Search Submissions 🔎

Results for "dynamic collimator": 19 found

A Novel Semi-Analytic Approach for Dose Calculation in Proton Minibeam Radiotherapy

Authors: Hao Gao, Wangyao Li, Yuting Lin, Chao Wang, Wei Wu

Affiliation: Institute of Modern Physics, Chinese Academy of Sciences, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Proton minibeam radiation therapy (pMBRT) delivers a unique peak-and-valley dose pattern using collimators with narrow slits, offering improved normal tissue sparing compared to conventional ...

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

Characterizing a VMAT Optimization Algorithm with Integrated Static-Angle Modulated Ports for Esophageal Cancer Treatment

Authors: Lei Dong, Yin Gao, Taoran Li, Michael Salerno, Boon-Keng Kevin Teo, Melissa Vila

Affiliation: Department of Radiation Oncology, University of Pennsylvania, University of Pennsylvania

Abstract Preview: Purpose: A novel solution, RapidArc Dynamic-RAD (Varian Medical Systems, Palo Alto, USA) has been implemented to integrate VMAT with modulation of IMRT-like static-angle ports, including use of a dyna...

Comparative Analysis of Four Measurement Methods for Multileaf Collimator Backlash

Authors: Niko Ahjoniemi, Antti Kulmala, Katja Peltola

Affiliation: Clinical Research Institute HUS, Helsinki University Hospital

Abstract Preview: Purpose: To determine the backlash of a multileaf collimator (MLC) using four measurement methods: motor encoder (primary readout), linear potentiometer (secondary readout), amorphous silicon panel (p...

Comprehensive Commissioning of an O-Ring-Shaped Image-Guided Radiotherapy System with a Gimbal-Mounted Linear Accelerator

Authors: Tetsuo Fukuda, Hideaki Hirashima, Kohei Kawata, Yukako Kishigami, Takashi Mizowaki, Mitsuhiro Nakamura, Yohei Sawada, Maika Urago

Affiliation: Kyoto University, kyotoUnivercity, Hitachi high-tech, Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University

Abstract Preview: Purpose: To present the comprehensive commissioning results of the O-ring shaped linac, OXRAY.
Materials and Methods: OXRAY enables a novel three-dimensional unicursal noncoplanar irradiation metho...

Development of an Ultrafast MR Technique to Detect Linac Radiation Pulses for Biological Imaging on a Clinical 0.35T MR-Linac

Authors: Pierre Gardair, Johnathan E Leeman, Claire Keun Sun Park, Atchar Sudhyadhom

Affiliation: Brigham and Women’s Hospital, Dana Farber Cancer Institute, Harvard Medical School, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School,, Brigham and Women’s Hospital and Dana Farber Cancer Institute, Harvard Medical School, Harvard Medical School

Abstract Preview: Purpose: Dose is a poor surrogate for radiobiological damage but no in vivo technology exists to directly measure damage such as DNA strand breaks and free radical generation (FRG). Recent advances in...

Dynamic Angular Couch Kinematics in Radiotherapy

Authors: Eva Lee, R. Lee MacDonald, Alasdair Syme, Christopher G. Thomas

Affiliation: Department of Radiation Oncology, QE2 Cancer Centre, Nova Scotia Health, Dalhousie University, Nova Scotia Health

Abstract Preview: Purpose:
Dynamic couch rotation in radiotherapy offers dosimetric benefits, however patient comfort remains a concern. This study investigates couch kinematics in trajectory-based radiotherapy plan...

Dynamic Winston-Lutz Testing for FFF Beams

Authors: Cambridge L Bui-Nguyen, Alexander S. Nguyen, Liqiang (Lee) Tao

Affiliation: Varian AOS @Epic Care, UC Berkeley

Abstract Preview: Purpose: Dynamic Winston-Lutz (WL) testing provides a comprehensive framework for evaluating the accuracy of isocenter alignment. This study investigates the impact of dynamic beam modulation, such as...

Evaluating a Novel Solution for GYN Planning: Integrated Dynamic Collimator Rotation and Static Angle Modulated Ports with a New Optimizer

Authors: Ben Archibald-Heeren, Grace Gwe-Ya Kim, Kelly Kisling, Xenia Ray

Affiliation: UC San Diego, Icon Cancer Centres, University of California, San Diego, University of California San Diego

Abstract Preview: Purpose: To evaluate improvements in external beam plans for gynecological cancers from a novel planning solution: RapidArc Dynamic (RAD) (Varian Medical Systems, Palo Alto, CA) which optimizes VMAT w...

Evaluation of Potential Dosimetric Risks from Intra-Fractional Motion in Single-Isocenter Stereotactic Radiosurgery

Authors: Brian D. Casto, Mathew Y Kang, Lichung Ku, Samuel J Wang, Joseph B. Ying, Walker Ray Zimmerman

Affiliation: Salem Health Cancer Center, Salem Health

Abstract Preview: Purpose: Varian HyperArc is an advanced radiotherapy module designed to efficiently deliver high-quality multi-target stereotactic radiosurgery (SRS) treatment plans on Varian linacs. However, the int...

Evaluation of the Improvements of a New Leaf Model (Enhanced Leaf Model) for the Halcyon

Authors: Evan Barber, Gloria P. Beyer, Callum Hartley, Jordi Saez, Philip Wheeler

Affiliation: Department of Radiation Oncology, Hospital Clinic de Barcelona, Department of Radiotherapy Physics, Velindre University NHS Trust, Medical Physics Services, LLC

Abstract Preview: Purpose: To evaluate the Enhanced Leaf Model (ELM) in Eclipse v18 to the standard leaf model for the Halcyon multileaf collimator (MLC) using a measurement-based method.
Methods: The Halcyon’s doub...

High-Fidelity Monte-Carlo Model Development and Validation of a 0.5T Bi-Planar Linac-MR Using Topas: Multileaf Collimator Modeling, Positioning, and Dose Verification in Slab Phantoms

Authors: B. Gino Fallone, Alireza Gazor, Andrei D. Ghila, Gawon Han, Patricia A. K. Oliver, Michael W. Reynolds, Keith D. Wachowicz, Tania Rosalia Wood, Shima Y. Tari, Eugene Yip

Affiliation: Medical Physics Division, Department of Oncology, University of Alberta, Nova Scotia Health, Dept. of Medical Physics and Dalhousie University, Dept. of Physics and Atmospheric Science, Dept. of Radiation Oncology, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta; MagnetTx Oncology Solutions, www.magnetTX.com, Department of Medical Physics, Arthur J. E. Child Comprehensive Cancer Centre, Dept. of Medical Physics, Cross Cancer Institute and Dept. of Oncology, University of Alberta, Department of Medical Physics, BC Cancer, Medical Physics Division, Department of Oncology, University of Alberta and Department of Medical Physics, Cross Cancer Institute

Abstract Preview: Purpose: To develop and validate a high-fidelity Monte-Carlo (MC) model of a 0.5T bi-planar Linac-MR in TOPAS, focusing on accurate Multileaf Collimator (MLC) modelling and positioning for open apertu...

Non-Planar Narrow-Beam CT: Near Scatter-Free, High-Resolution Breast Imaging at Screening Mammography Doses.

Authors: Peymon Ghazi

Affiliation: MALCOVA Inc.

Abstract Preview: Purpose: To develop a near scatter‐free breast CT imaging system that expands coverage of the posterior breast anatomy and enhances contrast resolution for solid masses and microcalcifications, while ...

Optimal Lattice Design for Spatially Fractionated Radiotherapy (SFRT) of Brain Metastasis in Gamma Knife (GK)

Authors: Brankica Andelic, Young-Bin Cho, Tara M. Gray, Andrew Robert Hadfield, Hakan Nordstrom

Affiliation: Elekta, Cleveland Clinic

Abstract Preview: Purpose: Spatially Fractionated Radiotherapy (SFRT) requires highly modulated dose distribution inside a tumor volume optimized using sets of planning structure of spheres in a lattice arrangement. To...

Optimizing Motion Management QA: Clinical Integration of Aapm TG-306 for the Radixact Synchrony System

Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...

Optimizing Motion Profiles of a Dynamic Collimator in Proton Therapy

Authors: Simona Cacciatore, Albert Du, Ryan T. Flynn, Alonso N. Gutierrez, Patrick M Hill, Daniel E. Hyer, Eric Jensen, Kaustubh A. Patwardhan, Julien Smeets, Blake R. Smith, Nhan Vu, Karsten K. Wake

Affiliation: University of Wisconsin, Miami Cancer Institute, Baptist Health South Florida, Department of Human Oncology, University of Wisconsin School of Medicine and Public Health, Ion Beam Applications (IBA), University of Iowa, Iowa Health Care

Abstract Preview: Purpose: To evaluate time reduction strategies for the Dynamic Collimation System (DCS) using an IBA (Louvain-la-Neuve, Belgium) proton therapy system. Delivery time for a multi-energy-layer patient s...

Proactive Quality Assurance for Adaptive Radiotherapy: Real-Time Mlc Verification with Myqa SRS

Authors: James L. Giltz, Michael J. Merrick

Affiliation: Alyzen Medical Physics, University of Kentucky

Abstract Preview: Purpose: To evaluate the capability of MyQA SRS in performing high-resolution machine QA to verify multileaf collimator (MLC) behavior and integrity for adaptive radiotherapy (ART). This study demonst...

Research on the Target Current Pulse Counting Method for Measuring the Output Dose of Medical Standing Wave Electronic Linear Accelerator

Authors: Shixiong Huang, Daming Li

Affiliation: The Affiliated Nanhua Hospital, University of South China, The Affiliated Cancer Hospital of Xiangya School of Medicine, Central South University/Hunan Cancer Hospital

Abstract Preview: Purpose: To assess the feasibility of using target current pulse signals to evaluate the output dose of medical standing wave electronic linear accelerators.
Methods: The Target I signal of the acc...

Spot Map Modification for Planning Optimization on a Spot Scanning Proton System with Adaptive Aperture

Authors: Austen N. Curcuru, Winter Green, Yao Hao, Jiayi Liu, Yuting Peng, Tiezhi Zhang, Xiandong Zhao

Affiliation: Washington University School of Medicine, Department of Radiation Oncology, WashU Medicine, Virginia Commonwealth University, Washington University School of Medicine, Washington University in St. Louis

Abstract Preview: Purpose: We proposed a treatment planning optimization method that utilizes customized spot map modification to achieve less dosimetry uncertainty, monitor unit ratio (MUR) and neutron dose in a spot ...