Authors: Brett Bocian, Nesrin Dogan, John C. Ford, Alan Pollack, Ryder Marshall Schmidt, Junwei Shi, Jorge D Vega
Affiliation: University of Miami, University of Miami Sylvester Comprehensive Cancer Center
Abstract Preview: Purpose: X-ray fluorescence computed tomography (XFCT) is an emerging molecular imaging modality gaining attention in cancer theranostics with high-Z metal nanoparticles (MNPs). While XFCT has been de...
Authors: Dale W. Litzenberg, Ikechi S Ozoemelam, Rowan Paplanus, Michael Pillainayagam, Donald A. Roberts
Affiliation: University of Michigan, Oregon Health & Science University
Abstract Preview: Purpose: Clinical linear accelerators use dual foil scattering systems designed to achieve large uniform fields (up to 25×25cm²), which can reduce beam fluence by up to 93% compared to the unmodified ...
Authors: Jameson T. Baker, Yijian Cao, Jenghwa Chang, Sean T Grace, Lyu Huang, Jian Liu, Echezona Simon Obi, Anurag Sharma
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
To validate the end-to-end dosimetrical accuracy of Varian HyperSight CBCT for adaptive radiotherapy (ART), from simulation to dose delivery, using radiochromic film dosimetry in a Rando p...
Authors: Sarah A. Ashmeg, Travis James McCaw, Joseph Shields, Matthew Spector, Christopher Tyerech, Christopher T Wilke
Affiliation: UPMC Hillman Cancer Center, UPMC Hillman Cancer Center and University of Pittsburgh School of Medicine, Department of Radiation Oncology, UPMC Hillman Cancer Center, Department of Radiation Oncology, University of Pennsylvania, UPMC
Abstract Preview: Purpose: Patients with oral cavity cancer often undergo surgical extirpation prior to radiation, and surgical implants are utilized to reconstruct the resulting defect. This study dosimetrically evalu...
Authors: Ivan M. Buzurovic, Matthew W. Jacobson, Marjan Khosravi
Affiliation: Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology, University of Massachusetts Lowell, Department of Physics, Lowell, MA/Brigham and Women's Hospital, Harvard Medial School, Dana-Farber Cancer Institute, Department of Radiation Oncology
Abstract Preview: Purpose: Annual quality assurance (QA) of high dose rate (HDR) brachytherapy (BT) gynecological (GYN) applicators is critical to ensure accurate and consistent source position and dose delivery. In th...
Authors: Ronald C Chen, Hao Gao, Nicolas Gerard, Harold Li, Yuting Lin, Jarrick Nys, Jufri Setianegara, Mark Szczepanski, Aoxiang Wang
Affiliation: 4Physikalisch-Technische Werkstätten (PTW), Department of Biomedical Engineering, Huazhong University of Science and Technology, Ion Beam Applications (IBA), Department of Radiation Oncology, University of Kansas Medical Center
Abstract Preview: Purpose: Modern synchrocyclotrons can produce magnetically-scanned protons at ultra-high dose-rates (FLASH). However, their pulsed nature leads to high doses-per-pulse (DPP) which can cause non-neglig...
Authors: Dylan Yamabe Breitkreutz, Lee Chin, Brige P. Chugh, Mark D'Souza, Brian M. Keller, Anthony Kim, Michelle K. Nielsen, Arjun Sahgal
Affiliation: Sunnybrook Health Sciences Centre
Abstract Preview: Purpose: The Elekta Unity MR-linac delivers highly conformal SBRT treatments using IMRT. These treatment plans require patient-specific quality assurance (PSQA) measurements to detect discrepancies be...
Authors: Gulakhshan M Hamad, Sina Mossahebi, Yannick P. Poirier, Amit Sawant
Affiliation: University of Maryland School of Medicine, Maryland University Baltimore
Abstract Preview: Purpose:
The combination of ultra-high dose rate (UHDR) proton therapy, known for normal tissue sparing, with spatially-fractionated radiotherapy (SFRT), promising enhanced tumor control and tissue...
Authors: Milad BaradaranGhahfarokhi, Manuel A. Morales Paliza
Affiliation: Vanderbilt University Medical Center
Abstract Preview: Purpose: The purpose of this study was to commission Varian HDR surface applicators using a high-resolution diode array and film dosimetry. This work evaluates dosimetric characteristics of these appl...
Authors: Min Cheol Han, Chae-Seon Hong, Changhwan Kim, Dong Wook Kim, Hojae Kim, Hojin Kim, Jin Sung Kim, HO Lee, Kwangwoo Park, Ye-In Park, Junyoung Son
Affiliation: Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Department of Radiation Oncology, Yongin Severance Hospital, Yonsei University College of Medicine
Abstract Preview: Purpose: Overresponse in surface in-vivo dosimetry using optically stimulated luminescence dosimeter (OSLD) depends on the beam incidence angle. This study aimed to investigate correction factors to d...
Authors: Abdullah A. Alshreef, Grant A. McAuley, Jerry D Slater
Affiliation: Loma Linda University Medical Center, Loma Linda University
Abstract Preview: Purpose: In this project we investigate the use of a single permanent magnet quadrupole to create pass-through proton minibeams suitable for potential clinical use and preclinical radiobiology experim...
Authors: Edward A. Opalko, Matthew B. Podgorsak, Dheerendra Prasad
Affiliation: Roswell Park Comprehensive Cancer Center
Abstract Preview: Purpose: To design a 3D printed insert for Varian’s SRS Head Phantom that allows for multi-planar film dosimetry and to evaluate its ability in end-to-end testing for Gamma Knife treatments.
Method...
Authors: Javier Chiasson, Dominique Guillet, Arthur Lalonde, Bryan R. Muir, James Renaud, Karim Zerouali
Affiliation: Universite de Montreal, Centre Hospitalier de l'Universite de Montreal, National Research Council
Abstract Preview: Purpose: To develop, optimize and validate a novel applicator for ultra-high dose rate (UHDR) electron radiotherapy incorporating an electrostatically shielded beam current transformer (BCT) for real-...
Authors: Chang Heon Choi, Minjae Choi, Yoonsuk Huh, Jin Jegal, Jung-in Kim, So-Yeon Park
Affiliation: Department of Radiation Oncology, Veterans Health Service Medical Center, Department of Radiation Oncology, Seoul National University Hospital
Abstract Preview: Purpose: Total Body Irradiation (TBI) aims to achieve a uniform dose distribution across the entire body. However, in conventional TBI setups that use extended source-to-surface distance (SSD) and lea...
Authors: Dr. Sheaka Alobaidli, Anju K V, Dr. Chiranjib Konar, Sreejesh MS, Dr. Vijayaprabhu N, Dr. Deepti Sharma, Dr. Hanuman Prasad Yadav
Affiliation: Amity Institute of Applied Sciences, Kuwait Cancer Control Center, Institute of Liver and Biliary Sciences, Jawaharlal Institute of Postgraduate Medical Education & Research (JIPMER), Amity institute of Applied Sciences, Amity University, Institute of Liver and Biliary Sciences(ILBS)
Abstract Preview: Purpose:
The accuracy of dose delivery in stereotactic body radiotherapy (SBRT) is critical for effectively treating hepatocellular carcinoma (HCC). This study aims to develop patient-specific 3D-p...
Authors: Lily Jo Bertemes, Careesa Billante, Ashley Cetnar, Arnab Chakravarti, Nilendu Gupta, Sagarika Jain, Maximilian Stephen Meineke, Allison N. Palmiero, Runhe Tan
Affiliation: The Ohio State University - James Cancer Hospital, Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Department of Radiation Oncology, Ohio State University Comprehensive Cancer Center, The Ohio State University, The James Cancer Center
Abstract Preview: Purpose: Ultra-High Dose Rate Radiation Therapy (UHDR-RT) induces normal tissue sparing while maintaining iso-effective tumor control compared to conventional methods, known as the “FLASH effect”. How...
Authors: Sang Hyun Cho, Amrit Kaphle, Sunil Krishnan, Neerajan Nepal
Affiliation: The University of Texas MD Anderson Cancer Center, The University of Texas Health Science Center
Abstract Preview: Purpose: To determine the basic dosimetry parameters and characteristics of a commercial cabinet x-ray unit for small animal irradiation as well as the specific dosimetry parameters for concurrent irr...
Authors: Christoph Bert, Leon Brückner, Luitpold Distel, Julian Freier, Peter Hommelhoff, Bastian Löhrl
Affiliation: Department of Radiation Oncology, Uniklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Department Physik, Friedrich-Alexander Universität Erlangen-Nürnberg
Abstract Preview: Purpose: Low energy electron (LEE) bunches in the kilo electronvolt (keV) range are thought to have a high relative biological effectiveness (RBE). To investigate this, it is necessary to establish re...
Authors: Jingying Lin, Stevan Pecic, Strahinja Stojadinovic
Affiliation: University of Belgrade, The University of Texas Southwestern Medical Center
Abstract Preview: Purpose: This study aims to determine the magnitude of polarization-induced dosimetric error for EBT4 films at different scanning orientations, and to provide guidance on selecting appropriate regions...
Authors: Yijian Cao, Jenghwa Chang, Nicholas Coupey, Lyu Huang, Jessica Jung
Affiliation: Northwell, Hofstra University Medical Physics Program
Abstract Preview: Purpose:
The Synergy bioabsorbable polymer (BP) stent, made of Platinum Chromium Alloy, is widely utilized in treating coronary artery disease. This study investigates dose perturbations caused by ...
Authors: Darwin Abraham Garcia, Michael P. Grams, Scott C Lester, Maryam Mashayekhi, Douglas John Moseley, Robert W Mutter, Sean S Park, Chrystian Quintero Mateus
Affiliation: Mayo Clinic - Rochester, Mayo Clinic
Abstract Preview: Purpose: MBRT delivers sub-millimeter wide regions of high “peak” (~10s Gy) and low “valley” (~1 Gy) doses to treat cancer. MBRT commissioning is performed in flat, uniform plastic water. Thus, differ...
Authors: Julie Colnot, Eric Deutsch, Christelle Huet, Danahé LeBlanc, Pauline Maury, Charlotte Robert, Imane Saïd Mansour, Cathyanne Schott, Francois Therriault-Proulx
Affiliation: INSERM U1030, Gustave Roussy, University Paris-Saclay, LDRI, IRSN, Medscint, THERYQ / INSERM U1030, Gustave Roussy, University Paris-Saclay, Université Paris-Saclay, Gustave Roussy, Inserm U1030, Radiothérapie Moléculaire et Innovation Thérapeutique
Abstract Preview: Purpose: FLASH radiotherapy, using ultra-high dose rates (UHDR, >100 Gy/s), spares healthy tissues while maintaining tumor control compared to conventional radiotherapy (CONV). However, UHDR dosimetry...
Authors: Milad BaradaranGhahfarokhi, Ashley Elizabeth Bonner, James R. Burns, Annie Cooney, George X. Ding, Kenneth L. Homann, Guozhen Luo
Affiliation: Corewell Health William Beaumont University Hospital, Vanderbilt University Medical Center
Abstract Preview: Purpose: The goal of this study was to evaluate the performance of a new plastic scintillating detector (PSD) system with 0.5×0.5 mm2 and 1.0×1.0 mm2 probes (referred to as Medscint0.5 and Medscint1.0...
Authors: Robert Berry, John Buatti, Nathan Burger, Ryan T. Flynn, Greg Johns, Maksim Kravchenko, Sergey Kutsaev, Yen-Po Lee, Marcos Ruelas, Joel J. St-Aubin, Timothy J. Waldron
Affiliation: RadiaBeam Technologies, University of Iowa
Abstract Preview: Purpose: To report the factory acceptance tests of a preclinical linear accelerator, the FLEX-9 electron FLASH linac from RadiaBeam Technologies.
Methods: The FLEX-9 FLASH electron linac is designe...
Authors: William P. Donahue, Lauren Smith, Shu (Stella) Xing
Affiliation: Department of Medical Physics, Memorial Sloan Kettering Cancer Center
Abstract Preview: Purpose: To quantify the dosimetric uncertainty of end-exhale gating as a function of breathing pattern.
Methods: A Truebeam delivered AP square fields to EBT4 film placed in the Quasar MRI4D M...
Authors: Rohith Kaiyum, Ozzy Mermut, Alexandra Rink
Affiliation: Department of Medical Biophysics, University of Toronto, Department of Physics and Astronomy, York University
Abstract Preview: Purpose: To investigate the relationship between chemical features and real-time response to ionizing radiation dose of radiochromic diacetylene crystals.
Methods: A number of radiochromic diacetyl...
Authors: Denise Dunn, Scott R. Floyd, Tyler V. Kay, Anna Lynnette-Price, Eric L. Martin, Stepan Mikhailov, Taylor Nguyen, Mark Oldham, Victoria J. P. Radosova, Zachary J. Reitman, Ramona Rodriguiz, Andrew Thompson, William Wetsel, Seth Wilcox, Ying Wu
Affiliation: Duke University Mouse Behavior Core, Department of Physics, Duke University, Medical Physics Graduate Program, Duke University, Duke University Medical Physics Program, Duke University, Duke University Mouse Behavioral and Neuroendocrine Analysis Core Facility, Department of Radiation Oncology, Duke University Medical Center
Abstract Preview: Purpose: FLASH radiation therapy (RT) shows promise for reducing normal tissue damage, though its mechanisms remain unclear. Using an in-vivo model with the High Intensity Gamma-ray Source (HIGS) lina...
Authors: Liang Cui, Xingyu Lu, Hang Shang, LingHong Zhou
Affiliation: Southern Medical University
Abstract Preview: Purpose: This study examines how varying dose rates of radiotherapy impact normal tissues outside the target area and analyzes the protective effects and regulatory mechanisms of ultra-high dose rate ...
Authors: Slade J. Klawikowski, Natalya V. Morrow, Haidy G. Nasief, Eric S. Paulson, An Tai, Hualiang Zhong
Affiliation: Department of Radiation Oncology, Medical College of Wisconsin
Abstract Preview: Purpose: Gafchromic film is commonly used for quality assurance in SRS/SBRT. However, its application in low-dose measurements, such as monitoring doses on cardiac implantable electronic devices—where...
Authors: Jon Burns, Angela J Da Silva, Andrew Groll, Gopinath Kuduvalli, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma, Timothy Pok Chi Yeung
Affiliation: Reflexion Medical Inc,, RefleXion Medical
Abstract Preview: Purpose: Biology-guided radiotherapy uses positron emissions from FDG-avid tumor volumes to provide a of the planned prescribed dose with high accuracy. The purpose of this work is to characterize BgR...
Authors: Wesley S. Culberson, Aleksandra Ilina, Brian W Pogue, Matthew Reed, Connor Strainis, William Scott Thomas, Nathaniel Van Asselt, Albert van der Kogel
Affiliation: University of Wisconsin: Madison, University of Wisconsin: Madison School of Veterinary Medicine, Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin - Madison, Department of Human Oncology, University of Wisconsin–Madison, University of Wisconsin-Madison, University of Wisconsin - Madison
Abstract Preview: Purpose: FLASH radiotherapy reduces skin damage in vivo from ultra-high dose rate (UHDR) irradiation relative to conventional dose rates (CDR), while preserving damage to tumor tissue. The FLASH effec...
Authors: Ashok Bhandari, Andrew Joseph Fanning, Kyle J. Gallagher, Brendan Graff, Christopher Jenkins, Kyuhak Oh, Ying Yan, Su-Min Zhou
Affiliation: University of Nebraska Medical Center
Abstract Preview: Purpose: This study aimed to design a robust experimental setup to ensure accurate dose delivery using ultra-high-dose-rate for small animal experiments by conducting dosimetric evaluations prior to a...
Authors: Rick Holly, Sumudu Katugampola
Affiliation: Gesinger Medical Center, Geisinger Medical Center
Abstract Preview: Purpose:
To quantitatively analyze long term variations in optical density of un-irradiated and irradiated EBT3 radio-chromic films and their effects on dose calibration curves in a clinical settin...
Authors: Mohammad Nazmul Alim, Regina DeWitt
Affiliation: Department of Physics, East Carolina University,, Department of Physics, East Carolina University
Abstract Preview: Purpose: This study quantifies the ability of Luxel (Al₂O₃:C) to measure radiation dose from a Moxtek X-ray source. Key aspects of OSL dosimetry, including OSL curves, dose response, depth dose, and b...
Authors: Kuan Ling Chen, Jiajin Fan, Rao Khan, Robabeh Rahimi
Affiliation: University of Maryland, Inova Schar Cancer Institute, Howard University
Abstract Preview: Purpose: This study evaluates the dose response, energy dependency, sensitivity, reproducibility, temporal response, and LET dependency along and in the plane perpendicular to a clinical proton beam f...
Authors: Jon Burns, Andrew Groll, Gopinath Kuduvalli, Thomas Laurence, Manoj Narayanan, Jeffrey Schmall, Sanchit Sharma
Affiliation: RefleXion Medical
Abstract Preview: Purpose: To simplify BgRT testing we have developed techniques that use 3D resin printed structures that can be filled with Ge-68 epoxy. This approach allows the development of highly complex, clinica...
Authors: Piotr Pater, Nicholas G. Zacharopoulos
Affiliation: McGill University, Medical Physics Unit, Gerald Bronfman Department of Oncology, McGill University
Abstract Preview: Purpose: To develop a method for accurate relative film dosimetry that incorporates non-uniformity
corrections.
Methods: The accuracy of Devic’s [1] linearization approach was evaluated using si...
Authors: Ryan Burri, Nazanin Hoshyar, Jerry W. McCoy, Yulin Song, Huma Syed
Affiliation: Bay Pines VA Medical Center
Abstract Preview: Purpose: The study aimed to streamline traditionally manual, iterative, and time-consuming VMAT commissioning process. The goal was to identify an optimal set of MLC dosimetric parameters that minimiz...
Authors: Omer Abdulaziz Ali, Robin Hill, Nathan Huntelerslag
Affiliation: Waikato Hospital, Hamilton, New Zealand, Central Coast Cancer Centre, Gosford, Australia
Abstract Preview: Purpose: Characterizing transmission through eye shields is essential to understanding dose distribution in underlying tissues. This study aims to utilize Monte Carlo (MC) simulations to model and cha...