Search Submissions ๐Ÿ”Ž

Results for "dynamic platform": 12 found

A Plan Complexity Comparison between Monaco and Eclipse - Meta Analysis of 17,000 Plans and 30,000 Beams

Authors: Christopher Colyer, Leon F Dunn, Jonathan Dunning, Simon Goodall, Andy Schofield

Affiliation: GenesisCare

Abstract Preview: Purpose: Modern radiotherapy is characterized by complex treatment plans utilizing dynamic MLCs, gantry positions and recently, collimator rotations. The purpose of this work was to compare the plan c...

BEST IN PHYSICS IMAGING: Revolutionizing Neurocognitive Dynamic Pattern Discovery with Self-Supervised AI in Functional Brain Imaging

Authors: Lei Xing, Zixia Zhou

Affiliation: Department of Radiation Oncology, Stanford University, Department of Radiation Oncology, Stanford University, Stanford

Abstract Preview: Purpose: Functional brain imaging techniques, such as functional magnetic resonance imaging (fMRI), generate high-dimensional, dynamic data reflecting complex neural processes. However, extracting rob...

Commission and Clinical Implementation of the 1st Step-and-Shoot Proton Arc Therapy for Head and Neck Cancer Patient Treatment

Authors: Xiaoda Cong, Rohan Deraniyagala, Xuanfeng Ding, Xiaoqiang Li, Jian Liang, Peilin Liu, Craig Stevens, Xiangkun Xu, Weili Zheng

Affiliation: Corewell Health William Beaumont University Hospital, Corewellhealth William Beaumont University Hospital, William Beaumont University Hospital, Corewellhealth William Beaumont Hospital, Department of Radiation Oncology, Corewell Health William Beaumont University Hospital

Abstract Preview: Purpose:
Commission a step-and-shoot arc therapy(SPArc-step&shoot) for treating head-neck cancer patients as a desired interim milestone toward full dynamic treatment.
Methods:
An in-house de...

Commissioning and Evaluation of Deviceless 4DCT

Authors: Christopher A. Aguilera, Hunter Tillery, Cheyann Windsor

Affiliation: Oregon Health & Science University, Northwest Medical Physics Center

Abstract Preview: Purpose: To demonstrate a method of acquiring 4DCT commissioning datasets for deviceless 4DCT which relies on an image-based algorithm instead of an external breathing signal for 4D image binning. The...

Evaluation of Time Delays in a Surface-Guided Radiotherapy-Based Gating System Using Exactrac Dynamic and Truebeam Linear Accelerator

Authors: Hiroki Katayama, Hiroki Kawasaki, Motonori Kitaoka, Yosuke Takahashi, Takashi Tanii, Masato Tsuzuki

Affiliation: Kagawa University Hospital

Abstract Preview: Purpose:
Surface-guided radiotherapy (SGRT) with ExacTrac Dynamic (ETD) allows motion tracking and beam gating during treatment delivery. Accurate evaluation of beam-on and beam-off delays is essen...

Feasibility of Using a Dynamic-Platform with High-Resolution Patient-Specific QA Device for Periodic and Patient-Specific-QA in Respiratory-Gated Radiotherapy Lung SBRT Treatment

Authors: Tae Kyu Lee

Affiliation: Allina Health

Abstract Preview: Purpose: To assess the feasibility of a dynamic-platform integrated with high-resolution patient-specific-quality-assurance (PSQ device for periodic quality assurance (PQA) and PSQA in respiratory-gat...

Implementation of Radiochemotherapy Applied to Virtual Spheroids Using an Open-Source Multiscale Computational Framework

Authors: Ignacio Espinoza, Ignacio Narea, Beatriz Sanchez-Nieto

Affiliation: Institute of Physics, Pontificia Universidad Catรณlica de Chile

Abstract Preview: Purpose: This study aims to evaluate the tumor response to combined radiochemotherapy on MCF7 spheroids using an open-source multiscale computational framework. The model provides a platform to simula...

Investigation of Triggered Imaging and Auto Beam Hold Using a Dynamic Thorax Phantom for Intra-Fraction Motion Management

Authors: Liu Hong, Zhong Su

Affiliation: University of Arkansas for Medical Sciences, Department of Radiation Oncology, University of Arkansas for Medical Sciences (UAMS)

Abstract Preview: Purpose: During treatment delivery on TrueBeam platform 2.7, Triggered Imaging (TI) enables kV images acquisition at regular intervals and Auto Beam Hold (ABH) provides beam pausing if the target is m...

Leveraging Codex-Based Spatial Profiling of the Tumor Microenvironment in Concurrent Radiation Therapy and Immunotherapy

Authors: Todd A Aguilera, Bassel Dawod, Sebastian Diegeler, Eslam Elghonaimy, Purva Gopal, Jiaqi Liu, Hao Peng, Arely Perez Rodriguez, Nina N. Sanford, Robert Timmerman, Megan B Wachsmann, Haozhao Zhang

Affiliation: Department of Radiation Oncology, UT Southwestern Medical Center, Medical Artificial Intelligence and Automation (MAIA) Lab, Department of Radiation Oncology, UT Southwestern Medical Center, UT Southwestern Medical Center

Abstract Preview: Purpose: This study pioneers the integration of CODEX (co-detection by indexing)-based spatial profiling and advanced computational techniques to investigate the tumor immune microenvironment (TIME) i...

Opentps: An Open-Source Radiotherapy Treatment Planning System to Foster Research, Innovation, and Education in Medical Physics

Authors: Ana Maria Barragan Montero, Damien Dasnoy, Sylvain Deffet, Valentine Dormal, Colin Gaban, Melanie Ghislaine, Valentin Hamaide, Guillaume Janssens, John A. Lee, Eliot Peeters, Danah Pross, Luciano Rivetti, Benjamin Roberfroid, Romain Schyns, Kevin Souris, Edmond S. Sterpin, Sophie Wuyckens

Affiliation: Ion Beam Applications SA, Hospital Riviera-Chablais, UCLouvain, Multitel, Universitรฉ Catholique de Louvain, IBA, Faculty of Mathematics and Physics, University of Ljubljana, Universite Catholique de Louvain

Abstract Preview: Purpose: Treatment planning systems (TPSs) are essential for simulating and optimizing radiotherapy treatments. However, clinical TPSs are expensive software commercialized by private companies and of...

Optimizing Motion Management QA: Clinical Integration of Aapm TG-306 for the Radixact Synchrony System

Authors: Hulya Ozdemir Buss, Jeffrey Geiger, Kim Howard, Julius G. Ojwang, Neelu Soni

Affiliation: Mercy Hospital Springfield

Abstract Preview: Purpose: The Radixact Synchrony system integrates real-time motion tracking and compensates to improve treatment accuracy for moving targets. This study presents a streamlined and efficient quality as...

Two Years in - Lessons Learned from Managing a Global Medical Physics Webinar Series

Authors: Ghada Aldosary, Abdullah A. Alshreef, Amineh Khatib Hamad, Eenas A. Omari

Affiliation: Loma Linda University Medical Center, Jerusalem, KASCH- Ministry of National Guard Health Affairs, Department of Radiation Oncology, Medical College of Wisconsin

Abstract Preview: Purpose:
Webinars are an effective tool for disseminating knowledge and expertise to a global audience. A medical physics webinar series was established in 2022 to provide accessible continued educ...