Search Submissions 🔎

Results for "dosimetric differences": 121 found

A Comparative Analysis of the Dosimetric, Alignment, and Setup Efficiency in Left Breast Cancer Radiotherapy Treated with Dibh Using ABC and Sgrt

Authors: Aaron Conard, Victoria Croog, Marie Gurka, Lan Lin

Affiliation: Johns Hopkins University

Abstract Preview: Purpose:
This study evaluates the utility of the Active Breathing Coordinator (ABC) and Surface Guided Radiation Therapy (SGRT) techniques in implementing Deep Inspiration Breath Hold (DIBH) for le...

A Comparison of Non-Adaptive Versus Online Adaptive Radiotherapy for Prostate Cancer Using FLOW-RT-- Fast, AI-Driven but Learning-Enabled, Online Adaptive Workflow for Radiotherapy

Authors: Theodore Higgins Arsenault, Kenneth W. Gregg, Beatriz Guevara, Lauren E Henke, Angela Jia, Rojano Kashani, Kyle O'Carroll, Alex T. Price, Adithya Reddy, Atefeh Rezaei, Daniel E Spratt, Runyon C. Woods

Affiliation: University Hospitals Seidman Cancer Center

Abstract Preview: Purpose: To evaluate the effect of unedited AI-generated contours used for online adaptive radiotherapy (FLOW-ART) on the plan quality of prostate treatments as compared to non-adaptive (non-ART) proc...

A Ground Truth Label-Mediated Method for Improved Bone and Gas Cavity Definition for MRI-Guided Online Adaptive Radiotherapy Workflows Using Synthetic CT Images.

Authors: Benito De Celis Alonso, Braian Adair Maldonado Luna, Gerardo Uriel Perez Rojas, René Eduardo Rodríguez-Pérez, Kamal Singhrao

Affiliation: Department of Radiation Oncology, Brigham and Women's Hospital, Dana Farber Cancer Institute, Harvard Medical School, Faculty of Physics and Mathematics, Benemérita Universidad Autónoma de Puebla

Abstract Preview: Purpose: Artificial Intelligence (AI)-generated synthetic CT (sCT) images can be used to provide electron densities for dose calculation for online adaptive MRI-guided stereotactic body radiotherapy (...

A Modified VMAT Technique for the Treatment of Diffuse and Extensive Involvement of the Skull By Various Malignancies

Authors: Edward D. Brandner, Weihua Fu, M. Saiful Huq, Ronald John Lalonde, Kiran Mehta, Hima Bindu Musunuru, Yongqian Zhang

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, University of Pittsburgh School of Medicine and UPMC Hillman CancerCenter

Abstract Preview: Purpose: Treatment of diffuse and extensive involvement of the skull by malignancy presents a difficult challenge for radiation therapy. This study reports preliminary experience of a modified volumet...

A New Voxel-Based Similarity Approach for Assessing Contour Similarity and Clinical Dosimetric Effect

Authors: Shari Damast, Svetlana Kuznetsova, Christopher J. Tien

Affiliation: Yale University School of Medicine, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: Current contour similarity evaluation approaches (Dice Similarity Coefficient, Mean Distance to Agreement) are limited to geometric agreement without assessment of ultimate dosimetric impact....

A Novel Metric for Predicting Heart Dose Assessment in Left-Sided Breast Cancer Radiotherapy

Authors: Yufeng Cao, Arun Gopal, Kai Huang, Kai Wang

Affiliation: Department of Radiation Oncology, University of Maryland School of Medicine, Department of Radiation Oncology, University of Maryland Medical Center, University of Maryland, Baltimore

Abstract Preview: Purpose: The treatment of left-sided breast tumors poses significant concerns regarding the risk of radiation-induced damage to nearby organs, particularly the heart. In clinical practice, breath-hold...

AI Auto-Contouring for CT-Based High-Dose-Rate Interstitial Brachytherapy of Cervical Cancer: Implications for Organ-at-Risk (OAR) Contouring and Dosimetric Analysis

Authors: Indrin J. Chetty, Jing Cui, Mitchell Kamrava, Tiffany M. Phillips, Jennifer M. Steers, Brad Stiehl

Affiliation: Department of Radiation Oncology,Cedars-Sinai Medical Center, Cedars-Sinai Medical Center

Abstract Preview: Purpose: Auto-contouring for HDR interstitial brachytherapy can be confounded by large deformation in anatomy and image quality. Here we evaluated the performance of an AI-based auto-contouring softwa...

An International Multi-Institutional Espresso Study of Developing the Specialized-Equipment-Free Remote Audit for Single-Isocenter Multi-Target Stereotactic Radiosurgery

Authors: Juan-Francisco Calvo-Ortega, Andrew Cousins, Ashley Cullen, Andrew Dipulia, Peter B. Greer, Seng Boh Gary Lim, Shih-Chi Lin, D. Michael Lovelock, Conor McGarry, Victoria Robinson, Cameron Stanton, Baozhou Sun, Ching-Ling Teng, Gemma Warner, Benjamin J. Zwan

Affiliation: Northern Ireland Cancer Centre, Baylor College of Medicine, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Christchurch Hospital, Northwell, Central Coast Cancer Centre, Calvary Mater Hospital, Hospital Quironsalud Barcelona, Icahn School of Medicine at Mount Sinai, Chris O'Brien Lifehouse, University of Newcastle

Abstract Preview: Purpose: This multi-institution Electronic Silicon-based Remote Survey of Small-field Output (ESPRESSO) study aims to develop the remote audit process to evaluate the safety of single-isocenter multi-...

An OAR Margin Recipe Based on Clinical Data and Including Radio-Sensitivity Variation

Authors: Carlo Greco, Joep Stroom, Sandra Vieira

Affiliation: Champalimaud Center for the Unknown

Abstract Preview: Purpose: RTP safety margins are generally based on geometrical uncertainties alone and not directly on clinical outcome. Here we use clinical dose-constraint data to generate dosimetric margins for OA...

Application and Analysis of Advanced 3D Printed Materials As Bolus for Radiation Therapy

Authors: Rami M. Shorti, Gary R. Stinnett

Affiliation: Intermountain Health, Radiation Oncology, Intermountain Health, Advanced Visualization Engineering Department

Abstract Preview: Purpose: In this work we present the workflow, materials analysis, and lessons learned from leveraging advanced 3D printing Polyjet Technology to print conformal bolus for radiation therapy.
Method...

Assessing Mlc Errors and Their Dosimetric Impact Delivered on Elekta Linear Accelerator from Two TPS Systems

Authors: Richard Lesieur, Olivia Magneson, David E. Solis, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center

Abstract Preview: Purpose: This study evaluates the deliverability and precision of multileaf collimator (MLC) positioning in treatment plans generated by two different Treatment Planning Systems (TPS), Monaco and Pinn...

Assessing the Impact of Intrafraction Shifts on Critical OAR Doses in a Standardized Spine SBRT Program

Authors: Daniel A. Alexander, Anish Butala, Anthony Austin Kassaee, Neil Malhotra, Ian Messing, Gabrielle W Peters, Ryan M. Scheuermann

Affiliation: Department of Radiation Oncology and Applied Sciences, University of Pennsylvania

Abstract Preview: Purpose: Stereotactic Body Radiation Therapy (SBRT) for spinal metastases uses CBCT-based localization and highly conformal treatment delivery to increase the biologically equivalent dose to the targe...

Assessment of Daily Target Volume and Dose Variations in Adaptive MR-Guided Radiotherapy for Pancreatic Cancer Patient

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Haley Park, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Tino Romaguera, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose:
Pancreatic cancer poses therapeutic challenges due to the proximity of critical organs, requiring precise radiotherapy. Magnetic resonance (MR)-guided linear accelerators provide daily ima...

Assessment of Deep Learning Models for 3D Dose Prediction in Prostate Cancer SIB-IMRT Using MR-Linac

Authors: Hao-Wen Cheng, Jonathan G. Li, Chihray Liu, Wen-Chih Tseng, Guanghua Yan

Affiliation: University of Florida

Abstract Preview: Purpose: This study develops and evaluates deep learning (DL) models for predicting 3D dose distributions in simultaneous integrated boost (SIB) prostate cancer treatment using the Elekta Unity MR-Lin...

Assessment of Off-Target Dose for Curative Treatment of Pregnant Head and Neck Cancer Case: A Monte-Carlo Study

Authors: Brianna Baek, David J. Carlson, Zhe (Jay) Chen, Dae Yup Han, Bon Tack Koo, Hyojun Park

Affiliation: Columbia University, Canyon Crest Academy, Department of Therapeutic Radiology, Yale University School of Medicine, Department of Radiation Oncology, Chung-Ang University Gwang Myeong Hospital

Abstract Preview: Purpose: To find an optimized treatment technique and shielding design for minimizing the dose to a fetus, a Monte-Carlo simulation was performed to evaluate the dosimetric contribution.
Methods: G...

Automatic Contour Quality Assurance Using Deep-Learning Based Contours

Authors: Laurence Edward Court, Raphael Douglas, David Fuentes, Anuja Jhingran, Barbara Marquez, Raymond Mumme, Christine Peterson, Julianne M. Pollard-Larkin, Surendra Prajapati, Dong Joo Rhee, Thomas J. Whitaker

Affiliation: MD Anderson Cancer Center, The University of Texas MD Anderson Cancer Center, MD Anderson, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Safe deployment of auto-contouring models requires the inclusion of automated quality assurance (QA). One approach is to use an independent auto-contouring model and compare the contours geom...

Bridging the Gap of Radiotherapy Planning Quality between a High-Income Countrie to a Middle-Income Country By the Dosimetric Validation of a KBP Model Vs Junior, Senior Dosimetrists and MCO Planning

Authors: Eduardo Florian, Hiram Gay, Geoffrey D. Hugo, Otto Hurtarte, Milton Ixquiac, Erick Orlando Montenegro, Franky Eduardo Reyes, Francisco Javier Reynoso, Edgar Aparicio Ruiz, Baozhou Sun, Jacaranda Van Rheenen, Kevin Vega, Angel Velarde, Vicky de Falla

Affiliation: WashU Medicine, Liga Nacional Contra el Cancer, Liga Nacional Contra el Cancer/INCAN, Liga Nacional Contra el Cancer / INCAN, Liga Nacional Contra el Cancer and Universidad de San Carlos de Guatemala, Washington Univ. in St. Louis, Liga Nacional Contra el CĂĄncer / INCAN, Washington University in St. Louis, Varian, Baylor College of Medicine

Abstract Preview: Purpose:
IMRT has become the standard of care in high-income countries (HICs) due to reduced toxicity and improved treatment outcomes.
The purpose of this work is validating the KBP model shared...

CBCT-Based Synthetic CT Imaging for Proton and Photon Dose Monitoring and Adaption in Supine Breast Radiotherapy

Authors: Mark E Artz, Julie Bradley, Hardev Singh Grewal, Perry B. Johnson, Christina Klassen, Raymond Mailhot Vega, Nancy Mendenhall, Jiyeon Park, Emma V. Viviers, Yawei Zhang

Affiliation: UF Health Proton Therapy Institute, University of Florida

Abstract Preview: Purpose: Verification CTs (VFCT) are used in radiotherapy to assess patient dose during treatment. However, they are time-consuming and contribute additional radiation exposure to the patient. This st...

Can Contrast Scans of Dual-Layer Detector Spectral CT be Directly Used for Proton Dose Calculations?

Authors: Wen C. Hsi, Pouya Sabouri, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose:
Traditional single-energy CT (SECT) contrast scans cannot be used for proton dose calculations due to significantly higher HU caused by iodine. Dual-layer dual-energy CT (DL-DECT) can dire...

Case-By-Case Analysis of Proton Spot Spacing and Dosimetric Variability in Proton Arc Lung Cancer Planning

Authors: Nebi Demez, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is an advanced proton therapy technique that leverages pencil beam scanning to deliver dose to the patient while the gantry rotates around the patient. This study investigates the ...

Characterizing a VMAT Optimization Algorithm with Integrated Static-Angle Modulated Ports for Esophageal Cancer Treatment

Authors: Lei Dong, Yin Gao, Taoran Li, Michael Salerno, Boon-Keng Kevin Teo, Melissa Vila

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: A novel solution, RapidArc Dynamic-RAD (Varian Medical Systems, Palo Alto, USA) has been implemented to integrate VMAT with modulation of IMRT-like static-angle ports, including use of a dyna...

Clinical Assessment of Synthetic CT in MR-Only Brain Radiotherapy

Authors: Ergun E. Ahunbay, Colette Gage, Abdul Kareem Parchur, Eric S. Paulson

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: AI-generated synthetic CT (sCT) images address challenges with prior sCT approaches, including atlas- and threshold-based methods. Commercial AI-based sCT tools have been introduced. This wor...

Commissioning a Comprehensive Workflow for VMAT Total Body Irradiation (TBI) Using Publicly and Commercially Available Resources

Authors: Alan H. Baydush, Sarah Cummings, Jeffrey Michael Fenoli, Christy Hickerson, Lalith Kumaraswamy, Philmo Oh, Sarah B. Wisnoskie

Affiliation: Novant Health Cancer Institute, Novant Health

Abstract Preview: Purpose: To develop, validate, and commission a VMAT Total Body Irradiation (TBI) workflow by integrating publicly available resources, commercial solutions, and in-house testing to enhance treatment ...

Commissioning and Evaluation of Deviceless 4DCT

Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor

Affiliation: Oregon Health & Science University, Northwest Medical Physics Center

Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...

Comparative Evaluation of Spekpy for Kilovoltage Beam Quality Characterization

Authors: Chang Heon Choi, Yoonsuk Huh, Jin Jegal, Seonghee Kang, Jung-in Kim, Inbum Lee, Hyojun Park

Affiliation: Department of Radiation Oncology, Seoul National University Hospital

Abstract Preview: Purpose: This study evaluates SpekPy, a Python-based tool for modeling kilovoltage (kV) x-ray spectra, by comparing its calculated energy spectra, half-value layer (HVL), and air kerma with experiment...

Comparison of Portal Dosimetry and Delta4Âź for Pretreatment QA of Sfrt-VMAT Plans

Authors: Tianyuan Dai, Zejun Jiang, Xiangyue Kong

Affiliation: Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose:
This study aims to evaluate the reliability of SFRT-VMAT plan verification by comparing two QA methods: Portal Dosimetry (PD) and Delta4Âź.
Methods:
Preteatment QA was conducted for 1...

Consecutive Daily Fractions with Itv Boost Are Safe for Treating Central Non-Small Cell Lung Cancer Using Stereotactic Body Radiation.

Authors: Baher Elgohari, M. Saiful Huq, Ronald John Lalonde, Fang Li, Noor Mail, Jeonghoon Park, Tyler Wilhite

Affiliation: UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, UPMC, Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose:
To compare toxicity between consecutive-daily (QD) with every-other-day (QoD) delivery of lung stereotactic-body-radiation (SBRT) for central non-small-cell lung cancer (NSCLC).
Methods...

Daily Adaptive Treatment Planning with Radixact for Head and Neck Cancer: A Dosimetric Evaluation

Authors: Yong Chen, Christina Henson, Yuchen Qiu, Marti Roper

Affiliation: University of Oklahoma HSC, University of Oklahoma Health Sciences Center, University of Oklahoma, University of Oklahoma Health Science Center

Abstract Preview: Purpose: Traditionally, Head and Neck cancer patients have one or two treatment replans through their treatment course, which fails to account for anatomical changes in position, weight loss, or tumor...

Design, Optimization, and Preclinical Validation of a Novel Applicator Integrating Real-Time Dose Monitoring for Ultra-High Dose Rate (FLASH) Electron Radiotherapy

Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali

Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council

Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...

Determining the Effect of Motion during Gamma Knife Stereotactic Radiosurgery on Anterior and Posterior Lesions Using an Anthropomorphic Phantom

Authors: Guang-Pei Chen, Nitish Chopra, Juan A. Garcia-Alvarez, Mi Huang, Slade J. Klawikowski, Haidy G. Nasief, George A. Noid, Abdul Parchur, Eric S. Paulson, Christina M. Sarosiek, Christopher Schultz

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: During routine delivery of mask-based Gamma Knife (GK) SRS, motion is tracked via the position of a reflective sticker placed on the patient’s nose relative to two stationary reflectors on th...

Development and Implementation of MRI-Only Simulation, Planning and Treatment Workflow for Pelvic Radiotherapy Using Synthetic CT on MR-Linac

Authors: Peter Balter, Elaine Eunnae Cha, Seungtaek Choi, Yao Ding, Eun Young Han, Yusung Kim, Rajat J. Kudchadker, Belinda Lee, Surendra Prajapati, Reza Reiazi, Ergys D. Subashi, Sarath Vijayan, Jinzhong Yang, Yao Zhao

Affiliation: The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: This study evaluates the feasibility of an MR-only simulation, planning, and treatment (MROSPT) workflow for pelvic cancer patients using synthetic CT generated from MRI data. By validating s...

Development and Validation of a Principal Component Analysis Statistical Shape Pediatric/Adolescent Breast Model for Pre-CT Era Breast Dose Reconstruction in Late Effect Studies of Female Childhood Cancer Survivors

Authors: Gregory T. Armstrong, James E. Bates, Kristy K. Brock, Laurence Edward Court, Matt Ehrhardt, Danielle Friedman, Aashish C. Gupta, Donald Hancock, Rebecca M. Howell, Cindy Im, Tera S Jones, Choonsik Lee, Wendy Leisenring, Taylor Meyers, Lindsay Morton, Chaya Moskowitz, Joe Neglia, Vikki Nolan, Caleb O'Connor, Kevin C. Oeffinger, Constance A. Owens, Arnold C. Paulino, Chelsea C. Pinnix, Sander Roberti, Cecile Ronckers, Susan A. Smith, Kumar Srivastava, Lucie Turcotte

Affiliation: Department of Medicine, Duke University School of Medicine, Department of Epidemiology and Cancer Control, St. Jude Children’s Research Hospital, The University of Texas MD Anderson Cancer Center, Department of Oncology, St. Jude Children’s Research Hospital, Department of Pediatrics, Memorial Sloan Kettering Cancer Center, Division of Pediatric Epidemiology and Clinical Research, University of Minnesota, Division of Childhood Cancer Epidemiology, University Medicine at Johannes Gutenberg University Mainz, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Department of Pediatrics, University of Minnesota, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Department of Biostatistics, St. Jude Children’s Research Hospital, Clinical Research Division, Fred Hutchinson Cancer Center, Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Department of Epidemiology and Biostatistics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Department of Radiation Oncology and Winship Cancer Institute, Emory University, The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences

Abstract Preview: Purpose: To (1) develop and validate a novel anatomically realistic pediatric/adolescent population-based breast model, (2) incorporate model into an age-scalable female reference phantom, and (3) dem...

Development of a Quantitative Surface Mapping Analysis Framework Involving a Robust Mask Removal Algorithm for Improved Objective Patient Setup Assessment in Head and Neck Intensity Modulated Proton Therapy

Authors: Grant Evans, Maxwell Arthur Kassel, Charles Shang, Michael H. Shang, Stephen Shang, Timothy R Williams

Affiliation: South Florida Proton Therapy Institute, SFPRF, Department of Radiation Medicine, MedStar Georgetown University Hospital

Abstract Preview: Purpose:
Daily image guidance for head and neck intensity-modulated proton therapy (IMPT) presents significant challenges due to large target volumes and anatomical changes. Geometric deviations al...

Development of an Inverse Treatment Planning System for Precision Small Animal Radiotherapy

Authors: Zihao Liu, Qiwei Wu, Yanfei Xiong, Yidong Yang, Ning Zhao

Affiliation: Department of Engineering and Applied Physics, School of Physical Sciences, University of Science and Technology of China, Department of Engineering and Applied Physics, University of Science and Technology of China, University of Science and Technology of China

Abstract Preview: Purpose: To develop an inverse planning framework that optimizes beam angles and intensities for small animal radiotherapy and to validate its accuracy and effectiveness.
Methods: The inverse plann...

Dosimeteric Parameter Evaluation of Digital Polycrystalline Semiconductor Dosimeters for Quality Assurance of High-Dose-Rate Brachytherapy

Authors: Woong Cho, Jin-Beom Chung, Moo-Jae Han, Sang Won Kang, Boram Lee

Affiliation: Department of Radiation Oncology, Seoul National University Boramae Medical Center, Department of Radiation Oncology, Seoul National University Bundang Hospital, Department of Radiation Oncology, Inha University Hospital

Abstract Preview: Purpose: This study aims to establish a digital quality assurance (QA) system for high-dose-rate (HDR) brachytherapy by evaluating self-developed polycrystalline semiconductor dosimeters (PSDs).
Me...

Dosimetric Accuracy Evaluation of Brainlab Elements 4.0 Treatment Planning System

Authors: Bhuvaneswari Narayanan, Niko Papanikolaou, Daniel L. Saenz

Affiliation: UT Health San Antonio, University of Texas HSC San Antonio

Abstract Preview: Purpose: To evaluate dosimetric accuracy of Brainlab Elements (BLE) 4.0 treatment planning system (TPS) for linac based SRS and Spine SBRT treatment.
Methods: RT Safe cranial and thorax phantoms wi...

Dosimetric Analysis of Lymphopenia after Lung Irradiation and Modeling the Probability of Normal Tissue Complications

Authors: Tianyuan Dai, Xiaoying Fan, Shuting Wang, Yong Yin

Affiliation: Department of Graduate, Shandong First Medical University, Shandong Academy of Medical Sciences, Department of Radiation Oncology Physics and Technology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences

Abstract Preview: Purpose: Decreased lymphocytes increase the risk of infections and other problems. Radiation exposure can cause the development of severe lymphopenia. In this study, we used a dynamic blood flow model...

Dosimetric Analysis of Plans Using X-Ray and X-Îł-Ray Combination Strategy for Advanced Cervical Cancer Patients with Pelvic Lymph Node Metastasis

Authors: Yi Li

Affiliation: Department of Radiation Oncology, the First Affiliated Hospital of Xi'an Jiaotong University

Abstract Preview: Purpose: Advances in radiotherapy technology are crucial for improving cervical cancer (CC) treatment. This study explores a novel X-ray and Îł-ray dual-modality radiation (TaiChiB) system, comparing i...

Dosimetric Changes of Magnetic Control System to Improve Anatomy in Abdominal SBRT

Authors: Justus Adamson, Wesley Andrew Cunningham, Chang-Sei Kim, Yeongoh Ko, Anna E. Rodrigues

Affiliation: Duke University, Chonnam National University, Duke University Medical Center

Abstract Preview: Purpose: Radiation induced toxicities in bowel remains a challenge for SBRT. Due to sharp dose falloffs, small displacements of the bowel can lead to meaningful dose reduction. Remote magnetic navigat...

Dosimetric Characteristics of a Commercially Available Platinum Cured Silicone Rubber Material As a Custom Bolus Option

Authors: Jordan B Lunsford, Sagar Pokhrel, Ashkan Shafiee, Curtis S. Whiddon

Affiliation: Atrium Health Wake Forest Baptist, University of North Carolina, Atrium Health Wake Forest Baptist High Point Medical Center

Abstract Preview: Purpose: To investigate the dosimetric characteristics of a platinum cured silicone rubber material (Platsil) for use as custom bolus in radiotherapy
Methods: Sheets of 2, 4, 6, and 8 mm Platsil we...

Dosimetric Comparison & Error Analysis of Aapm TG51 & WGTG51-e Protocol with Icru-90 Key-Data for High-Energy Clinical Electron Beam

Authors: Amar K. Basavatia, Sandeepan Ganguly, Lee C. Goddard, Wolfgang A. Tomé

Affiliation: Montefiore Medical Center

Abstract Preview: Purpose: To investigate the dosimetric impact of WGTG51-e Report 385, recently updated CoP for clinical electron beams. This study uses a chamber specific effective point of measurement (EPOM) shift t...

Dosimetric Comparison for Bladder Cancer Patients Treated with Adaptive Planning

Authors: Ahmad Amoush, Adam C. Riegel

Affiliation: Columbia University Irving Medical Center

Abstract Preview: Purpose: To investigate the dosimetric differences between the reference CT plan, the scheduled plan, and the adaptive plan for a bladder cancer patient treated with Varian Ethos system.
Methods: A...

Dosimetric Comparison of 6X and 10X Flattening Filter-Free Photon Beams on a Truebeam Linac Using the Eclipse TPS

Authors: Carlos E. Cardenas, Udbhav S. Ram, Marcin Wierzbicki

Affiliation: The University of Alabama at Birmingham, University of Alabama at Birmingham, Juravinski Cancer Centre

Abstract Preview: Purpose:
This study aims to systematically evaluate the dosimetric properties and delivery efficiency of 6X-FFF and 10X-FFF beams for lung SBRT on the Varian TrueBeam STx using the Eclipse TPS 16.1...

Dosimetric Comparison of Lattice and 3D Grid VMAT Planning for Spatially Fractionated Radiotherapy

Authors: Minbin Chen, Gang Liu, Manju Liu, Weiwei Sang, Pulin Sun, Mingyuan Ye, Fang-Fang Yin, Lihua Zhang, Haiming Zhu

Affiliation: Jiahui International Hospital, Radiation Oncology, Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Medical Physics Graduate Program, Duke Kunshan University, Duke Kunshan University, The First People's Hospital of Kunshan

Abstract Preview: Purpose: This study aims to conduct a dosimetric comparison between lattice radiotherapy (LRT) and 3D grid treatment planning techniques, focusing on their differences in delivering three-dimensional ...

Dosimetric Evaluation of Clinical Venezia Hybrid Applicator Plans Using a TG-186 Model-Based Dose Calculation Algorithm

Authors: Davide Brivio, Ivan M. Buzurovic, Thomas C. Harris, Desmond A. O'Farrell

Affiliation: Department of Radiation Oncology, Brigham and Women’s Hospital, Dana-Farber Cancer Institute, Harvard Medical School, Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology

Abstract Preview: Purpose: Cervical cancer can be treated with a brachytherapy boost following external beam radiotherapy. One applicator option is the Advanced Gynecological Applicator "Venezia" (Elekta) hybrid, consi...

Dosimetric Evaluation of a Helical Tomotherapy to L-Shaped Linac Plan Conversion Workflow

Authors: Megan E. Daly, Ryan D. Hernandez, Abriel J. Horak, Soo Kyoung Kim, Peter C. Park, Dwaine O. Spence, Payton H. Stone, Cari L. Wright

Affiliation: UC Davis Cancer Center

Abstract Preview: Purpose: To evaluate a fallback planning workflow used for cross-modality treatment planning and delivery between helical Tomotherapy and volumetric modulated arc therapy (VMAT) using conventional L-s...

Dosimetric Evaluation of a Three-Dimensional Cubic Electronic Detector Array for Radiotherapy Linac Quality Assurance

Authors: Enzo Charles Aucca, Roger Challco, Andres M. Gonzales Galvez, Carmen SANDRA Guzman Calcina, Jimmy Hernandez-Bello, Modesto Montoya, Renzo Aaron Ocampo, Erick Paniagua, Miguel Alberto Risco-Castillo, Dante E. Roa, Renzo E. Romero, William Souza Santos, Mirko SalomĂłn Alva SĂĄnchez

Affiliation: Graduate Program in Information Technologies and Health Management, University of Porto AlegreFederal University of Health Sciences of Porto Alegre, Universidad Tecnologica del Peru, Pontificia Universidad Catolica del Peru, Electronic Engineering Department, Leonard Cancer Institute - Radiation Oncology, Universidad Nacional de Ingenieria, Universidad Nacional de Ingenieria, Electronic Engineering Department, Federal University of Sergipe, HRS Oncology International, Universidad Nacional Federico Villareal

Abstract Preview: Purpose: Provide Monte Carlo (MC) and experimental dosimetric assessments of a 3D cubic electronic detector array based on percent depth doses (PDDs), profiles, linearity, and dose rate response of ph...

Dosimetric Feasibility of Dominant Intraprostatic Lesion Dose Escalation in HDR Prostate Brachytherapy

Authors: Abby E. Besemer, Carolyn Eckrich, John M. Floberg, Michael J. Lawless, Jessica R. Miller, Joseph B. Schulz, Jordan M. Slagowski, Autumn E. Walter-Denzin

Affiliation: University of Wisconsin-Madison Department of Medical Physics, University of Wisconsin-Madison Department of Human Oncology, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Department of Radiation Oncology, Stanford University School of Medicine, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: The aim of this treatment planning study was to evaluate the feasibility of escalating dose with HDR prostate brachytherapy to imaging-identified intraprostatic macroscopic lesions while mode...

Dosimetric Impact of Auto-Segmentation with Replanning: An Analysis of a Prospective Clinical Trial

Authors: Kathryn J. Dess, Martha M. Matuszak, Dan Polan

Affiliation: University of Michigan

Abstract Preview: Purpose: A recent survey demonstrated 18 of 20 top academic institutions have implemented auto-segmentation. Studies to date have focused on geometric contour changes and dosimetric differences using ...

Dosimetric Impact of Calculation Grid Size in ZAP-X Stereotactic Radiosurgery

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: ZAP-X is the newest cranial stereotactic radiosurgery (SRS) platform. Small-volume structures usually found in the head and neck may be susceptible to dose-volume averaging, which has not bee...

Dosimetric Impact of Monte Carlo Physics Models in Electronic Brachytherapy Simulations

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Jan P. Seuntjens, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Princess Margaret Cancer Centre & University of Toronto, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta, Université Laval, Carleton Laboratory for Radiotherapy Physics, Department of Physics, Carleton University

Abstract Preview: Purpose: Low-energy X-ray beams used in electronic brachytherapy (eBT) pose unique dosimetric challenges due to high depth-dose gradients, material-dependent detector responses, and the absence of sta...

Dosimetric Parameter Cross-Check Evaluations for Dedicated Biologically-Guided Radiotherapy Linac Using Two Water Phantom Systems

Authors: Nguyen Phuong Dang, Mason Hazlett, Lijun Ma, Yutaka Natsuaki, William T. Watkins, Zhengzheng Xu, Timothy Pok Chi Yeung

Affiliation: Reflexion Medical Inc,, Radiation Oncology, Keck School of Medicine of USC, RefleXion Medical, Department of Radiation Oncology, City of Hope National Medical Center

Abstract Preview: Purpose: This is the first study reporting the beam dosimetric parameter cross-checks of Reflexion linac using different water phantom systems and detectors. The difference in measurements using diffe...

Dosimetric Variations Induced By Inaccurate Collimator Angles in Single-Isocenter SRS Plan for Multi-Lesion Brain Metastases

Authors: Makunda Aryal, Gregory Bartlett, David D. Campos, Ke Colin Huang, Sook Kien Ng, Christopher F. Njeh, Oluwaseyi Oderinde, Edwin Quashie, Ashok Tiwari, Yong Yue

Affiliation: Purdue University, Department of Radiation Oncology, Indiana University, Indiana University, Indiana University School of Medicine, Department of Radiation Oncology

Abstract Preview: Purpose:
Linear accelerator-based single-isocenter Stereotactic Radiosurgery (SRS) is widely used for treating brain metastases due to its efficiency, reduced treatment time, and lower imaging dose...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Dysphagia Optimized Knowledge-Based Planning for Head and Neck Cancer

Authors: James E. Bates, Benjamin Hopkins, Kirk Luca, Shadab Momin, Justin R. Roper, Soumon Rudra, Eduard Schreibmann, Bill Stokes, Tu Thi, Xiaofeng Yang

Affiliation: Emory University, Department of Radiation Oncology and Winship Cancer Institute, Emory University

Abstract Preview: Purpose: Swallowing dysfunctions after radiotherapy are caused by multiple factors yet are strongly associated with the irradiation of pharyngeal musculature due to its role in the initiation and comp...

EBT4 Film Dosimetry and the Significance of the Œ Fwhm Rule for Gamma Knife Output Factors

Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic

Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center

Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Electronic Brachytherapy Dosimetric Reference Datasets Using Model-Based Dose Calculation Algorithms

Authors: David Ayala Alvarez, Facundo Ballester, Luc Beaulieu, Francisco Berumen-Murillo, Jean-Simon Cote, Ernesto Mainegra-Hing, Iymad Mansour, Gaël Ndoutoume-Paquet, Rowan M. Thomson, Christian Valdes, Javier Vijande, Peter G. Watson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, Laval University, Princess Margaret Cancer Centre, McGill University, Department of Physics and Medical Physics Unit, McGill University, IFIC-UV, University of Valencia, National Research Council Canada, Carleton University, 5Service de Physique Médicale et de Radioprotection, Centre Intégré de Cancérologie, CHU de Québec- Université Laval et Centre de recherche du CHU de Québec, Nuclear Medicine Department, Hospital Regional de Antofagasta

Abstract Preview: Purpose: Modelling electronic brachytherapy (eBT) sources is difficult because of the high-dose gradients and challenges associated with low-energy modelling. This study examines the accuracy of avail...

Evaluating Dose Variability in Bladder Contouring for MR-Guided Prostate Cancer Radiotherapy

Authors: Emily Helen Hayes, Chihray Liu

Affiliation: University of Florida

Abstract Preview: Purpose: To evaluate dosimetric discrepancies in bladder dose calculations among rigid, deformed, and manual contouring methods in prostate cancer patients and assess dose variations resulting from bl...

Evaluating Necessity of Patient-Specific Deep Learning-Based Auto-Segmentation for Improved Adaptation for Abdominal Tumors

Authors: Asma Amjad, Renae Conlin, Eric S. Paulson, Christina M. Sarosiek

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: In an effort to improve contouring accuracy for abdominal MR guided online adaptive radiotherapy (MRgOART), patient-specific deep learning-based auto-segmentation (PS-DLAS) has been proposed....

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Evaluating the Impact of Spot Spacing on Dosimetric Outcomes in Dynamic Arc Proton Therapy for Prostate SBRT

Authors: Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Umesh Rana, Hina Saeed, Nishan Shrestha, Somol Sunny

Affiliation: Florida Atlantic University, Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: DynamicARC is a novel pencil beam scanning (PBS) proton therapy technique with the potential to provide more conformal dose distributions and reduce treatment time. This study investigates th...

Evaluating the Impact of an Average Versus Machine-Specific Dosimetric Leaf Gap on Dose Calculation

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: The newest version of a large commercial treatment planning system (TPS) has introduced a new physical MLC model. We compare the impact of using an averaged dosimetric leaf gap (DLG) value ve...

Evaluation of Dosimetric Variations from Anatomical Changes in Head and Neck Cancer Patients Treated with Intensity Modulated Proton Therapy

Authors: Chia-Lung Chien, Wen C. Hsi, Romy Megahed, Kayla Schneider

Affiliation: Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS), Department of Radiation Oncology, University of Arkansas for Medical Sciences

Abstract Preview: Purpose:
The dosimetric variations induced by inter-fractional anatomical changes in intensity-modulated proton therapy could impact the clinic outcomes for head-and-neck (HN) cancer patients. This...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Evaluation of Treatment Planning Feasibility and Dosimetric Quality of the Reflexionℱ X1 System for Complex Spinal Targets

Authors: Thomas I. Banks, Bin Cai, Andrew R. Godley, Yang Kyun Park, Hao Peng, Rameshwar Prasad, Chenyang Shen, Shunyu Yan, Haozhao Zhang

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, University of Texas Southwestern Medical Center

Abstract Preview: Purpose:
The RefleXionÂź X1 (RefleXion Medical, Inc., Hayward, CA) uniquely integrates KVCT and PET as on-board image guidance for radiotherapy. It has been installed and commissioned for clinical u...

Evaluation of a Commercially Available Solution for Dose Verification Using Daily AI Generated Pseudo-CT from CBCT.

Authors: Chloe DiTusa, Panayiotis Mavroidis, Christopher W. Schneider, Sotirios Stathakis

Affiliation: Louisiana State University, Mary Bird Perkins Cancer Center, University of North Carolina

Abstract Preview: Purpose: To evaluate and compare dose calculation differences between Monaco and AdaptBox by TheraPanacea on AI-generated pseudo-CTs (pCTs) from a CBCT.

Methods: Dose calculations in water phan...

Evaluation of an Offline Adaptive CBCT Planning Workflow for Halcyon with Hypersight

Authors: Michelle Alonso-Basanta, Joshua Bryer, Lei Dong, Barbara Garcia, Elissa Khoudary, Brandon M. Koger, Taoran Li, Michael Salerno, Karen Tang, Boon-Keng Kevin Teo

Affiliation: University of Pennsylvania

Abstract Preview: Purpose: The Varian HyperSight imaging solution features a workflow for planning on CBCT images (CBCTp). This study evaluates the feasibility of CBCTp images in the setting of an offline adaptive plan...

Evaluation of the Accumulated Dose in Combined Radiotherapy for Cervical Carcinoma Using DVH Addition and Deformable Image Registration Based on Optimization of BT Boost Region in EBRT

Authors: Qiu Tang, Yeqiang Tu, Jiahao Wang, Lu Wang

Affiliation: Women's Hospital School of Medicine Zhejiang University, Hangzhou Women's Hospital

Abstract Preview: Purpose: The BT boost regions were previously delineated and optimized during EBRT planning process. The differences of DVH parameters addition (PA), deformable dose summation (DS) with BT boost regio...

Expert Verification of AI-Generated Cardiac Substructures and Dosimetric Differences between Auto-Contoured and Manually Delineated Contours

Authors: Stephen R. Bowen, Richard Cheng, Kylie Kang, Janice Kim, Ana Paula Santos Lima, Dominic A. Maes, Juergen Meyer, Karen Ordovas, Kerry Reding

Affiliation: Department of Radiation Oncology, University of Washington, Department of Radiation Oncology, Fred Hutchinson Cancer Center, University of Washington, Department of Radiology, University of Washington, Division of Cardiology, University of Washington, Department of Biobehavioral Nursing and Health Informatics, School of Nursing, University of Washington

Abstract Preview: Purpose: Artificial intelligence (AI)-based auto-segmentation tools can increase the efficacy and reproducibility of radiotherapy (RT) treatment planning. This study evaluates the quality of AI-genera...

Feasibility Study of Ethos Artificial-Intelligence Online Adaptive Prostate SBRT

Authors: Miguel Albaladejo, Ana Corbalan, Aitor Ortega, Vicente Puchades, David Ramos, Alfredo Serna-Berna, Jonattan Suarez

Affiliation: Hospital General Universitario Santa Lucia

Abstract Preview: Purpose:
Prostate SBRT treatments are frequently delivered using standard VMAT IGRT technique. The aim of this study is to test the feasibility of Ethos Artificial Intelligence (AI) prostate SBRT b...

Feasibility and Dosimetric Impact of Intensity-Modulated Radiotherapy for Cervical Cancer Patients in Nepal: A Retrospective Analysis

Authors: Daniela Branco, John M Bryant, Surendra Bahadur Chand, Pratiksha Shahi, Joseph Weygand

Affiliation: Department of Radiation Oncology and Applied Science, Dartmouth Health, B.P. Koirala Memorial Cancer Hospital, , B.P Koirala Memorial Cancer Hospital, University of California San Diego / California Protons, Department of Radiation Oncology, Moffitt Cancer Center

Abstract Preview: Purpose:
Cervical cancer remains a significant health burden in Nepal, with 2169 new cases and 1313 deaths recorded in 2022. This study evaluates the feasibility of implementing step-and-shoot IMRT...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

From Concept to Clinic: A Phase-Based Approach for Implementing Auto-Segmentation in Radiation Therapy

Authors: Elizabeth L. Covington, Robert T. Dess, Charles S. Mayo, Michelle L. Mierzwa, Dan Polan, Jennifer Shah, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan

Abstract Preview: Purpose: Auto-segmentation improves contour consistency and standardization in radiation therapy but may introduce variations from current practices, potentially impacting treatment outcomes and toxic...

From Supine to Upright: A Geometric Shift in Perspective

Authors: Ben Durkee, Renata Farrell, Carri K. Glide-Hurst, Colin Harari, Alex Singleton Kuo, Chase Ruff, Jordan M. Slagowski, Yuhao Yan

Affiliation: University of Wisconsin, Departments of Human Oncology and Medical Physics, University of Wisconsin-Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: Advances in upright CT and patient positioning system now enables high quality daily CT imaging and treatment delivery in the upright position, providing benefits including reduced internal m...

Fully Automated Review of Prostate Radiotherapy Treatment Plan Quality

Authors: Yasin Abdulkadir, John Charters, Melissa Ghafarian, James M. Lamb, Dishane Chand Luximon, Jack Neylon

Affiliation: Department of Radiation Oncology, University of California, Los Angeles

Abstract Preview: Purpose:
Assessment of radiotherapy treatment quality in large-scale multi-institutional contexts remains an outstanding challenge. Retrospective human review of treatment plans is labor intensive ...

Generalization of the Conformity Index for Multi-Target Radiotherapy Plans

Authors: Jianrong Dai, Jun Dang, Enzhuo Quan, Yong Sang, Jianan Wu

Affiliation: Cancer Hospital Chinese Academy of Medical Sciences, Shenzhen Center, National Cancer Center / National Clinical Research Center for Cancer / Cancer Hospital & Shenzhen Hospital / Chinese Academy of Medical Sciences and Peking Union Medical College, Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Abstract Preview: Purpose: The current conformity index (CI) formula is distorted for radiotherapy plans with multiple, non-enclosing targets. We redefined the volume of reference isodose (VTV) parameter in the CI form...

High-Fidelity Treatment Optimization for Online Adaptive Stereotactic Partial Breast Irradiation: Integrating Dose and Treatment Time Considerations

Authors: Drexell Hunter Boggs, Carlos E. Cardenas, Jingwei Duan, Joseph Harms, Joel A. Pogue, Richard A. Popple, Courtney Bosse Stanley, Dennis N. Stanley, Sean Xavier Sullivan, Natalie N. Viscariello

Affiliation: Washington University in St. Louis, The University of Alabama at Birmingham, University of Alabama at Birmingham

Abstract Preview: Purpose: CBCT-guided online adaptive radiation therapy (OART) with Ethos for stereotactic accelerated partial breast irradiation (APBI) can mitigate inter-fraction variation, leading to dosimetric adv...

Impact of Breathing Trace on Gating Uncertainty

Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing

Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.

Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Improvements from Monte Carlo Simulations over Pencil Beam Algorithms for Normal Tissue Dose Reconstruction in Proton Therapy Patients

Authors: Amy Berrington de Gonzalez, Keith T Griffin, Jae Won Jung, Cari M Kitahara, Choonik Lee, Choonsik Lee, Aimee L McNamara, Matthew Mille, Harald Paganetti, Sergio Morato Rafet, Jan PO Schuemann, Jungwook Shin, Torunn I Yock

Affiliation: University of Michigan, East Carolina University, Massachusetts General Hospital, National Cancer Institute, Division of Cancer Epidemiology and Genetics, National Cancer Institute, Massachusetts General Hospital and Harvard Medical School, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy dose reconstruction enables retrospective epidemiological studies that connect late health effects to the organ-absorbed radiation doses received during treatment. Though clinica...

Inter-Patient Registration Methods for Voxel-Based Analysis in Lung Cancer

Authors: Chloe Min Seo Choi, Joseph O. Deasy, Jue Jiang, Sudharsan Madhavan, Nikhil Mankuzhy, Nishant Nadkarni, Andreas Rimner, Maria Thor, Harini Veeraraghavan, Abraham Wu

Affiliation: University of Freibrug, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Voxel-based analysis (VBA) requires accurate topology-preserving inter-patient deformable image registration (DIR). This study assessed whether guiding a DIR method with geometric priors of t...

Inter-System and Inter-Layer Dlg Variations in Halcyon/Ethos Mlcs: Implications for Dosimetric Matching and User-Adjustable TPS Models

Authors: Evan Barber, Gloria P. Beyer, Matthew J. Daniels, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: TrueNorth Medical Physics, Department of Radiotherapy Physics, Velindre University NHS Trust, Department of Radiation Oncology, Hospital Clinic de Barcelona, Medical Physics Services, LLC

Abstract Preview: Purpose: To quantify inter-system and inter-layer dosimetric leaf gap (DLG) variations in Halcyon/Ethos multileaf collimators (MLCs) using custom sweeping gap tests, and to evaluate implications for c...

Investigating Pitch Factor on Plan Quality in Patients Treated with Hippocampal Avoidance Whole Brain Radiotherapy Using Volo Ultra-Optimized Helical Tomotherapy Plans

Authors: Awens Alphonse, Nebi Demez, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Lauren A. Rigsby, Gagandeep Saini, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study examined the impact of varying the pitch factor in hippocampal-avoidance whole-brain (HP-WB) radiotherapy treatments, utilizing the newly introduced VOLO Ultra optimization for Hel...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

Ir-192 Percentage Depth Ionization of PLA and Ballistic Gelatin Compared to Water

Authors: ChangSeon Kim, Andrew Lukban, Mario Serrano-Sosa, Ching-Ling Teng, Nadia M. Vassell

Affiliation: Northwell, Mount Sinai Beth Israel

Abstract Preview: Purpose:
The flexible nature of ballistic gelatin and 3D printed material such as PLA lend themselves to phantom studies in brachytherapy. While these materials can allow for easy simulation of cat...

Knowledge-Based Planning for Chest Wall with Lymph Nodes Irradiation VMAT

Authors: Nesrin Dogan, Panagiota Galanakou, Robert Kaderka

Affiliation: University of Miami, Sylvester Comprehensive Cancer Center, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose:
To develop knowledge-based treatment planning (KBP) for volumetric modulated arc therapy (VMAT) in chest wall treatments with regional nodal involvement. Given the challenges posed due to ...

Knowledge-Based Planning in Proton Therapy: Validation and Model Size Considerations with Limited Data

Authors: Gregory A Azzam, Michael Butkus, Nesrin Dogan, Robert Kaderka, Nhan Vu, Yihang Xu

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center, University of Miami, Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Knowledge-based planning (KBP) has demonstrated potential for improving planning quality and efficiency. Adoption of KBP in particle therapy has been slow due to limited number of plans to tr...

Monte Carlo Derived Correction Factors for Ion Chambers Used in the Calibration of Gamma Knife Perfexion Model: Impact of Phantom Materials and Chamber Orientation on Dosimetric Accuracy

Authors: Catherine Coolens, Robert K. Heaton, Lalageh Mirzakhanian, Tasnim Rahman, Jan P. Seuntjens

Affiliation: Princess Margaret Cancer Centre & University of Toronto, McGill University, Princess Margaret Cancer Centre, Princess Margaret Hospital, University of Toronto

Abstract Preview: Purpose: Commissioning of a Gamma KnifeÂź (GK) (Elekta, Sweden) unit requires precise dosimetric reference measurements, particularly for small fields. The IAEA TRS-483/AAPM TG-155 code of practice (20...

Multi-Region Multiomic Features Improve Random Forest Toxicity Modeling of Radiation Pneumonitis

Authors: Laurence Edward Court, Alexandra Olivia Leone, Zhongxing Liao, Saurabh Shashikumar Nair, Joshua S. Niedzielski, Ramon Maurilio Salazar, Ting Xu

Affiliation: The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, The University of Texas MD Anderson Cancer Center

Abstract Preview: Purpose: Radiation Pneumonitis (RP) predictive models often rely on clinical and DVH parameters, but multiomic features from CT imaging and 3D dose distributions from various regions could provide add...

Multi-Scale, Multi-Task Framework with Jacobian Descent for Multi-Plan Dose Prediction in Sequential Boost Radiotherapy

Authors: Steve B. Jiang, Mu-Han Lin, Yu-Chen Lin, Austen Matthew Maniscalco, Dan Nguyen, David Sher, Xinran Zhong

Affiliation: Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, UT Dallas

Abstract Preview: Purpose:
Sequential boost radiotherapy (RT) poses a challenge in allocating dose across multiple plans while protecting organs at risk (OARs). Clinicians must decide whether OAR sparing should occu...

Multi-Vendor Validation of a Deep Learning-Based Synthetic CT Generation Model for MR-Only Radiotherapy Planning in the Pelvis

Authors: Gregory Bolard, Rabten Datsang, Sarah Ghandour, Timo Kiljunen, Pauliina Paavilainen, Sami Suilamo, Katlin Tiigi

Affiliation: Turku University Hospital, Virginia Commonwealth University, MVision AI, North Estonia Medical Centre, Docrates Cancer Center, Hopital Riviera-Chablais

Abstract Preview: Purpose: To verify the performance of a vendor-neutral deep learning model for synthetic CT generation from T2-weighted and balanced steady-state MR sequences to support both MR-only simulation and MR...

Multicentric Characterization of Organ-Based Tube Current Modulation in Thoracic and Abdominopelvic Computed Tomography: A Dosimetric and Image Quality Study

Authors: Corentin Desport, Dominique Iacchetti, Nicolas Kien, Ramiro Moreno, Melodie Munier, Séléna Pondard

Affiliation: Fibermetrix, Alara Expertise, Alara Group

Abstract Preview: Purpose: To evaluate the efficiency of organ-based tube current modulation (OBTCM) in thoracic and abdominopelvic Computed Tomography (CT) for different radiology departments and manufacturers. This s...

NTCP Modeling and Dose-Volume Correlations for Rectal Symptoms Following Prostate Cyberknife SBRT.

Authors: Nicholas Joseph Casteloes, Brian T Collins, Sean P Collins, Shiva K. Das, Panayiotis Mavroidis, Michael Repka, Simeng Suy

Affiliation: University of South Florida, University of North Carolina

Abstract Preview: Purpose: To correlate four rectal symptoms with the dose to rectum in patients, who received SBRT with Cyberknife for prostate cancer. Also, to fit those dosimetric and outcome data by using a normal ...

NTCP Modeling of Dose to Bladder and Urethra with Urinary Symptoms Following Prostate Cyberknife SBRT.

Authors: Nicholas Joseph Casteloes, Brian T Collins, Sean P Collins, Shiva K. Das, Panayiotis Mavroidis, Michael Repka, Simeng Suy

Affiliation: University of South Florida, University of North Carolina

Abstract Preview: Purpose: To correlate two urinary symptoms with dose to bladder and urethra in patients who received SBRT with Cyberknife. Also, to use a normal tissue complication (NTCP) model to fit the dosimetric ...

Novel Approach to Improve Treatment Planning Process for Mixed Fractionation Schemes on ZAP-X

Authors: Michael Evan Chaga, Timothy Chen, Darra M. Conti, Shabbar Danish, Jing Feng, Wenzheng Feng, Joseph Hanley, Tingyu Wang

Affiliation: Hackensack Meridian Health, Jersey Shore University Medical Center

Abstract Preview: Purpose: Using mixed fractionation schemes is a common technique in treating CNS lesions. This article describes an innovative plan-and-split approach for more efficient planning on the ZAP-X and thus...

Novel Methods to Select Patients for Functional Avoidance Radiotherapy

Authors: Vikas Aragam, Edward Castillo, Richard Castillo, Yingxuan Chen, Yevgeniy Vinogradskiy, Lydia J. Wilson

Affiliation: Thomas Jefferson University, Emory University, University of Texas at Austin

Abstract Preview: Purpose: 4DCT-based ventilation imaging (4DCT-ventilation) has been innovatively applied in radiotherapy treatment planning to minimize doses to functional portions of the lung, known as functional av...

On Dosimetric Water Equivalency of 3D Printed Materials

Authors: Emily Helen Hayes, Luke Maloney

Affiliation: University of Florida

Abstract Preview: Purpose: To determine the dosimetric water equivalency of polylactic acid (PLA) and commercial 3D printing resin using electron stopping power as a surrogate, for use in radiochromic film calibration ...

On the Sensitivity Evaluation of End-to-End Test in Radiotherapy

Authors: Yussuf A. Abdelal, Sebastien A. Gros, Luke Layman, Anil Sethi

Affiliation: Stritch School of Medicine, Cardinal Bernardin Cancer Center, Loyola University Chicago, Department of Radiation Oncology, Stritch School of Medicine, Loyola University Chicago

Abstract Preview: Purpose:
End-to-end (E2E) test is a vital QA check of the overall radiotherapy process from simulation imaging to treatment delivery. Although clinical passing criteria are available, guidelines on...

Optimizing Quality Assurance CT Frequency and Setup Uncertainty in Brain Proton Therapy Patients for Reduced Normal Tissue Dose

Authors: Rachel B. Ger, Heng Li, Anh Tran

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients undergo quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and utilize robustness scenarios for setup and range uncertainties. For intra...

Optimizing Quality Assurance CT Scan Frequency in Proton Therapy: Reducing Excess Dose While Maintaining Treatment Accuracy

Authors: Curtiland Deville, Rachel B. Ger, Heng Li, Todd R. McNutt

Affiliation: Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Johns Hopkins University

Abstract Preview: Purpose: Proton therapy patients receive quality assurance CT scans (QACTs) during treatment to verify dosimetric accuracy and determine adaptive therapy needs as proton treatments are highly sensitiv...

Phantom-Based Dosimetric Comparison of Multiple CT Metal Artifact Reduction Algorithms for Head-and-Neck Radiotherapy

Authors: Loren Bell, Charles S Cathcart, Brett William Eckroate, Harold Y Hu, Joshua Kilian-Meneghin, Ke Nie, Fredrick Warburton, Zhenyu Xiong, Keying (Karen) Xu, Ning J. Yue, Yin Zhang, Lili Zhou

Affiliation: RWJBarnabas Health, Basis Scottsdale, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: This study compares the dosimetric impact of multiple metal artifact reduction (MAR) algorithms from different CT simulator vendors using an anthropomorphic head phantom for head-and-neck (H/...

Planning Study of Spatially Fractionated Radiotherapy (SFRT) for Treating Recurrent Glioblastoma Multiforme (GBM)

Authors: Hyunuk Jung, Fiona Li, Brian Marples, Michael Milano, Sean M. Tanny, Dandan Zheng, Yuwei Zhou

Affiliation: Department of Radiation Oncology, University of Rochester, University of Rochester Medical Center, University of Rochester

Abstract Preview: Purpose:
Recurrent GBM remains one of the most challenging cancers, with limited treatment options. We investigated potential planning parameters of SFRT, a novel radiotherapy technique that delive...

Post-Implant Dosimetry (PID) between 1D and 2D Cs-131 Seed Models for Post-Op Cavities in Recurrent GBM Patients

Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health

Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Predicting Brain V60% in Linac-Based Single-Isocenter-Multiple-Targets (SIMT) Stereotactic Radiosurgery Using Machine Learning

Authors: John Ginn, Zhuoyun Huang, Yongbok Kim, Ke Lu, Chunhao Wang, Yibo Xie, Zhenyu Yang, Jingtong Zhao

Affiliation: Duke University, Duke Kunshan University

Abstract Preview: Purpose: This study aims to develop and validate a machine learning model for predicting V60%, a critical dosimetric metric in LINAC-based Single-Isocenter-Multiple-Targets (SIMT) stereotactic radiosu...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Retrospective Study Using Avi Planner for Head and Neck Cancer Cases: Our Experience at Nsia-Luth Cancer Center, South - West Nigeria

Authors: Adebayo Abe, Samuel Olaolu Adeneye, Eben Aje, Bidemi I. Akinlade, Inioluwa Damilola Ariyo, Lilian Ekpo, Muhammad Habeebu, Adedayo O. Joseph, Charles S. Mayo, Noah Ndianaobong, Ikechi S Ozoemelam, Margaret Dideolu Taiwo, Godwin Uwagba

Affiliation: University of Michigan, University of Ibadan, University of Lagos, Missouri University of Science and Technology, NSIA-LUTH Cancer Center, University of Lagos, NSIA-LUTH Cancer Centre, NSIA-LUTH Cancer Center

Abstract Preview: Purpose:
Head and neck cancers (HNC) present significant challenges in radiotherapy due to complex anatomy and the proximity to critical organs at risk (OARs). These challenges are compounded in na...

Robust Evaluation of Rotational Uncertainties on Single-Isocenter Multi-Target Stereotactic Radiosurgery Hyperarc Treatment

Authors: Albert Admasu, Kayla Alfonso, Maria de la Luz De Ornelas, Nesrin Dogan, Eric Mellon, Yunze Yang

Affiliation: University of Miami, Department of Radiation Oncology, University of Miami, University of Miami Sylvester Comprehensive Cancer Center

Abstract Preview: Purpose: Rotational uncertainties in single-isocenter multi-target (SIMT) stereotactic radiosurgery (SRS) HyperArc treatments can cause additional target displacement, potentially degrading overall pl...

Robustness Evaluation of Dynamic Arc Proton Therapy: A Comparative Analysis of Small and Large Spot Sizes in Lung and Prostate Cancer Planning

Authors: Awens Alphonse, Nebi Demez, Michael Kasper, Noufal Manthala Padannayil, Shyam Pokharel, Suresh Rana, Hina Saeed, Gagandeep Saini, Nishan Shrestha, Somol Sunny

Affiliation: Lynn Cancer Institute, Boca Raton Regional Hospital, Baptist Health South Florida

Abstract Preview: Purpose: This study evaluates the robustness of DynamicARC proton therapy plans for lung and prostate cancer, comparing small spot size (SS) and large spot size (LS) plans under nominal and worst-case...

S Values for a Monkey Computational Model for Internally Distributed Radiation Sources

Authors: Jae Won Jung, Daniel Lee

Affiliation: Thomas S. Wootton High School, East Carolina University Brody School of Medicine

Abstract Preview: Purpose: Monkeys have played a key role in enhancing our understanding of the behavior of radioactive materials within living organisms in the field of nuclear medicine. However, detailed dosimetric d...

Significantly Limiting Posterior Gantry Angles in Prostate VMAT Optimization: A Dosimetric Assessment of Plan Quality

Authors: Yijian Cao, Sean T Grace, Marissa Joyce Vaccarelli

Affiliation: Northwell

Abstract Preview: Purpose:
This study investigates the dosimetric efficacy of significantly limiting gantry angles in prostate radiation therapy to as a promising strategy to maintain plan quality while enhancing ma...

Temporal Drift in Ir-192 Source Strength Measurements: A Braphyqs Multi-Center Analysis

Authors: Åsa K. Carlsson Tedgren, Taran Hellebust, Antonio Herreros, Jacob Johansen, Christian Kirisits, Panagiotis Papagiannis, Mark J. Rivard, Frank-Andre Siebert, Frank Verhaegen, Javier Vijande, Jan Wiersma, Marisol de Brabandere, Ruud van Leeuwen

Affiliation: UKSH, Campus Kiel, Klinik fĂŒr Strahlentherapie (Radioonkologie), Department of Oncology, The Norwegian Radium Hospital, Oslo University Hospital, Radiation Physics, Department of Medicine and Health (IMH), Linköping University, Radiation Oncology Department, Hospital ClĂ­nic-Universitat de Barcelona, IDIBAPS, IFIC-UV, Radiation Oncology, Amsterdam UMC location University of Amsterdam, Department of Radiation Oncology, Radboud University Medical Center, Department of Oncology, Aarhus University Hospital, University Hospital Gasthuisberg, Dept. of Radiation Oncology, Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, Department of Radiation Oncology (MAASTRO), GROW – School for Oncology and Reproduction, Maastricht University Medical Centre+, Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna, Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: This study, which was carried out by the GEC-ESTRO BRAPHYQS working group, reports the increasing divergence between clinical reference air kerma rate (RAKR) measurements and vendor-provided ...

The Impact of Implant Position and Different Radiotherapy Techniques on Dosimetry in Post-Mastectomy Breast Reconstruction for Breast Cancer

Authors: Xiu tong Lin

Affiliation: Department of Radiation physics and technology, Shandong Second Provincial General Hospital

Abstract Preview: Purpose: To compare the dosimetric differences between the photon and proton plans and between the different target according to the placement of the implants for patients undergoing radiotherapy afte...

Towards AI Decision-Support for Online Adaptive Radiotherapy (oART): A Preliminary Study on CBCT-Guided Post-Prostatectomy Oart

Authors: Michael Cummings, Olga M. Dona Lemus, Hana Mekdash, Tyler Moran, Alexander R Podgorsak, Sean M. Tanny, Matthew J. Webster, Lexiang Yang, Dandan Zheng, Yuwei Zhou, Xiaofeng Zhu

Affiliation: Department of Radiation Oncology, University of Rochester, University of Miami, Inova Schar Cancer Institute, University of Rochester

Abstract Preview: Purpose: oART is revolutionizing radiotherapy by allowing treatment plans to be adjusted based on daily imaging, improving targeting precision and potentially enhancing patient outcomes. However, its ...

Towards In Vivo Dosimetry for Adaptive MR-Guided Radiation Therapy: Initial Report on a Prototype Injectable Dosimeter

Authors: Daniel Ball, Alex Dresner, Geoffrey S. Ibbott, Leonard H. Kim, Christopher Tyerech, SebastiĂĄn Vega

Affiliation: MD Anderson Cancer Center at Cooper, Cooper Medical School of Rowan University, The American Board of Radiology, Department of Radiation Oncology, University of Pennsylvania, Rowan University, Philips Healthcare MR Oncology

Abstract Preview: Purpose:
In vivo dosimetry is valuable to radiation therapy for its ability to report the actual dose received by patients but is currently limited to surface and intracavitary measurements, leavin...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Treatment Plan Comparisons of Head and Neck Cancers on Varian Ethos/Halcyon and Truebeam Linac

Authors: Yunfeng Cui, Joseph P. Kowalski, Qiuwen Wu, Yibo Xie

Affiliation: Duke University, Duke University Medical Center

Abstract Preview: Purpose: A Varian Ethos/Halcyon linac was recently commissioned in our clinic and was used to treat head and neck cancer patients. The purpose of this study is to compare treatment plan quality and de...

When Protons Are Unavailable: Study of High Quality Knowledge-Based Planning Models for the Treatment of Unilateral Head and Neck Patients

Authors: Kenny Guida, Daniel Johnson, Wesley Tucker

Affiliation: University of Kansas Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Intensity modulated proton therapy (IMPT) has emerged as a standard of care for unilateral head and neck (HN) cancers due to superior OAR sparing. With the increase of proton centers national...