Dosimetric Evaluation of Enhanced Dynamic Leaf Gap Modeling in Small-Field Clinical Plans: A Verification Study

Authors: Ian J. Butterwick, Sumudu Katugampola, ChangSeon Kim, Evan G. Meekins, Zhengdong Zhang

Affiliation: Mount Sinai Beth Israel, Gesinger Medical Center, Geisinger Medical Center

Abstract Preview: Purpose: To evaluate the dosimetric impact of enhanced dynamic leaf gap (EDLG) modeling in Eclipse V18.0 on small-field dosimetry within VMAT plans.
Methods: Plans with small fields (1 cm x 1 cm to...

Effects of Enhanced Leaf Modeling on Single-Isocenter Multi-Target Stereotactic Radiosurgery Dose Accuracy

Authors: Thomas R. Mazur, Kevin Renick, Matthew C. Schmidt, Xiaodong Neo Zhao

Affiliation: Washington University in St. Louis School of Medicine, Washington University School of Medicine

Abstract Preview: Purpose: To compare dose calculation accuracy for single-isocenter multi-target stereotactic radiosurgery plans (SIMT-SRS) in Eclipse V18.0 with enhanced leaf model (ELM) using the anisotropic analyti...

Impact of Ion Chamber Selection on Enhanced Leaf Modeling Predictions of Dosimetric Leaf Gap and Leaf Transmission Factors

Authors: Michael Ashenafi, Nicholas Becerra Espinosa, Mario Ramos Gallardo, Matthew Pacella, Sean M. Tanny

Affiliation: Department of Radiation Oncology, University of Rochester

Abstract Preview: Purpose: A new multileaf collimator (MLC) model has been introduced in Varian Eclipse v18.0, with the treatment planning system (TPS) explicitly modeling the leaf end effects. The vendor recommends a ...

Investigating the Effect of Beam Flattening Filter on Dose Estimated with Varian’s Original and Enhanced Mlc Models

Authors: Kenny Guida, Hongyu Jiang, Harold Li, Hem Bahadur Moktan Tamang

Affiliation: University of Nebraska Medical Center, Department of Radiation Oncology, University of Kansas Medical Center

Abstract Preview: Purpose: Varian Eclipse v18.0 introduced Enhanced Leaf Model (ELM) of MLC, which provides better dose calculation accuracy than original DLG-based MLC model. The leaf-gap (LG) parameter for ELM repres...

Investigation of the Impact of Dlg Changes on Plan Quality and Patient Specific QA

Authors: Nicole C. Detorie, Steven M. Kirsner, Remy Y. Manigold

Affiliation: Scripps Cancer Center

Abstract Preview: Purpose:
Dosimetric Leaf Gap (DLG) is an important factor in obtaining the proper beam model in the Eclipse treatment planning system. The purpose of this study was to investigate the dosimetric im...

Quantitative Evaluation of Eclipse’s (V18) Ability to Address Dosimetric Leaf Gap Variations

Authors: D. Michael Lovelock, Charlotte Elizabeth Read, Ren-Dih Sheu, Jing Wang, Tingyu Wang

Affiliation: Icahn School of Medicine at Mount Sinai, Jersey Shore University Medical Center

Abstract Preview: Purpose:
Early Eclipse models use rectangular fluence profiles (widened by the dosimetric leaf gap (DLG) to account for the fact that leaf tips are rounded). Eclipse Version 18 (V18) uses enhanced ...