad Mostafaei, Michelle Rocque, Austin Sanders
Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University, Georgia Radiation Therapy Center, Wellstar-MCG Health
Abstract Preview: Purpose: This study involved the use of Accuray’s TPS (Precision) and RayStation TPS for planning TBI treatments. TBI was delivered using Accuray’s Radixact machine, and dose calculation algorithm, do...
Authors: Omer Gal, Alonso N. Gutierrez, Matthew D. Hall, Rupesh Kotecha, Minesh P. Mehta, Andrew J. Wroe, Jen Yu
Affiliation: Miami Cancer Institute, Baptist Health South Florida
Abstract Preview: Purpose: Linear energy transfer (LET) is directly related to relative-biological-effectiveness dose in proton therapy. This study aims to investigate how the treatment field hinge angles affect LET of...
Authors: Konstantinos Chatzipapas, George C. Kagadis, Panagiotis Konstas, Dimitris N. Mihailidis, Dimitris Visvikis
Affiliation: LaTIM, INSERM UMR1101, University of Pennsylvania, LaTIM, INSERM, University of Brest, University of Patras
Abstract Preview: Purpose: This study investigates the temporal evolution of radiolytic species (H3O+, OH•, OH-) in water under electron and proton irradiation using the mesoscopic chemistry model that allows longer te...
Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell
Affiliation: Northwell, Mount Sinai Beth Israel
Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...
Authors: Hania A. Al-Hallaq, Duncan Henry Bohannon, Chih-Wei Chang, Anees H. Dhabaan, Vishal Dhere, H Scott McGinnis, Pretesh Patel, Sagar Patel, Keyur Shah, Xiaofeng Yang, Jun Zhou
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Two-fraction proton SABR is an attractive alternative to brachytherapy for localized prostate cancer. However, potential interfractional anatomical changes necessitate online adaptation, espe...
Authors: Christopher S. Melhus, Elizabeth Meyer, Cassandra Stambaugh
Affiliation: Tufts Medical Center
Abstract Preview: Purpose: To investigate the clinical treatment planning parameters that impact patient-specific quality assurance (PSQA) passing rates for hippocampal avoidance whole brain (HAWB) treatment plans.
...
Authors: Sina Mossahebi, Pouya Sabouri, Kayla Schneider, James W Snider
Affiliation: University of Maryland School of Medicine, Proton International, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences
Abstract Preview: Purpose:
Conventional patient-specific QA (PSQA) for intensity-modulated proton therapy (IMPT) requires extensive measurements, straining resources in single-room proton centers. This study evaluat...
Authors: Nadège Anizan, Jean-Noël Badel, Thomas Baudier, David Broggio, Désirée Deandreis, Ludovic Ferrer, Didier Franck, Camilo Garcia, Jean Gasteuil, Anne-Laure Giraudet, Olivier Humbert, Laetitia Imbert, Malick Koulibaly, Stéphanie Lamart, Sébastien Leygnac, Alexandre Pignard, Caroline Rousseau, Guido Rovera, David Sarrut, Paul Schwartz, Nicolas Varmenot
Affiliation: Institut de Cancérologie de l’Ouest, Service de Médecine Nucléaire, Gustave Roussy, Service de Physique Médicale, Institut Bergonié, Service de Physique Médicale, CHRU de Nancy Brabois, Service de Médecine Nucléaire, Centre de lutte contre le cancer Léon Bérard, Université de Lyon, Centre Antoine Lacassagne, Service de Médecine Nucléaire, Université Nice Côte d’Azur, Centre Antoine Lacassagne, Service de Médecine Nucléaire, Gustave Roussy, Service de Médecine Nucléaire, Institut de Cancérologie de l’Ouest, Service de Physique Médicale, Service de Médecine Nucléaire, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS/LEDI, Autorité de Sûreté Nucléaire et de Radioprotection (ASNR), PSE-SANTE/SDOS, CREATIS CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA‑Lyon, CREATIS CNRS UMR 5220; INSERM U 1044; Université de Lyon; INSA‑Lyon; Centre de lutte contre le cancer Léon Bérard, Institut Bergonié, Service de Médecine Nucléaire
Abstract Preview: Purpose: The main objective of the Lu-PSMA-Dose study, sponsored by ASNR, is to estimate retrospectively the individual absorbed dose delivered to patients treated with 177Lu-PSMA for metastatic castr...
Authors: Yasaman Anbari, Srinivas Cheenu Kappadath, Benjamin P. Lopez
Affiliation: University of Houston, UT MD Anderson Cancer Center
Abstract Preview: Purpose: To improve lung dosimetry for 90Y-radioembolization planning, CT-based techniques have been proposed for patient-specific lung mass estimation instead of assuming nominal 1 kg lung masses. He...
Authors: Min Cheol Han, Jin Sung Kim, Seok Ho Lee, Gahee Son, Yongdo Yun
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Hanyang University, Department of Integrative Medicine, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine
Abstract Preview: Purpose: This study aims to develop the MC-DOLCE, a Monte Carlo (MC)-based system capable of calculating physical and biological dose distributions, as well as linear energy transfer (LET) distributio...
Authors: Madhava Aryal, James M. Balter, Yue Cao, Daniel T Chang, Kyle Cuneo, Joseph R. Evans, Theodore Lawrence, John Rice, Randall K. Ten Haken, Lise Wei
Affiliation: University of Michigan, Department of Radiation Oncology University of Michigan
Abstract Preview: Purpose: This study aims to identify predictors of global liver function change measured by albumin-bilirubin (ALBI) score following stereotactic body radiation therapy (SBRT) in hepatocellular carcin...
Authors: Alanah M. Bergman, Marc W Deyell, Tania Karan, Jakob Marshall, Justin Poon, Devin Schellenberg, Steven Thomas, Richard Thompson
Affiliation: University of British Columbia, University of Alberta, BC Cancer
Abstract Preview: Purpose: A conservative approach to account for random errors due to intra-fraction cardiac and respiratory motion during cardiac radioablation (CR) is to define a margin equal to the amplitude of car...
Authors: Joseph A. Moore, Paul Rothweiler, Jussi K. Sillanpaa, Adhvaith Sridhar
Affiliation: University of Minnesota
Abstract Preview: Purpose: To investigate 3D printed human tissue simulant phantoms for use in radiation therapy and to quantify the mechanical and radiation properties of these phantoms.
Methods: We designed and 3D...
Authors: Wesley S. Culberson, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Kaustubh A. Patwardhan, Blake R. Smith, Nhan Vu, Karsten K. Wake
Affiliation: University of Wisconsin, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, University of Iowa, Iowa Health Care
Abstract Preview: Purpose:
To perform end-to-end treatment planning and delivery verification of energy-specific collimated treatments optimized to achieve the maximum obtainable high-dose conformity using the dynam...
Authors: Lior Arazi, Gil'ad N. Cohen, Antonio L. Damato, Irene P. Zhang
Affiliation: Unit of Nuclear Engineering, Faculty of Engineering Sciences, Ben-Gurion University of the Negev, NYU Grossman School of Medicine, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Diffusing alpha-emitters Radiation Therapy (“Alpha DaRT”) is a promising new radiation therapy modality for treating bulky tumors. The dose delivered by Alpha-DaRT sources is dependent on the...
Authors: Dirk A Bartkoski, Leonard Che Fru, Benjamin Abraham Insley, Michael Kleckner, Dongyeon Lee, Reza Reiazi, Mohammad Reza Salehpour, Aviad Schori, Ramesh C. Tailor
Affiliation: Empyrean Medical Systems, The University of Texas MD Anderson Cancer Center, Convergent-RnR, The University of Texas, MD Anderson, Houston TX
Abstract Preview: Purpose: A Geant4-based model was created for a G4BraggReflection process to simulate radiation transport within a novel radiotherapy system developed by Convergent Radiotherapy and Radiosurgery (CRnR...
Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens
Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto
Abstract Preview: Purpose: Commissioning of a Gamma Knife® (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...
Authors: Caroline Chung, Michael Knopp, Stephen F. Kry, Hunter S. Mehrens, John Rong
Affiliation: The University of Texas MD Anderson Cancer Center, UT MD Anderson Cancer Center, University of Cincinnati
Abstract Preview: Purpose: To evaluate the variability of CT dose index (CTDIvol) and radiomics features across a large cohort of radiotherapy simulation CT scans from multiple institutions.
Methods: Three IROC phan...
Authors: Sixue Dong, Chaosu Hu, Weigang Hu, Xiaomin Ou, Jiazhou Wang, Zhen Zhang
Affiliation: Fudan University Shanghai Cancer Center
Abstract Preview: Purpose:
This study aimed to predict the PFS of the patients who were diagnosed with hypopharyngeal cancer and received postoperative chemoradiotherapy by using multi-omics which integrating clinic...
Authors: Palanisamy Karunanithi, Karthikeyan Perumal, Siva Subramanian Vadivel
Affiliation: Dr. Kamakshi Memorial Hospital
Abstract Preview: Purpose:
Recent advancements in high dose-rate (HDR) brachytherapy include the image guidance, new applicators, and dose calculation algorithms. Brachytherapy has steep dose gradient, hence relativ...
Authors: Wenchao Cao, Yingxuan Chen, Haisong Liu, Richard A. Popple, Wenyin Shi, Rodney J. Sullivan, Wentao Wang, Lydia J. Wilson, Zhenghao Xiao
Affiliation: Thomas Jefferson University, The University of Alabama at Birmingham, University of Alabama at Birmingham
Abstract Preview: Purpose: Objectively evaluating brain sparing as a plan-quality indicator for patients receiving stereotactic radiosurgery (SRS) to multiple metastases (multi-met) is complicated by variability in tar...
Authors: Vikas Aragam, Edward Castillo, Richard Castillo, Yingxuan Chen, Yevgeniy Vinogradskiy, Lydia J. Wilson
Affiliation: Thomas Jefferson University, Emory University, University of Texas at Austin
Abstract Preview: Purpose: 4DCT-based ventilation imaging (4DCT-ventilation) has been innovatively applied in radiotherapy treatment planning to minimize doses to functional portions of the lung, known as functional av...
Authors: Ali Al Asadi, Amanda Lynn DiCarlo, Anthony J. Doemer, Jessie Y. Huang, Ian Y Lee, Alexandra Moceri, Adam Robin, Lisa Scarpace, Mira Shah, Salim Siddiqui, Kundan S Thind
Affiliation: Henry Ford Innovations, Henry Ford Health
Abstract Preview: Purpose: For a patient who had two previous courses of external beam therapy for rectosigmoid adenocarcinoma and presented with painful, recurrent disease in the sacrum, this study describes the first...
Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Nadia M. Vassell
Affiliation: Mount Sinai Beth Israel
Abstract Preview: Purpose: Ocular HDR brachytherapy is used as an alternative treatment for eye cancer, especially with extrascleral extension in the orbit. This complex procedure inserts catheters into the orbit affix...
Authors: Larry A. DeWerd, Ahtesham Ullah Khan
Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison
Abstract Preview: Purpose: Total body irradiation (TBI) technique uses high energy photon beams with extended source-to-surface distances (SSDs) to irradiate the entire patient to prepare them for bone marrow or stem c...
Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom
Affiliation: Elekta, Cleveland Clinic
Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...
Authors: Zayne Belal, Rachel Drummey, Clifton David Fuller, Stephen Y. Lai, Brigid A. McDonald, Setareh Sharafi, Sonja Stieb, Kareem Abdul Wahid
Affiliation: Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology, Hospital of the University of Pennsylvania, Department of Radiology, Johns Hopkins University, KSA-KSB, Cantonal Hospital Aarau, College Of Osteopathic Medicine, NOVA Southeastern University, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose:
Radiotherapy-induced dysphagia can significantly impair head and neck (H&N) cancer patients’ quality of life. Despite the dose-dependent relationship between radiotherapy and dysphagia, sw...
Authors: Kimyli Lemieux, Xingyu Nie
Affiliation: University of Kentucky/UK HealthCare
Abstract Preview: Purpose: To optimize the selection of calibration radioisotope and its activity for dose calibrator (DC) linearity testing, adhering to ALARA (As Low As Reasonably Achievable) principles while conside...
Authors: Mark W. Geurts, Bridget Ann Melke
Affiliation: Aspirus Health
Abstract Preview: Purpose:
To develop a tool that streamlines and standardizes the process of positioning the SRS MapCHECK detector for intersecting multiple metastases during SRS QA of Single-Isocenter, Multiple Ta...
Authors: Akire Trestrail
Affiliation: University of Wisconsin
Abstract Preview: Purpose: To investigate the feasibility of using 125I as a HDR directional brachytherapy source.
Methods: Monte Carlo (MC) simulations were performed using the EGSnrc software toolkit. Dose rate di...
Authors: Panagiotis Iliopoulos, Marios Myronakis, Kyriaki Theodorou
Affiliation: Medical Physics Department, Medical School, University of Thessaly
Abstract Preview: Purpose: To estimate individualized absorbed dose at Organs at Risk (OARs) from kV Cone Beam CT (CBCT) imaging in the pelvic area, prior radiotherapy, and assess excess risk for secondary malignancies...
Authors: James M. Balter, Lando S. Bosma, Jorge Tapias Gomez, Nishant Nadkarni, Mert R Sanbuncu, William Paul Segars, Ergys D. Subashi, Neelam Tyagi, Harini Veeraraghavan
Affiliation: University of Michigan, The University of Texas MD Anderson Cancer Center, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Carl E. Ravin Advanced Imaging Laboratories and Center for Virtual Imaging Trials, Duke University Medical Center, Cornell University, University Medical Center Utrecht, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: Develop patient-specific virtual digital twin (VDT) cohorts modeling physically realistic spatio-temporal gastrointestinal (GI) organs (stomach and duodenum) digestive motion.
Methods: Pat...
Authors: Esteban Arzaga-Barajas, Paola Jazmin Guadarrama Huerta, Jose Alejandro Jimenez, Guerda Massillon-JL, Maria Adela Poitevin-Chacón, Alejandro Rodriguez-Laguna
Affiliation: UNAM, Medica Sur
Abstract Preview: Purpose: To perform patient-specific quality assurance (PSQA) tests for four SBRT treatments of patients diagnosed with vertebral, ilium, pelvic lymph node and lung tumors.
Methods: MAGIC gel consi...
Authors: Wouter Crijns, Frederik Maes, Loes Vandenbroucke, Liesbeth Vandewinckele
Affiliation: Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven; Department of Radiation Oncology, UZ Leuven, Department ESAT/PSI, KU Leuven; Medical Imaging Research Center, UZ Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, KU Leuven
Abstract Preview: Purpose: To explore intentional deep overfit learning (IDOL) to exploit the initial treatment plan to predict an adaptive radiotherapy plan.
Methods: A conditional generative adversarial network is...
Authors: Belen Juste, Choonsik Lee, Matthew Mille, Rafael Miró, Sergio Morato Rafet, Agustin Santos, Gumersindo Verdú
Affiliation: Division of Cancer Epidemiology and Genetics, National Cancer Institute, Universitat Politècnica de València, Servicio de Radiofísica y Protección Radiológica, Consorcio Hospitalario Provincial de Castellón, National Cancer Institute
Abstract Preview: Purpose: To evaluate the differences in CT scan radiation dose estimation between personalized dose reconstruction, based on real patient CT images, and generalized phantom-based dose calculations.
Authors: Soren Bentzen, Arezoo Modiri, Zaker Rana, Amit Sawant, Lena Specht, Ivan Vogelius
Affiliation: University of Maryland, University of Maryland in Baltimore, Dept. Of Oncology Copenhagen University Hospital – Rigshospitalet, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland School of Medicine
Abstract Preview: Purpose: There is wide inter-physician radiotherapy planning variability for lymphomas and no systematic way to individualize a plan with respect to patient-specific outcome risks. In response to this...
Authors: Ricardo Garcia Santiago, Narges Miri, Daryl P. Nazareth, Ankit Pant, Mukund Seshadri
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To develop a transformer-based deep learning network framework for predicting VMAT dose distributions. This can provide fast and efficient calculations with accuracies potentially comparable ...
Authors: Laura Buchanan, Samantha G. Hedrick, Stephen L. Mahan, Isabella Pfeiffer, Chester R. Ramsey, Taylor Ransom
Affiliation: Thompson Proton Center, University of Tennessee
Abstract Preview: Purpose: Proton pencil beam scanning can reduce normal tissue dose but is highly sensitive to setup, anatomical changes, and range variations. These uncertainties may compromise target coverage and or...
Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke
Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health
Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...
Authors: Payman Hejazi, Faraz Kalantari, Milad Peer-Firozjaei, Romina Pourhashem, Ehsan Tajikmansoury
Affiliation: Department of Radiobiology and Medical Physics, Babol University of Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Medical Physics, Semnan University of Medical Sciences, Department of Medical Physics, Semnan University of Medical Sciences, Semnan, Iran, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine
Abstract Preview: Purpose:
Pretreatment biodistribution imaging play a crucial role in optimizing tumors and organ absorbed doses estimation in radionuclide therapy. Surrogating radionuclides for more efficient trea...
Authors: Qianxi Ni, Qionghui Zhou
Affiliation: The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital, the Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University
Abstract Preview: Purpose:
This study aims to develop and evaluate interpretable machine learning models that use radiomic and dosimetric features to predict HT in advanced cervical cancer patients.
Methods:
R...
Authors: Jeremy T. Booth, Martin Andrew Ebert, Robert Finnegan, Annette Haworth, George Hruby, Burhan Javed, Kazi Ridita Mahtaba, Leyla Moghaddasi, Yutong Zhao
Affiliation: Northern Sydney Cancer Centre, Royal North Shore Hospital, The University of Sydney, The University of Western Australia, Genesis Care, Rockhampton Hospital
Abstract Preview: Purpose:
To evaluate the efficacy of an atlas-based tumor control probability (TCP) model in predicting prostate cancer (PCa) recurrence by retrospectively integrating patient-specific primary radi...
Authors: Njood Alsaihati, Francesco Ria, Ehsan Samei, Justin B. Solomon, Martina Talarico, Jered Wells
Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose: Radiation dose and associated risk in X-ray imaging is principally informed by patient size, further used in Computed Tomography (CT) to achieve prescribed image quality levels through tube c...
Authors: Ali Hosni, Oleksii Semeniuk, Andrea Shessel, Teo Stanescu
Affiliation: Princess Margaret Hospital, Princess Margaret Cancer Centre, Brown University Health
Abstract Preview: Purpose: To report on early clinical experience with a two-phase radiotherapy approach for esophageal cancer patients, utilizing CBCT-based conventional C-arm linear accelerator radiotherapy and MR-gu...
Authors: Katja M. Langen, Mark McDonald, Bill Stokes, Yinan Wang, Suk Whan (Paul) Yoon
Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University
Abstract Preview: Purpose: Effective dose management in high-risk re-irradiation (ReRT) patients entails early, detailed special physics consultation (SPC) to mitigate risks from cumulative radiation dose. SPCs have tr...
Authors: Timothy J Allen, Clara Ferreira
Affiliation: University of Minnesota, Department of Radiation Oncology, University of Minnesota, Minneapolis
Abstract Preview: Purpose: Presurgical treatment planning for GammaTile cranial implants is limited to estimates of required tiles and provides no positioning information. Existing tools are intended for tile estimatio...
Authors: Maria Jose Medrano, Grant Stevens, Liyan Sun, Justin Ruey Tse, Adam S. Wang, Sen Wang
Affiliation: Department of Radiology, Stanford University, GE HealthCare, Stanford University
Abstract Preview: Purpose: Patient exposure to ionizing radiation is a major concern in CT imaging. Size-specific dose estimation methods can prospectively estimate organ-level radiation doses based on patient sizes an...
Authors: Mireille Conrad, Cédric De Marco, Marie Fargier-Voiron, Maud Jaccard, Oscar Matzinger, Nicolas Joel Lionel Perichon
Affiliation: Clinique De Genolier
Abstract Preview: Purpose: The Accuray Synchrony real-time motion fiducial tracking solution allows for prostate stereotactic treatment on both Cyberknife and Radixact machines. In our radiotherapy department, two solu...
Authors: Ahmad K. Al-Basheer, Andrew Clarke Grice, Kelly E. Hosier, Mark Logsdon, Evan A. Silverstein, Chris Tunnicliff, Chuan Wu
Affiliation: Sutter Medical Foundation, Sutter Health
Abstract Preview: Purpose: For Prostate SBRT Boost treatments, determine whether a uniform 2mm CTV to PTV margin is sufficient to give 95% dose coverage to the CTV in 90% of patients via a modified Van Herk Margin Form...
Authors: Stephen M Corner, Daiki Hara, Jiasen Ma, Robert W Mutter, Mark D. Pepin, Nicholas B. Remmes, Hok Seum Wan Chan Tseung
Affiliation: Mayo Clinic - Rochester
Abstract Preview: Purpose: Proton minibeam radiotherapy (pMBRT) is a form of spatially fractionated radiation therapy leveraging submillimeter beams to improve the therapeutic ratio. We report on collimator design, com...
Authors: Fre'Etta Brooks, Catharine H Clark, Patricia Diez, Peter B. Greer, Hideaki Hirashima, Rebecca M. Howell, Mohammad Hussein, Stephen F. Kry, Joerg Lehmann, Jessica Lye, Mitsuhiro Nakamura, Christopher L. Nelson, Rushil Patel, Christine Peterson, Julianne M. Pollard-Larkin
Affiliation: Kyoto University, The University of Texas MD Anderson Cancer Center, Radiotherapy Trials Quality Assurance Group, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Medical Physics & Biomedical Engineering, University College London, Metrology for Medical Physics, National Physical Laboratory, Austin Health, University of Washington Medical Center, University of Newcastle
Abstract Preview: Purpose: To assess the consistency of end-to-end dosimetry audits currently used by different international clinical trial QA organizations with the goal of harmonizing audits and reducing audit overl...
Authors: Haiqa Arain, Ping Xia, Zhexuan Zhang
Affiliation: Cleveland Clinic
Abstract Preview: Purpose: To quantify water contents and thickness of wet towel (as a flexible bolus) on curved surface dose for partial breast irradiation.
Methods: Two VMAT partial breast plans (3000 cGy in 5...
Authors: Eric C. Ford, Awusi Kavuma, Solomon Kibudde, Lilie Lin, Apollo Muramuzi, Nibedita Paul, Peniel T Twum, Afua A. Yorke
Affiliation: Uganda Cancer Institute, MD Anderson Cancer Center, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, University of Nebraska, Global Communities
Abstract Preview: Purpose: Sub-Saharan Africa accounts for over one-third of global cervical cancer deaths, despite representing only 14% of the world’s female population. At the only RT center in Uganda, prior studies...
Authors: Em Harkness, Francesco Ria, Ehsan Samei
Affiliation: Duke University, Clinical Imaging Physics Group, Department of Radiology, Duke University Health System
Abstract Preview: Purpose:
A recently introduced mathematical method quantifies performance-based clinical risk to create a risk-to-risk assessment with radiation risk, rendering the so-called total risk. However, t...
Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson
Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer
Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...
Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang
Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center
Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...
Authors: Lars Ewell, Russell J. Hamilton
Affiliation: Banner University Medical Group, Bannerhealth
Abstract Preview: Purpose: To estimate the variability and predictability of radiation dose as a function of the planning target volume (PTV) size and the anatomical sites of head & neck, brain and prostate.
Methods...
Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis
Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina
Abstract Preview: Purpose:
To calculate radiobiological metrics of daily dose delivered for head and neck (HN) patients using the daily cone beam CT (CBCT) to generate a pseudo CT (pCT). Moreover, this work compares...
Authors: David L. Barbee, David Byun, Ting Chen, Paulina E. Galavis, Siming Lu, Sarah Rosemary Morris, Hesheng Wang, Michael J Zelefsky
Affiliation: NYU Langone Health
Abstract Preview: Purpose: MR-Linac enables dose escalation in prostate SBRT on accurately defined dominant intra-prostate lesion (DIL) on daily MR images. This study aims to evaluate inter-fraction changes in the radi...
Authors: Tianliang Gu
Affiliation: UT Health Science Center at Houston
Abstract Preview: Purpose:
In Nuclear Regulatory Commission guide 8.39 on releasing patients administered radioactive material, the dose is calculated assuming both the source and receiver are points. This point mod...
Authors: Steve B. Jiang, Dan Nguyen, Chenyang Shen, Fan-Chi F. Su, Jiacheng Xie, Shunyu Yan, Daniel Yang, Ying Zhang, You Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, The University of Texas at Dallas
Abstract Preview: Purpose: Fast dose verification is essential for the safety and efficiency of MR-guided adaptive radiotherapy (ART) as patients anxiously waiting on the treatment couch. Conventional tools often requi...
Authors: Petr Bruza, David J. Gladstone, Lesley A Jarvis, Austin Sloop, Kevin J. Willy, Rongxiao Zhang
Affiliation: Thayer School of Engineering, Dartmouth College, Dartmouth Cancer Center, Dartmouth Health
Abstract Preview: Purpose:
Active beam monitoring and output-gated dosimetry are essential systems for safe and accurate radiation delivery. UHDR irradiators such as the Mobetron rely on pre-programmed regimes and t...
Authors: Daming LI, Jinsen Xie, Zhe Zhang
Affiliation: Peking University Shenzhen Hospital Radiotherapy Department, School of Nuclear Science and Technology, University of South China
Abstract Preview: Purpose: To analyze the actual doses received during radiotherapy for head and neck cancers (HNC) using Velocity, providing insights for adaptive radiotherapy decision-making.
Methods: Thirty-three...
Authors: Danielle Renee Daiger, Nicholas N. Sperling
Affiliation: University of Toledo, University of Toledo Medical Center
Abstract Preview: Purpose:
To retrospectively evaluate the impact of planned delivery time on plan quality metrics for breath-hold VMAT SBRT thoracic cancer patients.
Methods:
Patients treated for SBRT thoraci...
Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang
Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill
Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...
Authors: Garrett Russell Hamilton, Joshua Misa, Damodar Pokhrel, William St. Clair
Affiliation: University of Kentucky, Department of Radiation Medicine, University of Kentucky, Radiation Medicine
Abstract Preview: Purpose: Recurrent brain metastasis is very common, and patients who previously received whole-brain radiotherapy (WBRT) may receive an additional course(s) of stereotactic radiosurgery (SRS) to selec...
Authors: Joke Binst, Hilde TC Bosmans, Niki Fitousi, Bram Miseur, Dimitar Petrov, Kwinten Torfs, Janne Vignero
Affiliation: Qaelum NV, Department of radiology, UZLeuven, Department of imaging and pathology, KULeuven
Abstract Preview: Purpose: Routine quality monitoring in CT abdomen is crucial for ensuring optimal image quality and patient safety, but the simultaneous evaluation of all aspects of importance is challenging. The pur...
Authors: Jae Won Jung, Daniel Lee
Affiliation: Thomas S. Wootton High School, East Carolina University Brody School of Medicine
Abstract Preview: Purpose: Monkeys have played a key role in enhancing our understanding of the behavior of radioactive materials within living organisms in the field of nuclear medicine. However, detailed dosimetric d...
Authors: Angela Gearhardt, Stephen F. Kry, Christopher Ryan Peeler, Julianne M. Pollard-Larkin
Affiliation: The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences; The University of Texas MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: A growing number of radiation therapy (RT) patients have cardiovascular implantable electronic devices (CIEDs). Patients with CIEDs must be carefully managed because the devices are susceptib...
Authors: Amanda J. Deisher, Susannah V. Hickling, Shima Ito, Jon J. Kruse
Affiliation: CancerCare Manitoba, Mayo Clinic
Abstract Preview: Purpose:
To date, 11 ocular patients were treated with spot scanning gantry-based gaze-gated ocular proton program at Mayo Clinic, Rochester MN since 2023. Treatments are done in the half-arc gantr...
Authors: Bryan Bednarz, Laura Bennett, Abby E. Besemer, Tyler J Bradshaw, Steve Y Cho, John M. Floberg, Joseph Grudzinski, Elissa Khoudary, Michael J. Lawless
Affiliation: Department of Radiology, University of Wisconsin, University of Wisconsin-Madison Department of Medical Physics, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Voximetry, Inc, University of Pennsylvania, Department of Radiology, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: To assess the impact of using a standardized immobilization setup for multi-time-point SPECT/CT imaging on radiopharmaceutical therapy (RPT) dosimetry image registration.
Methods: Ten ...
Authors: Lori Buchholtz, Alison Garda, Chris L. Hallemeier, Kathryn L. Kolsky, Han Liu, Joseph John Lucido, Marisa Schinter, Andrew J. Veres, Sara Walerak
Affiliation: Mayo Clinic
Abstract Preview: Purpose: The C_START initiative aims to streamline and simplify the Direct-to-Unit (DtU) clinical setup and treatment planning process for photon radiation therapy, particularly for emergent cases suc...
Authors: David L. Barbee, Jose R. Teruel Antolin, Jinyu Xue
Affiliation: NYU Langone Health
Abstract Preview: Purpose: This work introduces a method of regional dose evaluation of normal brain tissue using local target-specific evaluation and compares to global dose evaluation for linac-based single-isocenter...
Authors: Anthony R Bardwell, Dong Won Kim, Faith S Kim, Isaac Y Kim, Juying Zhang
Affiliation: Kaiser Permanente
Abstract Preview: Purpose: When a patient develops a significant skin reaction at some point during postmastectomy radiotherapy, a clinical decision is often made to discontinue the planned daily use of bolus. The aim ...
Authors: Jenghwa Chang, Chingyun Cheng, J Isabelle Choi, Muhammad Hamza, Minglei Kang, Tyler Kaulfers, Grant Lattery, Haibo Lin, Charles B. Simone, Xingyi Zhao
Affiliation: Peking University, Hofstra University Medical Physics Program, New York Proton Center, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Physics and Astronomy, Hofstra University, Physics Resident at Montefiore Einstein, Department of Human Oncology, University of Wisconsin-Madison
Abstract Preview: Purpose: In terms of high dose rate FLASH, the question remains on how to properly deliver treatment and what clinical sites are feasible to deliver such treatment. The novel Bragg peak (BP-FLASH) and...
Authors: Kevin Albuquerque, Ti Bai, Yesenia Gonzalez, Brian A. Hrycushko, Zohaib Iqbal, Paul M. Medin, Shanshan Tang
Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center
Abstract Preview: Purpose: Cervical cancer remains one of the most common and significant gynecological (GYN) malignancies globally, often presenting at advanced stages where radiation therapy and high-dose-rate (HDR) ...
Authors: Ana Maria Barragan Montero, John A. Lee, Eliot Peeters, Romain Schyns, Edmond S. Sterpin, Sophie Wuyckens
Affiliation: UCLouvain, Universite Catholique de Louvain
Abstract Preview: Purpose:
Although the likelihood of a point being tumorous decreases with distance from the GTV, CTVs are still defined as binary masks. Recently, the concept of clinical target distribution (CTD),...
Authors: George X. Ding, Kenneth L. Homann
Affiliation: Vanderbilt University Medical Center
Abstract Preview: Purpose: It is standard practice that the beam monitor units (MUs) calculated by a commercial treatment planning system (TPS) is verified by a secondary dose calculation (SDC) software that independen...
Authors: Ross Bland, Zachary A. Christ, Sophy Mangana, Feba Mathew, Stephanie K. Phoenix, Joseph Salloum, Jason D. Stanford, William Zollinger
Affiliation: Forrest General Cancer Center, Northeast Louisiana Cancer Institute, Florida Atlantic University
Abstract Preview: Purpose: The objective of this paper is twofold: 1) to explore the efficacy of using referenced beam models supplied by the vendor (Brainlab) and 2) the efficacy of NIST traceable TLD for end-to-end v...
Authors: Kevin Peter Risolo
Affiliation: University of Pennsylvania
Abstract Preview: Purpose: To quantify the improved efficiency of checking patient treatment plan MU by utilizing RadFormation’s ClearCalc script-based program.
Methods: A total of 58 patients planned for treatment ...
Authors: Nuraddeen Nasiru Garba, Kalpana M Kanal, Abdullahi Mohammed, Rabiu Nasiru, Muhammad SHAFIU Shehu, Daniel Vergara, Joseph Everett Wishart
Affiliation: AHMADU BELLO UNIVERSITY, ZARIA, University of Washington
Abstract Preview: Purpose: To establish local Diagnostic Reference Levels (DRLs) for head and neck computed tomography (CT) exams in Abuja, Nigeria, and to investigate the performance of brain metastasis (BM) and brain...
Authors: Michael Cummings, Olga M. Dona Lemus, Hana Mekdash, Tyler Moran, Alexander R Podgorsak, Sean M. Tanny, Matthew J. Webster, Lexiang Yang, Dandan Zheng, Yuwei Zhou, Xiaofeng Zhu
Affiliation: Department of Radiation Oncology, University of Rochester, University of Miami, Inova Schar Cancer Institute, University of Rochester
Abstract Preview: Purpose: oART is revolutionizing radiotherapy by allowing treatment plans to be adjusted based on daily imaging, improving targeting precision and potentially enhancing patient outcomes. However, its ...
Authors: Andrew Groll, Ayan Mitra, PhD, Manoj Narayanan, Sanchit Sharma, Ray Yang, Timothy Pok Chi Yeung
Affiliation: Reflexion Medical Inc,, RefleXion Medical
Abstract Preview: Purpose: To develop a versatile QA tool enabling dose recalculation of a patient’s plan sinogram redeployed onto arbitrary replacement phantom geometry, and extract computed dose along detector planes...
Authors: Thomas Furno, Arjen Winkel, Ramtin Zakikhani
Affiliation: Genesis Care USA, QLRAD, SMH
Abstract Preview: Purpose: To quantify the dosimetric impact of the newly introduced “Inframammary Fold (IMF) Breast WedgeTM ” device by QLRAD inc. in the region of the inframammary fold during breast radiotherapy.
...
Authors: Hongyu Jiang
Affiliation: Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: This study presents a method for transforming coordinates from RayStation’s treatment planning system into the Monte Carlo (MC) coordinate system used in GEANT4 for dose calculations in spot ...
Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk
Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center
Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...
Authors: Michael Armstrong, Courtney R. Buckey, Quan Chen, Suzanne J. Chungbin, Mirek Fatyga, Yi Rong, Jun Tan, Xiang Sheng Yan
Affiliation: Mayo Clinic Arizona, Mayo Clinic
Abstract Preview: Purpose: To model a commercial rotational table in treatment planning system (TPS) for accurate dose optimization and calculation.
Methods: A commercial rotational table (CDR Equilibrium®) is r...
Authors: John T Barrett, Dan Heo, Chulhaeng Huh, Farshad Mostafaei
Affiliation: Department of Radiation Oncology, Medical College of Georgia, Augusta University, Department of Radiation Oncology, Augusta University
Abstract Preview: Purpose: This study aimed to compare the tumor control probability (TCP) of radiation therapy (RT) and magnetic hyperthermia combined with RT (MHRT) in the human prostate cancer cells based on radiobi...
Authors: Katrinus Keijnemans, Eric S. Paulson, An Tai
Affiliation: Department of Radiotherapy, University Medical Center Utrecht, Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Time-weighted mid-position images (MidPs), derived from four-dimensional computed tomography (4DCT) via deformable image registration (DIR), are frequently selected for treatment planning due...
Authors: Shane McCarthy, Damodar Pokhrel, William St. Clair, Eddy S Yang
Affiliation: University of Kentucky, Department of Radiation Medicine
Abstract Preview: Purpose: Demonstrating the feasibility of dose escalation for stereotactic recurrent head and neck (RHN) cancers through the deployment of a Hyper-Arc Based RapidPlan (HARP) model through an Eclipse S...
Authors: Laura I. Cervino, Wendy B. Harris, Paulo Quintero, Hao Zhang
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To evaluate the impact of the prediction uncertainty from CBCT-based synthetic CT (sCT) generation in abdominal adaptive radiotherapy.
Methods: CT and CBCT images from 65 abdominal pat...
Authors: Amy Berrington de Gonzalez, David Borrego, Rochelle Curtis, Gretchen L Gierach, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Lene Veiga, Jacqueline Vo
Affiliation: University of Michigan, East Carolina University, Radiation Protection Division, Office of Radiation and Indoor Air, U.S. Environmental Protection Agency, National Cancer Institute, Institute of Cancer Research
Abstract Preview: Purpose: Radiotherapy is vital for treating breast cancer, but its long-term health effects remain a concern. Accurate dose reconstruction is crucial for evaluating risks in retrospective epidemiologi...
Authors: Mingli Chen, Xuejun Gu, Hao Jiang, Mahdieh Kazemimoghadam, Weiguo Lu, Qingying Wang, Zi Yang, Kangning Zhang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, Stanford University School of Medicine
Abstract Preview: Purpose: Dose prediction (DP) is essential in guiding radiotherapy planning. However, current DP models for intensity-modulated radiation therapy (IMRT) primarily rely on fixed-beam orientations and a...
Authors: Julia Brosch-Lenz, Munir Ghesani, Francesc Massanes, Michael Morris, Babak Saboury, Eliot Siegel, Alexander Hans Vija
Affiliation: Institute of Nuclear Medicine, Siemens Medical Solutions USA Inc., Molecular Imaging
Abstract Preview: Purpose: Quantitative imaging of the radiopharmaceutical distribution is crucial for treatment evaluation and dosimetry. However, as patient numbers for Lutetium-177-(177Lu)-labelled therapies continu...
Authors: Jiankui Yuan, Dandan Zheng, Tingliang Zhuang
Affiliation: Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, University of Rochester, Varian Medical Systems, Advanced Oncology Solutions
Abstract Preview: Purpose: In Monte Carlo (MC) radiation therapy dose calculations, latent variance exists when directly applying phase-space files (PSF) with a finite number of source particles, while the latter is pr...
Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed
Affiliation: Bay Pines VA Medical Center
Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...
Authors: Jameson T. Baker, Sean T Grace, Cindy Pham, Michael A. Trager
Affiliation: Northwell
Abstract Preview: Purpose:
In VMAT planning, increasing complexity in MLC motion and modulation may improve dose distributions and OAR sparing while maintaining PTV coverage. However, increasing complexity can creat...
Authors: Avinash Mudireddy, Nathan Shaffer, Joel J. St-Aubin
Affiliation: University of Iowa
Abstract Preview: Purpose: This work demonstrates preliminary results in training a reinforcement learning (RL) network to perform VMAT machine parameter optimization.
Methods: We implemented a policy gradient RL al...
Authors: Casey E. Bojechko, Tricia Chinnery, Grace Gwe-Ya Kim, Xenia Ray
Affiliation: University of California San Diego
Abstract Preview: Purpose: To evaluate the use of a calibration curve generated from the CT simulator for direct dose calculation on cone beam computed tomography (CBCT) images taken with the on-board imaging system. T...
Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Gunjan Kayal, Adam Leon Kesner, Harry Marquis, Juan Camilo Ocampo Ramos, Stefan Wehmeier
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson
Abstract Preview: Purpose: Accurate organ dose estimation in computed tomography (CT) has gained attention due to the increasing global utilization of CT imaging. MIRDct, a specialized CT dosimetry software, has recent...
Authors: Brook Byrd, Lisha Chen, Michael LaRiviere, Baozhu Lu, John Plastaras, Brian W Pogue, Emily Xiong, Timothy C. Zhu, Yifeng Zhu
Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania, University of Wisconsin - Madison
Abstract Preview: Purpose: For total skin electron therapy (TSET), achieving optimal dose distribution depends on precise patient positioning, which is often influenced by daily variability. Cherenkov imaging offers a ...
Authors: Farhad Jafari, Brandon Hai Nguyen
Affiliation: Department of Radiation Oncology, University of Minnesota Medical School, Department of Radiology, University of Minnesota
Abstract Preview: Purpose: To validate a bottom-up approach to dosimetry in nuclear medicine.
Methods: A pharmacokinetic model is developed to represent the flow of activity between different compartments of the...
Authors: Michael Evan Chaga, Timothy Chen, Shabbar Danish, Jesse Feng, Joseph Hanley, Georg A. Weidlich
Affiliation: Zap Surgical, Tenafly High School, Jersey Shore University Medical Center
Abstract Preview: Purpose: ZapMU is the first independent monitor unit check software freely available supporting ZAP-X. In this study, the validation of ZapMU for independent check of dose calculation is performed, ut...
Authors: Klaus Bacher, Louise D'hondt, Jeff Rutten, Gwenny Verfaillie
Affiliation: Ghent University
Abstract Preview: Purpose: Manual organ segmentation is a very time-consuming but necessary process in personalized dosimetry. Automatic segmentation tools may alleviate this task. In this study the impact of automatic...
Authors: Jae Won Jung, Choonsik Lee, Jason C. Mace, Sergio Morato Rafet
Affiliation: East Carolina University, Carilion Clinic, National Cancer Institute
Abstract Preview: Purpose: Dosimetry for radionuclides used in nuclear medicine can be accurately calculated if sufficient data is available. However, in most cases crucial information cannot or will not be known a pri...
Authors: Srinivas Cheenu Kappadath, Benjamin P. Lopez, Armeen Mahvash
Affiliation: UT MD Anderson Cancer Center
Abstract Preview: Purpose: 90Y-radioembolization is utilized with curative intent. While single-compartment doses to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actu...
Authors: Kristy K. Brock, Austin Castelo, Yulun He, Zhongxing Liao, Rebecca Lim, Radhe Mohan, Caleb O'Connor, Tien T Tang, Uwe Titt
Affiliation: University of Washington, The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center
Abstract Preview: Purpose: Conformal dose distributions in proton radiotherapy promise to reduce normal tissue toxicity such as radiation-induced pneumonitis, but this has not been fully realized in clinical trials. To...
Authors: Hilary Louisa Byrne, Owen Thomas Dillon, Paul J. Keall, Hunor Kertesz, Ricky O'Brien, Tess Reynolds
Affiliation: University of Sydney, Image X Institute, Faculty of Medicine and Health, The University of Sydney, Medical Radiations, School of Health and Biomedical Sciences, RMIT University
Abstract Preview: Purpose: Imaging of lung motion and function has typically required multiple volumetric CT images to create deformation vector fields (DVF) for motion and ventilation images (function). However, CT sc...
Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag
Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia
Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...