Search Submissions 🔎

Results for "dosimetry calculation": 55 found

A Comparative Analysis of Hand Calculations and Macro Monte Carlo Simulations for Electron Beam Dosimetry

Authors: Mohamed Eldib, Adam Mahl, Moyed Miften, Rachel Petragallo, Kelly L. Stuhr

Affiliation: University of Colorado - Anschutz Medical Campus, University of Colorado School of Medicine, University of Colorado Denver, Department of Radiation Oncology, University of Colorado

Abstract Preview: Purpose: To compare electron beam dose calculations performed manually with those computed using the Macro Monte Carlo simulation for standard fields on both phantom and patient setups, with the aim o...

Addressing Radionuclide Decay Complexities in Targeted Alpha Therapy: A Computational Approach.

Authors: Denis Bergeron, Ryan P Fitzgerald, Ravneet Kaur, Rao Khan

Affiliation: John Hopkins University, NIST Radiation Physics Division, Howard University, National Institute of Standards and Technology

Abstract Preview: Purpose: There is growing interest in short-lived alpha-emitting radionuclides for cancer therapy due to their ability to selectively target and destroy cancer cells while sparing healthy tissue. Howe...

An End-to-End Test for Adaptive Radiotherapy with Varian Hypersight CBCT Imaging System Using Radiochromic Film in a Rando Pelvis Phantom

Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma

Affiliation: Northwell, Hofstra University Medical Physics Program

Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...

An Integrated Robust Inverse Planning Based on AI-Built Dose Kernel Library for Preclinical Radio-Neuromodulation Using Focused Kv X-Rays

Authors: Wenbo Gu, Chenhui Qiu, Ke Sheng, Liyan Sun, Weiyuan Sun, Lei Xing

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiology, Stanford University, University of Pennsylvania, Department of Radiation Oncology, University of California, San Francisco, Department of Radiation Oncology, Stanford University,

Abstract Preview: Purpose:
The small animal radio-neuromodulation platform developed in our previous work utilized focused kV x-ray beams rotating and translating in predefined trajectories to irradiate small, mm si...

An Ultra-High Parallel Performance (UHPP) Framework for Highly Complex Radiotherapy Planning

Authors: Lu Jiang, Shusen Jing, Qihui Lyu, Dan Ruan, Ke Sheng, Qifan Xu

Affiliation: Department of Radiation Oncology, University of California, Los Angeles, University of California San Francisco, Department of Radiation Oncology, University of California at San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose: In radiotherapy, the conformity and compactness of dose distribution are vital to patient outcomes. The introduction of highly complex planning, such as 4π radiotherapy, has provided a system...

Approaches to Mitigate Sources of Error in the Dosimetry Calculation Chain

Authors: Julia Brosch-Lenz

Affiliation: Institute of Nuclear Medicine

Abstract Preview: N/A...

Assessing Long-Term Stability of Parylene-Coated, 3D-Printed Plastic Vessels for Water Calorimetry-Based Radiation Dosimetry

Authors: Philip Cutter, Mark D'Souza, Arman Sarfehnia

Affiliation: Toronto Metropolitan University, Sunnybrook Health Sciences Centre, Sunnybrook Health Science Center

Abstract Preview: Purpose: Water calorimetry (WC) serves as an important standard for measuring absorbed dose to water, an essential metric in radiation therapy. WC directly and absolutely quantifies energy deposition ...

Backscattering of Compton Cameras: A Monte Carlo Simulation Approach

Authors: Jorge Naoki Dominguez Kondo, Qihui Lyu

Affiliation: University of California San Francisco, Department of Radiation Oncology, University of California, San Francisco

Abstract Preview: Purpose:
Targeted alpha therapy (TAT) has emerged as a highly potent therapeutic method in oncology, but its development is limited by the lack of imaging methods to quantify its dosimetry. Convent...

Brachyplancheck: An Independent Monte Carlo Dose Calculation Tool for Brachytherapy Using Egs_Brachy

Authors: Amy Tien Yee Chang, Chi Wai Cheung, Tin Lok Chiu, Chen-Yu Huang, Chi Wa Kong, Pei-Xiong Li, Pak Hang Nam, Bin Yang, Siu Ki Yu

Affiliation: Comprehensive Oncology Centre, Hong Kong Sanatorium and Hospital, Medical Physics Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: This study introduces BrachyPlanCheck, an independent Monte Carlo (MC)-based dose calculation tool for 192Ir brachytherapy retrospective study or algorithm commissioning.
Methods: BrachyPl...

Characterizing and Modeling Higher-Order Motions of Collimator Subsystem on a 60RPM Gantry Linac for Improved Small Target Dosimetry

Authors: David J. Carlson, Yiu-Hsin Chang, Huixiao Chen, Zhe (Jay) Chen, Blake Gaderlund, Ray Yang

Affiliation: RefleXion Medical, Department of Therapeutic Radiology, Yale University School of Medicine

Abstract Preview: Purpose: To address the root cause of dosimetric discrepancy for small central targets (<2cm) especially sensitive to geometric alignment of beamlets, by modeling higher-order oscillations of the coll...

Commissioning Radcalc v7.3 with a Collapsed Cone Calculation Algorithm for 6X FFF and 10X FFF Energies

Authors: Maria Jose Almada, Carlos Bohorquez, Maximiliano Musso, Rosa Petit, Carlos Daniel Venencia, Lucy D. Wolfsberger

Affiliation: LAP, Instituto Zunino - Fundacion Marie Curie

Abstract Preview: Purpose:
PSQA is crucial in maintaining patient safety, typically depending on dosimetric measurements. However, advancements in computational technology have highlighted the growing significance o...

Commissioning of Elekta Leipzig and Valencia Skin Applicators

Authors: Hamid Aghdam, DJ Chen, Heather Chen, Sharad Goyal, Yonas Solomon Mekuria, Martin Ojong-Ntui, Yuan James Rao

Affiliation: The George Washington University, The George Washington University Cancer Center

Abstract Preview: Purpose: Elekta Leipzig and Valencia Skin applicators are designed to treat skin lesions. The applicators limit the irradiation to the required treatment area using a densimet shielding. Valencia uses...

Commissioning of Varian HDR Surface Applicators Using High-Resolution Diode Array and Film Dosimetry

Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza

Affiliation: Vanderbilt University Medical Center

Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...

Computed Tomography Organ Dose Library Derived from Newly Developed Newborn-Infant-Toddler Computational Phantoms

Authors: Jared Baggett, Wesley E. Bolch, Lukas M. Carter, Robert Joseph Dawson, Laura Dinwiddie, Adam Leon Kesner, Cameron B. Kofler, Juan Camilo Ocampo Ramos, Yitian Wang, Stefan Wehmeier

Affiliation: University of Chicago, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, University of Florida, MD Anderson

Abstract Preview: Purpose: To develop a slice-specific computed tomography (CT) organ dose library using Monte Carlo radiation transport simulations on a newly created set of newborn, infant, and toddler computational ...

Cumulative Doses in Radiotherapy Treatment of Lymphoma Patients

Authors: Klaus Bacher, Tom Boterberg, Jeff Rutten, Barbara Vanderstraeten, Gwenny Verfaillie, Sarah Waelkens

Affiliation: Ghent University, Ghent University Hospital

Abstract Preview: Purpose: Lymphoma cancer patients frequently receive ionizing radiation during their treatment trajectory, including diagnostic CT, planning CT (pCT), recurrent CBCTs, radiotherapy (out-of-field) dose...

Determination of HU Override for Small Metal Implants in Proton Therapy

Authors: Matthew Stephen Andriotty, Taoran Cui, Harold Y Hu, Ke Nie, Tan Phan, Xiao Wang, Ning J. Yue, Chengzhu Zhang

Affiliation: Rutgers Cancer Institute of New Jersey, Basis Scottsdale

Abstract Preview: Purpose: Metallic implants are often non-isocentric, and their exact volumes/orientations/shapes are difficult to capture and contour accurately on CT images even if that information is known beforeha...

Determining Optimal Delivery Pattern for Reference Dosimetry in Pencil Beam Scanning Proton Therapy

Authors: Clifford Ghee Ann Chua, Calvin Wei Yang Koh, Kah Seng Lew, Zubin Master, Sung Yong Park, Hong Qi Tan, Andrew Wibawa

Affiliation: National Cancer Centre Singapore

Abstract Preview: Purpose: To investigate the impact of spot position deviation on reference dosimetry measurements using different delivery patterns and to determine the optimal delivery pattern for reference dosimetr...

Dosimetric Evaluation of Comprehensive Motion Management in 1.5T MR-Linac for Real-Time Gated Radiotherapy

Authors: Kin Yin Cheung, Chen-Yu Huang, Chi Wah Kong, Ka Ki Lau, Pei-Xiong Li, Pak Hang Nam, Mei Yan Tse, Jierong Wang, Bin Yang, Siu Ki Yu, Jing Yuan, Chi To Yung, Shang Peng Felix Yung

Affiliation: Medical Physics Department, Hong Kong Sanatorium and Hospital, Research Department, Hong Kong Sanatorium and Hospital

Abstract Preview: Purpose: Intrafraction motion management remains a major challenge in magnetic resonance-guided radiotherapy (MRgRT). The recent clinical release of an active motion management system aims to enhance ...

Dosimetric Uncertainties Associated with Photon Small Field Dosimetry

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To evaluate quantitatively the dosimetric uncertainties associated with dose calculation and measurement of small photon fields used in stereotactic photon therapy.
Methods: The output fac...

Dosimetry Impact of Overlapping Reconstruction of CT Simulation in Stereotactic Radiosurgery Planning

Authors: Matthew Stephen Andriotty, Chi Ma, Xiao Wang, Keying (Karen) Xu, Suhong Yu, Ning J. Yue, Yin Zhang

Affiliation: Brigham and Women's Hospital, Rutgers Cancer Institute of New Jersey

Abstract Preview: Purpose: To evaluate the effects of overlapping CT reconstruction on dosimetry calculation for LINAC-based SRS patients simulated on CT simulators from three different vendors.
Methods: CT simulati...

Dosimetry of Gamma Knife Stereotactic Radiosurgery Tissue Heterogeneity Corrections for Pituitary Adenomas

Authors: James M. Brindle, Gene A. Cardarelli, Alexis Leuci, Mark J. Rivard

Affiliation: Warren Alpert Medical School of Brown University

Abstract Preview: Purpose: Leskell GammaPlan (LGP) is equipped with the Collapsed Cone Convolution (CCC) and TMR10 calculation algorithms. Use of the CCC algorithm accounts for tissue heterogeneities not considered in ...

Evaluation of Film and 3D Printed Patient-Specific Phantom for Minibeam Radiation Therapy (MBRT) Dosimetry

Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus

Affiliation: Mayo Clinic - Rochester, Mayo Clinic

Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

Feasibility of Efficient Offline Adaptive Replanning with Hypersight High-Performance Cone-Beam CT on Truebeam for Pelvis RT

Authors: Jochen Cammin, Shifeng Chen, Arun Gopal, Kai Huang, Jason K Molitoris, Amit Sawant, Kai Wang

Affiliation: University of Maryland, Department of Radiation Oncology, University of Maryland School of Medicine, Maryland University Baltimore, Department of Radiation Oncology, University of Maryland Medical Center

Abstract Preview: Purpose: The HyperSight CBCT optional feature on Varian TrueBeam linacs offers a larger field-of-view, improved Hounsfield units (HU) accuracy, and overall improved image quality, including metal arti...

Impact of Source-to-Imager Distance on Patient-Specific Quality Assurance Using Epid

Authors: Hajee Reyaz Ali Sahib, Sangeeta Hazarika, Muthukumaran Manavalan, Jaswin Raj, Daya Nand Sharma, Seema Sharma, Subramani Vellaiyan

Affiliation: AIIMS NCI Jhajjar, PTW North America Corporation, All India Institute of Medical Sciences

Abstract Preview: Purpose:
Purpose is to investigate the effect of extended source-to-imager distances (SID) on the resolution of VMAT patient-specific quality assurance (PSQA) in portal dosimetry (PD).
Methods:<...

In Vivo Dosimetry for Cied Management – Is It Really Needed?

Authors: Anthony J. Doemer, Aharon Feldman, Stephen J. Gardner, Brett M. Miller, Benjamin Movsas, Farzan Siddiqui, Chadd Smith, Kundan S Thind, Kyle Verdecchia

Affiliation: Henry Ford Health

Abstract Preview: Purpose: To evaluate the efficacy of calculation-only approach for CIED risk-level assessment.
Methods: A total of 86 patients were included in this retrospective analysis. For each patient, in viv...

Innovative Workflow for Enhanced in-Vivo Dosimetry Using Gafchromic Film

Authors: Salim Balik, Nguyen Phuong Dang, Hualin Zhang

Affiliation: Radiation Oncology, Keck School of Medicine of USC

Abstract Preview: Purpose: An accurate and convenient monitoring of radiation dose delivery during treatment is essential for ensuring patient safety and treatment efficacy. This project aims to develop innovative algo...

Intra-Organ Blood Vessel Mapping in Mice for Improved Pre-Clinical Radiation Dosimetry

Authors: Daylin Barroso, Chris Beekman, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Robert Joseph Dawson, Walter Murfee, Harald Paganetti, Andrew Robert Sforza, Julia D. Withrow

Affiliation: Massachusetts General Hospital - Harvard Medical School, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: To develop methods for quantifying the interaction of radiation with blood in the mouse whole body (MOBY) phantom for dosimetric applications. The most important of these are modeling the dis...

Mesh-Based Multiregion Model of Adult Human Kidneys for Dosimetric Evaluation of Radiopharmaceutical Therapy

Authors: John P. Aris, Wesley E. Bolch, Chansoo Choi, Carlos G. Colon-Ortiz, Robert Joseph Dawson, Abdul-Vehab Dozic, Amy M. Geyer, Harald Paganetti, Shreya P. Pathak, Julia D. Withrow

Affiliation: St. Luke's Health System, Massachusetts General Hospital, University of Florida

Abstract Preview: Purpose: The goal of this study was to enhance the accuracy of renal dosimetry in radiopharmaceutical therapy (RPT) by developing a more detailed and precise kidney model. In RPT, accurate dose estima...

Modeling Alpha-Particle Dose from Diffusing Alpha-Emitters Radiation Therapy in Tissue with Inhomogeneous Diffusion

Authors: Lior Arazi, Gil'ad N. Cohen, Antonio L. Damato, Irene P. Zhang

Affiliation: Unit of Nuclear Engineering, Faculty of Engineering Sciences, Ben-Gurion University of the Negev, NYU Grossman School of Medicine, Memorial Sloan Kettering Cancer Center

Abstract Preview: Purpose: Diffusing alpha-emitters Radiation Therapy (“Alpha DaRT”) is a promising new radiation therapy modality for treating bulky tumors. The dose delivered by Alpha-DaRT sources is dependent on the...

Normal Tissue Dosimetry during Intra-Cavitary HDR Brachytherapy

Authors: Palanisamy Karunanithi, Karthikeyan Perumal, Siva Subramanian Vadivel

Affiliation: Dr. Kamakshi Memorial Hospital

Abstract Preview: Purpose:
Recent advancements in high dose-rate (HDR) brachytherapy include the image guidance, new applicators, and dose calculation algorithms. Brachytherapy has steep dose gradient, hence relativ...

Novel Use of 3D Printing for Pre-Operative Dose Estimation in the First Case of Gammatile Spine Implantation

Authors: Ali Al Asadi, Amanda Lynn DiCarlo, Anthony J. Doemer, Jessie Y. Huang, Ian Y Lee, Alexandra Moceri, Adam Robin, Lisa Scarpace, Mira Shah, Salim Siddiqui, Kundan S Thind

Affiliation: Henry Ford Innovations, Henry Ford Health

Abstract Preview: Purpose: For a patient who had two previous courses of external beam therapy for rectosigmoid adenocarcinoma and presented with painful, recurrent disease in the sacrum, this study describes the first...

Optimizing Dosimetry in Rpt Clinics: Tackling Initial Hurdles and Ensuring Image Accuracy.

Authors: Siju C. George, Alonso N. Gutierrez, Vivek Mishra, Ranjini P. Tolakanahalli

Affiliation: Miami Cancer Institute, Baptist Health South Florida, Miami Cancer Institute

Abstract Preview: Purpose: This presentation focuses on optimizing dosimetry in RPT clinics by tackling initial setup challenges and ensuring the accuracy of SPECT/CT imaging for dosimetry. It will address the qualific...

Parameterized Dosimetric Models of the Lumbar Vertebrae for Patient-Informed Active Marrow Dosimetry in Radiopharmaceutical Therapy

Authors: Wesley E. Bolch, Chansoo Choi, Robert Joseph Dawson, Michael Lassmann, Maikol Salas-Ramirez, Bangho Shin, Johannes Tran-Gia, Yitian Wang

Affiliation: Department of Nuclear Medicine, University Hospital Würzburg, University of Florida

Abstract Preview: Purpose: Conduct a parameterized library of mesh-type skeletal models across the lumbar vertebrae. In radiopharmaceutical dosimetry, the hematopoietic active bone marrow is typically a dose-limiting n...

Performance Evaluation of End-of-Life Epid Panel Utilizing Automated Quality Assurance Test Suite

Authors: Michael Paul Barnes, Lana C. Critchfield, John J. DeMarco, Ellie Durussel, Nilendu Gupta, James Irrer, Peyton Jensen, Grace Gwe-Ya Kim, Cory S. Knill, Seng Boh Gary Lim, Justin K. Mikell, Jean M. Moran, Seyyedeh Azar Oliaei Motlagh, Mario Perez, Michael Pillainayagam, Claire Zhang

Affiliation: University of Michigan, Department of Radiation Oncology, University of Michigan, Department of Medical Physics, Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Washington University School of Medicine in St. Louis, University of California San Diego, Royal North Shore Hospital, Calvary Mater Hospital Newcastle, Cedars-Sinai Medical Center

Abstract Preview: Purpose: EPIDs are widely used in linac QA due to their efficiency and accuracy. As EPIDs age, performance degradation may occur, potentially compromising reliability of EPID-based automated QA result...

Post-Implant Dosimetry (PID) between 1D and 2D Cs-131 Seed Models for Post-Op Cavities in Recurrent GBM Patients

Authors: Cindy Pham, Anurag Sharma, John Starner, Ching-Ling Teng, Michael A. Trager, Gabriella Wernicke

Affiliation: Northwell, Northwell Health, Radiation Medicine, Northwell Health

Abstract Preview: Purpose: Precisely identifying orientation of implanted seeds on post-implant CTs is challenging. This research addresses the dosimetric uncertainties stemming from uncertainties in identifying seed o...

Preclinical Dosimetric Evaluation for Small Animal Study to Investigate Normal Tissue-Sparing Effects in the Electron Ultra-High Dose-Rate (FLASH) Environment

Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou

Affiliation: University of Nebraska Medical Center

Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...

Quantifying the Impact of Tissue Inhomogeneities on Calculated Dosimetry within LDR Brachytherapy

Authors: Fatemeh Akbari, Deidre Batchelar, Luc Beaulieu, Nathan E. Becker, Juanita Crook, Dakota Mckeown, Matthew Jonathan Muscat, Rowan M. Thomson

Affiliation: Département de physique, de génie physique et d'optique, Université Laval, BC Cancer Agency, UBC, Carleton University, BC Cancer - Kelowna, BC Cancer

Abstract Preview: Purpose:
To study the effects of inter-seed attenuation and tissue inhomogeneities on dose-volume metrics of critical structures in prostate low-dose-rate (LDR) permanent seed implant brachytherapy...

Refining the in-House Modified COMS Eye Plaque Workflow

Authors: Vishruta A. Dumane, Andrew Lukban, Kiran Pant, Charlotte Elizabeth Read, Ren-Dih Sheu, Nadia M. Vassell

Affiliation: Icahn School of Medicine at Mount Sinai, Mount Sinai Beth Israel, Icahn School of Medicine at Mount Sinai, Department of Radiation Oncology

Abstract Preview: Purpose: This work introduces a refined in-house modified COMS eye plaque management system to streamline processes, reduce redundancies, and enhance usability.
Methods: A web-based application wit...

Retrospective Evaluation of Combined Photon SBRT and Radium-223 SPECT Based Radiopharmaceutical Therapy Tumor Dosimetry in Clinical Trial Patient Cases

Authors: David P. Adam, Allison Cartee, Eric C. Frey, Michael Ghaly, Bin He, Robert Francois Hobbs, Natalie Rose Kania, Ana Kiess, Ian Marsh, Bonnie N. C. President, Steven Rowe, George Sgouros, Phuoc Tran, Hao Wang

Affiliation: Johns Hopkins University, Radiopharmaceutical Imaging and Dosimetry, LLC (Rapid), 2The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Johns Hopkins Medical Institute, Department of Radiation Oncology, University of Maryland School of Medicine, Department of Oncology, Johns Hopkins University, School of Medicine, Department of Radiology, University of North Carolina, Chapel Hill

Abstract Preview: Purpose: Advanced treatment paradigms combining SPECT/CT imageable, alpha emitting, radiopharmaceutical therapy (RPT) and stereotactic body radiotherapy (SBRT) can provide the potential of dose escala...

Retrospective Postimplant Dosimetry: Comparison of Line and Point Source for 131cs Low Dose Rate Intracranial Implant Brachytherapy

Authors: Tirthraj Adhikari, Timothy J Allen, Abdullah A. Alshreef, Clara Ferreira

Affiliation: Medical School Department of Radiation Oncology University of Minnesota, University of Minnesota, Loma Linda University Medical Center

Abstract Preview: Purpose: GammaTile Brachytherapy with 131Cs is an effective treatment for glioblastomas, offering local control with minimal radiation necrosis. While the line source model is preferred for dose distr...

Small Fields Output Factor Measurements in 1.5 MR-Linac

Authors: Thomas I. Banks, Tsuicheng D. Chiu, Viktor M. Iakovenko, Christopher Kabat, Chang-Shiun Lin, Mu-Han Lin, Arnold Pompos

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab & Department of Radiation Oncology, UT Southwestern Medical Center, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX

Abstract Preview: Purpose: The superior soft-tissue contrast provided by MR imaging offers favorable conditions for the effective application of stereotactic body radiation therapy (SBRT). Accurate small field dosimetr...

Sources of Error and Their Propagation in the Dosimetry Calculation Chain

Authors: Carlos Uribe

Affiliation: BC Cancer Research

Abstract Preview: N/A...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...

Standardized Immobilization and Setup Procedure Improves Accuracy of Multi-Time Point SPECT/CT Image Registration for Radiopharmaceutical Therapy (RPT) Dosimetry

Authors: Bryan Bednarz, Laura Bennett, Abby E. Besemer, Tyler J Bradshaw, Steve Y Cho, John M. Floberg, Joseph Grudzinski, Elissa Khoudary, Michael J. Lawless

Affiliation: Department of Radiology, University of Wisconsin, University of Wisconsin-Madison Department of Medical Physics, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Voximetry, Inc, University of Pennsylvania, Department of Radiology, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin-Madison

Abstract Preview: Purpose: To assess the impact of using a standardized immobilization setup for multi-time-point SPECT/CT imaging on radiopharmaceutical therapy (RPT) dosimetry image registration.

Methods: Ten ...

Streamlined Stereotactic Radiosurgery (SRS) Commissioning Experience with a 6FFF Beam for an Elekta Versa: A Clinical Overview for Increased Precision.

Authors: Asma Amjad, Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong

Affiliation: Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose: Accurate and precise linac-based SRS commissioning can be very challenging. Thus, it is important to increase the confidence in the measurement at each step prior to end-to-end testing. The p...

Teach What You See: Incorporating Theranostics Curriculum into Medical Physics Resident Education

Authors: Isaac J. Bailey, Lindsay S. DeWeese, Anna M. Mench, Celeste Winters

Affiliation: Oregon Health & Science University, Department of Diagnostic Radiology, Oregon Health & Science University

Abstract Preview: Purpose: The emergence and recent FDA approval of several new radiopharmaceutical therapies have increased demand for physicists to provide specialized support. However, these topics are not yet inclu...

Total Body Irradiation Using Field-in-Field Treatment Planning Techniques

Authors: Kazi Towmim Afrin, Imad M. Ali, Jordan West

Affiliation: University of Oklahoma Health Sciences Center, University of Oklahoma

Abstract Preview: Purpose: To simulate total-body-irradiation (TBI) with field-in-field treatment planning techniques and test portal dosimetry for dose verification and quality assurance.
Methods: CT images of full...

Treatment Machine Matching for ELM in Eclipse v18.0 By Adjusting Physical Leaf Gap

Authors: Quyen Duong, Si Young Jang, Soyoung Lee, Samuel Ming Ho Luk

Affiliation: Boston University, Department of Radiation Oncology, University of Vermont Medical Center, Boston Medical Center

Abstract Preview: Purpose: To investigate the clinical impact of physical MLC gaps changes with Millennium 120 MLC on Enhanced Leaf Modeling (ELM) and patient plans, and to establish a new MLC model in Eclipse v18.0 on...

Uncertainty in Contralateral Breast Dose Reconstruction for Breast Cancer Radiotherapy Patients in the United States between 1990 and 2012

Authors: Amy Berrington de Gonzalez, David Borrego, Rochelle Curtis, Gretchen L Gierach, Jae Won Jung, Choonik Lee, Choonsik Lee, Matthew Mille, Lene Veiga, Jacqueline Vo

Affiliation: University of Michigan, East Carolina University, Radiation Protection Division, Office of Radiation and Indoor Air, U.S. Environmental Protection Agency, National Cancer Institute, Institute of Cancer Research

Abstract Preview: Purpose: Radiotherapy is vital for treating breast cancer, but its long-term health effects remain a concern. Accurate dose reconstruction is crucial for evaluating risks in retrospective epidemiologi...

Using a-Si 1200 Epid Portal Dosimetry for VMAT Commissioning

Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed

Affiliation: Bay Pines VA Medical Center

Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...

Utilizing All Acquired Images from Fluoroscopically-Guided Interventions: Test Application with Event-By-Event Patient Dosimetry Calculations

Authors: Sagine Berry-Tony, Lasya Daggumati, James R Duncan, Melak Senay, Allan Thomas

Affiliation: University of Missouri-Kansas City School of Medicine, Mallinckrodt Institute of Radiology, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: Most acquired images in FGIs are not permanently archived. In the context of modern computational prowess, novel improvements to FGI practice likely sit just under the surface of large-scale ...

Validation of Radiopharmaceutical Therapy (RPT) Dose Calculation Platforms from Absolute Absorbed Dose Measurement of 225ac

Authors: Bryan Bednarz, Larry A. DeWerd, Sean Jollota, Ahtesham Ullah Khan, Ohyun Kwon, Jeff Radtke

Affiliation: Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison

Abstract Preview: Purpose: The accurate quantification of absorbed dose is essential for alpha-emitting radionuclides used in radiopharmaceutical therapy (RPT). This study presents the first direct comparison of physic...

Validation of SRS Mapcheck for Patient-Specific Quality Assurance of Cyberknife

Authors: Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, Tae Ho Kim, Sangmin Lee

Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine

Abstract Preview: Purpose: The CyberKnife system, designed for stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT), considers SRS MapCHECK an effective tool for patient-specific QA (PSQA). This wo...

Voxel-Based Micro-Yucatan Minipig Phantoms for Use in Internal Dosimetry

Authors: John P. Aris, Wesley E. Bolch, Natalia Estefania Carrasco-Rojas, Ann M. Chan, Chansoo Choi, Aitor Gallastegui Menoyo, Rowan James Milner, Bangho Shin, Maria M. Von Chamier

Affiliation: University of Florida

Abstract Preview: Purpose: In preclinical studies, minipigs serve as valuable experimental models for predicting absorbed doses due to their anatomical and physiological similarities to humans. However, minipig computa...